Sei sulla pagina 1di 1

B1

W:308
R:2215
U:-143
B2
W:308
R:2215
U:-143
0-4-3
7-10-3
0-4-3
8-3-15
1-0-0 1-0-0
225#
12-0-0
225#
18-0-0
30-0-0
15-0-0 15-0-0
1 2 3 4 5 6 7
8 9 10 11 12 13
6.00 -6.00
3-10
1.5-4
3-4
R4-4
3-4
1.5-4
3-10
3-4 4-6 S=5-6
3-4
SHIP
Cust : Tr uss Company
WO: Dr i ve_Y_sampl e_L00005_J 00001
Dsgnr : #LC = 51 WT: 176#
TC Li ve 40. 00 psf
TC Dead 10. 00 psf
BC Li ve 0. 00 psf
BC Dead 10. 00 psf
TOTAL 60. 00 psf
Dur Facs L=1. 15 P=1. 15
Rep Mbr Bnd 1. 00
Rep Mbr Comp 1. 00
Rep Mbr Tens 1. 00
O. C. Spaci ng 2- 0- 0
Desi gn Spec I BC
DEFL RATI O: L/ 240 TC: L/ 240
TRUSPLUS 6. 0 VER: T6. 4. 28
Job Name: Truss Sample Truss ID: ROOF Qty: 1
WARNINGRead all notes on this sheet and give a copy of it to the Erecting Contractor.
This design is for an individual building component not truss system. It has been based on specifications provided by the component manufacturer
and done in accordance with the current versions of TPI and AFPA design standards. No responsibility is assumed for dimensional accuracy. Dimensions
are to be verified by the component manufacturer and/or building designer prior to fabrication. The building designer must ascertain that the loads
utilized on this design meet or exceed the loading imposed by the local building code and the particular application. The design assumes that the top chord
is laterally braced by the roof or floor sheathing and the bottom chord is laterally braced by a rigid sheathing material directly attached, unless otherwise
noted. Bracing shown is for lateral support of components members only to reduce buckling length. This component shall not be placed in any
environment that will cause the moisture content of the wood to exceed 19%and/or cause connector plate corrosion. Fabricate, handle, install
and brace this truss in accordance with the following standards: 'Joint and Cutting Detail Reports' available as output from Truswal software,
'ANSI/TPI 1', 'WTCA 1' - Wood Truss Council of America Standard Design Responsibilities, 'BUILDINGCOMPONENT SAFETY INFORMATION' -
(BCSI 1-03) and 'BCSI SUMMARY SHEETS' by WTCA and TPI. The Truss Plate Institute (TPI) is located at 583 D'Onofrio Drive, Madison,
Wisconsin 53719. The American Forest and Paper Association (AFPA) is located at 1111 19th Street, NW, Ste 800, Washington, DC 20036.
TRUSWAL
SYSTEMS
1101 N. Great S.W. Pkwy., Arlington TX 76011
BRG X- LOC REACT SI ZE REQ' D
1 0- 1- 12 2215 3. 50" 3. 47"
2 29- 10- 4 2215 3. 50" 3. 47"
BRG REQUI REMENTS shown ar e based ONLY
on t he t r uss mat er i al at each bear i ng
TC 2x4 SPF C1650F1. 5E
BC 2x6 SPF C1650F1. 5E
WEB 2x4 SPF #3- CAN
2x4 SPF #1/ #2- CAN 10- 4
Lumber shear al l owabl es ar e per NDS.
Web br aci ng r equi r ed at each l ocat i on shown.
See st andar d det ai l s ( TX01087001- 001 r ev1) .
Pl at i ng spec : ANSI / TPI - 1995
THI S DESI GN I S THE COMPOSI TE RESULT OF
MULTI PLE LOAD CASES.
I RC/ I BC t r uss pl at e val ues ar e based on
t est i ng and appr oval as r equi r ed by I BC 1703
and ANSI / TPI and ar e r epor t ed i n avai l abl e
document s such as I CBO #1607.
Loaded f or 10 PSF non- concur r ent BCLL.
Loaded f or 200 l b non- concur r ent movi ng BCLL
