Documenti di Didattica
Documenti di Professioni
Documenti di Cultura
PG
Table of Contents
A. O. Smith Innovation and Quality . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 iCOMM and iCOMM Elite Remote Monitoring System . . . . . . . . 4 5 Gas Water Heaters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 617 Power Burner Gas Water Heaters . . . . . . . . . . . . . . . . . . . . . . . . .1820 Oil-Fired Water Heaters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 23 Electric Heat Pump Water Heaters . . . . . . . . . . . . . . . . . . . . . . . . 2425 Electric Water Heaters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2631 Boilers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3249 Ac-U-Temp Hot Water Supply Systems . . . . . . . . . . . . . . . . . . . . . 5051 Electric Boilers & Hot Water Generators . . . . . . . . . . . . . . . . . . . 5253 Custom Semi-Instantaneous Water Heaters . . . . . . . . . . . . . . . . 5455 Storage Tanks/Hot Water Generators . . . . . . . . . . . . . . . . . . . . . 5657 Commercial Line Overview & Support Network . . . . . . . . . . . . . 5859
A. O. Smith innovation and quality...engineered into every product from the inside out.
The Eliminator Self-Cleaning Technology In Master-Fit Models
A. O. Smith Master-Fit commercial gas water heaters have always provided maximum installation exibility for both new construction and replacement applications. Now, Master-Fit offers The Eliminator for automatic self-cleaning protection against build-up of lime and other sediments. As deposits of lime and other sediments accumulate inside the tank, they form a barrier between the burner and the water, concentrating heat around the critical weld areas. The result is reduced energy efciency, higher operating costs, and greater risk of premature tank leaks.
The Eliminator directs incoming cold water under pressure to sweep the bottom of the tank to keep sediment moving so it doesnt accumulate. With The Eliminator, every Master-Fit water heater can be expected to maintain its rated efciency longer and deliver reliable service year after year.
And because A. O. Smith PermaGlas Ultra Coat is applied after the tank is welded, there is no chance of weld burn that can burn away normal glass lining and expose bare steel to water.
Once tanks are lled with PermaGlas, they are rotated (computer controlled ) for precise, even coating.
Tanks are then rotated further, allowing the excess PermaGlas to drain from the tank.
After pre-drying in 200F ovens, the tanks are then red to 1,600F, fusing the PermaGlas to the steel tank.
Hardware
MODEL NO. ITEM DESCRIPTION
iCOMM Features
I
ICMA
IMDA
Needed if more than one water heater will be connected to the control module. Order 1 MDA for each water installed.
Provides remote monitoring via www.aosmithconnect.com I E-mail and text messaging of fault conditions I Leak detection and notication I Graphs unit performance and operational history I BACnet compatibility with building management systems
iCOMM Requirements
I IABA iCOMM Alarm Box Accessory alarm box that includes an audible alarm and alarm light.
Note: If using wireless internet an optional wireless adapter is needed to provide wired connection to the communications module. Recommended adapter Linksys WGA600N or equivalent
Facility must have "always on" internet (wired or wireless) I iCOMM compatible water heater or boiler I Annual iCOMM subscription
Cyclone Xi Custom Xi (DSE models) and Gold Xi (DVE models) Genesis Boilers VF Variable Fire Series Boilers
For information and ordering call 1-888-WATER02 or visit www.aosmithconnect.com Complete Coverage, Total Peace
What is iCOMM Elite?
iCOMM Elite utilizes the latest technology in commercial water heating to allow us to interact with, proactively manage and monitor your A. O. Smith water heaters or boilers from anywhere in the world via the Internet. With this newly redesigned industry-exclusive service, A. O. Smith can monitor your water heaters around the clock, alert you instantly in case of a problem, and begin xing any potential problems immediately. How is that for ultimate peace of mind?
Elite
iCOMM ELITE
1. 2. 3.
Conrm you have a compatible unit. Verify that you have an Internet connection in the same room as the water heater(s). Call 1-888-WATER02 to purchase and arrange installation.
80% thermal efciency, ideal for commercial applications and where negative air pressure is a problem
The Conservationist BPD-75 tank-type commercial gas water heater is intended for applications such as small ofce buildings and duplex apartment homes. The BPD-75 features a power direct vent design with a factory-installed blower. The blower permits sealed combustion direct vent operation with separate venting and air intake runs from outside the structure. The BPD-75 offers installation versatility by allowing venting and intake runs up to 50 feet, using 3 Schedule 40 PVC pipe. The power direct vent design also eliminates the potential for performance and safety problems caused by negative air pressure, which is found in many commercial applications with inadequate indoor ventilation.
Specially designed dip tube directs incoming cold water to create turbulence in the tank to reduce lime and sediment build-up I Prolongs tank life, maintains high energy efciency, maximizes hot water output
Built-in safety device prevents pilot or main burner operation if blower is not operating I Blower has 110V/120V electrical system, with maximum 2A draw
Durable Brass Drain Valve CSA Certied and ASME Rated T&P Relief Valve, Factory-Installed Meets the Thermal Efciency and Standby Loss Requirements of U. S. Department of Energy and Current Edition of ASHRAE/IESNA 90.1 Maximum Hydrostatic Working Pressure: 150 PSI 3-Year Limited Tank Warranty
BTU FIRST HOUR MODEL GAL. INPUT DELIVERY NO. CAP. PER HOUR RATING 40
BPD-75 Natural BPD-75 Propane 75 75 70,000 65,000 117 112 161 148
HT.
DIA.
140
46 42 69-5/8 69-5/8 26 26 352 352
Dip Tube
I Carries
inlet water deep into tank. a solid state ignition surface that does not utter or blow out. Provides increased reliability and efciency over spark ignition systems. Eliminates the pilot and saves energy. temperature control and LED diagnostics. specically developed by A. O. Smith for water heaters is permanently fused to steel at 1600F, providing years of corrosion protection and dependable use. Tank-mounted, screw-in replaceable anode for longer tank life. BTU input assures plenty of hot water is available by providing faster recovery rates and higher rst hour draws. input, multiport burner for improved combustion efciency and low NOx.
Air is precisely drawn through the combustion control port and exhausted through plastic pipe. Controlling the airow through the heater enhances and regulates the combustion process. In standby mode, the combustion control port restricts air circulation through the heater. Provides more venting exibility and savings. A new quiet blower allows exhaust venting through the roof or sidewall with plastic pipe such as PVC, CPVC, and ABS. Allowable vent lengths of up to 100 equivalent feet make installation easy in any situation. BTF-80 is a Category 3 (positive pressure non-condensing) appliance.
Power Venting
I
Intelli-Vent Control
I Provides
Glasslined Tank
I Glass
Anode
I
High Input
I 80,000
Burner
I High
BTU FIRST HOUR MODEL GAL. INPUT DELIVERY NO. CAP. PER HOUR RATING
HT* .
DIA.
140
55 66-5/16 25-3/8 340 *Height to top of draft hood
BTF-80
74
80,000
78
194
Conservationist BT models provide reliable, efcient service for applications such as ofce buildings and duplex/fourplex apartment homes.
Glass lining and anode rod protect steel tank from corrosion
Includes automatic safety shutoff gas if pilot is extinguished and high temperature energy cutoff (ECO)
Compact Design
I
Three-leg design
Piezo Ignitor
I
CSA Certied and ASME Rated T&P Relief Valve, Factory-Installed Meets the Thermal efciency and standby loss requirements of the U.S. Department of Energy and current edition of ASHRAE/IESNA90.1 3-Year Limited Tank Warranty 5-Year limited Tank Warranty Optional
All dimensions in inches
HT.
DIA.
140
45 52 52 65 61 68-1/2 24 27-3/4 27-3/4 215 275 350
BT MODELS BT-65 BT-80 BT-100 65 74 98 65,000* 75,100 75,100 109 125 142 158 182 182
Conservationist BTN models are equipped with a blower that produces a power-induced draft of make-up air prior to burner ignition.
Complies with SCAQMD Rule 1146.2 and other Air Quality Management Districts with Similar Requirements* Category 1 Appliance
I
Can be commonly vented with other Category 1 appliances and uses standard metal single-wall type B vent, connected directly to blower outlet
Glass lining and anode rod protect steel tank from corrosion
Advanced electronic valve features polarity sensing to help ensure proper operation I Easy-to-understand diagnostics and a nearly indestructible hot surface ignitor
HT.*
DIA.
140
55 53 62 55 66-5/16 25-3/8 66-5/16 25-3/8 71-1/4 71-1/4 26-1/2 26-1/2 300 300 350 350
BTN MODELS BTN-80 BTN-80 BTN-100 BTN-100 74 74 98 98 80,000 (Nat) 76,000 (LP) 90,000 (Nat) 80,000 (LP) 137 126 175 156 193 184 218 193
*After January 1st, 2012 Models will no longer comply with SCAQMD Rule 1146.2 requirements for low NOx emissions. Intelli-Vent is a Registered Trademark of Emerson Electric Company
The Master-Fit BTR series provides outstanding performance and maximum installation exibility for both new construction and replacement applications. Each unit is designed to be as much as a foot shorter than the models they usually replace, and multiple options for placement of water connections and low installation clearances are additional installer-friendly features.
Low-prole draft diverter helps for installation in tight spaces I Automatic motorized ue damper helps minimize standby heat loss
Meets the Thermal efciency and standby loss requirements of the U.S. Department of Energy and current edition of ASHRAE/IESNA90.1 CSA Certied and ASME Rated T&P Relief Valve, Factory-Installed Maximum Hydrostatic Working Pressure: 160 PSI Fully Automatic Control System
I
Hot and cold water connections can be made through front, top or rear of unit I The Eliminator system operates when cold water is connected through front
Exclusive process provides superior protection against corrosion I CoreGard anode rods with stainless steel core provide additional corrosion protection
Manual-reset gas shutoff device prevents excessive water temperature I Electric temperature control for precise temperature regulation adjustable 120F180F I Gas pressure regulator and pilot lter
10
Eliminates standing pilot, saves energy I Includes power ON/OFF switch I Provides ame failure response in less than one second
The Master-Fit BTR-151 and BTR-201 are designed for installation in booster applications to supply commercial dishwashers with very high temperature water. A booster water heater is normally used in conjunction with a standard water heater delivering hot water at a lower temperature to meet the non-dishwashing needs of a restaurant or other food service application. With 32 gallons stored, these compact units measure only 45 high, and hot and cold water connections can be made in the top, front or rear for installation versatility.
The Features Of The Master-Fit BTR Plus Booster Models: Built-In Induced Draft Blower
I
Produces power-induced draft of make-up air prior to burner ignition I Provides more efcient control of heat through the ue collector I No draft hood or barometric damper required
Can be commonly vented with other Category 1 appliances, using standard metal type B vent
Meets the Thermal efciency and standby loss requirements of the U.S. Department of Energy and current edition of ASHRAE/IESNA90.1
MODEL NO.
BTU FIRST GAL. INPUT HOUR CAP. PER HOUR DELIVERY RATING
71 81 81 100 100 81 100 120,000 154,000 180,000 199,000 199,000 199,000 199,000 250,000 251,000 275,000 305,000 365,000 390,000 500,000 166 206 231 263 263 250 263 312 289 337 342 414 448 545
HT.** DIA.
100
116 149 175 193 193 193 193 242 243 267 296 354 378 485
140
83 107 124 132 132 132 132 173 174 90 211 243 270 346 69-3/4 27-3/4 73 27-3/4
400 470 470 603 603 470 630 630 750 630 750 725 760 820
BTR BOOSTER MODELS BTR-151(A) BTR-201(A) 32 32 150,000 199,900 167 216 364 485 145 194 104 139 45 45 27-3/4 27-3/4 460 460 440 440
BTR-120 Models are approved for 5 vent using a 6 to 5 reducer. *BTR-250(A), BTR-251(A) and BTR-275(A) models shipped with a 8 to 6 vent reducer. Certied for both 6 or 8 vent. **Height to top of vent connection.
11
The Master-Fit Plus BTN series meets Southern California and Texas low NOx standards and features induced-draft design. This provides more efcient control of heat through the ue collector. Like all Master-Fit water heaters, the BTN series provides outstanding performance and maximum installation exibility for both new construction and replacement applications. Each unit is designed to be as much as a foot shorter than the models they usually replace, and multiple options for placement of water connections and low installation clearances are additional installer-friendly features.
