TABLE 5.1.1(a)
DIMENSIONS AND FULL SECTION PROPERTIES
DIMENSIONS
Designation
Mass
Nominal per
Leg Size Thickmetre
b1
b 2 ness
Actual
Thickness
t
Inside
Corner
Radius
ri
mm mm mm
kg/m
mm
mm
18.0
10.8
8.0
4.7
8.0
4.0
14.9
8.95
7.27
8.0
4.7
3.8
8.0
4.0
4.0
11.7
8.92
10.5
6.37
8.59
6.56
5.26
4.29
8.0
6.0
8.0
4.7
8.0
6.0
4.7
3.8
8.0
8.0
8.0
4.0
8.0
8.0
4.0
4.0
NOTES:
CA#
CA#
CA
CA
CA
CA
CA
CA
SECTION PROPERTIES
Co-ordinates
of
Centroid
y1 = y4
x2 = x3
mm
x5
Full
Area of
Section
Af
2
About x-axis
Ix
6
10 mm
Sx
3
10 mm
rx
3
Iy
6
Zy2 = Zy3
4
Zy5
3
Sy
3
ry
3
mm
mm
mm
mm
10 mm
10 mm
10 mm
10 mm
53.5
53.4
51.6
52.4
2290
1380
8.30
5.04
78.3
47.6
120
72.4
60.2
60.6
1.96
1.23
36.7
23.0
38.1
23.4
58.2
35.6
29.3
29.9
88.4
88.4
88.4
44.6
44.5
44.4
42.8
43.6
43.4
1890
1140
926
4.73
2.89
2.36
53.5
32.7
26.7
82.7
50.0
40.7
50.0
50.4
50.5
1.11
0.699
0.572
24.7
15.7
12.9
25.8
16.0
13.2
39.6
24.4
19.9
24.1
24.8
24.9
70.7
70.7
63.6
63.6
53.0
53.0
53.0
53.0
35.8
35.5
32.3
32.2
26.9
26.7
26.8
26.7
33.9
33.6
30.4
31.2
25.1
24.8
25.9
25.8
1490
1140
1330
811
1090
836
670
546
2.36
1.83
1.70
1.06
0.957
0.747
0.601
0.495
33.4
25.8
26.7
16.6
18.0
14.1
11.3
9.34
52.0
39.8
41.7
25.5
28.4
21.9
17.5
14.3
39.8
40.1
35.7
36.1
29.6
29.9
30.0
30.1
0.542
0.421
0.386
0.252
0.213
0.167
0.142
0.117
15.1
11.9
12.0
7.83
7.89
6.26
5.29
4.39
16.0
12.5
12.7
8.06
8.46
6.73
5.48
4.55
24.7
19.0
19.7
12.4
13.2
10.2
8.44
6.93
19.0
19.3
17.0
17.6
13.9
14.1
14.6
14.7
106
106
10 mm
Zx1 = Zx4
4
About y-axis
mm
November 2004
1. Steel grade C450L0 / C400L0 / C350L0 (for t 2.5 mm fy = 350 MPa and fu = 400 MPa, for 2.5 mm < t 6.0 mm fy = 450 MPa and fu = 500 MPa, and for t > 6.0 mm fy = 400 MPa and
fu = 450 MPa).
2. Full section properties are calculated in accordance with AS/NZS 4600.
3. Sizes shown in Italics may not be stocked in all states or minimum order quanitites may apply.
4. # are also available as DuraGal Plus (Lintels). Refer to the Product Information section at the front of this publication.
