Sei sulla pagina 1di 2

Model VCS

API/IP 1581 5th Edition Category M, Type S


PECOFacet VERTICAL TWO-STAGE COALESCER SEPARATORS MEET THE FIFTH EDITION OF API/IP 1581, CATEGORY "M", TYPE "S", PERFORMANCE SPECIFICATIONS Category M Coalescer Separator housings are for Military JP-8 or JP-5 fuel. Type S qualifications can be used at all filtration points in an aviation fueling system. Type S is meant to be used at filtration points where significant levels of water and dirt in the product can be expected. PECOFacet Model VCS vertical coalescer separator housings fully comply with EI 1581, Category M, Type S requirements. RELIABLE PERFORMANCE PECOFacet coalescer separators are the result of over 70 years of continuous research and development to meet the ever demanding performance requirements in the aviation fuel handling industry. This, along with proven field performance, demonstrates PECOFacet's ability to provide quality products that meet current specifications as well as specific customer requirements for installations in refineries, bulk storage terminals, heliports, airports, etc. STANDARD HOUSING DESIGN EI 1596 Design & Construction Welded carbon steel construction other materials available on request ASME Code, Section VIII construction, stamped and certified Design pressure: 150 psi @ 250 F other design pressures available on request Inlet, outlet and drain connections permanently marked Choice of rod or screw base coalescer cartridge mounting styles Interior: Epoxy coated (MIL-PRF-4556) Exterior: Prime coated Swing bolt head closures Buna-N o-ring closure seal Knife edge cartrige mounting seals Headlift furnished on 18" (457 mm) OD and larger Spider plate attached to vessel wall Slopping cartridge plate to drain connection 4" inlet/outlet cleanout/inspection connections (when permitted by design) Connections provided for options listed below

2009 PECOFacet PECOFacet has a policy of continuous product research and development and reserves the right to change design and specifications without notice.

Housings

www.pecofacet.com

OPTIONS Automatic air eliminator with check valve* Pressure relief valve* Differential pressure gauge* Pilot control valve Pilot tester Water slug control valve Electrical water-level alarm Water drain valves Liquid level gauge Blind cover for pilot control mounting flange Immersion heaters Sampling probes Working platform and ladder
(* Mandatory for 5th Edition)

d e
DIMENSIONS
a

MODEL1
in

b mm in mm in

c mm in

d mm in

e mm

FLOW RATE
gpm lpm

HOUSING LIQUID VOLUME


g l

HOUSING DRY WEIGHT


lbs kg

VCS-222-116** VCS-328-218** VCS-433-224** VCS-543-243 VCS-556-340 VCS-656-344 VCS-756-440 VCS-856-444 VCS-956-540 VCS-1056-544 VCS-1256-644 VCS-1356-744 VCS-1656-844

16 20 22 26 26 26 28 30 32 34 36 40 42

406 508 559 660 660 660 711 762 813 864 914 1016 1067

66 73 80 103 109 109 114 115 115 117 123 124 129

1683 1867 2045 2629 2781 2781 2902 2921 2940 2985 3143 3169 3296

20 21 21 9 9 9 10 10 10 10 11 11 12

508 533 552 229 229 229 254 254 254 254 279 279 305

10 12 14 16 16 16 17 19 20 22 24 26 28

254 324 362 406 406 406 445 495 527 565 616 673 711

24 28 30 36 36 36 45 46 46 48 55 46 66

610 711 762 914 914 914 1143 1168 1168 1219 1397 1422 1676

85 173 260 474 609 730 852 974 1096 1218 1461 1583 1944

322 655 984 1794 2305 2763 3225 3687 4149 4611 5530 5992 7359

35 65 90 165 180 180 210 250 285 320 385 465 530

132 246 341 625 681 681 795 946 1079 1211 1457 1760 2006

525 750 900 1200 1225 1250 1525 1675 1800 1875 2575 2600 3000

238 340 408 544 556 567 692 760 816 850 1168 1179 1361