RE 92 703/12.

99

RE 92 703/12.99
Replaces: 04.96

Variable displacement pump A10VO


open-loop circuit, axial piston swashplate design

Size 28 - 85 Series 52 Nominal pressure 250 bar Peak pressure 315 bar
A10VO

Contents
Features Ordering code / standard range Fluid Technical data Installation Notes Unit dimensions size 28, portplate 11, 61, 64 Unit dimensions size 28, portplate 12, 62 Unit dimensions size 45, portplate 11, 61 Unit dimensions size 45, portplate 64 Unit dimensions size 45, portplate 12, 62 Unit dimensions size 60, portplate 12, 62 Unit dimensions size 60, portplate 11, 61 Unit dimensions size 85, portplate 11 Unit dimensions size 85, portplate 12, 62 Pressure control DR Pressure-remote control DRG Pressure/flow control DFR/DFR1 Through drive Unit dimensions combination pump, K01, K52 Unit dimensions K02, K68 Unit dimensions K04, K15 Unit dimensions K24 and preferred types 1 2, 3 4 5, 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24

Features
Variable-displacement axial piston pump in swashplate design for hydrostatic drives in open circuits Flow is proportional to drive speed and displacement. It can be infinitely varied by adjustment of the swashplate. Strong bearings for long life High permissible drive speed High power-weight ratio - small dimensions Low noise level Good suction characteristics Permissible continous pressure 250 bar Axial and radial loading of drive shaft possible Pressure and flow control Electro-hydraulic pressure control Short response times 2 drain ports

A10VO

1 /24

RE 92 703/12.99

Ordering code

Fluid Mineral oil (no short code) Axial piston unit Swashplate design, variable Nominal pressure 250 bar, peak pressure 315 bar Operating mode Pump, open-loop circuit Size Displacement Vg max (cm3 ) Control devices Pressure control Pressure-remote control Pressure- and flow control without orifice between X and tank Electro-hydraulic pressure control Series
52

A10V

28 G

45 G

60 G

85 G

DR DRG DFR DFR ED

G G G G G

G G G G G

G G G G G

G G G G H

DR DRG DFR DFR1 ED


see RE 92707
(in preparation)

Direction of rotation Viewed on shaft end

clockwise anticlockwise

R L

Seals NBR (Nitrile rubber to DIN ISO 1629) FKM (Fluoride rubber to DIN ISO 1629) Shaft end Splined shaft SAE Splined shaft SAE (higher through drive torque) Splined shaft SAE (not suitable for through drive) Splined shaft SAE (with run out spline) SAE key 28 7/8" 7/8" 7/8" 45 1" 1" 7/8" 7/8" 1" 60 1 1/4" H 1" 1" 1 1/4" 85 1 1/2" H 1 1/4" H H

P V

S R U W K

= Preferred range (short delivery times) (Preferred types see page 24)

Brueninghaus Hydromatik

2/24

A10VO

RE 92 703/12.99

Ordering code

A10V O

/ 52

Mounting flange SAE - 2 hole SAE - 4 hole Connection for service lines Pressure port B Suction port S Pressure port B Suction port S Pressure port B Suction port S Pressure port B Suction port S Pressure port B Suction port S

28 G 28
G G G G G

45 G 45
G G G G G

60 G G 60
G G G G

85 G H 85
H G G G

C D

Threaded, UN rear SAE- flange rear - UNC threads SAE- flange rear - metric threads SAE- flange side ports UNC threads SAE- flange side ports metric threads

64 61 11 62 12

only possible without through drive

Through drive without through drive Mounting flange shaft-coupler 82-2 (SAE A) 16-4 (SAE A) 82-2 (SAE A) 19-4 (SAE A-B) 101-2 (SAE B) 22-4 (SAE B) 101-2 (SAE B) 22-4 (SAE B) 101-2 (SAE B) 25-4 (SAE B-B) 127-4 (SAE C) 32-4 (SAE C) 127-2 (SAE C) 38-4 (SAE C-C) G = available

28 G to mount: 1PF2G2; PGF2 A10VSO 10, 18 (shaft S) 1PF2G3 A10VO 28 (shaft S); PGF3 A10VO 45 (shaft S); PGH4 A10VO 60 (shaft S) A10VO 85 (shaft S); PGH5 = not available G H H G

45 G G G G G G

60 G G G H G G G

85 G H H H H H H G

N00 K01 K52 K02 K68 K04 K15 K24

H = in preparation

A10VO

3 /24

Brueninghaus Hydromatik

RE 92 703/12.99

Hydraulic fluid
We request that before starting a project, detailed information about the choice of hydraulic fluids and application conditions are taken from our catalogue sheets RE 90220 (mineral oil), RE 90221 (environmentally acceptable hydraulic fluids). When using environmentally acceptable hydraulic fluids possible limitations for the technical data may apply. If necessary please contact our technical department (please indicate type of the hydraulic fluid used in your application when ordering). Operating viscosity range We recommend that the operating viscosity (at operating temperature), for both the efficiency and life of the unit, be chosen within the optimum range of: opt = opt. operating viscosity 16...36 mm2/s referred to tank temperature at open circuit. Viscosity limits The limiting values for viscosity are as follows: min = 5 mm2/s short term, at a max. permissible leakage oil temperature tmax = 115C. Please note that the max. fluid temperature of 115C is also not exceeded in certain areas (for instance bearing area). max = 1600 mm2/s short term, on cold start (tmin = -40C). At temperatures of -25 C up to -40C special measures may be required for certain installation positions. Please contact us for further information. At temperatures of +90C to 115C please use FKM seals (type code character V). Notes on the selection of hydraulic fluid In order to select the correct fluid, it is necessary to know the operating temperature in the tank (open circuit) in relation to the ambient temperature. The hydraulic fluid should be selected so that within the operating temperature range, the operating viscosity lies within the optimum range ( opt; see shaded section of the selection diagram). We recommend that the higher viscosity grade is selected in each case. Example: at an ambient temperature of X C, the operating temperature in the tank is 60C. In the optimum viscosity range opt. (shaded area), this corresponds to viscosity grades VG 46 or VG 68, VG 68 should be selected. Important: The leakage oil temperature is influenced by pressure and speed and is typically higher than the tank temperature. However, maximum temperature at any point in the system may not exceed 115C. At high temperatures please use FKM seals. Please consult Brueninghaus Hydromatik if the a.m. conditions cannot be kept at extreme operation parameters or because of high ambient temperature. Filtration of fluid The finer the filtration, the better the achieved cleanliness of the pressure fluid and the longer the life of the axial piston unit. To ensure the functioning of the axial piston unit, a minimum cleanliness of: 9 to NAS 1638 18/15 to ISO/DIS 4406 is necessary. If above mentioned grades cannot be maintained please consult us.