Factory-mounted on top of unit and pre-wired for easy installation I Provides power-induced draft of combustion make-up air prior to burner ignition I Requires no draft hood or barometric damper
Complies with
An excellent option for retrot and upgrade installations Uses standard metal single-wall type B vent, can be commonly vented with other Category 1 appliances I Vent connects directly to blower outlet
Hot and cold water connections can be made through front, top or rear of unit I The Eliminator system operates when cold water is connected through front
Exclusive process provides superior protection against corrosion I CoreGard anode rods with stainless steel core provide additional corrosion protection
Compliance
I
12
Meets the Thermal efciency and standby loss requirements of the U.S. Department of Energy and current edition of ASHRAE/IESNA90.1 I Complies with SCAQMD Rule 1146.2 and other Air Quality Management Districts with similar requirements for low NOx emissions+
Digital solid-state diagnostic control system helps make installation and troubleshooting easy I Digital Temperature Control adjusts thermostat setting from 120F to 180F, accurate to within 2F I Control includes Power On/Standby Indicator, ECO Open Indicator, Reset Status Indicator and Heating Mode Indicator I Silicon nitride ignitor is rugged and dependable, equipped with separate ame prover rod I Manual-reset gas shutoff device prevents excessive water temperature
CSA Certied and ASME Rated T&P Relief Valve, Factory-Installed Intermittent Electronic Ignition With Solid-State Ignition Control
I I
Eliminates standing pilot, saves energy Includes power ON/OFF switch I Provides ame failure response in less than one second
Plug Kits
I
MODEL NO.+
BTU FIRST GAL. INPUT HOUR CAP. PER HOUR DELIVERY RATING
71 81 99 99 99 100 100 100 120,000 154,000 180,000 199,000 199,000 199,000 250,000 275,000 310,000 366,000 390,000 262 266 312 337 371 415 436 166 206 245
HT.
DIA.
100
116 149 175 193 193 193 242 267 301 355 378
140
83 107 125 138 138 138 173 190 215 253 270 63 68 72 72 72 72 72 72 73 73 73 27-3/4 27-3/4 27-3/4 27-3/4 27-3/4 27-3/4 27-3/4 27-3/4 27-3/4 27-3/4 27-3/4
400 470 603 620 603 603 603 603 725 725 725
*Models meet 82% TE Utility Rebate. BTN-199C models for sale in California only. +After January 1, 2012, Models will no longer comply with SCAQMD Rule 1146.2 requirements for low NOx emissions.
13
The A. O. Smith Cyclone Xi is the industrys most technologically advanced commercial water heater. The BTH-300, BTH-400 and BTH-500 models take Cyclone Xi performance to the highest levels, with up to 96% thermal efciency, a 130-gallon storage tank, and inputs of 300,000, 400,000 and 500,00 BTU. For highdemand applications, 2, 3 or 4 Cyclone units can be installed in a manifold conguration, delivering total storage up to 520 gallons and total input up to 2 million BTU. Cyclone Xi provides outstanding hot water output, with dramatic savings on operating costs compared to units with standard 80% efciency. A. O. Smiths leading-edge engineering delivers conventional power vent or sealed combustion power direct vent versatility, low NOx emissions, and excellent space-saving characteristics.
Positioned in center of tank, surrounded by water to virtually eliminate radiant heat loss from chamber I Spiral heat exchanger maximizes efciency of heat transfer to the water stored in the tank I Top mounted burner and spiral heat exchanger work together to minimize harmful effects of calcium/lime accumulation
Exclusive process provides superior protection against corrosion in varying water conditions I Powered Anodes are of permanent design and do not require replacement unless damaged I Both sides of heat exchanger coil are glasslined for protection against ue gas condensate inside coil
iCOMM Compatible and can be monitored from remote locations. Call 1.888.WATER02 for more information I Provides detailed water heater status information I Precise temperature control I Built-in diagnostics I Run history information
Conventional and sealed-combustion power venting (vertical or sidewall) allows for various venting options (See instruction manual for complete venting installation instructions and allowable venting lengths) I Direct vent intake and exhaust pipe can terminate separately outside building or through single opening using concentric vent assembly I Uses inexpensive PVC, CPVC or ABS pipe for venting
Compliance
I
Meets the Thermal efciency and standby loss requirements of the U.S. Department of Energy and current edition of ASHRAE/IESNA90.1
14
4 Vent 120 Exhaust 4 Vent 120 Intake 120 Exhaust 3 Vent 50 Intake 50 Exhaust 4 Vent 120 Intake 120 Exhaust 3 Vent 50 Intake 50 Exhaust 4 Vent 120 Exhaust 3 Vent 50 Exhaust 3 Vent 50 Exhaust
*Chart applies to BTH -120 through BTH-250 models only. *4 PVC required on BTH-300 through BTH-500 for up to 70 equivalent feet of venting. 6 PVC Required for longer installations See instruction manual for complete venting instructions and allowable vent lengths.
Top cover has rear cut-away for easy access to serviceable parts I 0 installation clearances on sides and rear, 2 installation clearance on top, 4 alcove installation clearance in front of unit I 0 clearance to combustibles (walls, oors, etc.)
MODEL NO.
BTH-120 BTH-150 BTH-199 BTH-250 BTH-300 BTH-400 BTH-500 BTH-120A BTH-150A BTH-199A BTH-250A BTH-300A BTH-400A BTH-500A BTX-100
GALLON CAPACITY
60 100 100 100 130 130 130 60 100 100 100 130 130 130 50
HT.
55-1/2 75-1/2 75-1/2 75-1/2 75-1/2 75-1/2 75-1/2 55-1/2 75-1/2 75-1/2 75-1/2 75-1/2 75-1/2 75-1/2 66-3/4
DIA.
27-3/4 27-3/4 27-3/4 27-3/4 33-1/8 33-1/8 33-1/8 27-3/4 27-3/4 27-3/4 27-3/4 33-1/8 33-1/8 33-1/8 22
15
Cyclone HE BTX-80
The 50-gallon power vent Cyclone HE is designed to produce more hot water than any commercial gas water heater in its class. Thanks to the internal helical heat exchangersimilar to the design of the industry-leading Cyclone Xi modelsthe unit achieves 90% thermal efciency. With its small footprint and easy installation, Cyclone HE delivers heavy-duty performance for numerous light-duty smaller applications, making it a perfect choice for restaurants, ofces and other applications.
Submerged heat exchanger provides much greater heat transfer surface than standard straight ue tube I Produces 90% thermal efciency, which saves money on operating costs, and increases hot water output compared to standard-efciency water heaters
System allows combined vertical and horizontal vent runs, using 2 or 3 PVC, ABS or CPVC pipe
Modular Blower
I
A condensate drain supplied to connect heat exchanger outlet to blower I PVC Vent Attenuation Assembly (VAA) supplied for applications where extra-quiet operating environment is essential
22 diameter, combined with 90% efciency, 76,000 BTU input means Cyclone HE can be installed in less space than a larger 75-gallon unit with equal or better performance
A. O. Smith exclusive process provides superior protection against corrosion I Protects all interior tank surfaces including inside and outside of helical heat exchanger
Equipped with long-lasting silicon nitride hot surface ignitor no standing pilot I Advanced electronics for more precise control of water temperature and simplied system diagnostics I 180F maximum temperature setting
Allows Cyclone HE to be installed as part of combination space heating/water heating applications, or any system requiring a recirculating hot water loop I Plugs for the recirculating taps are factory installed
16
The classic Cyclone helical heat exchanger coil delivers 90% thermal efciency.
BTU FIRST HOUR MODEL GAL. INPUT DELIVERY NO. CAP. PER HOUR RATING NATURAL GAS
BTX-80 50 76,000 127
HT* .
DIA.
100
83
140
59 68-1/4 22 210 *Height to top of the heater Not available in LP gas
SUGGESTED SPECIFICATION
Natural gas water heater shall be A. O. Smith Cyclone, HE model # BTX-80, with 90% thermal efciency, a storage capacity of 50 gallons, an input rating of 76,000 BTU per hour, a recovery rating of 83 gallons per hour at 100F rise and a maximum hydrostatic working pressure of 150 PSI. Water heater(s) shall be of power vent design, using 2 or 3 PVC pipe for horizontal and/or vertical vent runs.
17
Suitable for natural or propane gas Electronic ame safeguard control with intermittent spark ignition I Main and pilot automatic gas valves with gas pressure regulators I Diaphragm air switch for proof of blower operation I Flame inspection port
High-temperature limit control (manual reset) CSA Certied and ASME Rated T&P Relief Valve I Hinged-door control compartment for easy access I Upper and lower thermostats for accurate temperature control I Standard control is for 120F-180F water service I Factory-installed low-water cutoff
Blue Diamond glass coating provides superior corrosion resistance compared to the industry-standard glass lining I Equipped with multiple anode rods for additional corrosion protection
Heavy-Duty Jacket
I
Complies with
Heavy-gauge steel jacket with baked powder-coated nish for durability I Two 3 handhole inspection openings
Design-certied by UL (Underwriters Laboratories), according to ANSI Z21.10 standards I Meets the thermal efciency and standby loss requirements of the U.S. Department of Energy and current edition of ASHRAE/IESNA 90.1
18
Low NOx burners from 300,000 BTUH up to 2 million BTUH Comply with SCAQMD Rule 1146.2 and other Air Quality Management Districts with Similar Requirements for low NOx emissions*
Factory-approved mutual control arrangement 5 or 10-year extended limited warranty I High or low water pressure switch I AGA-rated T&P valve I Modular graphic burner systems management on heaters with 270,000 BTU input and over I Low NOx burner available on select models
Two layers of high-temperature ceramic ber insulation in combustion chamber I Flame inspection port opening I Mounted on rugged channel iron skids I National board stamping I ASME-rated temperature and pressure gauge I Low-water cutoff I Barometric draft regulator I 120V control circuit I Drain valve I 180F water service thermostats
All dimensions in inches
MODEL NO.*
FIRST TEMP. RISE HOUR F-GPH RECOVERY MOTOR HP 120V VENT DELIVERY CAPACITY 60 Hz 1 PHASE SIZE RATING 80 100 140
256 313 367 382 507 644 818 451 722 936 1130 1372 1615 531 822 1016 1210 1452 1695 902 1096 1290 1532 1775 2017 2259 2582 2824 1178 1450 1692 1935 2177 2419 2662 2904 170 241 359 327 485 654 873 364 737 970 1212 1515 1818 364 727 970 1212 1515 1816 727 970 1212 1515 1816 2121 2424 2727 3030 873 1212 1515 1816 2121 2424 2727 3030 136 193 247 262 387 524 698 291 582 776 970 1212 1455 291 582 776 970 1212 1455 582 776 970 1212 1455 1697 1939 2182 2424 698 970 1212 1455 1697 1939 2182 2424 97 1/17 HP 2.5 AMPS 5 6 6 6 7 8 10 6 8 10 10 12 12 6 8 10 10 12 12 8 10 10 12 12 14 14 16 16 10 10 12 12 14 14 16 16 138 1/17 HP 2.5 AMPS 176 1/17 HP 2.5 AMPS 187 277 374 499 208 416 554 693 866 1039 208 416 554 693 866 1039 416 554 693 866 1039 1212 1385 1/4 HP 4.6 AMPS 1/4 HP 4.6 AMPS 1/4 HP 4.6 AMPS 1/3 HP 5.5 AMPS 1/4 HP 4.6 AMPS 1/4 HP 4.6 AMPS 1/3 HP 5.5 AMPS 1/3 HP 5.5 AMPS 1/2 HP 7.4 AMPS 1/2 HP 7.4 AMPS 1/4 HP 4.6 AMPS 1/4 HP 4.6 AMPS 1/3 HP 5.5 AMPS 1/3 HP 5.5 AMPS 1/2 HP 7.4 AMPS 1/2 HP 7.4 AMPS 1/4 HP 4.6 AMPS 1/3 HP 5.5 AMPS 1/3 HP 5.5 AMPS 1/3 HP 5.5 AMPS 1/2 HP 7.4 AMPS 1/2 HP 7.4 AMPS 1/2 HP 7.4 AMPS
HT.
DIA.