ASCE7- 98 SNOWLOAD DESI GN CRI TERI A:
Pg = 50 psf , Ce = 1. 0, I = 1. 0, Ct = 1. 00
Per manent br aci ng i s r equi r ed ( by ot her s) t o
pr event r ot at i on/ t oppl i ng. See BCSI 1- 03
and ANSI / TPI 1.
UPLI FT REACTI ON( S) :
Suppor t Mai n Wi nd Non- Wi nd
1 - 143 l b
2 - 143 l b
Thi s t r uss i s desi gned usi ng t he
ASCE7- 98 Wi nd Speci f i cat i on
Bl dg Encl osed = Yes, I mpor t ance Fact or = 1. 15
Tr uss Locat i on = Not End Zone
Hur r i cane/ Ocean Li ne = No , Exp Cat egor y = B
Bl dg Lengt h = 34. 00 f t , Bl dg Wi dt h = 14. 50 f t
Mean r oof hei ght = 19. 92 f t , mph = 90
TPI Speci al Occupancy, Dead Load = 10. 0 psf
Desi gned as Mai n Wi nd For ce Resi st i ng Syst em
and Component s and Cl addi ng
Tr i but ar y Ar ea = 72 sqf t
- - - - - - - - - - LOAD CASE #1 DESI GN LOADS - - - - - - - - - - - - - - - -
Di r L. Pl f L. Loc R. Pl f R. Loc LL/ TL
TC Ver t 120. 00 - 1- 0- 0 120. 00 0- 0- 0 0. 67
TC Ver t 100. 00 0- 0- 0 100. 00 30- 0- 0 0. 80
TC Ver t 120. 00 30- 0- 0 120. 00 31- 0- 0 0. 67
BC Ver t 20. 00 0- 0- 0 20. 00 30- 0- 0 0. 00
. . . Type. . . l bs X. Loc LL/ TL
TC Ver t 60. 0 - 1- 0- 0 1. 00
TC Ver t 60. 0 31- 0- 0 1. 00
BC Ver t 225. 0 12- 0- 0 0. 67
BC Ver t 225. 0 18- 0- 0 0. 67
Truswal Systems connector plates are 20 ga. unless shown by "18" (18 ga.), "H" (16 ga.), or "MX" (high strength 20 ga.), positioned
per Joint Detail Reports available from Truswal software. Circled plates and false frame plates are positioned as shown above.
MAX DEFLECTI ON ( span) :
L/ 999 I N MEM 10- 11 ( LI VE)
L= - 0. 22" D= - 0. 11" T= - 0. 33"
CRI TI CAL MEMBER FORCES:
TC COMP. ( DUR. ) / TENS. ( DUR. ) CSI
1- 2 - 3864( 1. 15) / 155( 1. 60) 0. 62
2- 3 - 3532( 1. 15) / 137( 1. 60) 0. 61
3- 4 - 2568( 1. 15) / 137( 1. 60) 0. 56
4- 5 - 2568( 1. 15) / 137( 1. 60) 0. 56
5- 6 - 3532( 1. 15) / 137( 1. 60) 0. 61
6- 7 - 3865( 1. 15) / 154( 1. 60) 0. 62
BC COMP. ( DUR. ) / TENS. ( DUR. ) CSI
8- 9 - 80( 1. 60) / 3372( 1. 15) 0. 53
9- 10 - 13( 1. 60) / 2795( 1. 15) 0. 58
10- 11 - 13( 1. 60) / 2795( 1. 15) 0. 58
11- 12 - 13( 1. 60) / 2795( 1. 15) 0. 39
12- 13 - 80( 1. 60) / 3372( 1. 15) 0. 53
WB COMP. ( DUR. ) / TENS. ( DUR. ) CSI
2- 9 - 572( 1. 15) / 132( 1. 60) 0. 19
3- 9 / 750( 1. 15) 0. 33
3- 10 - 1077( 1. 15) / 128( 1. 60) 0. 86
4- 10 / 1739( 1. 15) 0. 43
5- 10 - 1077( 1. 15) / 127( 1. 60) 0. 86
5- 12 / 750( 1. 15) 0. 33
6- 12 - 572( 1. 15) / 132( 1. 60) 0. 19
B
C
D
E
F
G
H
I
M
L
A
L
D
C
K
D
F
I
J
D
D
D
SEAL
Depth and span dimensions
(feet-inch-16ths)
Chord pitch, if applicable,
(inches per foot)
Bearing information and width
requirements
Applicable design loads
Adjustment factors to lumber and metal
connector plates, spacing, and design
specification
Bearing reaction force (pounds)
Metal connector plate types & sizes
Lumber size, specie, and grade for
each member
Combined stress index for webs and
chords
Maximum compression and tension
forces for webs and chords (pounds)
Calculated LL deflection ratio and
deflection magnitudes (inches)
Required truss member bracing
location
Important general notes and design
assumptions
A
B
C
D
E
F
G
H
I
J
K
L
M
ROOF TRUSS SAMPLE DESIGN
M
G

Potrebbero piacerti anche