Selection diagram

2500-40 1600 1000 600 400 200 100


Viscosity in mm2/s

-20

20

40

60

80 100

1600

0 10 G V 68 G V 46 G V 32

V G

22

60 40 20 10

36 opt. 16

5 -40

-25

-10 0 10 30 50 Fluid temperature range

70

5 90 115 Temperature t in C tmax = +115C

tmin = -40C

Brueninghaus Hydromatik

4/24

A10VO

RE 92 703/12.99

Technical data
Input operating pressure range Absolute pressure at port S (suction port) pabs min _____________________________________________________ 0.8 bar pabs max _____________________________________________________ 30 bar Output operating pressure range Pressure at port B Nominal pressure pN ______________________________________ 250 bar Peak pressure pmax ________________________________________ 315 bar (Pressure data to DIN 24312) Direction of flow S to B. Case drain pressure The maximum permissible pressure of the leakage fluid (at port L, L1): max. 0.5 bar higher than input pressure at port S, but not higher than 2 bar absolute. pL abs max ______________________________________________________ 2 bar Determination of input pressure pabs at suction port S or reduction of displacement with increasing speed.
1,2
1,6

1,4

1,1
1,2

1,0

1,0

0,9 0,8

0,9

0,7

0,8

0,9

1,0

Displacement Vg/Vgmax

Table of values (theoretical values, without considering mh and v; approximate values) Size Displacement Max. speed1) Max. flow Max. power ( p = 250 bar) Max. torque (p = 250 bar) Moment of inertia about the drive axis Fill volume Mass (without fluid) Permissible loading of drive shaft: Max. permissible axial force Max. permissible radial force
1

28 at Vg max at no max at nE = 1500 rpm at no max at nE = 1500 rpm at Vg max Vg max no max qv o max Po max Tmax J m Fax max Fq max cm rpm L/min L/min kW kW Nm kgm2 L kg N N Forces + Fax - Fax
3

45 45 2600 2) 117 68 49 28 179 0.0033 0.5 18 1500 1500 Fq

60 60 2700 162 90 68 38 238 0.0056 0.8 22 2000 1700

85 87 2500 217 130 90 54 345 0.012 1 34 3000 2000

28 3000 84 42 35 18 111 0.0017 0.3 14 1000 1200

) The values are quoted for an absolute pressure of 1 bar at suction port S. If the displacement is reduced or the input pressure is increased, the speed can be increased as shown in the graph. 2 ) Higher speeds available on request.

X/2 X/2 X Determination of size Flow Drive torque qv = T = Vg n v 1000 1.59 Vg p 100 mh [L/min] [Nm] V g = Geometric displacement [cm3] per revolution p = Differential pressure [bar] n = Speed [rpm] v = Volumetric efficiency mh = Mechanical-hydraulic efficiency t = Total efficiency (t = v mh)

Drive power

P =

2 T n T n qv p = = [kW] 60000 9549 600 t

A10VO

5 /24

Brueninghaus Hydromatik

Input pressure pabs [bar]

Speed n/nmax

RE 92 703/12.99

Operating curves for pump with pressure control DR


Noise level Measured in an anechoic chamber to DIN 43635 Distance from microphone to pump = 1 m Measuring error to DIN 45635, part 1: 2 dB (A) (Fluid: hydraulic oil to ISO VG 46 DIN 51519, t = 50C) Size 28
77 75 q v max q v min
-1 n= =3000 3000min rpm n -1 rpm

Drive power and flow (fluid: mineral oil to ISO VG 46 DIN 51519, t = 50 C)

Size 28 n = 1500 rpm n = 3000 rpm


90 80 60 40 20 0 50 100 150 Pqv min 200 250 qv Pqv max

Noise level L Schalldruckpegel LA [dB(A)] A [dB(A)]

73 71 69 67 65 63 61 59 0 50 100 150 200


n= =1500 1500min n

q v max

Volumenstrom [L/min] Flow q qv [L/min] V

30 20 10 0

Operating pressurep p [bar] [bar] Betriebsdruck

250

Betriebsdruck pp [bar] Operating pressure [bar]

Size 45
80 q v max q v min
-1 n = 2600 2600min rpm n=

Schalldruckpegel [dB(A)] Noise level L L [dB(A)] A A

78 76 74

Size 45 n = 1500 rpm n = 2600 rpm


120 60
Drive powerPP [kW] Antriebsleistung [kW] qv qv Drive power P P [kW] Antriebsleistung qv qv

70 68 66 64 62 60 0 50 100 150 200


-1 n = 1500 1500min rpm n=

q v min

Volumenstrom Flow qV v [L/min]

72

q v max

100 80 60 40 20 0 50

qv Pqv max

50 40 30 20 Pqv min 10 0 100 150 200 250

250

Betriebsdruck pp [bar] Operating pressure [bar]


Size 60 n = 1500 rpm n = 2700 rpm
160
Flow qv Volumenstrom [L/min] V
q v max q v min

Betriebsdruck pp [bar] Operating pressure [bar]

Size 60
82 q v max q v min
-1 n rpm n = 2700 2700 min

Noise level LL [dB(A)] Schalldruckpegel [dB(A)] AA

80 78 76 74 72 70 68 66 64 62 60 0 50 100 150 200


-1 n 1500min rpm n = 1500

80 70 qv Pqv max 60 50 40 30 Pqv min 20 10 0 50 100 150 200 250

140 120 100 80 60 40 20 0

250

Operating pressure [bar] Betriebsdruck pp [bar]

Betriebsdruck pp [bar] Operating pressure [bar]

