LENI (Lighting Energy Numerical Indicator) Typical Office with Fluorescent and only a Switch Design level aspiration

Calculation Level Number of Luminaires Input Power of Luminaire Maintenance Factor Room Height Luminaire Type Luminaire Install Height Light Source Colour Temperature Colour Rendering Area Running Hours per Day Running Days per Week Running Weeks Per Year Calculated Total Td Total Number of Hours in a Year Ep (Allowance w/m) Pl (Energy Used in Room Including Losses) Fo (Occupancy Factor (PIR)) Fd (Daylight Factor (Day light Dimming)) Fc (Constant illuminance (Under Running)) Td (Day Time Hours, based on Table 44) Tn (Day Time Hours, based on Table 44) Ep (Parasitic Energy Use (Controls)) kWh (day) kWh (night) LENI (Lighting Energy Numerical Indicator) Lighting Energy Limit (Based on 500 Lux 2500 Hours per Year (Table 44) Editable Cells Non-Editable Cells 500 528 30 30.5 0.8 2.8 D/ID 2.3 Fluorescent 4000K 80 92.16 10 5 50 2500 8760 0 915 1 1 1 2164 336 0 1980.06 307.44 24.82096354 20.82 Kelvin Ra m Hours Days Weeks Hours Hours w/m w Factor Factor Factor Hours Hours Controls Energy Usage (kWh/year) kWh/m/Year kWh/m/Year kWh/m/Year kWh/m/Year Meters (1x28w luminaire) Standard (over lit for 2 years) Meters Average Lux across the Space Average Lux across the Space

LENI (Lighting Energy Numerical Indicator) Typical Office with Flourescent with Control System ( PIR / Daylight / Constant Lumen design) Design level aspiration Calculation Level Number of Luminaires Input Power of Luminaire Maintenance Factor (maintains calculated level) Room Height Luminaire Type Luminaire Install Height Light Source Colour Temperature Colour Rendering Area Running Hours per Day Running Days per Week Running Weeks Per Year Calculated Total Td Total Number of Hours in a Year Ep (Allowance w/m) Pl (Energy Used in Room Including Losses) Fo (Occupancy Factor (PIR)) Fd (Daylight Factor (Day light Dimming)) Fc (Constant illuminance (Under Running)) Td (Day Time Hours, based on Table 44) Tn (Day Time Hours, based on Table 44) Ep (Parasitic Energy Use (Controls)) kWh (day) kWh (night) LENI (Lighting Energy Numerical Indicator) Lighting Energy Limit (Based on 500 Lux 2500 Hours per Year (Table 44) Editable Cells Non-Editable Cells 500 475 30 30.5 0.72 2.8 D/ID 2.3 LED 4000K 80 92.16 10 5 50 2500 8760 0.3 915 0.8 0.8 0.9 2164 336 242.19648 1140.51456 177.08544 16.924875 20.82 Kelvin Ra m Hours Days Weeks Hours Hours w/m w Factor Factor Factor Hours Hours Controls Energy Usage (kWh/year) kWh/m/Year kWh/m/Year kWh/m/Year kWh/m/Year Meters (1x28w luminaire) Constant illuminance Design Factor Meters Average Lux across the Space Average Lux across the Space

LENI (Lighting Energy Numerical Indicator) Typical Office with Control System (LED / PIR / Daylight / Constant Lumen design) Design level aspiration Calculation Level Number of Luminaires Input Power of Luminaire Maintenance Factor (maintains calculated level) Room Height Luminaire Type Luminaire Install Height Light Source Colour Temperature Colour Rendering Area Running Hours per Day Running Days per Week Running Weeks Per Year Calculated Total Td Total Number of Hours in a Year Ep (Allowance w/m) Pl (Energy Used in Room Including Losses) Fo (Occupancy Factor (PIR)) Fd (Daylight Factor (Day light Dimming)) Fc (Constant illuminance (Under Running)) Td (Day Time Hours, based on Table 44) Tn (Day Time Hours, based on Table 44) Ep (Parasitic Energy Use (Controls)) kWh (day) kWh (night) LENI (Lighting Energy Numerical Indicator) Lighting Energy Limit (Based on 500 Lux 2500 Hours per Year (Table 44) Editable Cells Non-Editable Cells 500 460 25 36 0.72 2.8 D/ID 2.3 LED 4000K 80 92.16 10 5 50 2500 8760 0.3 900 0.8 0.8 0.9 2164 336 242.19648 1121.8176 174.1824 16.6905 20.82 Kelvin Ra m Hours Days Weeks Hours Hours w/m w Factor Factor Factor Hours Hours Controls Energy Usage (kWh/year) kWh/m/Year kWh/m/Year kWh/m/Year kWh/m/Year Meters LED Constant illuminance Design Factor Meters Average Lux across the Space Average Lux across the Space

Potrebbero piacerti anche