ACSR

standards: HRN N. C1.351



DIN 48201

IEC 60228

06

Aluminium - steel rope for overhead line

Uninsulated ropes

Technical data

Construction

Al/St ropes are made of rigid drawn aluminium wire and


round galvanized steel wire.
Wire characteristics
density (kg/dm3)
elasticity module (Mpa)
coefficient of linear elongation per C

Al

Aluminium-steel rope consists of one or more concentrically


stranded galvanized steel wires in the centre, and
concentrically stranded aluminium wires in external layers.
Small weight of aluminium and its good conductivity are
combined with high resistance to elongation of steel.

Fe
2,7
70000
23x10-6

7,78
200000
11,5x10-6

Application
Used as uninsulated overhead line for transmission
and distribution of electric power.

Dimensions - nominal
cross-section

Calculated cross-sections

Al/Fe

Al

Fe

Sum

mm2

mm2

mm2

Ratio

mm2

16/ 2,5
25/ 4
35/ 6
44/32
50/ 8
50/30
70/12
95/15
95/55
105/75
120/20
120/70
125/30
150/25
170/40
185/30
210/35
210/50
230/30
240/40
265/35
300/50
305/40
340/30

6
6
6
1,4
6
1,7
6
6
1,7
1,4
6
1,7
4,3
6
6
4,3
7,7
6
7,7
6
7,7
6
7,7
11,3

15,3
23,8
34,3
44
48,3
51,2
69,9
94,4
96,5
105,7
121,6
122
127,9
148,9
171,8
183,8
209,1
212,1
230,9
243
263,7
304,3
304,6
339,3

2,5
4
5,7
31,7
8
29,8
11,4
15,3
56,3
75,5
19,8
71,3
29,8
24,2
40,1
29,8
34,1
49,5
29,8
39,5
34,1
49,5
39,5
29,8

Construction

17,8
27,8
40
75,7
56,3
81
81,3
109,7
152,8
181,5
141,4
193,3
157,7
173,1
211,9
213,6
243,2
261,6
260,7
282,5
297,8
353,7
344,1
369,1

Al

External
diameter
Number

Fe

of layers

6x1,8
6x2,25
6x2,7
14x2
6x3,2
12x2,33
26x1,85
26x2,15
12x3,2
14x3,1
26x2,44
12x3,6
30x2,33
26x2,7
30x2,7
26x3
26x3,2
30x3
24x3,5
26x3,45
24x3,74
26x3,86
54x2,68
48x3

1
1
1
1
1
1
2
2
1
1
2
1
2
2
2
2
2
2
2
2
2
2
3
3

mm

1x1,80
1x2,25
1x2,7
7x2,4
1x3,2
7x2,33
7x1,44
7x1,67
7x3,2
19x2,25
7x1,9
7x3,6
7x2,33
7x3,1
7x2,7
7x2,33
7x2,49
7x3
7x2,33
7x2,68
7x2,49
7x3
7x2,68
7x2,33

5,4
6,8
8,1
11,2
9,6
11,7
11,7
13,6
16
17,5
15,5
18
16,3
17,1
18,9
19
20,3
21
21
21,8
22,4
24,4
24,1
25

Weight

Al

Fe

Netto

kg/km

kg/km

kg/km

41,8
65,4
94,2
121,5
132,2
141,2
192,7
260,3
266,3
291,9
335,3
337,1
353,2
410,5
474,3
506,8
576,6
585,5
636,5
670,2
726,8
839
841
936

19,9
31
44,7
248,3
62,7
234
89,4
120,2
441,4
594,1
155,6
558,6
234
190,1
314,2
234
267,2
387,9
234
309,6
267,2
387,9
309,6
234

62
97
140
378
196
383
285
384
722
907
496
913
595
607
798
748
852
986
878
990
1,003
1,239
1,160
1,177

Permitted
tensile
load

Conductor
resistance
at 20oC

max.
/km

5,825
9,03
12,66
45,5
17,14
44,225
26,315
35,14
80,2
106,635
44,885
98,195
57,8
54,315
77,04
66,225
74,95
92,275
73,03
86,46
82,955
105,12
99,305
92,505

1,878
1,2
0,835
0,657
0,595
0,564
0,413
0,306
0,299
0,274
0,237
0,236
0,226
0,194
0,168
0,157
0,138
0,136
0,125
0,119
0,109
0,949
0,949
0,085

Permitted
current

90
125
145
170
290
290
350
350
410
410
425
470
520
535
590
610
630
645
680
740
740

121

TK_group06.indd 121

1/5/11 4:02 PM

Potrebbero piacerti anche