Data for size 85 available on request. Brueninghaus Hydromatik 6/24 A10VO

Drive power P Pqv [kW] Antriebsleistung qv

q v min

40

RE 92 703/12.99

Installation Notes
Installation position is optional. The pump housing must be filled with fluid during commissioning and remain full when operating. In order to achieve the lowest noise value, all connections (suction, pressure, case drain ports) must be linked by flexible couplings to the reservoir. Avoid placing a check valve in the case drain line. This may, however, be permissible in individual cases, after consultation with us. 1. Vertical installation (shaft end upwards) Please contact us. The following installation conditions must be taken into account: 1.1. Arrangement in the reservoir Before installation fill pump housing, keeping it in a horizontal position. a) If the minimum fluid level is equal to or above the pump mounting face leave ports L, "L1" and S open (see Fig.1). b) If the minimum fluid level is below the pump mounting face pipe port L 1, and possibly S according to Fig. 2. Close port "L" with respect taking into consideration conditions in 1.2.1. 2. Horizontal installation The pump must be installed, so that "L" or "L1" is at the top. 2.1. Installation within the reservoir a) If the minimum fluid level is equal to or above the top of the pump, ports "L", "L1" and S should remain open (see Fig. 3) b) If the minimum fluid level is below the top of the pump, pipe ports "L", "L1" and possibly "S" as Fig. 4. The conditions correspond to item 1.2.1.

L1 L

Fluid Fluid

Fluid Fluid

S
2.2. Installation outside the reservoir Fill the pump housing before commissioning. Pipe ports "S" and the higher port "L" or "L1". a) When mounting above the reservoir, see Fig. 4. Conditions correspond to 1.2.1.
L L1

p EIn min

Fig. 3

L1 L S
Fig. 1 1.2. Installation outside the reservoir Before installing the pump, fill the pump with housing in the horizontal position. For mounting above reservoir see Fig. 2. Limiting conditions: 1.2.1. Minimum pump inlet pressure pin min = 0.8 bar both static and dynamic conditions. Note: Avoid mounting above reservoir wherever possible in order to achieve a low noise level. The permissible suction height h comes from the overall pressure loss, but may not be bigger than hmax = 800 mm (immersion depth hd min = 200 mm).

Fluid

Baffle

S
h t min h max

p EIn min

L1

h max

Fig. 4 b) Mounting below the reservoir Pipe ports "L" and S according to Fig.5.
Fluid

Fluid Fluid

Baffle

Fig. 2 Baffle
L = density (kg/m3) L1 p EIn min

Overall pressure loss ptot = p1 + p2 + p3 (1 pin min) = 0.2 bar p1: Pressure loss in pipe due to accelerating column of fluid p1 =
l

dv

dt

105 (bar)

l = pipe lenght (m) dv/dt = rate of change in fluid velocity (m/s2) p2: Pressure loss due to static head p2 = h g 105 (bar) h = head (m) = density (kg/m3) g = gravity. = 9.81 m/s2 p3: Line losses (elbows etc.) A10VO 7 /24

Fig. 5

Brueninghaus Hydromatik

RE 92 703/12.99

Unit dimensions, size 28


DR DFR 61 DFR1 /52 R -X S C 64 N00 DRG 11
140 90

Prior to finalising your design, please request certified installation drawing. All rights reserved subject to revision.

Version A10VO 28

X
45
3/ 16 4123.5

9.5 6.3

12

Flange 101-2 Flansch 101-2 SAE J744 OCT 83

UN B F-2

L
101.6h8 7/8 1/4-20UNC-2B

107

W
16
73 66

25.1
7.9 41

27

L1

170 205

146 172

Shaft S 22-4; SAE J744 OCT 83 Welle 7/8 Keilwellengre; Eingriffswinkel 7/8"splined shaft size;30 30 pressure angle 13 16/32 DP Pitch-Tlg. 13 Zhne; teeth; 16/32 View WW Ansicht port plate 64 64 Anschluplatte shown is clockwise Drehrichtung rechts rotation
63 11.5

X
7/16-20UNF-2B 107

View WW Ansicht port plate 61/11 Anschluplatte 61 / 11 shown is clockwise Drehrichtung rechts rotation

63

11.5

X
7/16-20UNF-2B 107

58.7 32

20 20 tief deep

S 1 5/8-12UN-2B
33 33

20 tief deep 20

B 1 1/16-12UN-2B

S SAE SAE 1 1 1/4 1/4" S standard pressure Standarddruckreihe range bei Platte11 11 w. plate M 10; 17 deep tief M10; 30.2 w. plate bei Platte61 61 33 7/16-14UNC-2B; 7/16-14 UNC-2B, 24 tief 24 deep

B SAE 3/4 standard pressure range Standarddruckreihe


22.2 33 beiplate Platte 11 w. 11 M 10;17 17 deep tief M10; w. plate bei Platte61 61 3/8-16UNC-2B; 3/8-16 UNC-2B, 19 tief 19 deep

R and K shaft, see page 9. For ccw - rotation, turn port plate 180 Connections Port Plate 64 B Pressure port 1 1/16-12UN-2B S Inlet port 1 5/8-12UN-2B 3/4-16UNF-2B L/L1 Case drain X Pilot port 7/16-20UNF-2B with control DR, pilot port X is plugged For ccw - rotation, turn port plate 180 Connections Port plates 61 and 11 B Pressure port SAE 3/4" (Standard pressure range) S Inlet port SAE 1 1/4" (Standard pressure range) L/L1 Case drain 3/4-16UNF-2B X Pilot port 7/16-20UNF-2B with control DR, pilot port X is plugged

Brueninghaus Hydromatik

8/24

20 47.6

A10VO

14.3

69

RE 92 703/12.99

Unit dimensions, size 28


Prior to finalising your design, please request certified installation drawing. All rights reserved subject to revision.

