Documenti di Didattica
Documenti di Professioni
Documenti di Cultura
COGENERATION
PHOTOVOLTAICS
SERVICES
2 8
BLOCKHEIZKRAFTWERKE COGENERATION
PHOTOVOLTAIK PHOTOVOLTAICS
SERVICES
WRZ offers
Comprehensive advice on your CHP unit project The design of a CHP unit according to your requirement profile Engineering services, such as planning and project management A CHP unit in container or compact versions CHP units in different output categories CHP units which can be operated using natural gas, vegetable oil or heating oil Connection to your supply grid Support for the installation around the clock and 365 days a year
Take advantage of
Greater security of supply (power and heat) A positive image through active environmental protection by the use of renewable energies The benefits of being your own power generator Subsidies from the state (loans, cogeneration bonus, renewable energy bonus, etc.) Income through the sale of power and heat
Rittal in Herborn, Germany: CHP unit with a Wrz 36 m3 WE-CG-340-V fuel tank.
BLOCKHEIZKRAFTWERKE COGENERATION
PHOTOVOLTAIK PHOTOVOLTAICS
Service concepts
1. Remote control Remote control comprises remote monitoring and remote diagnosis for your CHP unit 365 days a year and around the clock. Maintenance and repair advice is provided where needed by our service staff.
2. Repair In addition to remote control our staff also carry out the major servicing of the equipment, including the exchange of worn and replacement parts.
3. Full repair In full repair all forms of regular maintenance and repair work (such as the changing of the engine oil) are carried out including the appropriate replacement parts. Additional parts will be replaced where needed and in line with the given maintenance intervals or after the given running time, even for items such as the engine. 4. Maintenance In addition to full repair, maintenance includes all replacement parts and repairs, even the replacement of the engine if necessary. If desired, the availability of the installation may be guaranteed in a performance contract for up to 7,500 operating hours annually, depending on the heat profile.
SERVICE SERVICES
77 kW 25 kW 44 kW 32.3% 56.9% 89.3% 400 V 37 A 50 Hz 1.0 *60 dB(A) 85 C/65 C 2.07 x 0.8 x 1.37 m RAL 6032 1,300 kg
141 kW 50 kW 78 kW 35.5% 55.3% 90.8% 400 V 74 A 50 Hz 1.0 *68 dB(A) 90 C/65 C 2.46 x 0.99 x 1.79 m RAL 6032 2,000 kg
247 kW 100 kW 105 kW 40.5% 42.4% 82.9% 400 V 144 A 50 Hz 1.0 62 dB(A) 90 C/70 C *7.5 x 2.5 x 2.6 m RAL 6011 8,000 kg
364 kW 150 kW 144 kW 41.2% 39.6% 80.8% 400 V 217 A 50 Hz 1.0 62 dB(A) 90 C/70 C *7.5 x 2.5 x 2.6 m RAL 6011 8,500 kg
477 kW 200 kW 208 kW 41.9% 43.6% 85.5% 400 V 289 A 50 Hz 1.0 62 dB(A) 90 C/70 C *7.5 x 2.5 x 2.6 m RAL 6011 8,500 kg
589 kW 250 kW 257 kW 42.4% 43.6% 86.0% 400 V 361 A 50 Hz 1.0 62 dB(A) 90 C/70 C *7.5 x 2.5 x 2.6 m RAL 6011 8,500 kg
774 kW 333 kW 336 kW 43.0% 43.4% 86.4% 400 V 481 A 50 Hz 1.0 62 dB(A) 90 C/70 C *7.5 x 2.5 x 2.6 m RAL 6011 9,500 kg
790 kW 340 kW 344 kW 43.0% 43.5% 86.5% 400 V 491 A 50 Hz 1.0 62 dB(A) 90 C/70 C *7.5 x 2.5 x 2.6 m RAL 6011 9,500 kg
Data based on a rated load at cos phi = 1 and normed conditions as per ISO 3046-1: 25 C ambient temperature, 100 kPa air pressure, 100 m above sea level, 30% relative humidity. The technical data and tolerances apply as given in each of the current data sheets prepared for each individual country. As part of our process of continuous development we retain the right to modify the technical data without advance notice. *1 Continuous mechanical performance ICXN (to ISO 3046-1, rapeseed oil fuel, not overloaded at cos = 1) *2 Rapeseed oil in line with the in-house fuel standards of WRZ Energy GmbH (minimum requirements DIN 51605). The use of additional fuels is possible on request. *3 Fuel consumption based on rapeseed oil with a fuel heating value Hu of 37,500 kJ/kg (10.417 kWh/kg) *4 Container dimensions plus roof mounting *5 Further RAL colours available on request Additional soundproofing measure possible
BLOCKHEIZKRAFTWERKE COGENERATION
PHOTOVOLTAIK PHOTOVOLTAICS
80 kW 25 kW 44 kW 31.2% 54.8% 86.0% 400 V 37 A 50 Hz 1.0 60 dB(A) 85 C/65 C 2.07 x 0.8 x 1.37 m RAL 6032 1,300 kg
139 kW 50 kW 67 kW 35.9% 48.1% 84.0% 400 V 74 A 50 Hz 1.0 70 dB(A) 85 C/70 C 2.5 x 1.04 x 1.6 m RAL 6032 2,000 kg
247 kW 100 kW 105 kW 40.5% 42.4% 82.9% 400 V 144 A 50 Hz 1.0 62 dB(A) 90 C/70 C *7.5 x 2.5 x 2.6 m RAL 6011 8,000 kg
