Sei sulla pagina 1di 77

SECTION I STANDARD DETAILS INDEX

Title Water Distribution System Typical Plan Typical Street Cross Section and Street Centerline Profile Water Distribution System Typical Plan for Curved Streets Water Distribution System Typical Plan for Cul-de-Sacs Fire Hydrants, Location and Installation Locator Wire Detail Piping at Street Intersection - Future Connections Typical Trench Section - Pipe Protection Blow-Off Installation for Twelve-Inch (12) and Smaller Pipes Low Point Blow-Off/Sand Trap Transmission Main Blow-Off Installation Valve Box Support Plate and Extension Guide Air and Vacuum Valve Installation Access Manhole Assembly Transmission Main Butterfly Valve Assembly 24" and 30" Butterfly Valve Installation Concrete Kickblocks - Bearing Surface and Installation Length of Tied Pipe Tie Rod and Washer Details Tie Rod Coupling Flange Lug Detail Pipe Bedding Clamp Details and Dimensions Harness Lug Details Bored Crossings Beneath Conduits Bore Casing Detail Conduit or Storm Sewer Crossing Crossing Storm and Sanitary Sewers Bedding Details Typical Cutoff Wall Three-Inch (3") and Larger Domestic and Sprinkler Connections Insulate Joints, Rods and Mechanical Couplings Polyethylene Wrap Valve Box Detail Title

SHEET 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 Page

Adjustable Steel Pipe Valve Support Vent Pipe - Installation and Details Six-Inch (6") Diameter Vent Pipe Screen Residential Vent Assembly Pressure Regulating Valve - Manhole Installation Typical Plan Pressure Regulating Valve - Manhole Installation Cross Section Pressure Regulating Valve - Rectangular Vault Typical Plan Pressure Regulating Valve - Rectangular Vault Cross Section Inside Commercial Meter Installation for Twelve-Inch (12") & Smaller Pipe Service Line, Stop Box and Outside Meter Installation Outside Setting for 5/8" x 3/4", 3/4" and 1 Meters with PRV Remote Reading 3/4" and 1" Meter - Typical Inside Setting Service Line, Stop Box and Inside Meter Setting Remote Reading Water Lead Installation Details Outside Setting for 1-1/2" and 2" Meter for Irrigation Rural Curb Stop Inside Setting for 1-1/2" and 2" Meter with Check Valve Wall and Body Clamps for 3" Meters Wall Clamps for 4", 6", 8" and 10" Meters Compound Meter with Check Valve and Bypass Compound Meter with Check Valve and Bypass (continued) F.M. - C.T. Meter with Bypass F.M. - C.T. Meter with Bypass (continued) Marker Post Detail Stub-Out Configurations Stub-Out Configurations Valve Operations Outside Setting for 1-1/2" and 2" Meter - Brass Alternative Turbine Meter with Check Valve and Bypass Turbine Meter with Check Valve and Bypass (continued) Mechanical Joint Restraint Typical Water Services District Policies and Installation Notes for Water Services Pressure Vacuum Breaker Meter/Remote Locations Water Encasement Valve Operator Extension Combination Fire/Service Tap Residential Fire Line Irrigation Meter 3 and Larger 24 Diameter Ring and Cover

35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75

Potrebbero piacerti anche