DEPTH
SHIP WEIGHT
BTP-150-140 BTP-150-199 BTP-150-255 BTP-150-270 BTP(N)-150-400 BTP(N)-150-540 BTP-150-720 BTP-200-300 BTP-200-600 BTP(N)-200-800
82-1/4 36-1/2 82-1/4 36-1/2 82-1/4 36-1/2 82-1/4 36-1/2 82-1/4 36-1/2 82-1/4 36-1/2 82-1/4 36-1/2 84-1/2 44-3/4 84-1/2 44-3/4 84-1/2 44-3/4 84-1/2 44-3/4 84-3/4 44-3/4 84-3/4 44-3/4 92 92 92 92 92 92 89 89 89 89 89 89 96-1/4 108 108 114 114 114 114 114 114 114 114 44-3/4 44-3/4 44-3/4 44-3/4 44-3/4 44-3/4 55 55 55 55 55 55 55 55 55 55 55 55 55 55 55 55 55
48 48 48 57-1/2 57-1/2 57-1/2 57-1/2 66-1/2 66-1/2 66-1/2 66-1/2 661/2 66-1/2 66-1/2 66-1/2 66-1/2 66-1/2 66-1/2 81-1/2 76-1/2 76-1/2 76-1/2 76-1/2 91-1/2 91-1/2 91-1/2 91-1/2 91-1/2 76-1/2 76-1/2 76-1/2 91-1/2 91-1/2 91-1/2 91-1/2 91-1/2
1292 1292 1292 1397 1397 1505 1510 2098 2098 2103 2103 2467 2675 2150 2150 2308 2308 2584 2774 3207 3212 3212 3212 3402 3528 3669 4277 4419 3667 3667 3667 3837 3837 3837 4477 4619
BTP(N)-200-1000 200 BTP(N)-200-1250 200 BTP-200-1500 BTP-300-300 BTP-300-600 BTP(N)-300-800 200 300 300 300
BTP(N)-300-1000 300 BTP(N)-300-1250 300 BTP(N)-300-1500 300 BTP-400-600 BTP(N)-400-800 400 400
BTP(N)-400-1000 400 BTP(N)-400-1250 400 BTP(N)-400-1500 400 BTP(N)-400-1750 400 BTP(N)-400-2000 400 BTP-500-2250 BTP-500-2500 BTP-600-720 500 500 600
1558 3/4 HP 10.2 AMPS 1732 3/4 HP 10.2 AMPS 499 693 866 1039 1212 1385 1/3 HP 5.5 AMPS 1/3 HP 5.5 AMPS 1/3 HP 5.5 AMPS 1/2 HP 7.4 AMPS 1/2 HP 7.4 AMPS 1/2 HP 7.4 AMPS
BTP(N)-600-1000 600 BTP(N)-600-1250 600 BTP(N)-600-1500 600 BTP(N)-600-1750 600 BTP(N)-600-2000 600 BTP-600-2250 BTP-600-2500 600 600
Models with an (N) are available in low NOx (include the N in the model number when ordering). *After January 1, 2012, Models will not meet SCAQMD Rule 1146.2 requirements for low NOx emissions.
19
These gas power burner models provide an outstanding thermal efciency of 80% or more and are suitable for commercial applications.
UL listed power burner ASME construction I CSA Certied and ASME rated T&P relief valve I Handhole cleanout(s) for easy maintenance I Three-year limited tank warranty I Fully automatic controls ensure safe, efcient operation I Barometric draft damper ensures correct airow in the vent I Factory Start-up Included, required for activating warranty and assuring quality performance I Mounted on rugged channel iron skids for easy transport during installation I Multiple anodes for extra protection against tank corrosion I Flame inspection port opening for visual inspection of ame characteristics during operation I Spark pilot ignition I Factory-installed burner for easy installation I Complies with SCAQMD rule 1146.2 and other Air Quality Management Districts with similar requirements for low NOx emissions I Meets the Thermal efciency and standby loss requirements of the U.S. Department of Energy and current edition of ASHRAE/IESNA90.1 I Contact Canadian customer service for availability in Canada I 3-year limited tank warranty
5-year limited tank warranty 3 vent options: atmospheric, sidewall and direct vent
Shown here is the power burner combustion chamber used in the BTP-540A, BTP-650A & BTP-740A models. These models can vent through a side wall up to 100 ft. without an external blower. 1. Exclusive PermaGlas Ultra Coat Glasslined Tank protects tank surfaces and all welds from the corrosive effects of hot water. 2. Proylite 3100 Chamber Wall retains heat, ensuring cool operation and maximum heat transfer to water, not the room. 3. Premix Combustion System provides super clean low-NOx ame. Helps eliminate hot spots and uneven heat transfer. 4. Sealed Combustion Chamber reduces heat loss.
All dimensions in inches
MODEL NO.+
BTP-139 BTP-199 BTP-270 BTP-370 BTP-139A BTP-199A BTP-270A BTP-370A BTP(V)-540A* BTP(V)-650A* BTP(V)-740A*
FIRST RECOVERY GAL. HOUR CAPACITY/GPH VENT CAP. DELIVERY 100F RISE SIZE RATING
86 86 86 75 86 86 86 75 85 85 85 196 253 268 412 196 253 322 412 583 690 778 136 193 262 359 136 193 262 359 523 630 718 6 6 8 8 6 6 8 8 9 9 9
INPUT BTU/HR.
NATURAL GAS
HT.
DIA.
140,000 199,000 270,000 370,000* 140,000 199,000 270,000 370,000* 540,000 650,000 740,000
74 3/4 27 3/4 74 3/4 27 3/4 74 3/4 27 3/4 74 3/4 27 3/4 74 3/4 27 3/4 74 3/4 27 3/4 74 3/4 27 3/4 74 3/4 27 3/4 93 93 93 29 1/2 29 1/2 29 1/2
20
*Available with optional horizontal sidewall or sealed direct vent termination kits (specied at time of order). +After January 1, 2012, Models will not meet SCAQMD Rule 1146.2 requirements for low NOx emissions.
Our Duraclad COF-199 and larger models have an optional two-stage pump for use with below-grade oil storage tanks. Features include two handhole clean-outs for easy servicing. The large volume COBT models are available as a dual-fuel heaternatural gas as well as oil-red.
For small to medium-sized applications UL listed oil burner I 180F adjustable thermostat I Single-stage oil pump for simple, efcient operation. I Solenoid oil valve (standard on 455, 700) I 3/4 drain valve I CSA Certied and ASME rated T&P relief valve I Two handhole clean-outs (COF-385 and larger, and ASME models) for easy maintenance. I Barometric draft regulator provided for proper operation, ensures correct ow in the vent I Foam insulation I Intermittent ignition I CoreGard anode rod with stainless steel core wont corrode, wont break off I Flame observation port I PermaGlas glasslined tank with 160 PSI maximum working pressure I 3-year limited tank warranty
Options
I
Two-stage pump for use with underground oil storage tanks I Oil solenoid safety valve I ASME construction available on models COF-315 and larger I 5-year limited tank warranty
MODEL NO.
BTU FIRST GAL. INPUT HOUR CAP. PER HOUR DELIVERY RATING*
86 86 84 75 75 69 199,000 245,000 315,000 385,000 455,000 700,000 253 298 364 426 494 727
HT.
DIA.
DEPTH
100
193 238 305 373 441 679
140
138 170 218 267 315 485 74-3/4 24-3/4 74-3/4 24-3/4 74-3/4 24-3/4 74-3/4 24-3/4 74-3/4 24-3/4 79-1/2 24-3/4 37 37 37 37 37 37
*Based on No. 2 fuel oil. All models have 1/8 HP motor. Add S to the end of the model number for standard (COF-199S) and A to the end of the model number for ASME (COF-700A) tanks.
21
Large Volume High Output Oil and Dual Fuel Water Heaters
Conservationist COF models offer oil fuel burners (No. 1 or 2 oil). COBT models feature combination gas/oil powered burners for the versatility of operating with natural gas/propane and No. 1 or 2 oil. Conservationist COF/COBT models include some of the largest and most powerful A. O. Smith tank-type water heating systems available with storage/input options up to 600 gallons/2,500,000 BTU/hour and recoveries as high as 2,424 gallons/hour at 100F rise. All models feature fully automatic controls with safety shutoff, two thermostats (upper and lower) for accurate temperature control, and ASME tank construction.
Use either No. 1 or 2 fuel oil 3450 rpm motor I Multi-annular fuel containment combustor head I Oil ignition transformer I Integral 2-stage fuel unit and oil safety valve
Use either natural gas or propane and No. 1 or 2 fuel oil 3450 rpm motor I Multi-annular fuel containment combustor head I Gas/electric pilot and gas ignition transformer I Pilot and main pressure regulators I Air safety switch I Manual fuel-selector switch I Integral two-stage fuel unit
High temperature limit control (manual reset) CSA Certied and ASME rated T&P relief valve I Hinged-door control compartment for easy access I Upper and lower thermostats for accurate temperature control
Blue Diamond coating provides superior corrosion resistance compared to industry-standard glass lining I Equipped with multiple anode rods for additional corrosion protection
Heavy-Duty Jacket
I
Heavy gauge steel jacket with baked powder-coated nish for durability I Two 3 handhole inspection openings
Compliance
I
Meets the Thermal efciency and standby loss requirements of the U.S. Department of Energy and current edition of ASHRAE/IESNA90.1
Two Layers Of High Temperature Ceramic Fiber Insulation In Combustion Chamber Flame Inspection Port Opening Mounted On Rugged Channel Iron Skids ASME Stamping Low-Water Cutoff 3-Year Tank Limited Warranty
Factory mutual approved control arrangement 5-year or 10-year extended limited warranty I High or low water pressure switch I 180F water service thermostats I CSA certied and ASME rated T&P relief valve I Modular graphic burner systems management on heaters with 270,000 BTU input and greater
MODEL NO.
100
136 193 247 262 339 387 524 698 291 582 776 970 1212 1455 291 582 776 970 1212 1455 582 776 970 1212 1455 1697 1939 2182 2424 698 970 1212 1455 1697 1939 2182 2424
140
97 138 176 187 242 277 374 416 208 416 554 866 866 1039 208 416 554 693 866 1039 416 554 693 866 1039 1212 1385 1558 1732 499 693 866 1039 1212 1385 1558 1732
VENT SIZE
HT.
DIA.
DEPTH
SHIP WEIGHT
COF-150-140 COF-150-199 COF-150-255 COF-150-270 COBT-150-350 *COF/COBT-150-400 COF/COBT-150-540 COF/COBT-150-720 *COF/COBT-200-300 COF/COBT-200-600 COF/COBT-200-800 COF/COBT-200-1000 COF/COBT-200-1250 COF/COBT-200-1500 *COF/COBT-300-300 COF/COBT-300-600 COF/COBT-300-800 COF/COBT-300-1000 COF/COBT-300-1250 COF/COBT-300-1500 COF/COBT-400-600 COF/COBT-400-800 COF/COBT-400-1000 COF/COBT-400-1250 COF/COBT-400-1500 COF/COBT-400-1750 COF/COBT-400-2000 COF/COBT-500-2250 COF/COBT-500-2500 COF/COBT-600-720 COF/COBT-600-1000 COF/COBT-600-1250 COF/COBT-600-1500 COF/COBT-600-1750 COF/COBT-600-2000 COF/COBT-600-2250 COF/COBT-600-2500
150 150 150 150 150 150 150 150 221 221 221
140,000 199,000 255,000 270.000 350,000 400,000 540,000 720,000 300,000 600,000 800,000
5 1/7 HP, 4.4 AMPS 6 6 6 7 1/4 HP, 4.6 AMPS 7 8 10 6 1/3 HP, 5.5 AMPS 8 10 10 12 3/4 HP 10.2 AMPS 12 6 8 10 10
47 47 47
1292 1292 1292 1397 1397 1397 1505 1510 2098 2098 2103 2103 2467 2675 2150 2150 2308 2308 2584 2774 3207 3212 3212 3212 3402 3528 3669 4277 4419 3667 3667 3667 3837 3837 3837 4477 4619
82-1/4 36-1/2 57-1/2 82-1/4 36-1/2 57-1/2 82-1/4 36-1/2 57-1/2 82-1/4 36-1/2 57-1/2 82-1/4 36-1/2 57-1/2 84-1/2 44-3/4 66-1/2 84-1/2 44-3/4 66-1/2 84-1/2 44-3/4 66-1/2 84-1/2 44-3/4 66-1/2 84-3/4 44-3/4 66-1/2 84-3/4 44-3/4 81-1/2 92 92 92 92 92 92 89 89 89 89 89 89 96-1/4 108 108 114 114 114 114 114 114 114 114 44-3/4 66-1/2 44-3/4 66-1/2 44-3/4 66-1/2 44-3/4 66-1/2 44-3/4 66-1/2 44-3/4 81-1/2 55 55 55 55 55 55 55 55 55 55 55 55 55 55 55 55 55 76-1/2 76-1/2 76-1/2 76-1/2 91-1/2 91-1/2 91-1/2 91-1/2 91-1/2 76-1/2 76-1/2 76-1/2 91-1/2 91-1/2 91-1/2 91-1/2 91-1/2
201 1,000,000 201 1.250,000 201 1,500.000 300 300 300 300,000 600,000 800,000
300 1,000,000 300 1,250,000 300 1,500,000 411 411 600,000 800,000
3/4 HP, 10.2 AMPS 1/3 HP 5.5 AMPS 1/3 HP, 1/4 HP 4.6 AMPS 5.5 AMPS
12 12 8 10 10 12
411 1,000,000 411 1,250,000 397 1,500,000 397 1,750,000 397 2,000,000 375 2,250,000 375 2,500,000 594 720,000
12 14
14 16
594 1,000,000 594 1,250,000 594 1,500,000 594 1,750,000 594 2,000,000 575 2,250,000 575 2,500,000
16 10 10 12
12 14
1 HP 16 AMPS
14 16 16
23
Air-to-Water heat pump water heaters remove unwanted heat and humidity from the surrounding air and use it to heat water. The refrigeration-based system produces cool, dehumidied air for spot cooling or to reduce the load on air conditioning system.