November 2004
TABLE 5.1.1(b)
DIMENSIONS AND FULL SECTION PROPERTIES
DIMENSIONS
Designation
Mass
Nominal per
Leg Size Thickmetre
b1
b2 ness
mm mm mm
Actual
Thickness
t
Inside
Corner
Radius
ri
SECTION PROPERTIES
Co-ordinates
of
Centroid
y1 = y4
x2 = x3
x5
Full
Area of
Section
Af
Ix
6
Zx1 = Zx4
4
About y-axis
Sx
3
rx
3
Iy
6
Zy2 = Zy3
4
10 mm
Zy5
3
Sy
3
ry
3
kg/m
mm
mm
mm
mm
mm
10 mm
10 mm
10 mm
mm
10 mm
10 mm
10 mm
mm
65 x 65 x 6.0 CA
5.0 CA
4.0 CA
5.62
4.52
3.69
6.0
4.7
3.8
8.0
4.0
4.0
46.0
46.0
46.0
23.1
23.3
23.2
21.3
22.4
22.2
716
576
470
0.477
0.386
0.318
10.4
8.39
6.93
16.2
13.0
10.7
25.8
25.9
26.0
0.104
0.0902
0.0747
4.52
3.87
3.22
4.91
4.03
3.36
7.50
6.24
5.13
12.1
12.5
12.6
50 x 50 x 6.0
5.0
4.0
2.5
CA
CA
CA
CA
4.21
3.42
2.79
1.81
6.0
4.7
3.8
2.4
8.0
4.0
4.0
2.5
35.4
35.4
35.4
35.4
17.8
18.0
17.9
17.8
16.0
17.1
16.9
17.2
536
435
356
230
0.208
0.170
0.141
0.0930
5.89
4.80
3.99
2.63
9.29
7.53
6.20
4.04
19.7
19.8
19.9
20.1
0.0434
0.0389
0.0324
0.0221
2.44
2.16
1.81
1.24
2.71
2.28
1.91
1.28
4.18
3.56
2.94
1.95
9.00
9.45
9.54
9.79
45 x 45 x 4.0 CA
2.5 CA
2.50
1.62
3.8
2.4
4.0
2.5
31.8
31.8
16.1
16.0
15.2
15.4
318
206
0.102
0.0673
3.19
2.11
4.98
3.25
17.9
18.1
0.0231
0.0159
1.43
0.990
1.52
1.03
2.35
1.57
8.52
8.77
40 x 40 x 4.0 CA
2.5 CA
2.20
1.43
3.8
2.4
4.0
2.5
28.3
28.3
14.3
14.3
13.4
13.7
280
182
0.0702
0.0468
2.48
1.65
3.89
2.55
15.8
16.0
0.0157
0.0110
1.10
0.768
1.17
0.801
1.82
1.22
7.50
7.75
30 x 30 x 2.5 CA
1.06
2.4
2.5
21.2
10.7
10.2
134
0.0191
0.902
1.40
11.9
0.00438
0.408
0.431
0.664
5.71
NOTES:
mm
About x-axis
1. Steel grade C450L0 / C400L0 / C350L0 (for t 2.5 mm fy = 350 MPa and fu = 400 MPa, for 2.5 mm < t 6.0 mm fy = 450 MPa and fu = 500 MPa, and for t > 6.0 mm fy = 400 MPa and
fu = 450 MPa).
2. Full section properties are calculated in accordance with AS/NZS 4600.
33
ANGLE
ANGLE
34
TABLE 5.1.1(c)
DIMENSIONS AND FULL SECTION PROPERTIES
Mass
per
metre
Actual Inside
Thick- Corner
ness Radius
t
ri
SECTION PROPERTIES
Coordinates
of
Centroid
pB = nL
pT = nR
mm mm mm
kg/m
mm
mm
mm
18.0
10.8
8.0
4.7
8.0
4.0
41.2
39.6
14.9
8.95
7.27
8.0
4.7
3.8
8.0
4.0
4.0
34.9
33.4
33.0
11.7
8.92
10.5
6.37
8.59
6.56
5.26
4.29
8.0
6.0
8.0
4.7
8.0
6.0
4.7
3.8
8.0
8.0
8.0
4.0
8.0
8.0
4.0
4.0
28.7
27.9
26.2
24.6
22.5
21.7
20.9
20.5
NOTES:
CA#
CA#
CA
CA
CA
CA
CA
CA
mm
109
110
Full
Area of
Section
Af
mm
rn = rp
Product of
2nd Moment
of Area
Inp
In = Ip
6
ZnB = ZpL
4
10 mm
ZnT = ZpR
3
Sn = Sp
3
10 mm
10 mm
10 mm
mm
106 mm4
2290
1380
5.13
3.14
125
79.1
47.2
