COUNTENDER 20+
no
sti
COUNTENDER 20+ The New Generation 3 Part Differential Hematology Blood Cell Counter
Throughput: 60 seconds per result Cost effective : one of the lowest consumption rates of reagents on the market Up to 20 000 patient results (including histograms) can be stored Equipped with an Electronic Noise Reduction System ELENOR for accurate platelet counts
Automatic update of software directly from USB port SFRI DMS: data management for compiled coordinated reports Compact size, large color LCD display: comfort and ease of use Built-in thermal printer, external keyboard and mouse provided Optional barcode reader: saves time, avoids identification errors and allows for hassle free routine
SFRI Cleaner 3.1 Cleaner MAINTENANCE M AINTENANCE SFRI CleanEZ 3.1 Shutdown Emergency SOLUTIONS S OLUTIONS SFRI Clair 3.1 cleaner
NAME
TYPE
3 tubes N 3 tubes LNH 6 tubes N 6 tubes LNH 1 tube
REFERENCE
R021005 R021001 R021002 R021006 R021003
CVS
OVS
CONTROLS
BloodTrol 16
105 days
14 days
CALIBRATOR BloodCal
45 days
5 days
LCD display, 20 parameters and 3 color histograms for WBC, RBC and PLT
Parameters
WBC, RBC, HGB, PLT, MCV, MPV measured; Lym#, Mon#, Gran#, HCT, MCH, MCHC, PCT% calculated; Lym%, Mon%, Gran%, RDW-SD, RDW-CV, PDW%, P-LCR% given by histograms.
Input/Output
Keyboard, mouse and barcode interfaces External monitor and parallel printer interfaces RS232 x 1; USB port x 2
Printout
Fast thermal printer, 57.5 mm wide paper, recording width 48 mm Optional external printer
Principles
Impedance technology for blood cell counting and cyanide-free optical detection for hemoglobin.
Performance
Parameter WBC (109/L) RBC (1012/L) HGB (g/L) MCV (fL) PLT (109/L) Linearity Range 0-99.99 0-9.99 0-300 40-150 10-999 Precision (CV%) 2.5% @ 5-10 2.0% @ 4-6 2.0% @ 50-200 1.0% @ 70-120 5.0% @ 200-450
Display
8 LCD screen High resolution: 640x480 mm Color display
Operating Environment
Temperature Humidity Atmospheric pressure 18C 35C < 85% (max humidity) 86.0 106 kPa
Quality Control
Levey-Jennings charts and calculation of Mean, SD, CV; up to 9 control files, 31 runs/ file.
Power Requirements
A.C. 110/220 V 10%; 50 60 Hz Fuse: A.C. 250 V; 2 A
Throughput
60 seconds per sample
Dimensions
330(W) x 430(H) x 380(D) mm
Sample Volume
Venous Capillary Pre-diluted 14 l 14 l 20 l
Weight
17.5 Kg
Memory Storage
20 000 patient files Mono-directional LIS transfer
M ed
i ic al D
ag
SFRI - Lieu-dit Berganton - 33127 Saint Jean dIllac - FRANCE Office +33 (0)5 56 68 80 50 - Fax +33 (0)5 56 21 79 03 contact@sfri.com - www.sfri.com
no
sti
cs
Non contractual document. Specifications subject to change without notice. Ref. C20ENG-V201210 Copyright 2012 SFRI. All rights reserved.
Technical Specifications