High Efciency water heating Environmentally-Friendly Green Technology uses non-ozone depleting R-134a refrigerant I Simplied Installation I Efcient Scroll Compressor I Coefcient of Performance (COP) between 3.9 and 4.2 for water heating I Standard 208/230 VAC, 3 phase power (optional 460 VAC, 3 phase) I Sanitary hot water for commercial or industrial uses I Maximum 140F nal tank temperature at common indoor temps
Accessories Include:
I I
Digital Temp Controller with Tank Probe Metal Mesh Cleanable Filter I Corrosive Duty Package; 316 stainless steel cabinet polyurethane coated evaporator coil and blower housing. Recommended for coastal areas.
All dimensions in inches
DIMENSIONS C.O.P.
3.9 4.1 3.9 4.2 4.2 3.9 3.9
G.P.M.
7 11 15 20 23 28 34
*Performance rating at 75 F, 55% Relative Humidity and 100 incoming water temperature **Blower design at 0.3 external static pressure C.O.P. coefficient of performance All models standard 208/230V, 3-phase, 60 Hz Optional 460v 3ph 60Hz Optional 240v 1ph 60Hz (available on AWH-35 and AWH-55 only)
24
25
Factory-Wired Controls
I
Medium-watt density design disperses element temperature over larger surface contact area to minimize scale build-up, maximize efciency and prolong element life I Element options from 1.5 kW to 6 kW (non-simultaneous or simultaneous operation), recoveries from 6 GPH to 49 GPH at 100F rise
Temperature control (adjustable from 110F to 170F on single element; 120F to 180F on dual-element models) I Manual reset high temperature cutoff per element (dual-element models) I Factory-wired for nonsimultaneous operation; easily converted to simultaneous operation (3-phase models only)
Glasslined Tank
I
120V, 277V single-phase, and 208V, 240V and 480V unbalanced 3-phase delta I Easily converted to single-phase at terminal block (except for 208V with 6000W elements) I Single-element heater, singlephase only (see chart for dualelement options)
Provides long-lasting protection against corrosion I Equipped with anode rod for additional protection against corrosion
Compliance
I
Meets the standby loss requirements of the U.S. Department of Energy and current edition of ASHRAE/IESNA90.1
Provide electrical service to heater and connect to block (not supplied on 120V and 277V models)
Maximum Hydrostatic Working Pressure: 150 PSI 3-Year Limited Tank Warranty
I
MODEL NO
DEL-6S DEL-10S DEL-15S DEL-20S DEL-30D DEL-40D DEL-50D
GAL . CAP.
6 10 15 20 30 40 50
KILOWATTS MAXIMUM
2.5 6 6 6 12 12 12
HEIGHT
DIA.
DEL MODELS 15-1/2 18-1/4 26 22-1/4 30-7/8 32-1/4 32-1/4 14-1/4 18 18 21-3/4 21-3/4 24 26-1/2
DEN MODELS DEN-30D DEN-40D DEN-52D DEN-66D DEN-80D 30 40 50 66 80 119 10 12 12 12 12 12 34-1/2 45-1/8 54-7/8 60-3/4 59-3/8 62-7/16 20-1/2 20-1/2 20-1/2 21-3/4 24 29-3/8 95 110 128 167 206 331
26
DEN-120D
Superior scaling resistance, resulting in long term efciency and damage protection I Element sizes from 2 kW to 6 kW using 3, 6 or 9 elements provide input options from 6 kW to 54 kW, recoveries from 25 GPH to 221 GPH at 100F rise
Bonderized undercoated baked enamel nished cabinets I Brass Drain Valve I CSA/ASME temperature and pressure relief valve
DRE Gold models have surface mount temperature controls adjustable 120 to 180F. I Manual reset high-temperature cutoff
Safeguards elements and contactors from short circuits, overloading and line surges I Meets National Electrical Code requirements that non-ASME tanks must have internal fusing when current draw exceeds 48 amps
Banks of heating elements (3 elements per bank) are energized according to adjustable (1 to 20) differential set points for each bank. Helps reduce short cycling and operating costs by matching kW output to load conditions I Linear sequencing - rst bank on is last bank off I Helps reduce current surge/spikes and avoid peak demand charges I Helps reduce operating costs during low load conditions I Manual reset high-temperature cutoff
Compliance
I
Single-phase and 3-phase delta I Field-convertible voltages 3-phase to single-phase (and vice versa) except for 208V/54 kW I 277V single-phase also available
iCOMM Compatible and can be monitored from remote locations. Call 1.888.WATER02 for more information. I Plain English text and animated icons. I Displays detailed operational and diagnostic information I Fault or alert messages appear if an operational issue occurs I Last 9 fault and alert messages saved with time stamp.
Meets the standby loss requirements of the U.S. Department of Energy and current edition of ASHRAE/IESNA90.1
Control system automatically lowers the operating set point by a programmed value during user-dened time periods I Helps reduce operating costs during unoccupied or low demand periods
Two anode rods for maximum corrosion protection I Simplied circuitry, color coded for ease of service
MODEL NO.
GAL. CAP.
KILOWATTS MAXIMUM
HEIGHT
DIA.
50 80 119
54 54 54
27
See specication sheets or contact your local rep for optional KWs available.
Progressive Sequencing
I First
Incoloy sheathed heating elements are designed for rugged longlasting commercial service, and can withstand sheath temperatures up to 1500F I Each heating element has three separate heating loops, which provides more heating surface, lower watt density and maximum recovery efciency I Prewired leads provide excellent protection against oxidation and scaling I Input options from 3 kW to 90 kW, recoveries from 12 GPH to 369 GPH at 100F rise
heating element on is rst heating element off. I First heating element energized is rotated with each successive heating cycle on models with multiple heating elements. I Evens out wear between heating elements.
system automatically lowers the operating set point by a programmed value during user-dened time periods. I Helps reduce operating costs during unoccupied or low demand periods
and 3-phase 208V and 240V are eldconvertible to 3-phase I All 208V and 240V at 24 kW and below are supplied as phase-convertible units (singleto 3-phase and vice versa) I 277V single-phase also available (Contact A. O. Smith for 120V circuit availability) I International voltages also available (check with factory)
I Single-phase
Set Point adjustable 90 to 190F. - Units with multiple element contactors are sequenced on with one second delay between stages. Adjustable modulating mode is optional. I Helps reduce current surge/spikes and avoid peak demand charges. I Manual reset high temperature cutoff.
I Sequencing
Heavy-Duty Magnetic Contactors Power Circuit Fusing For System Protection Glasslined Tank, with ASME Construction CSA Certied and ASME Rated T&P Relief Valve Compliance
I
Factory-Installed Terminal Block (units with more than one contactor) Advanced Electronic Controls
I iCOMM
Compatible and can be monitored from remote locations. Call 1.888.WATER02 for more information. I Plain English text and animated icons I Displays detailed operational and diagnostic information I Fault or alert messages appear if an operational issue occurs. I Last 9 fault and alert messages saved with time stamp.
Optional Goldenrod 24-carat gold-plated elements resist lime scale adhesion and sheath temperatures up to 1500 F.
Meets the standby loss requirements of the U.S. Department of Energy and current edition of ASHRAE/IESNA90.1
MODEL NO.
GAL. CAP.
MAXIMUM KILOWATTS
3 6 18 24 36 90 90 90 90 90
IMMERSION HEATERS
1 1 2 2 2 5 5 5 5 5
HEIGHT
DIA.
5 10 20 30 40 50 65 80 100 119
20-1/2 26-1/2 27-1/4 35-3/4 45-3/4 54-3/4 50-1/2 49-1/4 58-1/4 63-1/4
28
DSE-100 DSE-120
Industrial-grade Incoloy sheathed heating elements are designed for rugged longlasting commercial service and can withstand sheath temperatures up to 1500F I Each heating element has three separate heating loops, which provides more heating surface, lower watt density and maximum recovery efciency I Pre-wired leads provide excellent protection against oxidation and scaling I Input options from 6 kW to 54 kW recoveries from 62 GPH to 554 GPH at 40F rise I Deionized models equipped with stainless steel standard elements
Close differential, immersiontype thermostat for superbly accurate temperature control I Adjustable from 140F to 185F I Manual reset, hightemperature cut-off
Safeguards elements and contactors from short circuits, overloading and line surges I Required by National Electric Code and UL when current draw exceeds 120A
Patent-pending 24K goldplated sheath plus mediumwatt density ensures even longer element life I 600% higher resistance to scale build-up, compared to Incoloy elements I Three-year warranty against failure due to lime scale build-up I Not available on deionized models
120V control circuit powered by fused transformer I Eliminates need for 120V service connection
Compliance
I
Meets the standby loss requirements of the U.S. Department of Energy and current edition of ASHRAE/IESNA90.1
Optional Goldenrod 24-carat gold-plated elements resist lime scale adhesion and sheath temperatures up to 1500F.
Single-phase and 3-phase I Single-phase 208V and 240V are eld-convertible to 3-phase I CMC models only, 208V and 240V at 24kW and below are supplied as phase-convertible units (single- to 3-phase and vice versa) I 277V single-phase also available (Contact A. O. Smith for 120V circuit availability)
MODEL NO.
CMC-6 thru 18 CMC-20 thru 54 SU-6 thru 18 SU-20 thru 54
INLET/ OUTLET
3/4 3/4 3/4 3/4
HT.
13-3/4 12 25 25
WIDTH
13 18 22-1/4 22-1/4
DEPTH
21-3/4 22-1/2 23 23
29
Dura-Power commercial electric water heaters are built to the same high-quality standards as our gas models. These are the largest commercial electric's we manufacture. Ideal for use as recovery heaters for all types of large commercial and industrial applications or for large process potable hot water requirements. They can be customized to meet any special application with the large selection of available options.
Advanced Electronic Control (All Models 150 kW and Down) Incoloy Immersion Heaters
I Heavy-duty medium watt density elements (three immersion heater) have incoloy sheathing: provide excellent protection against oxidation and scaling. The input ranges from 15kW to 3000kW. I Control and power circuit fusing to meet N.E.C. I Meets the standby loss requirements of the U.S. Department of Energy and current edition of ASHRAE/IESNA 90.1. I Heavy duty UL rated for 100,000 cycles. I Color-coded circuitry for easier servicing I Anode rods for maximum corrosion protection I Standard voltages include 208, 240, 480, 600 volt single or three-phase. I For other voltages consult factory. I Factory-installed terminal block(s) I Cabinet has baked enamel nish I Prewired element terminal leads I Temperature and pressure relief valve I 2 dial temperature gauge I Provides emergency back up energy source or winter/summer boiler operation. Can be specied with optional water to water or steam to water heat exchangers. Both single and double wall heat exchangers are available. Complete control packages can be factory-installed for hook up and run capability. I 3-Year Limited Tank Warranty I Optional 5-Year Limited Tank Warranty I If the tank should leak any time during the rst three years, under the terms of the warranty, A. O. Smith will repair or replace the heater; installation, labor, handling repair or replace the heater; installation, labor, handling and local delivery extra. THIS OUTLINE IS NOT A WARRANTY. For complete information, consult the written warranty or A. O. Smith Water Products Company. Warranty does not apply to product installed outside of the United States of America or its territorial possessions and Canada.
A. O. Smiths new propriety electronic water heater control, provides precise + or - 1F temperature control, that is ideal for industrial and food service applications where exact temperatures of hot water are needed.
Optional Goldenrod 24-carat gold-plated elements resist lime scale adhesion and sheath temperatures up to 1500 F.
I Plain Text Animated icons display detailed operational and diagnostic information. Fault or Alert messages appear if an operational issue occurs. I Low Water Cut Off Factory standard on board low water cut-off uses a remote electronic immersion type probe to prevent energizing of the elements in the event of low water condition and eliminates accidental dry ring. I Progressive Modulating (only available on units 150 kW or less) Sizes the input of available elements to match current load conditions. Rotates and lead lags element loads to provide long life and equal wear. I Economy Mode Operation (only available on units 150 kW or less) Control system automatically lowers the operating set point by a programmed value during user dened time periods. Seven-day clock may be programmed for night set back and or weekend shutdown to reduce operating cost and save money. I iCOMM Compatible Units can be monitored from remote locations. Call 1.888.WATER02 for more information. Note: Up to 150 kW only. Units above 150 kW use analog controls.
Fusing
Compliance
Magnetic Contactor(s)
Solid State Modulating Step Control (All Models 180 kW and up)
I Solid state electronic control device that modulates input to match load through progressive sequencing of steps (up to 20 steps with maximum of one per contactor).
Glasslined Tank
I Tank interior is coated with glass specially developed for use in water heaters. Tanks rated at 125 psi working pressure; 150 psi or 160 psi working pressure is optional. Vermin proof ber glass insulation reduces costly heat loss. Constructed to Section IV of ASME code, and UL standards. Tanks have channel skid base. A 4 x 6 handhole is furnished on 500, 600 and 700gallon models; 11 x 15 manhole is furnished on 800-gallon and larger sizes.