Version A10VO 28

DFR DFR1 /52 R -X S C 62 N00 DRG 12


204.5 139.5 90

12 9.5 6.3 Flansch 101-2 Flange 101-2 SAE J744 OCT 83

X
45
43/ 16 UN F-2

123.5

L
101.6h8 7/8 1/4-20UNC-2B

16

32 58.7

W
73 66

S SAE 1 1/4
25.1
7.9 41

27

L1
160

30.2

bei plate Platte 12 w. 12 M10; 17 tief deep bei plate Platte 62 w. 62 7/16-14UNC-2B; 24 tief 24 deep

146 172

Welle Shaft S 22-4; SAE J744 OCT 83

7/8 Keilwellengre; 30 Eingriffswinkel 7/8"splined shaft size; 30 pressure angle 13 16/32 DP Pitch-Tlg. 13 Zhne; teeth; 16/32

View W W Ansicht shown is clockwise Drehrichtung rechts rotation Ansicht View V V Drehrichtung rechts shown is clockwise rotation

63 11.5

Welle Shaft K K

2.5
22.225-0,02 1/4-20UNC-2B

28.6

6.35 +0,025
25 -0,15

7/16-20UNF-2B 107

47.6 20

16

B SAE 3/4
8 41.3

w. plate bei Platte12 12 17 tief deep M10; 17 22.2 bei Platte62 62 w. plate 3/8-16UNC-2B;19 3/8-16UNC-2B; 19tief deep

66

66

Welle Shaft R 22-4; SAE J744 OCT 83

7/8 Keilwellengre; 30 Eingriffswinkel 7/8"splined shaft size; 30 pressure angle 13 16/32 DP Pitch-Tlg. 13 Zhne; teeth; 16/32

7/8 1/4-20UNC-2B

16

For ccw - rotation, turn port plate 180 Connections Port plates 12 and 62 B Pressure port 3/4" (Standard pressure range) S Inlet port SAE 1 1/4" (Standard pressure range) 3/4-16UNF-2B L/L1 Case drain X Pilot port 7/16-20UNF-2B
32

25 41

A10VO

9 /24

Brueninghaus Hydromatik

14.3

68

.5

RE 92 703/12.99

Unit dimensions, size 45


Pressure control DR Version A10VO 45 DR /52 R-X S C 11 N00 61
Prior to finalising your design, please request certified installation drawing. All rights reserved subject to revision.

9.5 6.3

99 12 30 7/8-14UNF-2B

45

87/

131.5

Flange 101-2 Flansch 101-2 SAE J744 OCT 83

L1 L

14 UN F-2 B

101.6h8 1 1/4-20UNC-2B

77

W
16

30
7.9 45.9

189 215.5

68.5

146 172

Welle Shaft S 25-4; SAE J744 OCT 83

1 Keilwellengre; Eingriffswinkel 1"splined shaft size;30 30 pressure angle 15 16/32 DP Pitch-Tlg. 15 Zhne; teeth; 16/32

Welle Shaft R 25-4; (SAE B-B) SAE J744 OCT 83


1 Keilwellengre; Eingriffswinkel 1"splined shaft size;30 30 pressure angle 15 16/32 DP Pitch-Tlg. 15 Zhne; teeth; 16/32

View W W Ansicht Anschluplatte 11/61 port plate 11/61 Drehrichtung rechts shown is clockwise rotation

1 1/4-20UNC-2B

69.

16 29.5 45.9

w. plate 11 bei Platte 11 deep M12; 20 tief bei Platte61 61 w. plate 1/2-13UNC-2B; 22 tief deep

38

35.

7
30

26.
38

2
30 38

Welle Shaft U 22-4; (SAE B) SAE J744 OCT 83


7/8 Keilwellengre; Eingriffswinkel 7/8"splined shaft size;30 30 pressure angle 13 16/32 DP Pitch-Tlg. 13 Zhne; teeth; 16/32

beiplate Platte 11 w. 11 tief M10; 17 deep beiplate Platte 61 w. 61 3/8-16UNC-2B; 3/8-16UNC-2B; 18 deep tief 18

For ccw - rotation, turn port plate 180


7/8 1/4-20UNC-2B

W shaft see page 11, K shaft see page 12.


16 25 7.9 41

Ports B Pressure port S Inlet port L/L1 Case drain 10/24

SAE 1" (Standard pressure range) SAE 1 1/2" (Standard pressure range) 7/8-14UNF-2B

Brueninghaus Hydromatik

52. 4

A10VO

25

78

14.3

32

RE 92 703/12.99

Unit dimensions, size 45


Version A10VO 45 DRG DFR /52 R-X S C 64 N00 DFR1
150.5 99 9.5 6.3 30 12 7/8-14UNF-2B Prior to finalising your design, please request certified installation drawing. All rights reserved subject to revision.

X
45

L1
131.5 Flange 101-2 Flansch 101-2 SAE J744 OCT 83

87/ 14 UN F-2 B

L
101.6h8 1 1/4-20UNC-2B

W
16

14.3 11.5

78

30 7.9 45.9

189 215.5

146 172

Shaft S 25-4; SAE J744 OCT 83 Welle 1 1"splined Keilwellengre; shaft size; 30 30 Eingriffswinkel pressure angle 15 16/32 DP Pitch-Tlg. 15 Zhne; teeth; 16/32 View WW Ansicht port plate 64 64 Anschluplatte shown is clockwise Drehrichtung rechts rotation Shaft R 25-4; (SAE B-B) SAE J744 OCT 83 Welle 1 Keilwellengre; 30 Eingriffswinkel 1"splined shaft size; 30 pressure angle 15 16/32 DP Pitch-Tlg. 15 Zhne; teeth; 16/32
1 1/4-20UNC-2B

68

X
7/16-20UNF-2B

16

29,5 45.9

S 1 7/8-12UN-2B 20 deep tief


38 38

B 1 5/16-12UN-2B 20 deep tief 20

Shaft Welle W 22-4; (SAE B) SAE J744 OCT 83


7/8 7/8"splined Keilwellengre; shaft size;30 30 Eingriffswinkel pressure angle 13 Zhne; 16/32DP Pitch-Tlg. teeth; 16/32

For ccw - rotation, turn port plate 180

7/8 1/4-20UNC-2B

32

U shaft see page 10, K shaft see page 12. Ports B S L/L1 X

16 25

41

Pressure port Inlet port Case drain Pilot port

1 5/16-12UN-2B 1 7/8-12UN-2B 7/8-14UNF-2B 7/16-20UNF-2B

A10VO

11/24

Brueninghaus Hydromatik

115

68.5
32

77

RE 92 703/12.99

Unit dimensions, size 45


DRG DFR /52 R-X U C 12 N00 DFR1 62
215.5 150.5 9.5 6.3 99 12 30 7/8-14UNF-2B Prior to finalising your design, please request certified installation drawing. All rights reserved subject to revision.