28.4
85.2
51.2
47.3
47.7
-3.17
-1.91
90.1
91.6
92.0
1890
1140
926
2.92
1.80
1.47
83.5
53.8
44.5
32.4
19.6
16.0
58.5
35.3
28.8
39.2
39.7
39.8
-1.81
-1.10
-0.896
71.3
72.1
63.8
65.4
52.5
53.3
54.1
54.5
1490
1140
1330
811
1090
836
670
546
1.45
1.12
1.04
0.654
0.585
0.457
0.372
0.306
50.6
40.3
39.8
26.6
26.0
21.1
17.8
14.9
20.4
15.6
16.3
10.0
11.1
8.57
6.86
5.62
36.8
28.2
29.5
18.0
20.1
15.5
12.4
10.1
31.2
31.5
27.9
28.4
23.1
23.4
23.5
23.7
-0.910
-0.703
-0.657
-0.402
- 0.372
- 0.290
- 0.230
- 0.189
November 2004
1. Steel grade C450L0 / C400L0 / C350L0 (for t 2.5 mm fy = 350 MPa and fu = 400 MPa, for 2.5 mm < t 6.0 mm fy = 450 MPa and fu = 500 MPa, and for t > 6.0 mm fy = 400 MPa and
fu = 450 MPa).
2. Full section properties are calculated in accordance with AS/NZS 4600.
3. Sizes shown in Italics may not be stocked in all states or minimum order quanitites may apply.
4. # are also available as DuraGal Plus (Lintels). Refer to the Product Information section at the front of this publication.
November 2004
TABLE 5.1.1(d)
DIMENSIONS AND FULL SECTION PROPERTIES
DIMENSIONS
Designation
Nominal
Leg Size Thickb1
b 2 ness
mm mm mm
Mass
per
metre
Actual Inside
Thick- Corner
ness Radius
t
ri
SECTION PROPERTIES
Coordinates
of
Centroid
pB = nL
pT = nR
Full
Area of
Section
Af
11.5
9.22
7.56
20.2
20.3
20.5
- 0.186
- 0.148
- 0.122
8.15
7.14
6.08
4.23
3.64
2.95
2.43
1.58
6.59
5.33
4.39
2.86
15.3
15.5
15.6
15.8
0.0623
0.0416
4.79
3.36
1.95
1.27
3.52
2.30
14.0
14.2
- 0.0392
- 0.0257
280
182
0.0430
0.0289
3.65
2.60
1.52
0.999
2.75
1.80
12.4
12.6
- 0.0272
- 0.0179
134
0.0118
1.37
0.550
0.994
mm
65 x 65 x 6.0 CA
5.0 CA
4.0 CA
5.62
4.52
3.69
6.0
4.7
3.8
8.0
4.0
4.0
19.2
18.4
18.0
45.8
46.6
47.0
50 x 50 x 6.0
5.0
4.0
2.5
CA
CA
CA
CA
4.21
3.42
2.79
1.81
6.0
4.7
3.8
2.4
8.0
4.0
4.0
2.5
15.4
14.6
14.3
13.6
45 x 45 x 4.0 CA
2.5 CA
2.50
1.62
3.8
2.4
4.0
2.5
40 x 40 x 4.0 CA
2.5 CA
2.20
1.43
3.8
2.4
4.0
2.5
30 x 30 x 2.5 CA
1.06
2.4
2.5
10 mm
10 mm
716
576
470
0.291
0.238
0.197
15.2
13.0
10.9
34.6
35.4
35.7
36.4
536
435
356
230
0.126
0.104
0.0868
0.0576
13.0
12.4
32.0
32.6
318
206
11.8
11.1
28.2
28.9
21.4
8.61
rn = rp
6.35
5.10
4.18
mm
Sn = Sp
10 6 mm4
mm
ZnT = ZpR
mm
mm
ZnB = ZpL
10 mm
mm
NOTES:
In = Ip
10 mm
kg/m
Product of
2nd Moment
of Area
Inp
9.35
0.0823
0.0655
0.0544
0.0355
- 0.00738
1. Steel grade C450L0 / C400L0 / C350L0 (for t 2.5 mm fy = 350 MPa and fu = 400 MPa, for 2.5 mm < t 6.0 mm fy = 450 MPa and fu = 500 MPa, and for t > 6.0 mm fy = 400 MPa and
fu = 450 MPa).