30
Options
I Tank Linings CEMENT A special formulation of cement providing excellent corrosion protection. Available on 200-gallon and larger tanks. EPOXY A solventless two component epoxy lining applied to a minimum ten-mil (.010) dry thickness. Available on 200-gallon and larger tanks. I GOLDENROD ELEMENTS Available with Optional Goldenrod Elements - All DVE/DHE models are available with the Goldenrod 24K gold plated elements (patent pending). Goldenrod Elements provide long-life and ve times the scaling resistance of standard incoloy elements. Goldenrod Elements carry a three-year warranty against failure due to scale buildup. I SPECIAL CONSTRUCTION Silicon Bronze Vessels are available for special applications or very corrosive water conditions. Consult factory for specic sizes. I STAINLESS STEEL VESSELS Are available for deionized water. Built with stainless steel under rules of Section IV of the ASME Boiler and Pressure Vessel Code for operation on deionized water having a minimum specic resistivity of 10 megohm/cm. I 150 OR 160 PSI WORKING PRESSURE Must be specied at time of order.
I 3-1/2 DIAL-TYPE PRESSURE GAUGE Factory-installed. I 3-1/2 DIAL-TYPE TEMPERATURE GAUGE Factory-installed. I 11 x 15 MANHOLE Available as option on tanks 700 gallons or smaller.
Control Options
I COPPER TUBE TANK HEATER Double wall copper tube tank heaters are designed for heating potable water with both potable or non-potable liquids or steam, and are specically engineered for installation in models DVE and DHE for dualenergy applications. Tank heaters have a positive fail-safe means of leak detection in the event of either tube failure to prevent mixture of heating medium and potable water. Singlewall heat exchangers are also available. I TERMINAL BLOCKS Allows for remote connection to building demand limiter or other functions.
I AUTOMATIC RESET HIGH LIMIT A control that in the event of high temperature, interrupts power, de-energizing elements, automatic reset. (Standard with modulating step control).
I INDICATING LIGHTS Denotes heating stage(s) in operation. Up to one light per contactor is available.
I TEMPERATURE AND PRESSURE RELIEF VALVES For working pressures other than standard; consult factory. I HORIZONTAL OR VERTICAL See specications, most gallon capacities may be obtained in vertical or horizontal construction. I CIRCULATING PUMP PACKAGE Circulating pump and piping sized to turn over entire storage capacity of tank once each hour. Recommended to optimize available water at temperature in horizontal tanks particularly where low draw conditions are anticipated. I OPTIONAL INTERNATIONAL VOLTAGES 380 and 415 volts three-phase.
All dimensions in inches VERTICAL ELECTRIC STORAGE HEATERS
I OVERRIDE SWITCHES A simple means of load control allows all or part of unit input to be controlled manually. Up to one switch per contactor is available I SAFETY DOOR INTERLOCK Prevents opening of control panel door when heater power supply is on. NOTE: Once door is opened heater may be energized if necessary for service diagnosis.
I SHUNT TRIP CIRCUIT BREAKER A safety device (circuit breaker) which disconnects power to heater in the event of over-current, high temperature or low water level, breaker must be manually reset. I CIRCUIT BREAKER A safety device which disconnects power to the heater in the event of overcurrent.
MODEL NO.
DVE-140 DVE-150 DVE-150L DVE-200 DVE-250 DVE-300 DVE-350 DVE-400 DVE-500 DVE-600 DVE-700 DVE-800 DVE-1000 DVE-1250 DVE-1500 DVE-2000 DVE-3000 DVE-5000 DVE-7500 DVE-10,000
GAL. CAP.
125 150 150 200 250 300 350 400 500 600 700 800 1000 1250 1500 2000 3000 5000 7500 10,000
MAX KW INPUT
120 150 150 180 240 300 330 390 480 600 690 780 990 1200 1500 1980 3000 3000 3000 3000
HEIGHT
83-1/2 83-1/2 59-1/2 79-1/2 93 83-1/2 95-1/2 102-1/2 97 112 124 116 116 143 155 183 217 309 330 358
WIDTH
30 30 36 36 36 42 42 42 48 48 48 54 60 60 60 66 72 78 90 102
DEPTH
37 37 43 43 43 49 49 49 55 55 55 61 67 67 67 73 79 85 97 109
MODEL NO.
DHE-200 DHE-250 DHE-300 DHE-350 DHE-400 DHE-500 DHE-600 DHE-700 DHE-800 DHE-1000 DHE-1250 DHE-1500 DHE-2000 DHE-3000 DHE-5000 DHE-7500 DHE-10,000
GAL. CAP.
200 250 300 350 400 500 600 700 800 1000 1250 1500 2000 3000 5000 7500 10,000
MAX KW INPUT
180 240 300 330 390 480 600 690 780 990 1200 1500 1980 3000 3000 3000 3000
HEIGHT
38-1/2 38-1/2 44-1/2 44-1/2 44-1/2 51 51 51 57 61 61 61 70 76 82 94 106
WIDTH
77 91 81 93 100 94 109 121 111 111 138 150 177 211 296 317 345
DEPTH
36 36 42 42 42 48 48 48 54 60 60 60 66 72 78 90 102
*Complete model number includes the desired kW at the end, minimum installation. Clearances required: 30 from front, 12 from top and 24 from right side.
*Complete model number includes the desired kW at the end, minimum installation. Clearances required: 30 from front, 12 from top and 24 from right side.
31
The A. O. Smith high efficiency condensing XP Water Heater utilizes a state-of-the-art heat exchanger and control technology to provide large volumes of hot water for demanding commercial and industrial potable hot water applications. The all stainless steel water tube heat exchanger construction allows the XP Water Heater to operate in a continuous condensing mode while maximizing longevity and delivering thermal efficiencies as high as 99% when operating in low temperature applications. A unique multi-burner design is control sequenced and modulated to produce turndown rates of up to 20:1. Precise temperature control and accurate load matching produce smooth system operation and eliminates wasteful short cycling and temperature overshooting.
Venturi-mixing gas / air ratio system - works with variable speed blower to precisely mix gas and air throughout ring range I Fully modulating capability prevents energy-stealing short cycling and provides smooth system operation with higher overall system efciencies
Complies with SCAQMD Rule 1146.2 for XWH1000 through XWH2000 and Rule 1146.1 for XWH2600 and XWH3400, and other air quality management districts with similar requirements for low NOx emissions
Large touch screen user interface Factory standard with MODBUS protocol connections I The latest in energy saving algorithms I Includes remote tank temperature control to adjust tank temperature at the water heater - modulates the water heater to maintain tank set point temperature within +/-1 degree I Water heater output control features 20:1 turndown ratio on models 2 million btuh and up, 10:1 turndown ratio on models 1.7 million btuh and down
Integrally mounted, wired, and controlled by the water heater control I Factory-sized for proper ow between water heater and storage tank I Allows 50 equivalent feet of piping between water heater and tank
Utilizes leading-edge multi-pass water tube heat exchanger to maximize heat transfer I Designed for fully condensing operation throughout the heating range I All heating surfaces are 316L stainless steel to provide a long and trouble-free service life I Saves both fuel and operating cost with every heating cycle I Impervious to thermal shock
32
Direct vent up to 100 equivalent feet of pipe Sidewall or vertical I Lower installation cost with approved CPVC / PVC venting material uses CPVC for first 10 feet and PVC thereafter I Approved for use with UL approved AL29-4C stainless steel venting materials
Required for activating warranty and assuring maximum operating performance. Contact your local sales representative or Authorized Start-Up Agent to arrange a FREE certied start-up.
Meets the Thermal Efficiency Requirements of the U.S. Department of Energy and Current Edition ASHRAE/IESNA 90.1 Up to 96% Thermal Efficiency (AHRI Certified) 5-Year Heat Exchanger Warranty
I
For complete information, consult written warranty or contact A. O. Smith Remote tank temperature sensor included I 20:1 turndown ratio on models 2 million btuh and up, 10:1 turndown ratio on models 1.7 million btuh and down I Horizontal and vertical direct and sidewall vent options up to 100 equivalent feet of piping I Approved for CPVC / PVC plastic vent materials I Meets ASME CSD-1/GE gap codes factory standard I Direct spark ignition I Factory-installed electrical disconnect I All bronze factory-mounted pump(s) I 316L stainless steel heat exchanger I ASME 160# working pressure I ASME rated pressure relief valve 125 PSI RECOVERY CAPACITIES
Models Input Rating (Btu/hr) 920,000 1,300,000 1,700,000 1,999,900 2,600,000 3,400,000 Water Flow GPH LPH GPH LPH GPH LPH GPH LPH GPH LPH GPH LPH Temperature Rise - F (C) 40 (22) 2,662 10,078 3,742 14,167 4,904 18,565 5,794 21,931 7,501 28,393 9,891 37,441 60 (33) 1,775 6,719 2,495 9,444 3,269 12,376 3,862 14,621 5,000 18,929 6,594 24,961 70 (39) 1,521 5,759 2,139 8,095 2,802 10,608 3,311 12,532 4,286 16,225 5,652 21,395 80 (44) 1,331 5,039 1,871 7,083 2,452 9,282 2,897 10,966 3,750 14,196 4,945 18,721 90 (50) 1,183 4,479 1,663 6,296 2,180 8,251 2,575 9,747 3,334 12,619 4,396 16,641 100 (56) 1,065 4,031 1,497 5,667 1,962 7,426 2,317 8,773 3,000 11,357 3,956 14,976 120 (67) 887 3,359 1,247 4,722 1,635 6,188 1,931 7,310 2,500 9,464 3,297 12,480 140 (78) 761 2,880 1,069 4,048 1,401 5,304 1,655 6,266 2,143 8,112 2,826 10,697
Other XP Features:
I
CSA certified to the ANSI Z21.10.3CSA 4.3 water heater standard I Honeywell sola control with color touch screen LCD display Inlet / outlet and remote tank temperature display Onboard Modbus communications Logs faults, run time, cycles Redundant flow and low water protection - factory installed LWCO and flow switch(s) Multi-burner sequencing models 2 million btuh and up have 4 burners; models 1.7 million btuh and down have 2 burners Redundant ignition controls should one burner fail remaining burners continue to heat Alarm buzzer
XP Options:
I
ASME HLW stamped heat exchanger(s) I Condensate neutralization kit I Vent termination kits I Skid mounted systems
33
SINGLE HEAT EXCHANGER BOILER DOUBLE HEAT EXCHANGER MODELS SINGLE HEAT EXCHANGER MODELS SINGLE HEAT EXCHANGER BOILER SINGLE HEAT EXCHANGER BOILER IN DIMENSIONS (SINGLE) Rough In Dimensions (Double) Rough In Dimensions (Single) ROUGH
Models XWH-1000 XWH-1300 XWH-2000 XWH-1700 Models XWH-2600 XWH-3400 Models XWH-1000 XWH-1300 XWH-1700 Models XWH-1000 XWH-1300 XWH-1700 Models XWH-1000 XWH-1300 XWH-1700 Dimensions mm inches mm mm Inches inches Dimensions Inches mm Inchesinches mm Inches mm Dimensions Inches mm Inches mm mm Dimensions inches inches mm mm inches inches mm inches inches mm Dimensions mm mm Flue Outlet Diameter 6 152 8 152 8 203 Flue Outlet Flue Outlet 6 152 8 6 152 8 152203 203 8 203 10203 254 Flue Outlet 8 Diameter 152 8 152 8 Diameter Flue Diameter Outlet Diameter 6 152 8 8 203 Air Intake Diameter 6 152 6 152 8 203 Air Intake Diameter 6 152 6 152 8 203 Air 6 Intake Air Intake Air Intake 8 203 8 152 203 8 203 10 6 Diameter 152 6 152 6 8 203 152 Water Inlet 2 inch NPT Diameter 2 1/2 inch NPT 254 Diameter Water Inlet 2 inch NPT 2 1/2 inch NPT Water Inlet 2 inch NPT 2 1/2 inch NPT Water Outlet 2 inch NPT 2 1/2 inch NPT NPT 3 inch NPT 4 inch Water Inlet 2 1/2 inch NPT 2 inch NPT Water Inlet Water Outlet 2 inch NPT 2 1/2 inch NPT Water Outlet 2 inch NPT 2 1/2 inch NPT Gas Inlet 2 inch 4 NPT Water Outlet 2 inch NPT 2 1/2 inch NPT 2 inch NPT Water Outlet 3 inch NPT inch NPT Gas Inlet 2 inch NPT 2 inch NPT Gas Inlet 2 inch NPT 2 inch NPT A 47 1199 49 1245 2 inch NPT 57 1448 Gas Inlet 2 inch NPT 2 inch NPT Gas Inlet 3 inch NPT A 47 1199 1199 49 1245 1245 57 1448 1448 A 47 49 57 A 1199 49 1245 57 1448 B 47 67 1702 68 A 1727 761245 1930 47 1194 49 57 1448 B 67 1702 1702 68 1727 1727 76 1930 1930 B C 67 29 67 76 737 29 68 737 29 76 737 B 1702 68 1727 1930 B 78 1981 80 2032 91737 2311 C 29 737 29 737 29 C 29 D 29 37 940737 38 29 965737 37 29 940737 C 737 29 737 29 737 D 37 940 38 96536 965 37 C 914 37 940 37940 940 D 37 E 37 23 584940 23 38 584 24 37 610940 D 940 38 965 37 940 E 23 584 23 584 24 D 22 559 22 559 22610 559 E 23 584 23 584 24 F 23 9 229 9 229 9 229610 E 584 23 9 584 24 229 610 F 9 22940 229 9 F 9 229 9 9 229 E 1016 41 1041 41229864 1041 G 34 864 34 864 34 F 9 229 9 34 229 9 864 229 G 34 864 34 864 864 34 864 F 7 864 178 6 45 152 6 152 H G 44 34 1118 45 34 1143 1143 G 34 864 34 44 864 34 1118 864 H 45 1143 1143 45 1143 1143 1118 45 J H 6 44 152 6 45 152 254 6 254 G 10 10 10152152 254 J 6 152 6 152 6 H 44 1118 45 1143 45 1143 K J 11 6 279152 11 6 279152 11 6 279152 H 102 4 102 4 279 102 K 11 279 4 279 11 J 6 152 6 11 15211 6 279 152 279 L K 12 305 11 11 279 12 11 305279 L 11 27920 279 12 J 508 19 483 19305 483 K 11 279 11 12 279 279 305 L 12 11 305 11 12 305
L 12 305 11 279 12 305 K 12 305 12 305 13 330
34
DOUBLE HEAT EXCHANGER BOILER
VERTICAL VENTING
HORIZONTAL VENTING
Direct or sidewall vent for up to 100 equivalent feet of pipe. Lower installation cost with approved CPVC/PVC venting material uses CPVC for first 10 feet and PVC thereafter. Also approved for use with UL approved AL 29-4C stainless steel venting materials. For the detailed venting instructions review the XP water heater instruction manual at www.hotwater.com.