Version A10VO 45

X
45

L1
Flange 101-2 Flansch 101-2 SAE J744 OCT 83 131.5

87/ 14 UN

S SAE 1 1/2 L

F-2

standard pressure Standarddruckreihe range

101.6h8 7/8 1/4-20UNC-2B

25 7.9 41

35.7 178 211

bei Platte12 12 w. plate M12; M12; 20 20 tief deep bei Platte62 62 w. plate 1/2-13UNC-2B 1/2-13UNC-2B

146 172 68 11.5

Welle Shaft U 22-4; SAE J744 OCT 83

7/8 Keilwellengre; 30 Eingriffswinkel 7/8"splined shaft size; 30 pressure angle 13 Pitch-Tlg. 13Zhne; teeth; 16/32 DP

Ansicht View WW Anschluplatte 12/62 port plate 12/62 Drehrichtung rechts shown is clockwise rotation Ansicht View V V Drehrichtung shown is clockwise rechts rotation

X
7/16-20UNF-2B 115

Welle Shaft R 25-4; (SAE B-B) SAE J744 OCT 83 1 Keilwellengre; 30 Eingriffswinkel 1"splined shaft size; 30 pressure angle 15 Pitch-Tlg. 15Zhne; teeth; 16/32 DP
1 1/4-20UNC-2B

B SAE 1 standard pressure range Standarddruckreihe


w. plate bei Platte12 12N00 N00 M10; M 10; 17 17 deep tief bei Platte62 62N00 N00 w. plate 3/8-16UNC-2B 3/8-16UNC-2B

16

29.5 45.9

52.4 25

26.2

90

90

Shaft K Welle For ccw - rotation, turn port plate 180


2.2 25.4 -0.03 1/4-20UNC-2B 34.9 6.35 +0.025 28.2 -0.2

S und W shaft, see page 11. Ports B S L/L1 X 12/24

16

7.9 46

Pressure port Inlet port Case drain Pilot port

SAE 1" (Standard pressure range) SAE 1 1/2" (Standard pressure range) 7/8-14UNF-2B 7/16-20UNF-2B A10VO

Brueninghaus Hydromatik

68.5
32

16

38 69.9

14.3

78

77

RE 92 703/12.99

Unit dimensions, size 60


DR DRG DFR /52 R-X W C 12 N00 DFR1 62
150.5 117 9.5 6 40 15 7/8-14UNF-2B L1

Prior to finalising your design, please request certified installation drawing. All rights reserved subject to revision.

Version A10VO 60

X
45

137

Flange 101-2 Flansch 101-2 SAE J744 OCT 83

14 87/

L
101.6h8 1 1/4-20UNC-2B
32

S SAE 2 standard pressure range Standarddruckreihe

16 29

50 77.8

78

14.3

.5

7.9 45.9

201.5 239.5

42.9

w. plate bei Platte12 12 M12; 20 20 tief deep M12; bei Platte62 62 w. plate 1/2-13UNC-2B; 1/2-13UNC-2B; 22 tief 22 deep

146 172

Shaft W 32-4; SAE J744 OCT 83 Welle 1 Keilwellengre; 30 Eingriffswinkel 1"splined shaft size; 30 pressure angle 15 Zhne; 16/32 DP Pitch-Tlg. teeth; 16/32

View Ansicht WW port plate 12/62 Anschluplatte 12/62 Drehrichtung shown is rechts clockwise rotation View V V Ansicht shown is clockwise Drehrichtung rechts rotation

65

11.5

X
7/16-20UNF-2B 120.5

Welle Shaft U U25-4; (SAE B-B) SAE J744 OCT 83 Welle K 1 Keilwellengre; 3030 Eingriffswinkel 1"splined shaft size; pressure angle Shaft K16/32 15 15Zhne; teeth; 16/32Pitch-Tlg. DP
3
1 31.75-0,03 5/16-18UNC-2B 1/4-20UNC-2B

41.3

7.94 +0,025

35.3 -0,2

52.4 25

19

16 30 7.9 55.4 7.9 45.9

B SAE 1 standard pressure range Standarddruckreihe beiplate Platte12 12 w. M10; 17 tief deep bei plate Platte 62 w. 62 3/8-16UNC-2B; 18 tief 3/8-16UNC-2B; 18 deep

26.2

72

72

For ccw - rotation, turn port plate 180

S, K shaft and 4 hole mounting flange, see page 14. Ports B Pressure port SAE 1" (Standard pressure range) S Inlet port SAE 2" (Standard pressure range) 7/8-14UNF-2B L/L1 Case drain X Pilot port 7/16-20UNF-2B with control DR, pilot port X is plugged

A10VO

13/24

Brueninghaus Hydromatik

76

87

B F-2 UN

RE 92 703/12.99

Unit dimensions, size 60


DR DRG DFR /52 R-X S D 61 N00 DFR1 11
150.5 117 12.7 6 Flange 127-4 Flansch 127-4 SAE J744 OCT 83 15 7/8-14UNF-2B 40
45
87/

Prior to finalising your design, please request certified installation drawing. All rights reserved subject to revision.