2. Full section properties are calculated in accordance with AS/NZS 4600.
35
ANGLE
ANGLE
TABLE 5.1.2(a)
36
DIMENSIONS
RATIOS
Designation
Nominal
Leg Size Thickb1
b 2 ness
Mass
per
metre
mm mm mm
kg/m
mm
mm
18.0
10.8
8.0
4.7
16.0
8.7
16.8
30.1
14.9
8.95
7.27
8.0
4.7
3.8
16.0
8.7
7.8
11.7
8.92
10.5
6.37
8.59
6.56
5.26
4.29
8.0
6.0
8.0
4.7
8.0
6.0
4.7
3.8
16.0
14.0
16.0
8.7
16.0
14.0
8.7
7.8
NOTES:
CA#
CA#
CA
CA
CA
CA
CA
CA
Actual Outside
Thick- Corner
ness Radius
t
ro
GRADE
Yield
Stress
fy
Effective
Area of
Section
Ae
MPa
mm2
16.8
30.1
400
450
1610
572
13.6
24.7
30.8
13.6
24.7
30.8
400
450
450
10.5
14.3
9.25
17.3
7.38
10.2
14.1
17.7
10.5
14.3
9.25
17.3
7.38
10.2
14.1
17.7
400
450
400
450
400
450
450
450
b1 - ro
t
b2 - ro
t
About x-axis
Ae
Af
About y-axis
Iex1 = Iex4
Zex1 = Zex4
Iey2,3
Zey2,3
Iey5
Zey5
106 mm4
103mm3
106mm4
10 3mm3
106 mm4
103 mm3
0.701
0.416
5.74
1.99
60.8
25.3
1.56
0.544
31.4
13.2
1.96
1.23
36.7
23.0
1530
560
379
0.809
0.491
0.409
3.90
1.34
0.917
46.9
19.4
14.0
1.05
0.368
0.248
23.9
10.2
7.31
1.11
0.699
0.572
24.7
15.7
12.9
1410
859
1330
530
1090
781
508
353
0.946
0.756
1.00
0.654
1.00
0.934
0.759
0.646
2.36
1.38
1.70
0.672
0.957
0.735
0.458
0.310
33.4
21.3
26.7
12.2
18.0
13.9
9.41
6.78
0.542
0.363
0.386
0.185
0.213
0.167
0.125
0.0840
15.1
10.7
12.0
6.33
7.89
6.26
4.84
3.49
0.542
0.421
0.386
0.252
0.213
0.167
0.142
0.117
15.1
11.9
12.0
7.83
7.89
6.26
5.29
4.39
November 2004
1. Steel grade C450L0 / C400L0 / C350L0 (for t 2.5 mm fy = 350 MPa and fu = 400 MPa, for 2.5 mm < t 6.0 mm fy = 450 MPa and fu = 500 MPa, and for t > 6.0 mm fy = 400 MPa and
fu = 450 MPa).
2. Ae is calculated for sections with uniform axial compressive stress fy.
3. Ie and Ze are calculated with the extreme compression or tension fibres at fy (first yield). Ze is calculated at the extreme tension or compression fibre of the effective section.
4. Iex1 and Zex1 are for compression at point "1"; Iex4 and Zex4 are for compression at point "4"; Iey2,3 and Zey2,3 are for compression at points "2" and "3"; Iey5 and Zey5 are for compression at
point "5".
5. Effective section properties are calculated in accordance with AS/NZS 4600.
6. Sizes shown in Italics may not be stocked in all states or minimum order quanitites may apply.
7. # are also available as DuraGal Plus (Lintels). Refer to the Product Information section at the front of this publication.
