Sei sulla pagina 1di 2

Alcatel-Lucent 1521 FLIP

FIBER LINE IP SYSTEM 4 X E1 AND 100 MB/S ETHERNET | RELEASE 4.0

The Alcatel-Lucent 1521 FLIP optical line system is a powerful optical access system that supports classical E1 and Ethernet connections.

The Alcatel-Lucent 1521 FLIP supports the migration from a circuit-switched to a converged packet-switched access network, offering both E1 and Ethernet. It also enables carriers to increase revenue by introducing new Ethernetbased services in parallel with their traditional E1 services. The Alcatel-Lucent 1521 FLIP S9 version has full management support from the Alcatel-Lucent 1353 LineView, which is a user-friendly, IP/SNMP-based Element Management System (EMS)*.

B E N E F I T S
Combines Ethernet and E1 on the same access ber link by encapsulating E1 data into Fast Ethernet frames with the E1 frames being given highest priority Physical level of security and separation between the Ethernet ports, allowing only the trafc between the Ethernet ports and the F/O link Powerful diagnostic tools provided by FEF (Far End Fault) signaling, SLE (Subscriber Link Emulation), Loop-Back and Last Gasp Variety of single mode ber interfaces with distances ranging up to 100 km For easy and economical installation, the CPE is half-rack size for installation in rack-mount or desktop mode Easily manageable either by the Alcatel-Lucent 1353 LineView for S9 versions or by using dipswitches for conguring desktop-to-desktop links

F E A T U R E S
4 x E1 and 4x Ethernet Distances between 2 and 100 km Fiber link capacity 100 Mb/s Extensive remote monitoring and control Rate limiting for comprehensive SLA implementation VLANs (per port and tagging) for user separation Easy to deploy and manage

* For more information, please refer to the Alcatel-Lucent 1353 LineView EMS data sheet.

T E C H N I C A L
Applications
Business access offering Ethernet and PABX interconnections Mobile backhaul requiring E1 and Ethernet (typically for connecting to GSM/UMTS and hotspot devices) Digital loop carrier (DLC) backhaul Enterprise applications Trunk and access lines in utility networks

S P E C I F I C A T I O N S
IEEE802.1p&q Frame Size: 1,916 bytes maximum 1K MAC Addresses
O P T I C A L I N T E R FAC E

Environmental and Physical


C L I M AT I C A N D M E C H A N I C A L CONDITIONS

1521 FLIP Variants


S 9 B OA R D

100Base-FX port Duplex SC connector (ST optional) Far End Fault Signaling

Features
Diagnostics per 10/100TX port FX port: Link/Activity TX port: S9 Board Link/Activity Desktop: Link/Activity, FDX, 100M
D I AG N O S T I C S P E R E 1

Operating temperature: S9 board: -5 C to +45 C Desktop: 0 C to 45 C Storage temperature S9 board: -5 C to +45 C Desktop: -20 C to +80 C Humidity: 10% to 90% non-condensing

SM SM SM SM SM SM SM SM SM SM SM SM

1310 1310 1310 1310 1310 1550 1310 1310 1310 1310 1310 1550

nm, duplex nm, duplex nm, duplex nm, duplex nm, duplex nm, duplex nm, duplex nm, duplex nm, duplex nm, duplex nm, duplex nm, duplex

SC, 7 km SC, 15 km SC, 25 km FC, 40 km SC, 70 km SC, 100 km SC, 7 km SC, 15 km SC, 25 km SC, 40 km SC, 70 km SC, 100 km

D E S K TO P

Interfaces
E 1 I N T E R FAC E S

Safety
EN/IEC 60950-1:2001 S9 blade: K20 Desktop: K20/K21

Supports HDB3 Coding Types Waveforms meet G.703 Transmit return loss specifications ETSI-300166, G703 Jitter as per ETSI CTR12/13, ITU G.736-G.739, G.823-G.824, G.703, ETSI 300011 and ITU-TI.431 LOS per ITU G.775, ETSI 300233I.431 E1 -delay: Total link latency (4x E1 devices, excluding signal over fiber propagation) <970 seconds maximum Bandwidth requirement per E1: ~ 3 Mb/s
C O N N E C TO R T Y P E S ( S 9 S H E L F )

EMC
EMC-ETSI EN 300 386: V1.3.3 (2005) with EN55022 (CISPR16): 1998 Class A Device

Local signal, loss of signal (LOS)


D I AG N O S T I C S P E R S YS T E M

Power, MA Active
CONVERSION METHOD

Buffered media domain (BMD), full wire speed, 1K MAC addresses, FDX flow control, HDX back-pressure flow control, SLE per user port
DIP SWITCHES

Dimensions
S 9 P L U G - I N B OA R D

4 x BNC for 75 4 x 9-pin D-sub for 120 ohm 1 x RJ-45 for Ethernet at S9 board
C O N N E C TO R T Y P E S (S9 1U SHELF)

TP1: A/N, 10/100,Duplex VLAN ports default setup Far- End -Fault en/disable reset device E1 Loop-Back en/disable

Height: 233 mm (9.17 in.) Width: 35 mm (1.37 in.) Depth: 160 mm (6.30 in.) Weight: 0.35 kg (.77 lb.)
D E S K TO P U N I T

4 x BNC for 75 ohm 4 x RJ-45 for 120 ohm 1 x RJ-45 for Ethernet at S9 board
C O N N E C TO R T Y P E S ( D E S K TO P UNIT)

Height: 44 mm (1.73 in.) Width: 223 (8.78 in.) Depth: 150 mm (5.90 in.) Weight: 0.63 kg (1.39 lb.)
I N S TA L L AT I O N M O D E S

Power
S U P P LY VO LTAG E

4 x RJ-48 for 120 ohm up to 210 m (655 ft) 4 x RJ-45 for Ethernet
E T H E R N E T I N T E R FAC E S

Internal, 100 V to 240 V AC, 50 Hz to 60 Hz -36 to 72 V DC optional DC P.S.


POWER CONSUMPTION

Desk-top, wall-mount, half rack, 19 in. shelf

Plug-in board: 5 W Desktop unit: 4.5 W maximum

IEEE802.3u S9 blade: 100Base-TX Desktop: 10/100Base-TX VLAN per port VLAN Tagging/Routing

www.alcatel-lucent.com
Alcatel, Lucent, Alcatel-Lucent and Alcatel-Lucent logo are trademarks of Alcatel-Lucent. All other trademarks are the property of their respective owners. The information presented is subject to change without notice. Alcatel-Lucent assumes no responsibility for inaccuracies contained herein. 2007 Alcatel-Lucent. All rights reserved. 21578 (03)