S T R U C T U R E m a g a z i n e February 2004
31
checking the existing structure for conformance to the building code in effect code at the time of the original design and to the state of the art that existed at the time of the original design only. A full design review requires that the structural adequacy be based on the requirements of the building code in effect at the time of the design review and the state of the art that existed at the time of the review. Some design values determined by the NER-466 AITC GLVD will vary based
on the number of laminations in the individual member. Contact AITC at 7012 S. Revere Parkway, Suite 140, Englewood, CO 80112-5092 for guidance in determination of allowable stresses for structural glued laminated timber members for a specified stress-grade combination, species, and number of laminations. It is hoped that dissemination of this data will eliminate one of the problems faced by the engineer in the design review of existing structures.
Robert M. Powell was conferred Honorary Member status in the American Institute of Timber Construction (AITC,) following decades of service and Professional Membership. Mr. Powell served as Chairman of the AITC Technical Advisory Committee, Chairman of the AITC Technical Review Board, Chairman of the AITC Evaluation of Existing Structures and the Field Drilling and Notching Task Committees.
References
1. AITC letter of October 3, 1985 on Implementation of Tension Lamination Requirement-Visually Graded Lumber. 2. ASTM D 3737-02 Standard Practice for Establishing Allowable Properties for Structural Glued Laminated Timber (Glulam), Section 10.1 3. Uniform Building Code 1958 Edition & Uniform Building Code Standards; 23-13-58 and 25-14-58.
from experience
4. Uniform Building Code and Building Code Standards, 1964 Edition. 5. Uniform Building Code Standards, 1973 Edition.
To contact AITC:
7012 S. Revere Parkway Suite 140 Englewood, CO 80112 Phone: (303) 792-9559 FAX: (303) 792-0669 Email: info@aitc-glulam.org Web: www.aitc-glulam.org
structuremag.org
32
S T R U C T U R E m a g a z i n e February 2004
from experience
Allowable Stresses for Glued Laminated Timber Members in Existing Buildings, Douglas-fir, coast
Stress-Grade Combination Source of Stress Value
Bending about X-X Axis Fbx Fc prep x tension face Fc perp x compression face Fvx impact & cyclic loads Fvx all other loads Fvx wane both sides Ex Modulus of Elasticity Bending about Y-Y Axis Fby Fc perp y Fvy impact & cyclic loads Fvy all other loads Fvy multiple width-impact & cyclic loads Fvy multiple width-all other loads Ex Modulus of Elasticity Axially Loaded Ft tension parallel Fc compresseion parallel E axial-Modulus of Elasticity End Grain Bearing Fg full bearing Fg partial bearing Radial Strength Frt tension Frt wind & seismic Frc Radial Compression *Add 200 PSI for 15 or more laminations **Add 100 PSI for 15 or more laminations
5 1958 UBC
*2,600 415 415 165 165 1,800,000
10 AITC GLVD
1,800 560 560 190 240 1,800,000 2,150 560 165 210 70 90 1,700,000
11 AITC GLDV
*2,400 560 560 190 240 1,800,000 1,950 560 165 210 70 90 1,700,000
1958 UBC
*2,600 415 415 165 165 1,800,000
1958 UBC
2,600 415 415 165 165 1,800,000
AITC GLDV
1,800 560 560 190 190 1,800,000 1,750 560 165 210 70 90 1,600,00
55 55 55 415
55 55 55 415
55 55 55 415
Table 1
Allowable Stresses for Glued Laminated Timber Members in Existing Buildings, Douglas-fir, coast
Stress-Grade Combination Source of Stress Value
Bending about X-X Axis Fbx Fc prep tension face Fc perp compression face Fvx impact & cyclic loads Fvx all other loads Fvx wane Modulus of Elasticity Bending about Y-Y Axis Fby Fc perp y Fvy impact & cyclic loads Fvy all other loads Fvy multiple width-impact & cyclic loads Fvy multiple width-all other loads Modulus of Elasticity Axially Loaded Ft tension parallel Fc compresseion parallel E axial-Modulus of Elasticity End Grain Bearing Fg full bearing Fg partial bearing Radial Strength Frt tension Frt wind & seismic Frc Radial Compression
A 1964 UBC
2,600 450 450 165 165 1,800,000
B AITC GLVD
1,800 650 650 190 240 1,800,000 1,650 560 165 210 70 90 1,700,000
1964 UBC
2,400 450 450 165 165 1,800,000
AITC GLDV
1,600 650 650 190 240 1,700,000 1,550 560 165 210 70 90 1,600,00
1,800 650 650 190 240 1,800,000 1,550 560 165 210 70 90 1,600,000
55 55 450
15 55 560
55 55 450
15 55 560
55 55 450
15 55 560
Table 2
S T R U C T U R E m a g a z i n e February 2004
33