November 2004
TABLE 5.1.2(b)
EFFECTIVE SECTION PROPERTIES
DIMENSIONS
Designation
Nominal
Leg Size Thickb1
b 2 ness
mm mm mm
Mass
per
metre
RATIOS
Actual Outside
Thick- Corner
ness Radius
t
ro
Yield
Stress
b 1 - ro
t
kg/m
mm
mm
65 x 65 x 6.0 CA
5.0 CA
4.0 CA
5.62
4.52
3.69
6.0
4.7
3.8
14.0
8.7
7.8
8.50
12.0
15.1
50 x 50 x 6.0
5.0
4.0
2.5
CA
CA
CA
CA
4.21
3.42
2.79
1.81
6.0
4.7
3.8
2.4
14.0
8.7
7.8
4.9
45 x 45 x 4.0 CA
2.5 CA
2.50
1.62
3.8
2.4
40 x 40 x 4.0 CA
2.5 CA
2.20
1.43
30 x 30 x 2.5 CA
1.06
NOTES:
GRADE
b2 - ro
t
fy
MPa
mm
8.50
12.0
15.1
450
450
450
716
487
342
6.00
8.79
11.1
18.8
6.00
8.79
11.1
18.8
450
450
450
350
7.8
4.9
9.79
16.7
9.79
16.7
3.8
2.4
7.8
4.9
8.47
14.6
2.4
4.9
10.5
About x-axis
Ae
Af
Iex1 = Iex4
6
About y-axis
Zex1 = Zex4
3
Iey2,3
6
10 mm
Zey2,3
4
Iey5
3
10 mm
Zey5
4
10 mm
103mm3
10 mm
10 mm
1.00
0.846
0.727
0.477
0.337
0.230
10.4
7.65
5.54
0.104
0.0902
0.0619
4.52
3.87
2.83
0.104
0.0902
0.0747
4.52
3.87
3.22
536
435
316
156
1.00
1.00
0.888
0.676
0.208
0.170
0.131
0.0615
5.89
4.80
3.78
1.98
0.0434
0.0389
0.0324
0.0169
2.44
2.16
1.81
1.03
0.0434
0.0389
0.0324
0.0221
2.44
2.16
1.81
1.24
450
350
303
152
0.952
0.736
0.102
0.0494
3.19
1.71
0.0231
0.0135
1.43
0.884
0.0231
0.0159
1.43
0.990
8.47
14.6
450
350
280
147
1.00
0.806
0.0702
0.0385
2.48
1.45
0.0157
0.0104
1.10
0.740
0.0157
0.0110
1.10
0.768
10.5
350
132
0.980
0.0191
0.902
0.00438
0.408
0.00438
0.408
1. Steel grade C450L0 / C400L0 / C350L0 (for t 2.5 mm fy = 350 MPa and fu = 400 MPa, for 2.5 mm < t 6.0 mm fy = 450 MPa and fu = 500 MPa, and for t > 6.0 mm fy = 400 MPa and
fu = 450 MPa).
2. Ae is calculated for sections with uniform axial compressive stress fy.
3. Ie and Ze are calculated with the extreme compression or tension fibres at fy (first yield). Ze is calculated at the extreme tension or compression fibre of the effective section.
4. Iex1 and Zex1 are for compression at point "1"; Iex4 and Zex4 are for compression at point "4"; Iey2,3 and Zey2,3 are for compression at points "2" and "3"; Iey5 and Zey5 are for compression at
point "5".