Version A10VO 60

215.5

L1 L
137

127h8 11/4 5/16-18UNC-2B

19 39.5
76

7.9 55.4 208

114.5 146 65

Welle Shaft S 32-4; SAE J744 OCT 83

1 Keilwellengre; 30 Eingriffswinkel 1 1/4 1/4"splined shaft size; 30 pressure angle 14 12/24 DP Pitch-Tlg. 14 Zhne; teeth; 12/24

View WW Ansicht port plate 11/61 Anschluplatte 11/61 shown is clockwise Drehrichtung rechts rotation

11.5

X
7/16-20UNF-2B 120.5

Welle U 25-4; (SAE B-B) SAE J744 OCT 83 Shaft K Welle


31.75-0,03 1 5/16-18UNC-2B 1/4-20UNC-2B
1 Keilwellengre; 30 Eingriffswinkel 1"splined shaft size; 30 pressure angle 15 Pitch-Tlg. 15Zhne; teeth; 16/32 DP

41.3

7.94 +0,025

35.3 -0,2

19

16 30
7.9 55.4 7.9 45.9

77.8 50

standard pressure range Standarddruckreihe bei Platte11 11 w. plate M12; M12; 20 20 tief deep bei Platte61 61 w. plate 1/2-13UNC-2B; 22 tief 1/2-13UNC-2B; 22 deep 42.9 33 46 26.2

S SAE 2

bei 11 w. Platte plate 11 M10; M10;17 17tief deep bei 61 w. Platte plate 61 3/8-16UNC-2B; 18 tief 3/8-16UNC-2B; 18 deep

For ccw - rotation, turn port plate 180

W, U shaft and 2 hole mounting flange, see page 13. Ports B Pressure port SAE 1" (Standard pressure range) S Inlet port SAE 2" (Standard pressure range) 7/8-14UNF-2B L/L1 Case drain X Pilot port 7/16-20UNF-2B with control DR, pilot port X is plugged

Brueninghaus Hydromatik

14/24

25 52.4

B SAE 1 Standarddruckreihe standard pressure range

A10VO

114.5

148

78

.5

87

14 B F-2 3 UN 14.

RE 92 703/12.99

Unit dimensions, size 85


DR DRG DFR /52 R -X S C 11 N00 DFR1
171.5 130 12.7 40 20 1 1/16-12UN-2B

Prior to finalising your design, please request certified installation drawing. All rights reserved subject to revision.

Version A10VO 85

X
45

Flange Flansch127-2 127-2 SAE J744 JUL 88

L1
155.5

1 N 2U -1 16 1/ B -2

127h8 11/2 7/16-14UNC-2B

W
28 43.5

96

17.5 7.9 61.9 245 158 181 210 74 7/16-20UNF-2B

Shaft S 38-4; SAE J744 JUL 88 Welle 1 Keilwellengre; 30 Eingriffswinkel 1 1/2 1/2"splined shaft size; 30 pressure angle 17 12/24 DP Pitch-Tlg. 17 Zhne; teeth; 12/24

View WW Ansicht port plate 11 11 Anschluplatte shown is clockwise Drehrichtung rechts rotation

11.5

88.9 60

S SAE 2 1/2

standard pressure Standarddruckreihe range M12; 1717 deep M12; tief


50 50.8 92 45 31.8 79

B SAE 1 1/4 Hochdruckreihe High-pressure range


M14; M14; 19 19 tief deep

For ccw - rotation, turn port plate 180

Ports B Pressure port SAE 1 1/4" (High-pressure range) S Inlet port SAE 2 1/2" (Standard pressure range) L/L1 Case drain 1 1/16-12UN-2B X Pilot port 7/16-20UNF-2B with control DR, pilot port X is plugged A10VO 15/24 Brueninghaus Hydromatik

32 66.7

139

88

93.5

RE 92 703/12.99

Unit dimensions, size 85


DR DRG DFR /52 R -X U C 12 N00 DFR1 62
171.5 130 40 12.7 20 1 1/16-12UN-2B

Prior to finalising your design, please request certified installation drawing. All rights reserved subject to revision.

Version A10VO 85

L1
Flange 127-2 Flansch 127-2 SAE J744 OCT 83

155.5

S SAE 2 1/2 standard pressure Standarddruckreihe range w. plate 12 bei Platte 12 M12; M12;17 17deep tief bei Platte 62 w. plate 62 1/2-13UNC-2B 1/2-13UNC-2B; 24deep tief 24

45

1 N 2U -1 16 1/ B -2

L
127h8 11/4 5/16-18UNC-2B

88.9 60

50.8 7.9 55.4 235.5 276.8

158 181 210

Shaft U 32-4; SAE J744 OCT 83 Welle

1 Keilwellengre; 30 Eingriffswinkel 11/4 1/4"splined shaft size; 30 pressure angle 14 Pitch-Tlg. 14Zhne; teeth; 12/24 DP

74

B SAE 1 1/4

Hochdruckreihe High-pressure range


66.7 32

139

View V Ansicht shown is V clockwise Drehrichtung rechts rotation

7/16-20UNF-2B

Ansicht View WW Anschluplatte 12/62 port plate 12/62 Drehrichtung rechts shown is clockwise rotation

11.5

w. plate bei Platte12 12 19 tief deep M14; 19 bei Platte62 62 w. plate 1/2-13UNC-2B; 1/2-13UNC-2B;19 19tief deep

31.8

95

85

For ccw - rotation, turn port plate 180

Ports B Pressure port SAE 1 1/4" (High-pressure range) S Inlet port SAE 2 1/2" (Standard pressure range) L/L1 Case drain 1 1/16-12UN-2B X Pilot port 7/16-20UNF-2B with control DR, pilot port X is plugged Brueninghaus Hydromatik 16/24 A10VO

88

19 35

96

17.5

93.5

RE 92 703/12.99

DR

Pressure control

The pressure control serves to maintain a constant pressure in the hydraulic system, within the control range of the pump. The pump therefore supplies only the amount of hydraulic fluid required by the actuators. Pressure may be steplessly set at the pilot valve. Dimensions see pages 8, 10 and 13 to 16.

Static characteristic (at n1 = 1500 rpm; toil = 50C) Hysteresis and pressure increase pmax 4 bar
qv max

Flow qv

L1

Setting range
qv min

20

250 Operating pressure p [bar]

Dynamic characteristics The curves show average measured values under test conditions, unit in the tank. Conditions: n = 1500 rpm toil = 50C Line relief valve set at 315 bar Jump loading by suddenly opening or closing the pressure line using a pressure relief valve at 1m downstream from the axial piston unit.

Operating pressure p [bar]

Control oil cosumption max. 3 L/min.

