S7-400H - CPU 414H

Overview

CPU for SIMATIC S7-400H and S7-400F/FH. Can be used in high availability S7-400H systems Can be used with F-runtime license and F-compatible CPU in failsafe S7-400F/FH systems With integrated PROFIBUS DP master interface With 2 slots for sync modules

Application
The CPU 414-4H is compatible with the SIMATIC S7-400H and S7-400F/FH. It allows a faulttolerant S7-400H system to be configured. It can also be used for the failsafe S7-400F/FH automation system in conjunction with an F-runtime license. The integrated PROFIBUS DP interface supports direct connection to the PROFIBUS DP fieldbus as master.

Design
The CPU 414-4H includes:

High-performance processor: The CPU achieves instruction execution times as low as 60 ns per binary instruction 1.4 MB RAM (700 KB for program, 700 KB for data); load memory for user programs and parameter assignment data of the S7-400H F/FH automation system; high-speed RAM for user program components applicable to execution Memory card: for expansion of the integrated load memory. In addition to the program, the information contained in the load memory includes parameter assignment data for the S7-400H F/FH

Price list version 01.10.2007 (Version 25.00)

Seite 1 von 7

CA 01

S7-400H - CPU 414H

and therefore requires approximately twice as much space. The result is: Integrated load memory is not adequate for large programs so that a memory card is often required. RAM and FEPROM cards (FEPROM for retentive storage) are available. Flexible expansion capability: Max. 65K digital, 4K analog I/Os Multipoint interface MPI: The integrated MPI makes it possible to establish a simple network with up to 32 nodes, at a data transmission rate of up to 187.5 kbps. The CPU can establish up to 64 connections to nodes on the communication bus (C-bus) and the MPI. Note: When PROFIBUS DP and MPI interfaces are operated simultaneously, only the following bus connector can be connected to the MPI: With a socket: 6ES7 972-0BB41-0XA0 Without a socket: 6ES7 972-0BA41-0XA0 Mode selector: Designed as a key-operated switch. Access authorizations can be restricted by means of the removable mode selector. Diagnostics buffer: The last 120 fault and interrupt events are retained in a FIFO buffer for diagnostics purposes Real-time clock: CPU diagnostics messages are date-stamped and time-stamped. PROFIBUS DP interface: The CPU 414-4H with PROFIBUS DP master interface supports a distributed automation configuration with high speed and simple handling. From the user's point of view, the distributed I/O is treated as central I/O (same configuring, addressing and programming). Note: When PROFIBUS DP and MPI interfaces are operated simultaneously, only the following bus connector can be connected to the MPI: With a socket: 6ES7 972-0BB41-0XA0 Without a socket: 6ES7 972-0BA41-0XA0

Function

Block protection: A password concept also protects the user program from unauthorized access as well as the keyswitch. Integrated HMI services: The user only has to specify the source and destination of the data with HMI devices. The data are then transported cyclically and automatically by the system. Integrated communication functions: PG/OP communication Expanded communication (simple and high-availability)

Configurable Attributes
The STEP 7 "hardware configuration" tool and the installed S7-400H options package are used to configure the features and response of the S7-400H, including the CPUs, for example:

Multipoint interface MPI: Definition of node addresses Startup/cycle behavior Stipulation of the maximum cycle time and communication load Address allocation: Addressing of I/O modules Retentive area: Definition of the number of retentive bit memories, counters, timers, data blocks, and clock memories Protection level: Definition of access authorizations to program and data

Price list version 01.10.2007 (Version 25.00)

Seite 2 von 7

CA 01

S7-400H - CPU 414H

System diagnostics: Definition of the handling and scope of diagnostics messages Timed interrupts: Setting of periods Configuration of H stations

Safety-related functions
The F-runtime license can be used to compile the failsafe F user program and run it on the CPU. A license is required for each S7-400F/FH system. 2 TV stickers are included.

Reporting functions

Status and fault indicators: LEDs indicate internal and external errors and operating modes such as RUN, STOP, Startup, "Master mode, redundancy error, test function, etc. Test functions: The PG can be used to display signal states in program execution, modify process tags irrespective of the user program, read out the contents of stack memories, run separate program steps and inhibit program components. Information functions: The PG can be used to provide the user with information about the memory capacity and operating mode of the CPU, and the current utilization of the working and load memories.

Technical specifications (MyMMP)


6ES7 414-4HJ04-0AB0 Supply voltages Rated value DC 24 V Voltages and currents Feeding of external buffer voltage to CPU Current consumption from backplane bus DC 5 V, max. Power loss, typ. Backup battery Buffer current, typ. Buffer current, max. Memory Type of storage RAM integrated (for program) integrated (for data) expandable Load memory expandable FEPROM expandable FEPROM, max. integrated RAM, max. expandable RAM expandable RAM, max. Backup present with battery without battery CPU/blocks DB Number, max. Size, max. FB Number, max. Size, max. 2,048 64 KByte 4,095; DB 0 reserved 64 KByte Yes Yes; All data No 700 KByte 700 KByte No Yes; with Memory Card (FLASH) 64 MByte 256 KByte Yes; With Memory Card (RAM) 16 MByte 550 A 1,530 A Yes