5. Effective section properties are calculated in accordance with AS/NZS 4600.
37
ANGLE
ANGLE
38
TABLE 5.1.2(c)
EFFECTIVE SECTION PROPERTIES
DIMENSIONS
Designation
Nominal
Leg Size Thickb1
b 2 ness
Mass
per
metre
RATIOS
Actual Outside
Thick- Corner
ness Radius
t
ro
Yield
Stress
b1 - ro
t
mm mm mm
kg/m
mm
mm
18.0
10.8
8.0
4.7
16.0
8.7
16.8
30.1
14.9
8.95
7.27
8.0
4.7
3.8
16.0
8.7
7.8
11.7
8.92
8.0
6.0
90 x 90 x 8.0 CA
5.0 CA
10.5
6.37
8.59
6.56
5.26
4.29
75 x 75 x 8.0
6.0
5.0
4.0
NOTES:
CA
CA
CA
CA
GRADE
b2 - ro
t
fy
Ae
Af
IenT = IepR
6
5.04
2.57
46.8
25.9
2.34
0.594
0.357
27.8
9.13
6.01
2.92
1.57
1.20
32.4
18.4
14.5
0.946
0.756
1.45
0.782
20.4
12.1
1.45
1.12
20.4
15.6
1330
530
1.00
0.654
1.04
0.357
16.3
6.58
1.04
0.629
16.3
9.83
1090
781
508
353
1.00
0.934
0.759
0.646
0.585
0.457
0.266
0.162
16.8
30.1
400
450
1610
572
0.701
0.416
3.17
0.791
13.6
24.7
30.8
13.6
24.7
30.8
400
450
450
1530
560
379
0.809
0.491
0.409
16.0
14.0
10.5
14.3
10.5
14.3
400
450
1410
859
8.0
4.7
16.0
8.7
9.25
17.3
9.25
17.3
400
450
8.0
6.0
4.7
3.8
16.0
14.0
8.7
7.8
400
450
450
450
7.38
10.2
14.1
17.7
10 mm
11.1
8.57
5.45
3.62
0.585
0.457
0.372
0.293
ZenB = ZepL
33.8
11.0
10 mm
IenB = IepL
103 mm3
mm
7.38
10.2
14.1
17.7
ZenT = ZepR
10 mm
MPa
11.1
8.57
6.86
5.51
November 2004
1. Steel grade C450L0 / C400L0 / C350L0 (for t 2.5 mm fy = 350 MPa and fu = 400 MPa, for 2.5 mm < t 6.0 mm fy = 450 MPa and fu = 500 MPa, and for t > 6.0 mm fy = 400 MPa and
fu = 450 MPa).
2. Ae is calculated for sections with uniform axial compressive stress fy.
3. Ie and Ze are calculated with the extreme compression or tension fibres at fy (first yield). Ze is calculated at the extreme tension or compression fibre of the effective section.
4. IenT and ZenT are for compression at point "T"; IenB and ZenB are for compression at point "B"; IepR and ZepR are for compression at point "R"; IepL and ZepL are for compression at point "L".
5. Effective section properties are calculated in accordance with AS/NZS 4600.
6. Sizes shown in Italics may not be stocked in all states or minimum order quanitites may apply.
7. # are also available as DuraGal Plus (Lintels). Refer to the Product Information section at the front of this publication.
November 2004
TABLE 5.1.2(d)
EFFECTIVE SECTION PROPERTIES
DIMENSIONS
Designation
Nominal
Leg Size Thickb1
b 2 ness
mm mm mm
Mass
per
metre
RATIOS
Actual Outside
Thick- Corner
ness Radius
t
ro
Yield
Stress
b 1 - ro
t
kg/m
mm
mm
65 x 65 x 6.0 CA
5.0 CA
4.0 CA
5.62
4.52
3.69
6.0
4.7
3.8
14.0
8.7
7.8
8.50
12.0
15.1
50 x 50 x 6.0
5.0
4.0
2.5
CA
CA
CA
CA
4.21
3.42
2.79
1.81
6.0
4.7
3.8
2.4
14.0
8.7
7.8
4.9
45 x 45 x 4.0 CA
2.5 CA
2.50
1.62
3.8
2.4
40 x 40 x 4.0 CA
2.5 CA
2.20
1.43
30 x 30 x 2.5 CA
1.06
NOTES:
GRADE
b2 - ro
t
fy
Ae
Af
IenT = IepR
6
ZenT = ZepR
6.35
4.65
3.13
0.291
0.238
0.195
6.35
5.10
4.17
0.126
0.104
0.0821
0.0333
3.64
2.95
2.34
1.08
0.126
0.104
0.0868
0.0560
3.64
2.95
2.43
1.56
0.952
0.736
0.0623
0.0281
1.95
0.972
0.0623
0.0414
1.95
1.27
280
147
1.00
0.806
0.0430
0.0231
1.52
0.856
0.0430
0.0289
1.52
0.999
132
0.980
0.0118
0.550
0.0118
0.550
10 mm
8.50
12.0
15.1
450
450
450
716
487
342
1.00
0.846
0.727
0.291
0.208
0.129
6.00
8.79
11.1
18.8
6.00
8.79
11.1
18.8
450
450
450
350
536
435
316
156
1.00
1.00
0.888
0.676
7.8
4.9
9.79
16.7
9.79
16.7
450
350
303
152
3.8
2.4
7.8
4.9
8.47
14.6
8.47
14.6
450
350
2.4
4.9
10.5
10.5
350
10 mm
ZenB = ZepL
103 mm3
mm
IenB = IepL
10 mm
MPa
1. Steel grade C450L0 / C400L0 / C350L0 (for t 2.5 mm fy = 350 MPa and fu = 400 MPa, for 2.5 mm < t 6.0 mm fy = 450 MPa and fu = 500 MPa, and for t > 6.0 mm fy = 400 MPa and
fu = 450 MPa).