315 315 300 300 250 250 200 200

150 150
100 100 50 50 0 0
VV gmax g max

Displacement (swivel angel)

V V gmin g min

stroking time tSA Size 28 45 60 85 A10VO 17/24 tSA (ms) against 50 bar 70 85 100 on request

Control time t de-stroking time tSE tSE (ms) zero stroke 250 bar 20 20 25

tSA (ms) against 220 bar 65 75 85

Brueninghaus Hydromatik

RE 92 703/12.99

DRG

Pressure-remote control

Function and design as for DR. A pressure relief valve may be externally piped to port X for remote control purposes. It is not, however, included with the DRG control. The differential pressure at the pilot valve is set as standard to 20 bar and this results in a pilot flow of 1.5 L/min. If another setting is required (in the range 10 22 bar), please state this in clear text. We recommend that one of the following is used as the separate pressure relief valve: DBDH 6 (hydraulic) to RE 25402 or DBETR-SO 381 with 0.8 mm dia. nozzle in P (electrical) to RE 29166. The length of piping must not exceed 2 m. gehrt nicht zum Lieferumfang Not included in supply

Static characteristic (at n1 = 1500 rpm; toil = 50C) Hysteresis and pressure increase p
qv max

Flow qv

L1

Setting range
qv min

20 Operating pressure p [bar]

250

Unit dimensions see pages 8, 9 and 11 to 16.

Control data Hysteresis and repetitive accuracy p ........................... max. 3 bar Max. pressure increase Size 28 p bar 4

45 6

60 8

85 on request

Control oil consumption .................................... approx. 4.5 L/min Flow loss at qv max see page 6.

Brueninghaus Hydromatik

18/24

A10VO

RE 92 703/12.99

DFR/DFR1

Pressure/flow control
with DFR1 no bei DFR1 nicht vorhanden connection

In addition to the pressure control function, the pump flow may be varied by means of a differential pressure at the actuator (e.g. an orifice resp. mobile valve block s.b.; not included in supply). The pump flow is equal to the actual required flow by the actuator. The DFR1-valve has no connection between X and tank. Static characteristic (at n1 = 1500 rpm; toil = 50C)
qv (see table of values)

X
gehrt nicht zum Lieferumfang Not included in supply

qv max Flow qv

Setting range qv min 20 Operating pressure p [bar] 250

qv (see table of values)

Static characteristic at variable speed qv max Flow qv

L1

qv min

Speed n

n max (rpm)

Max. Flow deviation (hysteresis and increase) measured at drive speed n = 1500 rpm Size qv L/min 28 1.0 45 1.8 60 2.5 85 on request

Control oil consumption max. 3 L/min. Flow control/differential pressure p: Adjustable between 10 and 22 bar Standard setting: 14 bar. If a different setting is required, please state in clear text. When port X is unloaded to tank, a zero stroke pressure of p =18 2 bar ("stand by") results (dependent on p).

Dynamic characteristic of flow control The curves shown are measured average values under test conditions, with the unit within the tank. Displacement Vg (%) Load pressure p (bar)
100 75 50 25 0 100 50 18 315 250 200

Unit dimensions see pages 8, 9 and 11 to 16.

Optional valves at port B (not included in supply) LS - mobile valve blocks Mobile valve blocks M4- 12 Mobile valve blocks M4- 15 Mobile valve blocks SX 18 Mobile valve blocks MP 18 Mobile valve blocks MP 22 (RE 64278) (RE 64282) (RE 64127) (RA 64960) (RA 64980)

stroking time tSA Size 28 45 60 85 tSA (ms) stand by250 bar 80 100 120 on request

Control time t de-stroking time tSE

(stand by)

tSE (ms) 250 barstand by 20 25 30

tSE 50 barstand by 50 60 75

LUDV - mobile valve blocks* Mobile valve blocks M6 15 (RE 64284) Mobile valve blocks M7 22 (RE 64287) Mobile valve blocks SX 14 (RE data sheet currently in preparation) * The setting of the pump pressure control must be about 20 bar greater than the setting of the LS pressure limiting valve in the LUDV block. Brueninghaus Hydromatik

A10VO

19/24

RE 92 703/12.99

Through-drive
The A10VO axial piston unit can be supplied with through-drive in accordance with the ordering code on page 3. The through-drive version is designated by the code numbers (K01 K24). If no other pumps are fitted by the manufacturer, the simple type designation is sufficient. In this case, the delivery package comprises: Hub, fixing screws, seal. Combination pumps By mounting additional pumps, the user can use mutually independent circuits. If the combination pump consists of two A10V0 units and if these pumps should be supplied ready-assembled together, the two type designations should be joined by "+". Example order: A10VO 45 DR/52 LPSC62K04 + A10VO 45 DR/52 LPSC61N00 If you wish a gear pump to be factory-fitted as add-on pump, please contact us. Permissible moment of inertia

m1

m2

l1 l2
m1, m2 [kg] l1, l 2 [mm] Pump mass Centre-to-centre spacing 1 102 [Nm]
28 Tm Tm m1 l1 Nm Nm kg mm 14 81 18 95 22 100 34 122 45 60 85

Tm = ( m1 . l1 + m2 . l2 ) .
Size Permissible moment of inertia Permissible moment of inertia at dynamic mass acceleration 10 g 98.1 m/sec2 Mass Centre-to-centre spacing

Missing values available on request

Maximum permissible input and through-drive torque

Size

28

45

60 306

85 628

Max. permissible input torque at pump 1 with shaft "U" Nm 188 Ttot

The split in torque between pump 1 and 2 is optional. The max. permissible input torque Ttot as well as the max. permissible throughdrive torque T may not be exceeded.
D

Max. permissible through-drive torque Nm TD

188

Size

28

45

60 630 484

85 1157 778

Size

28

45

60 396 396

85

Max. permissible input torque at pump 1 with shaft "S" 198 319 Ttot Nm Max. permissible through-drive torque Nm TD 160 319

Max. permissible input torque at pump 1 with shaft "W" 220 Ttot Nm Max. permissible through-drive torque Nm TD 220

Size

28

45

60

85

Size

28

45

60 441

85

Max. permissible input torque at pump 1 with shaft "R" Nm 225 400 Ttot Max. permissible through-drive torque Nm TD 176 365

Max. permissible input torque at pump 1 with shaft "K" 145 212 Ttot Nm Max. permissible through-drive torque Nm TD 145 212

Missing values available on request

Brueninghaus Hydromatik

20/24

A10VO

RE 92 703/12.99

Unit dimensions of the combination pump and through-drive K01, K52


Prior to finalising your design, please request certified installation drawing. All rights reserved subject to revision.

