Documenti di Didattica
Documenti di Professioni
Documenti di Cultura
171.6- 5.6
Code 78 / 88
H G K D
G D F
1)
1)
MALE Stecker
FEMALE Kuppler
1.6-5.6
Male | Stecker dimension [mm] A B C D E F G H I K 1) resilient, dimension to meet electrical and mechanical requirements 6.40 0.97 min. 1.60 nom. 5.60 nom. 4.00 0.15 1.03 5.50 6.60 0.25 6.60 8.10 6.70 9.70 M 9 x 0.5 2.90 3.10 max. Female | Kuppler min. 1.60 nom. 5.60 nom. 3.80 0.75 6.69 8.25 max.
Features
Interface according to CECC 22240 Frequency range DC to 4 GHz (II. Gen.), DC to 12 GHz (III. Gen.) Return loss (cable connector straight) 27 dB @ 1 GHz to 2 GHz Impedance 75 Type A: Screw-on coupling Type B: Snap-on coupling, available on request Type C: Slide-on coupling Type F: Quick-lock coupling
Product Range
Cable connectors PCB connectors (solder, press-fit versions) Panel connectors Adaptors, Balun-Adaptor Terminations Further connectors are available on request
166
Rosenberger Hochfrequenztechnik GmbH & Co. KG, POB 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com
1.6-5.6
Technology
Code 78 / 88
Applicable standards | Anwendbare Normen Interface according to | Interface gem Quality tested according to | Qualittsprfung gem Electrical data | Elektrische Daten Impedance | Wellenwiderstand Frequency range | Frequenzbereich Return loss (cable connector straight) | Rckflussdmpfung (Kabelsteckverbinder gerade) 75 DC to 4 GHz (II. generation) DC to 12 GHz (III. generation) 33 dB @ DC to 1 GHz 27 dB @ 1 GHz to 2 GHz 20 dB @ 2 GHz to 4 GHz 0.1 x f(GHz) dB 10 G 4 m 2 m 1000 V rms 330 V rms 90 dB @ DC to 1 GHz (Type C) 100 dB @ DC to 1 GHz (Type A) CECC 22240 IEC 60068
Insertion loss | Dmpfung Insulation resistance | Isolationswiderstand Center contact resistance | bergangswiderstand Innenleiter Outer contact resistance | bergangswiderstand Auenleiter Test voltage | Prfspannung Working voltage | Betriebsspannung RF-leakage | Schirmdmpfung Mechanical data | Mechanische Daten Mating cycles | Steckzyklen Center contact captivation | Innenleiter Haltekraft Engagement force | Steckkraft Disengagement force | Ziehkraft Coupling torque recommended | Drehmoment empfohlen Environmental data | Umweltdaten Temperature range | Temperaturbereich Dry heat | Trockene Wrme Damp heat | Feuchte Wrme Climatic category | Klimakategorie Vibration | Vibration Max. soldering temperature (PCB connectors) | Max. Lttemperatur (Leiterplattensteckverbinder) Materials | Materialien Spring loaded contact parts | Federnde Kontaktteile Center contact | Innenleiter Outer contact | Auenleiter Body | Gehuse Crimping ferrule | Crimphlse Dielectric | Dielektrikum Rosenberger-connectors fulfill in principle the indicated data of the Technical Data. Individual values of connectors may deviate depending upon application, design, type of cable, assembly method and execution. Specific data sheets for particular products can be provided on request from your Rosenberger sales partner.
500 axial: 30 N 2.2 N to 12 N (Type A, Type C) 18 N to 50 N (Type F) 2.2 N to 12 N (Type A, Type C) 18 N to 50 N (Type F) 30 N
1.6-5.6
-40 C to +85 C IEC 60068-2-2 IEC 60068-2-78 IEC 60068-2-1 40/85/21 IEC 60068-2-6 (10 Hz to 2000 Hz, 100 m/s) IEC 61760-1, +260 C for 10 sec.
CuBe, Au plating CuZn, Au plating CuZn, Au plating CuZn, Ni plating Soft copper, white bronze plating PTFE (II. generation) LCP or equivalent (III. generation) Rosenberger-Steckverbinder erfllen grundstzlich die in den Technischen Daten angegebenen Daten. Je nach Anwendung, Bauart, Kabeltyp, Montageart und -ausfhrung knnen einzelne Werte von Steckverbindern hiervon abweichen. Spezifische Datenbltter zu einzelnen Produkten erhalten Sie auf Anfrage von Ihrem Rosenberger-Ansprechpartner.
Rosenberger Hochfrequenztechnik GmbH & Co. KG, P.O. Box 1260, D-84526 Tittmoning, Tel. +49-86 84-18-0, Fax. +49-86 84-18-499, www.rosenberger.com
167