Documenti di Didattica
Documenti di Professioni
Documenti di Cultura
com
AEXIO SOLUTIONS
Intelligent Optimization
www.infovista.com
VIP Analysis Subscriber KPI Analysis Phone Profiling Smart Phone Analysis*
* - GPEH Only
Network Optimization
Call Search
Task Manager
INSTALLATION GUIDE
System Requirements for Xeus TMR:
Components
Computer and Processor Memory
Requirements
Pentium i5 or higher. 2 Gigabyte (GB) and above. *Recommended 8GB of RAM for best performance.
Hard Disk
Third-party Operating System
Task Manager for manual queue parsing and autoscheduling (TAM Task Automation Module)
1. 2. 3.
Update Network Data prior of importing TMR files. This is important for correct Cell Name Matching Collect TMR files Plan import strategy. Recommended 3 hours data for one RNC for each import
Collect GPEH Event based on analysis Scenario. Refer TMR Quick Guide Appendix 1c for list of event
Important: Include RRC Measurement & NBAP Radio Link Setup Request for Geo-Analysis
3. The PCHR log will have either UCHR or PCHR word in the filenames e.g.
RAN R12 & R13 BSC0121_[PCHR]02Log20111010231746(DST)_20111010232743(DST).log.zip
Important: For R11 and above, please ensure that the file name has PCHR. File with CHR string alone does NOT contain the performance call log and not supported in Xeus Pro.
4. Enable the CHRs Field If one of the fields is not enabled in the CHRs, use the following command to enable it: 1. In the LMT tool, execute the command SET UCHRCTRL (R11&above) in the Command Input field. 2. Click the SELECT ALL check box in the Type option drop down lists. 3. Run the command through a batch file only: Huawei R11 & above
SET UCHRCTRL:STATETYPE=ABNORMAL_ONLY-1&NORMAL_ONLY-1, DOMAINTYPE=CS_ONLY-1&PS_ONLY-1, FLOWTYPE=CONN_SETUP-1&RAB-1&DCCC-1&SHO-1&HHO-1&SYS_HO_OUT1&RRC_RELEASE-1&STAT-1&NET_OPT-1, RRCCAUSE=ORIGINATING_CONVERSATIONAL_CALL-1&ORIGINATING_STREAMING_CALL-1&ORIGINATING_INTERACTIVE_CALL1&ORIGINATING_BACKGROUND_CALL-1&ORIGINATING_SUBSCRIBED_TRAFFIC_CALL-1&TERMNT_CONVERSATIONAL_CALL-1&TERMNT_STREAMING_CALL-1&TERMNT_INTERACTIVE_CALL1&TERMNT_BACKGROUND_CALL-1&EMERGENCY_CALL-1&INTER_RAT_CELL_RESELECTION-1&INTER_RAT_CELL_CHG_ORDER-1®ISTRATION-1&DETACH1&ORIGINATING_HIGH_PRIOR_SIG-1&ORIGINATING_LOW_PRIOR_SIG-1&CALL_RE_ESTAB-1&TERMNT_HIGH_PRIOR_SIG-1&TERMNT_LOW_PRIOR_SIG-1&TERMNT_CAUSE_UNKNOWN1&MBMS_RECEPTION-1&MBMS_PTP_RB_REQ-1;
INPUT
Cell Matching File Decoder GPEH, PCHR Megamon Logs Geolocating & Binning Statistics Calculation
Plot Creation
Output Plots (MapInfo Tables)
Copyright 2013 InfoVista S.A. All rights reserved.
10
Allow Filtering by Call End type or Call Messages to reduce output database size Set output database and summary parsing report name and location Enable Geo-Analysis to geolocating call position
11
www.infovista.com
QOS ANALYSIS
Higher QOS through analysis & comprehensive troubleshooting of abnormal events
Copyright 2013 InfoVista S.A. All rights reserved.
Good Poor
Cell RF Classification
13
Cell Utilization
14
Throughput Analysis
Overall Throughput Analysis
15
16
www.infovista.com
18
19
Phone Profiling
20
21
22
23
www.infovista.com
LIVE GEO-ANALYSIS
Swiftly Geo-Locate calls & pin-point areas that require optimization
25
26
User Positioning
User Positioning on Normal/Abnormal Calls
27
www.infovista.com
NETWORK OPTIMIZATION
Increase optimization efficiency through detailed neighbor optimization , pilot pollution & coverage analysis
Copyright 2013 InfoVista S.A. All rights reserved.
Neighbor Optimization
User-definable parameter for neighbor optimization algorithm
29
Pilot-pollution analysis
30
Polluted Cell
31
32
www.infovista.com
SUPPORTING FEATURES
34
35
www.infovista.com
3. Xeus Pro user can work locally on the workstation with the parsed datasets
Workstation
4. User can copy the parsed datasets to local machine to work on them offline
Copyright 2013 InfoVista S.A. All rights reserved.
37
Memory
Memory,
Hard Drive
Drive Controller
configurations
38
TAM WORKSTATION
LAN
Gigabit Ethernet LAN
TAM WORKSTATION
TAM WORKSTATION
Copyright 2013 InfoVista S.A. All rights reserved.
39
40
Measurement Chart
41
42
ZTE CTS log internal message of the call Layer 3 Messages & Events Measurement Chart
43
44
www.infovista.com
Worldwide Headquarters InfoVista S.A. 6, rue de la Terre de Feu 91952 Courtaboeuf Cedex France
Americas Headquarters InfoVista Corporation 12950 Worldgate Drive, Suite 250 Herndon, VA 20170 United States Tel: +1 703 435 2435 Fax: +1 703 435 5122
Asia-Pacific Headquarters InfoVista (Asia-Pacific) Pte Ltd Block 750C, #03-16/17, Chai Chee Road TechnoPark@Chai Chee Singapore 469003 Tel: +65 6449 7641 Fax: +65 6449 3054