Models
Pipe Size
XWH 1000 XWH 1300 XWH 1700 XWH 2000 XWH 2600 XWH 3400
6"
320884-000
321765-000
XWH 1000 XWH 1300 XWH 1700 XWH 2000 XWH 2600 XWH 3400
6"
321764-000
8"
320884-001
321765-001
8" 10"
321764-001 321764-002
10"
320884-002
321765-002
Please note: When direct or sidewall venting, the water heaters CSA certification requires that only the above approved vent and combustion air intake terminations be used.
FLOW RATE
RECOMMENDED FLOW RATES @ 0-12 GRAINS PER GALLON MODELS XWH 1000 XWH 1300 XWH 1700 XWH 2000 XWH 2600 XWH 3400 TEMPERATURE RISE ( T F) 25 25 25 25 25 25 GPM 70 99 129 153 198 261 PRESSURE LOSS IN FEET OF HEAD (P) 17.5 22 23 17.5 22 23
Natural Propane
14.0 14.0
3.49 3.49
4.0 4.0
1.0 2.0
ELECTRICAL REQUIREMENTS
MODEL SUPPLY FREQUENCY CURRENT VOLTAGE (HZ) (AMPS) (VOLTS) ELECTRICAL NOTES:
60 60 60 60 60 60
30 30 30 60 60 60
A dedicated, single phase, 30/60 amp circuit breaker with a grounded neutral should be provided to supply power to the water heater. A dedicated, single phase, 60/60 amp circuit breaker with a grounded neutral should be provided to supply power to the water heater.
Notes: For hard water systems with water hardness greater than 12 grains per gallon, A. O. Smith recommends a water softener be installed and maintained. The factory installed/supplied pump is sized to maintain a T of 25F through the water heater at 100% fire. In addition to the pressure loss through the water heater, the factory supplied pump is sized for an additional 50 feet of equivalent feet of piping between the water heater and a storage tank. Consult the factory for systems where the piping between the water heater and the tank exceed 50 equivalent feet.
35
The A. O. Smith high efficiency condensing XP Boiler utilizes a state-of-the-art heat exchanger and control technology to meet the rigorous demands of todays hydronic heating applications. The XP Boilers all stainless steel water tube heat exchanger construction allows the XP Boiler to operate in a continuous condensing mode while maximizing longevity and delivering exceptional energy-saving performance. Low temperature applications such as heat pump and snow melting systems can see thermal efficiencies as high as 99%, a major savings over non-condensing competitive systems. A unique multi-burner design is control sequenced and modulated to produce turndown rates of up to 20:1. Precise temperature control and accurate load matching results in smooth system operation and eliminates wasteful short cycling and temperature overshooting.
Venturi-mixing gas/air ratio system - works with variable speed blower to precisely mix gas and air throughout ring range Fully modulating capability prevents energy-stealing short cycling and provides smooth system operation with higher overall system efciencies Complies with SCAQMD Rule 1146.2 for XB1000 through XB2000 and Rule 1146.1 for XB2600 and XB3400, and other air quality management districts with similar requirements for low NOx emissions Large touch screen user interface Direct MODBUS protocol connections The latest in energy saving algorithms Outdoor reset is standard and includes remote outdoor temperature sensor - modulates the boiler to maintain desired system temperature within +/-1 degree Boiler output control features 20:1 turndown ratio on models 2 million btuh and up, 10:1 turndown ratio on models 1.7 million btuh and down Recommended for primary/secondary piping systems Integrally mounted, wired, and controlled by the boiler control Factory-sized for proper ow through the boiler Allow up to 50 equivalent feet of piping between the boiler and the primary heating system
36
I I
Utilizes leading-edge multi-pass water tube heat exchanger to maximize heat transfer Designed for fully condensing operation throughout the heating range All heating surfaces are 316L stainless steel to provide a long and trouble-free service life Saves fuel and operating cost with every heating cycle Impervious to thermal shock
Precise temperature control and accurate load matching results in smooth system operation
Direct Vent Flexibility
I I I I
XB Model Boilers
BOILERS
Direct vent up to 100 equivalent feet of pipe Sidewall or vertical Lower installation cost with approved CPVC/PVC venting material uses CPVC for first 10 feet and PVC thereafter. Approved for use with UL approved AL29-4C stainless steel venting materials
Required for activating warranty and assuring maximum operating performance. Contact your local sales representative or Authorized Start-Up Agent to arrange a FREE certied start-up.
Category IV Listed
I
Approved for use with CPVC/PVC venting material uses CPVC for rst 10 feet then PVC thereafter or a UL approved AL 29-4C Stainless Steel venting material
Meets the Thermal Efficiency Requirements of the U.S. Department of Energy and Current Edition ASHRAE/IESNA 90.1 10-Year Heat Exchanger Warranty
I
93% thermal efciency (AHRI certied) Certied to ANSI Z21.13-CSA 4.9 Honeywell sola control with color touch screen LCD display Inlet/outlet and remote loop temperature display Onboard modbus communications Logs faults, run time, cycles Redundant ow and low water protection - factory-installed LWCO and ow switch(s) Multi-burner sequencing models 2 million btuh and up have 4 burners; models 1.7 million btuh and down have 2 burners Redundant ignition controls should one burner fail remaining burners continue to heat Alarm buzzer Outdoor temperature sensor included XB MODELS - FLOW, HEAD AND TEMPERATURE RISE I 20:1 turndown models 2 million btuh Flow Rate and up, 10:1 turndown models 1.7 Temperature Rise - T F Input Output Water Models (Btu/hr) (Btu/hr) Flow million btuh and down 20 30 40 Maximum Minimum GPM 86 57 43 86 43 I Horizontal and vertical direct and LPM 324 216 162 324 162 sidewall vent options up to 100 XB-1000 920,000 855,600 26 12 7 26 7 P FT equivalent feet of piping 7.9 3.7 2.1 8 2.1 P M I Approved for CPVC/PVC plastic vent GPM 121 81 60 121 60 materials LPM 458 305 229 458 229 XB-1300 1,300,000 1,209,000 I Meets ASME CSD-1/GE gap codes 32.5 15 8 32.5 8 P FT 9.9 4.6 2.4 9.9 2.4 P M factory standard GPM 158 105 79 158 79 I Direct spark ignition LPM 598 399 299 598 299 I Factory-installed electrical disconnect XB-1700 1,700,000 1,581,000 35 14 8 35 8 P FT I 316L Stainless steel heat exchanger 10.7 4.3 2.4 10.7 2.4 P M I ASME 160# working pressure GPM 186 124 93 186 93 I ASME rated pressure relief valve 50 PSI LPM 704 469 352 704 352
XB-2000 1,999,900 1,859,907
XP Boiler Options:
I
I I I
Factory-mounted secondary pump (recommended for primary/secondary piping systems) Condensate neutralization kit Vent termination kits Skid mounted systems
XB-2600
2,600,000 2,418,000
XB-3400
3,400,000 3,162,000
37
SINGLE SINGLE HEAT HEAT EXCHANGER EXCHANGER BOILER BOILER DOUBLE HEAT EXCHANGER MODELS SINGLE HEAT EXCHANGER MODELS ROUGH ROUGH IN DIMENSIONS IN DIMENSIONS (SINGLE) (SINGLE) Rough In Dimensions (Double) Rough In Dimensions (Single)
Models Models Models XB-1000
Dimensions Inches mm Dimensions Dimensions Flue Outlet 6 Diameter 152 Flue Flue Outlet Outlet Diameter Diameter
Models XB-2000 XB-1300 XB-1300 Dimensions inches inches Flue Outlet 8 8 Diameter Air 6 Intake 6 Diameter
XB-2600
Inches mm Inches mmmm mm Inches inches inches 8 152 203 152 8 8 203 8
6 1526 6 1526
8 8
203152 152
8 10 8 10
Air Intake Air Intake Diameter Diameter Air Intake 6 152 Diameter
Water Inlet
8 203
Water Outlet Outlet Water Water Outlet 2 inch NPT Gas Inlet Gas Inlet 2 inch NPT Gas Inlet
A B C D E F G H J K L
2 inch NPT
Water Inlet
2 inch 2 NPT inch NPTOutlet 2 1/2 inch NPT Water 2 NPT inch NPT 2 inch NPT 2 inch Gas Inlet
1245 47 47 1727 67 67 57 76 29 37 24 9 34 45 6 11 12 1448 1199 1199 1930 1702 1702 737 737 737 940 610 229 864
2 1/2 2inch 1/2 NPT inch 4 inch NPT NPT 2 inch 2 NPT inch NPT 3 inch NPT 57 5757 1245 76 7691 2032 29 2937 940 37 3722 559 24 2441 1041 9 152 9 6 34 3410 254 45 102 45 4 6 6 19 483
305
A B C D E F G H J K L
47 A 67 B 29 37 23 9 34
1199 1702 737 940 584 229 864 1118 152 279 305
49 68 29 38 23 9 34 45 6 11 11
49 A 49 68 B 68 29 C 29 38 D 38 23 E 23 9 F 9 34 G 34 45 H 45 6 J 6 11 11
K
1245 471245 1194 1727 781727 1981 737 36 737 914 965 22 965 559 584 40 5841016 229 7 229 178 864 10 864 254 1143 1143 4 102 152 508 152 20
12
49 80 37 22 41 6 10 4 19 12
C E F
29737 29
965 584 229 864
37 23 9
37 9
940 940 584 584 229 229 864 864 1143 1118 1118 152 152 152 279 279 305 305
305 279
23
G 44 H 6 J
11 12
34 34 1143 44 44 152 6 6 11
279 279
K L
11
11
279 279
305
11
11
12
12
11
279 279
12
12
13
305 305
38
DOUBLE HEAT EXCHANGER BOILER
XB Model Boilers
BOILERS
VERTICAL VENTING
HORIZONTAL VENTING
Direct or sidewall vent for up to 100 equivalent feet of pipe. Lower installation cost with approved CPVC/PVC venting material uses CPVC for first 10 feet and PVC thereafter. Also approved for use with UL approved AL 29-4C stainless steel venting materials. For the detailed venting instructions review the XP boiler instruction manual at www.hotwater.com.
Models
6"
320884-000
321765-000
6"
321764-000
8"
320884-001
321765-001
8" 10"
321764-001 321764-002
10"
320884-002
321765-002
Please note: When direct or sidewall venting, the boilers CSA certification requires that only the above approved vent and combustion air intake terminations be used.
ELECTRICAL REQUIREMENTS
SUPPLY VOLTAGE (VOLTS) FREQUENCY (HZ) CURRENT (AMPS) ELECTRICAL NOTES:
MODELS (XWH)
TYPE OF GAS
XB-1000
INCHES W. C. kPa INCHES W. C. kPa
60 60 60 60 60 60
30 30 30 60 60 60
Natural Propane
14.0 14.0
3.49 3.49
4.0 4.0
A dedicated, single phase, 30/60 amp circuit breaker with a grounded neutral should be provided to supply power to the boiler. A dedicated, single phase, 60/60 amp circuit breaker with a grounded neutral should be provided to supply power to the boiler.