364 kW 150 kW 144 kW 41.2% 39.6% 80.8% 400 V 217 A 50 Hz 1.0 62 dB(A) 90 C/70 C *7.5 x 2.5 x 2.6 m RAL 6011 8,500 kg
477 kW 200 kW 208 kW 41.9% 43.6% 85.5% 400 V 289 A 50 Hz 1.0 62 dB(A) 90 C/70 C *7.5 x 2.5 x 2.6 m RAL 6011 8,500 kg
589 kW 250 kW 257 kW 42.4% 43.6% 86.0% 400 V 361 A 50 Hz 1.0 62 dB(A) 90 C/70 C *7.5 x 2.5 x 2.6 m RAL 6011 8,500 kg
774 kW 333 kW 336 kW 43.0% 43.4% 86.4% 400 V 481 A 50 Hz 1.0 62 dB(A) 90 C/70 C *7.5 x 2.5 x 2.6 m RAL 6011 9,500 kg
790 kW 340 kW 344 kW 43.0% 43.5% 86.5% 400 V 491 A 50 Hz 1.0 62 dB(A) 90 C/70 C *7.5 x 2.5 x 2.6 m RAL 6011 9,500 kg
Data based on a relate to a rated load at cos phi = 1 and normed conditions as per ISO 3046-1: 25 C ambient temperature, 100 kPa air pressure, 100 m above sea level, 30% relative humidity. The technical data and tolerances apply as given in each of the current data sheets prepared for each individual country. As part of our process of continuous development we retain the right to modify the technical data without advance notice. *1 Continuous mechanical performance ICXN (to ISO 3046-1, diesel fuel, not overloaded at cos = 1) *2 Heating oil. The use of additional fuels is possible on request. *3 Fuel consumption based on heating oil with a heating value of a minimum of 42,500 kJ/kg *4 Container dimensions plus roof mounting *5 Further RAL colours available on request Additional soundproofing measure possible
SERVICE SERVICES
Asynchronised Parallel to mains supply Natural gas. liquid gas 3.40 kWh/kWh
Asynchronised Parallel to mains supply Natural gas. liquid gas 3.53 kWh/kWh
282 kW 104 kW 138 kW 36.9% 48.9% 85.8% 400 V 144.0 A 50 Hz 1.0 75 dB(A)
Data based on a rated load at cos phi = 1 and normed conditions as per ISO 3046-1: 25 C ambient temperature, 100 kPa air pressure, 100 m above sea level, 30% relative humidity. The technical data and tolerances apply as given in each of the current data sheets prepared for each individual country. As part of our process of continuous development we retain the right to modify the technical data without advance notice. *1 Continuous mechanical performance ICXN (to ISO 3046-1, not overloaded at cos = 1) *2 Natural gas. The use of additional fuels is possible on request. *3 Dimensions = smallest possible design as a complete module. A modular form in a heating cellar is possible. *4 Further RAL colours available on request Additional soundproofing measures possible
BLOCKHEIZKRAFTWERKE COGENERATION
PHOTOVOLTAIK PHOTOVOLTAICS
392 kW 142 kW 207 kW 36.2% 52.8% 89.0% 400 V 205.0 A 50 Hz 1.0 75 dB(A)
553 kW 200 kW 293 kW 36.2% 53.0% 89.2% 400 V 289.0 A 50 Hz 1.0 94 dB(A)*
669 kW 240 kW 365 kW 35.9% 54.6% 90.4% 400 V 347.0 A 50 Hz 1.0 90 dB(A)*
1,045 kW 404 kW 513 kW 38.7% 49.1% 87.8% 400 V 583.0 A 50 Hz 1.0 94 dB(A)*
Data based on a rated load at cos phi = 1 and normed conditions as per ISO 3046-1: 25 C ambient temperature, 100 kPa air pressure, 100 m above sea level, 30% relative humidity. The technical data and tolerances apply as given in each of the current data sheets prepared for each individual country. As part of our process of continuous development we retain the right to modify the technical data without advance notice. *1 Continuous mechanical performance ICXN (to ISO 3046-1, not overloaded at cos = 1) *2 Natural gas. The use of additional fuels is possible on request. *3 Dimensions = smallest possible design as a complete module. It may be transported into a heating cellar in a knocked-down form. *4 Further RAL colours available on request Additional soundproofing measures possible
SERVICE SERVICES
References
90 kW vegetable-oil-powered CHP unit in a container with 25 m main tank and buffer tank
120 kW vegetable-oil-powered CHP unit in a container with 2 x 24 m vegetable oil tank, heating oil tank with 24 m main heating oil tank and 24 m buffer tank
340 kW CHP unit in a container with 220 kW absorption cooler, 50 m vegetable oil tank und two 60 m buffer tanks for heat and cooling energy
BLOCKHEIZKRAFTWERKE COGENERATION
PHOTOVOLTAIK PHOTOVOLTAICS
10
340 kW vegetable-oil-powered CHP unit in a container with 50 m main vegetable oil tank and 50 m buffer tank
2 x 8 kW vegetable-oil-powered CHP unit with 10 kW absorption cooler, 750 litre fuel tank and 1,100 litre cold storage tank in a container
150 kW vegetable-oil-powered CHP unit in a container with 35 m main tank and 26 m buffer tank
SERVICE SERVICES
11