2. Ae is calculated for sections with uniform axial compressive stress fy.
3. Ie and Ze are calculated with the extreme compression or tension fibres at fy (first yield). Ze is calculated at the extreme tension or compression fibre of the effective section.
4. IenT and ZenT are for compression at point "T"; IenB and ZenB are for compression at point "B"; IepR and ZepR are for compression at point "R"; IepL and ZepL are for compression at point "L".
5. Effective section properties are calculated in accordance with AS/NZS 4600.
39
ANGLE
TABLE 5.1.3
SECTION PROPERTIES for MEMBER STABILITY
Designation
Nominal
Leg Size Thickb1
b2 ness
Mass
per
metre
Torsion
Constant
Coordinate
of
Shear Centre
xo
Polar Radius of
Gyration about the
Shear Centre
ro1
Monosymmetry
Section
Constant
y
mm mm mm
kg/m
103 mm4
mm
mm
mm
18.0
10.8
49.0
10.1
51.6
52.2
84.3
85.2
206
209
14.9
8.95
7.27
40.4
8.39
4.46
42.8
43.4
43.5
69.9
70.8
71.1
171
173
174
11.7
8.92
10.5
6.37
8.59
6.56
5.26
4.29
31.9
13.6
28.5
5.97
23.4
10.0
4.93
2.63
33.9
34.3
30.4
31.0
25.1
25.5
25.7
25.8
55.4
56.0
49.7
50.6
41.0
41.6
41.9
42.2
136
137
122
124
100
102
103
103
65 x 65 x 6.0 CA
5.0 CA
4.0 CA
5.62
4.52
3.69
8.59
4.24
2.26
21.9
22.2
22.3
35.8
36.2
36.4
87.7
88.6
89.2
50 x 50 x 6.0
5.0
4.0
2.5
CA
CA
CA
CA
4.21
3.42
2.79
1.81
6.43
3.20
1.71
0.442
16.6
16.8
17.0
17.3
27.1
27.5
27.8
28.2
66.5
67.4
68.0
69.0
45 x 45 x 4.0 CA
2.5 CA
2.50
1.62
1.53
0.396
15.2
15.5
24.9
25.3
61.0
61.9
40 x 40 x 4.0 CA
2.5 CA
2.20
1.43
1.35
0.350
13.5
13.7
22.0
22.4
53.9
54.9
30 x 30 x 2.5 CA
1.06
0.258
10.2
16.6
40.7
ANGLE
NOTES:
40
CA#
CA#
CA
CA
CA
CA
CA
CA
1. Steel grade C450L0 / C400L0 / C350L0 (for t 2.5 mm fy = 350 MPa and fu = 400 MPa, for 2.5 mm < t 6.0 mm fy = 450
MPa and fu = 500 MPa, and for t > 6.0 mm fy = 400 MPa and fu = 450 MPa).
2. With the exception of J, properties are calculated assuming a simplified shape where the bends are eliminated and the
section is represented by straight mid-lines in accordance with Clause 2.1.2.1 of AS/NZS 4600.
3. bx is zero for equal angles.
4. Iw is equal to zero for angles.
5. The shear centre is assumed to be located at the intersection of the centre lines of the angle legs.
6. Sizes shown in Italics may not be stocked in all states or minimum order quanitites may apply.
7. # are also available as DuraGal Plus (Lintels). Refer to the Product Information section at the front of this publication.