39
Up To 82% thermal efciency hot water supply and hydronic heating boilers
The Dura-Max series offers excellent performance and lowprole design exibility for both new construction and retrot applications. A double-row, extruded-nned copper tube heat exchanger provides exceptional heat transfer efciency. Each unit features a small footprint with a built-in draft diverter for extra clearance to simplify installation. Reliable, quiet, drawer-mounted stainless steel burners resist corrosion, improve access for easy maintenance.
All waterways 100% copper, brass or bronze... wont rust, resists thermal shock I Heavy-duty bronze castings and copper heat exchange tubes I Bronze removable return bends for easy access and inspection of individual tubes
Quiet operation and efcient, reliable design Protects against corrosion and condensation deterioration common to aluminum burners I Easy slide-out burner tray simplies cleaning and maintenance
Built-in draft diverter provides extra clearance in tight, retrot installations I Clean, compact jacket design for easy access and assembly I Cool to touch and approved for combustible oors
Unique O ring design compresses to form watertight seal positioned away from and outside the combustion chamber I Isolated location offers optimum protection and years of service without gasket leaks
Eliminates standing pilot, saves energy Includes power ON/OFF switch I Provides ame failure response in less than one second
Meets the thermal efciency and standby loss requirements of the U.S. Department of Energy and current edition of ASHRAE/IESNA90.1 5-Year Heat Exchanger Limited Warranty (Domestic hot water supply) 10-Year Heat Exchanger Limited Warranty (Hydronic heating applications)
40
Up To 82% thermal efciency hot water supply and hydronic heating boilers
Famous Burkay reliability. Because of their lightweight and compact design, they may be easily transported on a two-wheel dolly replacing large boilers in a much smaller space. Burkay models are for indoor use in installations requiring higher inputs...up to 670,000 BTU. They can be manifolded for unlimited re power.
All waterways 100% copper, brass or bronze... resists thermal shock and corrosion buildup Special design allows maximum installation exibility
Coils of tightly wound copper tubing form a unique and highly efcient combustion chamber I Optimum energy transfer achieved with integral extruded n copper-nned tubes
Meets the thermal efciency and standby loss requirements of the U.S. Department of Energy and current edition of ASHRAE/IESNA90.1 5-Year Heat Exchanger Limited Warranty (Domestic hot water supply) 10-Year Heat Exchanger Limited Warranty (Hydronic heating applications)
All dimensions in inches HW BURKAY MODELS
HT.
DIA.
DPT
SHIP WEIGHT
HT.
DIA.
DPT
SHIP WEIGHT
DB/DW-1080 1,080,000 DB/DW-1210 1,210,000 DB/DW-1350 1,350,000 DB/DW-1480 1,480,000 DB/DW-1610 1,610,000 DB/DW-1810 1,810,000
41
*Available in natural gas only Production of +DB/DW Models will be discontinued in March 2012
A. O. Smith Genesis boilers offer everything you could ask for in a non-condensing boiler. They provide the highest possible 84% thermal efciency, outstanding venting exibility, space-saving stackable design and a new, advanced Energy Management Control (EMC) system. Genesis models are available for installation indoors (GB/GW Series) or outdoors (GBO/GWO Series).
CRN
Complies with
Patent pending Controls every electrical boiler function, including pump operation and main burner ignition, delivers precise temperature management with 1F accuracy I Display panel shows current operating status and fault readings in easy-to-understand English instead of confusing numeric codes I Display also shows temperature set points, outlet temperature, current inlet/outlet differential (T) and tank temperature I Help screens assist in boiler setup and explain all control options I Includes 120V terminals for installation of secondary pump up to 1/3 HP allows control to cycle secondary pump for maximum efciency, virtually eliminates standby heat loss at the boiler
iCOMM Compatible and can be monitored from remote locations. Call 1.888.WATER02 for more information.
Multiple gas valve ring system ensures smooth operation, saves fuel and extends boiler life (Models GW/GB-300 through 750 are 2-stage ring; Models GW/GB-1000 through 1500 are 3-stage ring; Models GW/GB-1850 through 2500 are 4-stage ring) I Prevents short cycling during low demand periods, delivers maximum output when demand is high
Domestic hot water supply GW models Hydronic heating GB models Complies with SCAQMD Rule 1146.2 and other Air Quality Management Districts with similar requirements for low NOx emissions+
Meets the thermal efciency and standby loss requirements of the U.S. Department of Energy and current edition of ASHRAE/IESNA90.1 10-Year Heat Exchanger Limited Warranty (Hydronic heating applications) 42 5-Year Heat Exchanger Limited Warranty (Domestic hot water supply)
Complies with
CRN
Combustion Air Blower with Air Shutter Adjusts to the application for maximum efciency.
Finned-copper design delivers superior heat transfer and energy efciency I Self-bafing tube design assures even ow through heat exchanger I Copper is lightweight, immune to rust and thermal shock I Double-row conguration on 1,000,000 BTU input and higher...ts maximum heat transfer into minimum space
Cutaway shown is Genesis models 300 thru 750,000. Hot Surface Ignition More efcient and reliable than standing pilot. Removable Bronze or Glasslined Cast-Iron Headers For easy inspection and service of waterways.
Compliance
Two to four-Stage Firing with Separate Remote Flame Sensors For safety and extended ignitor life. Individual sensors for each stage. Pressurized Combustion System With pre-jet orice for near-perfect air/gas mixture, clean combustion, low NOx.
I
Meets the thermal efciency and standby loss requirements of the U.S. Department of Energy and current edition of ASHRAE/IESNA90.1+
43
All dimensions in inches MODELS GB/GW-300750 HOT WATER SUPPLY AND HYDRONIC BOILERS
MODEL NO.+
WATER CONN.
GAS CONN.
100
304 406 507 659 761
140
217 290 362 471 544 1-1/2 1-1/2 2 2 2 3/4 1 1 1-1/4 1-1/4
HEIGHT
WIDTH
DEPTH
INDOOR GB/GW SERIES GB/GW-300 GB/GW-400 GB/GW-500 GB/GW-650 GB/GW-750 300,000 399,900 500,000 650,000 750,000 5 6 6 8 8 30 30 30 30 30 29-1/2 35-3/4 42 51-3/8 57-3/8 41-1/2 50-1/2 56-3/4 66-1/8 74-5/8 24 24 24 24 24 414 476 526 612 702
OUTDOOR GBO/GWO SERIES GBO/GWO-300 GBO/GWO-400 GBO/GWO-500 GBO/GWO-650 GBO/GWO-750 300,000 399,900 500,000 650,000 750,000 761 1014 1268 1649 1902 304 406 507 659 761 217 290 362 471 544 1-1/2 1-1/2 2 2 2 3/4 1 1 1-1/4 1-1/4 5 6 6 8 8 41-7/8 41-7/8 41-7/8 41-7/8 41-7/8 49 55-1/4 61-1/2 70-7/8 77-1/8 27-11/16 27-11/16 414 476 526 612 702
All dimensions in inches MODELS GB/GW1000-2500 HOT WATER SUPPLY AND HYDRONIC BOILERS
MODEL NO.+
WATER CONN.
GAS CONN.
100
1008 1324 1527 1884 2138 2535
140
720 945 1091 1345 1527 1811 2-1/2 2-1/2 2-1/2 2-1/2 2-1/2 2-1/2 2 2 2 2-1/2 2-1/2 2-1/2
HEIGHT
WIDTH
DEPTH
INDOOR GB/GW SERIES GB/GW-1000 GB/GW-1300 GB/GW-1500 GB/GW-1850 GB/GW-2100 GB/GW-2500 990,000 1,300,000 1,500.000 1,850,000 2,100,000 2,490,000 10 /8 12 /10 12 /10 14 /12 14 /12 16 /14 40-1/2 40-1/2 40-1/2 43-1/4 43-1/4 43-1/4 47 57-1/2 64-1/2 78-3/4 85-1/2 99-1/2 64 74-1/2 81-1/2 95-3/4 102-1/2 116-1/2 31-3/4 31-3/4 31-3/4 31-3/4 31-3/4 31-3/4 936 1050 1274 1404 1508 1581
OUTDOOR GBO/GWO SERIES GBO/GWO-1000 GBO/GWO-1300 GBO/GWO-1500 GBO/GWO-1850 GBO/GWO-2100 GBO/GWO -2500 990,000 1,300,000 1,500,000 1,850,000 2,100,00 2,490,000 2520 3309 3818 4709 5345 6338 1008 1324 1527 1884 2138 2535 720 945 1091 1345 1527 1811 2-1/2 2-1/2 2-1/2 2-1/2 2-1/2 2-1/2 2 2 2 2-1/2 2-1/2 2-1/2 10 /8 12 /10 12 /10 14 /12 14 /12 16 /14 58-11/16 58-11/16 58-11/16 61-3/8 61-3/8 61-3/8 66 76-1/2 83-1/2 97-1/2 104-1/2 118-1/2 31-5/8 31-5/8 31-5/8 31-5/8 31-5/8 31-5/8 936 1050 1274 1404 1508 1581
+After January 1, 2012, Models will not meet SCAQMD Rule 1146.2 requirements for low NOx emissions.
44
Burkay Genesis
BOILERS
Allows clean, uncontaminated air to be drawn directly into the unit I Flue gas by-products are expelled through the wall to the outside I Sidewall or vertical I The boiler can be vented directly through an outside wall or vertically through the roof
Designed for maximum durability and serviceability I Copper is lightweight for easier handling and immune to thermal shock
Alternate thermostat terminals (24V) CSA Certied and ASME rated T&P relief valve I Factory-installed ow switch I Manual reset high limit I Blocked ue switch I Fan proving switch I Adjustable secondary pump delay I Removable headers allow easy inspection of waterways
Genesis Options
I
Vertical direct-venting with horizontal combustion air intake rear intake/top exhaust
Horizontal direct-venting with vertical combustion air intake top intake/rear exhaust
Factory-mounted and wired boiler pump for primary or secondary piping systems I CSD-1 code I New York and California code I Alarm bell I Dry contacts for any boiler failure I E.M.S. stage control adapter I Stack rack I Low water cut off I Sequencing control panel with outdoor reset for 18 boilers I Combustible oor shield I Cupro-nickel heat exchanger I Extended venting kit I CSA certied vent kits
See Installation Manual for complete venting installation instructions and maximum intake combustion air and exhaust venting distances.
45
Up to 88% efcient, hot water supply boiler with modulating re 4:1 turndown
The Art of Flexibility
The new VF Series variable re copper tube boilers are designed with one thing in mind: to provide the best value to the customer. As a result, were proud to introduce a more installation-friendly line that works well in more applications and requires less maintenance. The secret to the stunning performance of the VF Series is its exibility. The VF is capable of ring from 100% to 25% or a 4:1 turndown ratio. The boilers output is based strictly on the current system demand and required BTUs needed to maintain the desired system set point temperature. The VFs modulating capability is virtually limitless. The VF Boiler sets a high efciency standard by combining thermal efciencies up to 88% with a smoother, more energy-efcient overall system operation.
Small Size and Easy Service Small Footprints, Zero Clearance To Combustibles On Sides of Unit
I
Compact design, lightweight copper heat exchanger makes VF Series easier to move and install in limited spaces perfect for retrots I Fits in an elevator, ideal for boiler rooms with limited accessonly 30 wide I Multiple boiler systems provide increased turndown and even smoother, more efcient system operation I 4 boilers w/4:1 turndown = 16:1 total system turndown
Complies with SCAQMD Rule 1146.2 and other Air Quality Management Districts with similar requirements for Low NOx emissions
ASME rated Pressure Relief Valve Factory-Mounted Flow Switch I Low Gas Pressure Switch I All Bronze Factory-Mounted Pump (Standard on VW hot water supply models) I Digital Inlet/Outlet Temperature Read Out I Manual Reset Hi Limit I Network ready for future remote capabilities
iCOMM Compatible and can be monitored from remote locations. Call 1.888.WATER02 for more information
Category IV Listed Meets the thermal efciency and standby loss requirements of the U.S. Department of Energy and current edition of ASHRAE/IESNA 90.1
5-Year Heat Exchanger Limited Warranty (Domestic hot water supply) 10-Year Heat Exchanger Limited Warranty (Hydronic heating applications) CSD-1 Controls VF Boiler Approved Options*
*For optional boiler equipment, see VF Boiler VB and VW spec sheets.
All dimensions in inches
VW AND VB MODELS
MODEL NO.
VENT CONN.
HT.
WIDTH
DEPTH W/ PUMP
140
362 543 724 1080 1440 6 6 6 7 7 56 62 71 67 72 30 30 30 30-1/2 30-1/2 37-1/2 37-1/2 37-1/2 60-1/4 60-1/4 30 30 30 37 37 450 575 750 925 1025
VW/VB-500 VW/VB-750
500,000 750,000
1268 1901
46
VW/VB-2000
2,000,000
BOILERS
A
Combustion air intake self adjusting, no air shutter required
E
Venturi-mixing gas/air ratio system works with variable speed blower to precisely mix gas and air throughout ring range, provides good operation with supply gas pressures down to 4 WC for natural gas (8 WC for propane) and is self-adjusting for altitudes up to 6,000 feet, all while providing lowNOx emissions that meet or exceed the most stringent standards
B B
EMC-5000 Modulating Control
E A
C
Advanced pre-mix burner design precisely mixes air and gas prior to ignition for optimum performance. Complies with SCAQMD Rule 1146.2 and other Air Quality Management Districts with similar requirements for Low NOx emissions.