A10VO + A10VO
A4

A1 A2 A3
Main pump Aux pump

A1 160 -

A10VO 28 A2 A3 204 374 -

A4 414 -

A1 178 178 -

A10VO 45 A2 A3 229 229 399 418 -

A4 439 445 -

A1 202 202 202 -

A10VO 60 A2 A3 255 255 255 425 444 463 -

A4 465 471 471 -

A1 236 236 236 236

A10VO 85 A2 A3

A4

A10VO 28 A10VO 45 A10VO 60 A10VO 85

302

537

537

Missing values available on request

Flange SAE 82-2 (SAE A, 2-hole) for adding an externally geared gear pump 1PF2G2 (see RE 10030) or an internally geared gear pump PGF2 (shaft J, flange U2, see RE 10213) Order designation K01 Flange SAE 82-2 (SAE A, 2-hole) for adding an A10VSO 10 (shaft S, flange C, see RE 92713) or an A10VSO 18 (shaft S, flange C, see RE 92712) Order designation K52 Schnitt SectionA-B A-B A4 bei NG 28 28 Notentfllt provided in size 8

Zahnnabe 5/8; Toothed hub 5/8"; 16/32 DP; 9T 9T bei for K01 Toothed hub 3/4"; Zahnnabe 3/4; 11T bei for K52 16/32 DP; 11T

45

106.

A5 10
entfllt bei NG 28 28 Not provided in size up Pumpenanflanschflche to pump flange surface AA bis 11

Main pump Size 28 45 60 A10VO

A1 204 229 255

A4 47 53 59

A5 M 10; 16 deep M 10; 16 deep M 10; 16 deep

in size 28, the variable displacement pump A10VSO18 can only be mounted at 45 angle. 21/24 Brueninghaus Hydromatik

82.55 +0.020

+0.050

RE 92 703/12.99

Dimensions of through-drives K02 and K68


Prior to finalising your design, please request certified installation drawing. All rights reserved subject to revision.

Flange SAE 101-2 (SAE B, 2-hole) for mounting an externally geared gear pump 1PF2G3 (see RE 10039) Order designation K02 Schnitt SectionA-B A-B A4 8
Zahnnabe 7/8; Toothed hub 7/8"; 16/32 16/32 DP; DP; 13T 13T

146

A5

10
up pump flange surface AA bis to Pumpenanflanschflche 11

Main pump Size A1 45 229

A4 53

A5 M 10; 16 deep

Flange SAE 101-2 (SAE B, 2-hole) for mounting an A10VO 28 (shaft S) or an internally geared gear pump PGF3 (shaft J, flange U2, see RE 10213) Order designation K68 Schnitt SectionA-B A-B A4
Not provided sizes 28 and entfllt bei in NG 28 und 45 45

8
Zahnnabe 7/8; Toothed hub 7/8"; 16/32 DP; 13T

A
146

A5 10
entfllt bei in NG 28 und 45 45 Not provided sizes 28 and bis Pumpenanflanschflche up to pump flange surface AA 11

Main pump Size A1 28 204 45 229 60 255

A4 47 53 59

A5 M 12; 18 deep M 12; 18 deep M 12; 18 deep 22/24 A10VO

Brueninghaus Hydromatik

101.6 +0.020

+0.050

101.6 +0.020

+0.050

45

RE 92 703/12.99

Dimensions of through-drives K04 and K15


Prior to finalising your design, please request certified installation drawing. All rights reserved subject to revision.

Flange SAE 101-2 (SAE B, 2-hole) for mounting an A10VO 45 - shaft S, or an internally geared gear pump PGH4 (shaft J, flange U2, see RE 10223) Order designation K04 Section A-B Schnitt A-B
Not provided size entfllt bei in NG 45 45

A4 8

Zahnnabe 1;1"; Toothed hub 16/32 DP; 15 Zhne teeth

A
146

A5
Not provided size entfllt bei in NG 45 45

10
up to pump flange surface AA bis Pumpenanflanschflche 11

Main pump Size A1 45 229 60 255

A4 53 59

A5 M 12; 18 deep M 12; 18 deep

Flange SAE 127-4 (SAE C) for mounting an A10VO 60 (shaft S, mounting flange D) Order designation K15

Schnitt A-B Section A-B Main pump size 60 59 8

101.6 +0.020
Zahnnabe 1 1/4; Toothed hub 1 1/4"; 12/24 12/24 DP; DP; 14 14 Zhne teeth

114.5

M12
bis Pumpenanflanschflche up to pump flange surface 255 225

13

A10VO

23/24

127 +0.020 Brueninghaus Hydromatik

114.5

+0.050

+0.050

45

RE 92 703/12.99

Dimensions of through-drives K24


Prior to finalising your design, please request certified installation drawing. All rights reserved subject to revision.

Flange SAE 127-2 (SAE C) for mounting an A10VO 85 - shaft S, or an internally geared gear pump PGH5 (shaft J, flange U2, see RE 10223) Order designation K24 Schnitt SectionA-B A-B
45

A4 A3

Zahnnabe 1 1/2; Toothed hub 1 1/2"; 12/24 DP; 17 Zhne teeth

A5

B
13
bis up Pumpenanflanschflche to pump flange surface AA 11

Main pump Size A1 85 302

A3 8

A4 68

A5 M 16; 24 deep

Preferred types (shorter delivery times) When ordering, please quote type and ID number. Type A10VO 45 DFR/52R-PSC64N00 A10VO 60 DFR1/52R-PSD61N00 ID number 970 014 974 886

Brueninghaus Hydromatik GmbH Horb Plant An den Kelterwiesen 14 D72160 Horb Telefon +49 (0) 74 51 / 92-0 Telefax +49 (0) 74 51 / 82 21

The specified data is for product description purposes only and may not be deemed to be guaranteed unless expressly confirmed in the contract.

All rights reserved Subject to revision

24/24

127 +0.020

+0.050

181

A10VO

Potrebbero piacerti anche