5 to 15 VDC 2A 4.5 W

Price list version 01.10.2007 (Version 25.00)

Seite 3 von 7

CA 01

S7-400H - CPU 414H

FC Number, max. Size, max. OB Size, max. Nesting depth per priority class CPU/processing times for bit operations, min. for word operations, min. for fixed point arithmetic, min. for floating point arithmetic, min. Times/counters and their remanence S7 counter Number Remanence adjustable lower limit upper limit preset Counting range lower limit upper limit IEC counter present Type S7 times Number Time range lower limit upper limit IEC timer present Type Data areas and their remanence Flag Number, max. Remanence available Address area I/O address area Inputs Outputs of which, distributed MPI/DPinterface, inputs MPI/DP interface, outputs DP interface, inputs DP interface, outputs Process image Inputs, adjustable Outputs, adjustable Inputs, preset Outputs, preset Subprocess images Number of subprocess images, max. Digital channels Inputs Outputs Inputs, of which central Outputs, of which central 65,536 65,536 65,536 65,536 8 8 KByte 8 KByte 1,024 Byte 1,024 Byte 8 KByte 8 KByte 2 KByte 2 KByte 6 KByte 6 KByte 8 KByte Yes; MB 0 to MB 8191 Yes SFB 2,048 10 ms 9,990 s Yes SFB 2,048 Yes 0 2,047 From Z 0 to Z 7 0 999 24 64 KByte 2,048 64 KByte

0.06 s 0.06 s 0.06 s 0.18 s

Price list version 01.10.2007 (Version 25.00)

Seite 4 von 7

CA 01

S7-400H - CPU 414H

Analog channels Inputs Outputs Inputs, of which central Outputs, of which central Hardware config. Central devices, max. Expansion devices, max. Multicomputing IM Number of connectable IMs (total), max. Number of connectable IM 460s, max. Number of connectable IM 463s, max. Number of DP masters integrated via IM 467 via CP Mixed mode IM + CP permitted via interface module Number of operable FMs and CPs (recommended) FM CP, point-to-point CP, LAN Time Clock Hardware clock (real-time clock) buffered and synchronizable Operating hours counter Number Clock synchronization supports S7 message functions Number of login stations for message functions, max. Test commissioning functions Diagnostic buffer present Number of entries, max. adjustable preset Communication functions PG/OP communication Global data communication supported S7 basic communication supported S7 communication supported as server as client Useful data per job, max. S5-compatible communication supported Useful data per job, max. Standard communication (FMS) supported Yes; Via CP and loadable FB Yes; via CP and loadable FC 8 KByte Yes Yes Yes 64 KByte No No Yes 3,200 Yes 120 Yes 8 Yes Yes 32; Limited due to number of slots and number of connections 32; Limited due to number of slots and number of connections 32; limited due to number of slots and number of connections 2 0 10 No; IM 467 cannot be used jointly with CP 443-5 Ext. 0 6 6 6; IM 463-2 4,096 4,096 4,096 4,096

1 21 No

Yes

Price list version 01.10.2007 (Version 25.00)

Seite 5 von 7

CA 01

S7-400H - CPU 414H

Number of connections overall 1st interface Physics isolated Functionality MPI DP master DP slave MPI Number of connections Services PG/OP communication Global data communication S7 basic communication S7 communication Transmission speeds, max. DP master Number of connections, max. Services PG/OP communication S7 basic communication S7 communication S7 communication, as client S7 communication, as server equidistance support Activation/deactivation of DP slaves direct data exchange (cross traffic) Transmission speeds, max. Number of DP slaves, max. Address area Inputs, max. Outputs, max. Useful data per DP slave Inputs, max. Outputs, max. 2nd interface Physics isolated Functionality DP master DP slave Point-to-point coupling DP master Number of connections, max. Number of connections (of which reserved), max. Services PG/OP communication S7 basic communication S7 communication S7 communication, as client S7 communication, as server equidistance support Activation/deactivation of DP slaves direct data exchange (cross traffic) Transmission speeds, max. Number of DP slaves, max. Address area Inputs, max. Outputs, max. Useful data per DP slave Inputs, max. 16 1 for PG, 1 for OP Yes; Default setting No No 32 Yes No No No No No Yes No 12 Mbit/s 32; Number of slots, max. 512 2 KByte 2 KByte 244 Byte 244 Byte RS 485 / PROFIBUS Yes 32 Yes No No Yes 12 Mbit/s Yes; Default setting Yes No 32

RS 485 / PROFIBUS Yes

Yes No No No No No No No 12 Mbit/s 96 8 KByte 8 KByte 244 Byte

Price list version 01.10.2007 (Version 25.00)

Seite 6 von 7

CA 01

S7-400H - CPU 414H

Outputs, max. CPU/programming Programming language STEP 7 LAD FUP AWL SCL CFC GRAPH HiGraph User program protection/password protection Dimensions Width Height Depth Dimensions Required slots Weights Weight, approx.

244 Byte

Yes; V5.0 SP2 Yes Yes Yes Yes Yes Yes Yes Yes 50 mm 290 mm 219 mm 2 1,070 g

Price list version 01.10.2007 (Version 25.00)

Seite 7 von 7