F
Heavy-duty ASME 160 PSI extruded nned copper tube heat exchangervertical, straight tube, two-pass design surrounds the burner with a 360 wall of copper nned tubing, making the entire heat exchanger resistant to thermal shock
D
All non-heating components are outside of the combustion and ue collection areas; only the copper n tubes are exposed to the products of combustion
G F
The sealed heat exchanger ue collection system is constructed of AL29-4C stainless steel that resists corrosive ue gases
47
Direct venting vertical and/or horizontal sidewall, with all combustion makeup air drawn from outside the building 70 Equivalent Feet Exhaust 70 Equivalent Feet Intake 90 Degree Elbows = 10 Feet 45 Degree Elbows = 5 Feet Boot Tee = 5 Feet
DIRECT VENTING
Conventional venting, vertical or horizontal sidewall 100 Equivalent Feet Max 90 Degree Elbows = 10 Feet 45 Degree Elbows = 5 Feet Boot Tee = 5 Feet
SIDEWALL VENTING CONVENTIONAL VENTING
See Instruction Manual for complete venting installation instructions and maximum intake combustion air and exhaust venting distances.
the boiler to maintain tank temperature within +/-1 I Innite boiler output control between 100% to 25% re I LED read out provides current boiler status in plain English with help screens to assist should a fault occur I Controls and monitors every electrical boiler function with onboard diagnostics
iCOMM Compatible and can be monitored from remote locations. Call 1.888.WATER02 for more information
48
BOILERS
49
Weve taken our best commercial boilers and tanks and made them available in a total system called Ac-U-Temp. Completely pre-piped and pre-wired, built to your specications and skid-mounted, Ac-U-Temp systems streamline installation and reduce labor costs. Once on-site, the installer simply connects the ue, gas, electric supply, cold water make-up and hot water supply.
Tank Capacities
I
Standard tank sizes from 80 to 1,000 gallons I Custom tanks to 10,000 gallons
All systems are built to order to meet your specications I Many type of boiler and tank combinations are available
Factory-engineered and assembled to assure proper pipe, pump and wired sizing I Systems are pre-piped and wired to guarantee maximum system efciency
Multi-Boiler Systems
I
Simplies Installation
I
Installer simply connects the ue, gas, electric supply, cold water make-up and hot water supply
High recovery systems that can meet any hot water demand I Systems can be designed to provide 50%100% back-up I Boilers can be On & Off-red or sequenced to meet changing system demands I Sequenced multi-boiler systems that employ relatively small storage tanks are ideal for applications with constant, yet uctuating hot water demands
Each tank is specially designed with tank opening locations that provide maximum tank draw efciency and eliminate any unnecessary piping and connections I Standard Ac-U-Tanks are factory jacketed and insulated (Bare tanks are also available)
Multi-Tank Systems
I
Electric Back-Up
I
Heavy-duty electric water heater elements and controls can be specied for up to 3,000 kW for 100% electric back-up I Provides hot water even during natural gas curtailments
For easy shipping Larger systems may be shipped on a split skid that is easily assembled during installation
Factory Hydrostatic And Fire-Tested Before Shipping 5-Year Heat Exchanger Module And 5-Year Limited Tank Warranty
50
Ac-U-Temp
Other Features
I
Options
I I
CSA Certied and ASME rated T&P relief valve I Tank temperature sensor I Tank thermometer I Isolation valves (Reliable ball valves) I 125 PSI tank construction
All-bronze circulating pump Sequencing control panel for multi-boiler systems I 150 PSI tank construction I 11 X 16 manhole for easy maintenance I Cement and epoxy tank linings available to meet special specications I Optional dual energy source capability
Shown below are standard Ac-U-Temp congurations* . Custom designs are available to meet specic needs.
*The four examples shown feature the Genesis boiler with various piping congurations with a jacketed insulated tank.
51
Designed for use as a hot water boiler for space heating applications
All vessels manufactured to applicable ASME code Vessels with maximum working pressure of 160 PSI or less (standard design is for 125 PSI) at 240F maximum temperature bear the H symbol
Heavy-duty medium-watt density elements (3 per immersion heater) I Incoloy sheathing provides excellent protection against oxidation and scaling I Inputs range from 450 kW to 6,000 kW
Meets National Electrical Code 100,000A I.C. cartridge-type fuses protect all elements and contactors
Permits manual starting and stopping of heater by interrupting power to the control circuit I Pilot light indicates when control circuit is energized
Heavy-Duty UL-Rated Magnetic Contactors Rated For 100,000 Low Water Cutoff
I
Probe type, electric low water cutoff prevent energizing of elements in the even of low water condition
Solid state modulating step control modulates heat input to match load
MODEL NO.
NW-37 NW-60 NW-96 NW-150 NW-220 NW-334 NW-400 NW-500 NW-670
GAL. CAP.
37 60 96 150 220 334 400 500 670
KILOWATTS MAXIMUM
180 300 480 720 1140 1740 2100 2580 3300
HT.**
42 57 69-1/2 69-1/2 71 99 90-1/2 90-1/2 96-1/2
WIDTH
32 32 36 54 60 60 66 72 78
DEPTH
30 30 38 44 50 50 56 62 68
BOILER DRAIN
1 1 1-1/4 1-1/2 1-1/2 2 2 2 2
52
NOTE: For boilers 3400 kW to 6000 kW, consult factory. *All ttings under 4 will be threaded type. All ttings 4 and larger will be anged. **Where overall height is a problem, a larger diameter vessel with a reduced height may be furnished.
Designed for utilizing steam or high temperature boiler water as an energy source
These skid-mounted water heater systems are completely assembled and packaged for use. All components are sized, piped and checked at the factory before shipment. HWG systems save labor and time, requiring only connection to heat source. Packages include pressure regulators, temperature regulators, steamtraps, strainers and other custom items such as standard or optional features. Tank and heat exchanger capacities will closely match those now available, 80 through 12,500 gallons and 0.9 through 214 square feet of heat transfer.
Insulation
I
Additional Features
I I
Models are insulated with berglass to meet the most current ASHRAE standards
Integral Pump
I
Steam Units
I
Standard steam trim consists of temperature control valve, inlet and auxiliary steam traps, inlet and auxiliary strainers, steam pressure gauge with siphon, vacuum breaker and air vent
ASME Code (Section IV) All copper recirculation with two bronze ball valves I Flush-mounted temperature gauges and pressure gauges I National Board Stamped I CSA Certied and ASME rated T&P relief valve I Heating coil Section VIII of ASME code
5-Year Limited Tank Warranty And 1-Year Limited Coil Warranty Options
I
Boiler Units
I
Standard boiler water trim includes temperature control valve and boiler water temperature gauge
Cathodic Protection
I
Standard systems employing glass, cement or epoxy-lined tanks are tted with magnesium anodes to help prevent corrosion
Gallon Sizes
I
HWG models are available from 140 gallons to 12,500 gallons in both vertical and horizontal congurations
Storage Tanks: 150# through 160# PSI working pressure, ASME Section VIII construction, 4 X 6 handhole, 11 X 15 manhole, cement, epoxy or galvanized linings I Water To Water: Pilot (spring, air, temperature) operated temperature regulator, bypass loop in boiler water line for regulator isolation I Steam To Water: Pilot (spring, air, temperature) operated temperature regulator, bypass loop in steam line for temperature regulator, vacuum breaker
53
A. O. Smiths HWI models are available for operation with steam or boiler water as the energy source. They are factory assembled with components sized, piped and checked at the factory before shipment. HWI models are all space saving vertical models.
Control Features
I
Single Point WiringSingle 120V connection, controls including integral circulation I On/Off SwitchAllows local on/off for service I Temperature ReadoutLED readout of water temperature I PID Temperature ControlModulates electrical control valve I Closes main valve if over temperature conditions exist I Remote Temperature Signal I Two-Wire RS485 Communication (MODBUS or ASCII)
For additional information please call the factory with the following:
I I
Required gallons per hour recovery needed Temperature rise needed; for example40 to 140 I Single or Double-Wall Coil I If steam is the energy source, what is the steam pressure? For example15 psi, 30 psi, etc. I If boiler water is the energy source, what is the minimum boiler water temperature? For example - 180, 140, etc. Note: Orders cannot be processed until the above required information has been provided.
54
55
Custom Small and Large Volume Storage Tanks Models (T, TL, TN ,TJ, TJV, TJH, TJVT)
These storage tanks are ideal for use with gas-red copper heat exchanger equipment and other A. O. Smith hot water systems for storage of any potable water at temperatures of 180F or lower. Sizes range from 80 to 12,500 gallons and custom models are available with special linings, heating coils (single-or double-wall), and accessories.
Glasslined Tank
I
Internal surfaces exposed to water are glasslined per ASME, HLW procedures using an NSF approved glasslining compound
Except for TJ-80 (vertical only) and TL-500 (horizontal only) Tanks meet R12.5 minimum thermal insulation requirements of the U.S. Department of Energy and Current Edition of the ASHRAE/IESNA 90.1 Magnesium anodes help extend tank life Standard on TJV/TJH jacketed tanks; 100, 125, 150 & 160 PSI maximum working pressure available
Jacketed Tanks
I
Anodic Protection
I
ASME Construction
I
Manifold kits Flexible R-11 jackets for eld installation I Manholes/Handholes I Factory-mounted temperature or pressure gauges I Extended warranties I Lifting lugs I Military specications
Cement formulation provides excellent corrosion protection; available on 200-gallon and larger sizes I Epoxy lining is suitable for cold or hot water storage; available on 200-gallon and larger sizes
Other Constructions
I
Black steel, stainless and silicon bronze tanks are available for extreme severe or special applications; ASME is standard
56
STORAGE TANKS
Desired temperatures in A. O. Smith custom-lined hot water storage tanks can be maintained with special copper tube heating elements. Available for use with steam or boiler water, single- or double-wall construction.
MODEL NO.
T-80 STD T-80 ASME T-120 STD T-140 ASME T-200 STD T-200 ASME T-250 ASME T-350 STD T-350 ASME
GAL.
80 80 120 140 200 200 250 350 350 400 500 500 500 750 1000
T-400 ASME TL-500 ASME TN-500 ASME T-500 ASME T-750 ASME T-1000 ASME
MODEL NO.
TJ-80 STD TJ-80 ASME TJV-120 ASME TJV-120 M TJV-140 ASME TJV-200 ASME TJV-200 M TJV-250 ASME TJV-350 ASME TJV-400 ASME TJVT-500 ASME TJV-500 ASME TJV-750 ASME TJV-1000 ASME
GAL.
80 80 119 119 140 200 175 250 350 400 500 500 750 1000
Cement, epoxy or glass linings I Black steel tanks, stainless steel tanks, silicon bronze tanks I Military specications I Manholes I Handholes I Lifting lugs I Steam or hot water tank heaters I Special and additional tank openings I Ring and leg bases I Horizontal tank saddles I Factory-mounted temperature or pressure gauges
MODEL NO.
TJH-200 ASME TJH-250 ASME TJH-350 ASME TJH-400 ASME TJHF-500 ASME TJH-500 ASME TJH-750 ASME TJH-1000 ASME
GAL.
200 250 350 400 500 500 750 1000
DIM.
36 X 77 36 X 90 42 X 93 42 X 99 40 X 94 54 X 79 54 X 110 54 X 143
PRESSURE
125 125 125 125 125 125 125 125
For complete specications on A. O. Smith Commercial Storage Tanks, consult Specication Sheets at www.hotwater.com.
57
A. O. Smiths reputation for innovation continues to soar with our most complete line of products yet. With the trademark blend of innovative technology and energy-efcient solutions, our comprehensive line is the natural source for everything from the smallest commercial installation all the way up to the largest multi-structure complex. We offer over 500 different commercial models, including gas red, oil-red and electric congurations, ranging in capacities from 5 to 10,000 gallons, with input range from 50,000 BTU to the equivalent of 2,500,000 BTU. Through an inspired blend of innovation, efciency and years of expertise, A. O. Smith continues to set the industry standard for performance and quality of water heaters, boilers and storage tanks.
58
Stratford, Ontario Renton, Washington McBee, South Carolina Ashland City, Tennessee Juarez, Mexico
59
A. O. Smith Water Products Company 500 Tennessee Waltz Parkway Ashland City, TN 37015 PH 800. 527.1953 www.hotwater.com
A. O. Smith reserves the right to make product changes or improvements at any time without notice.
OCTOBER 2011
2011 A. O. Smith
Printed in U.S.A.