Sei sulla pagina 1di 49

RHOSS APPLIED SYSTEM Catalogue 2010

Sales Meeting, April 2010

A complete and wide range divided in:


Chiller&heat pump Product Sheet Up to 1600 kW (air and water cooled units)

RHOSS SEQUENCER

Product Sheet

Chiller & heat pump Up to 64 kW (air and water cooled units)

Product Sheet

Terminal Units Fan coils


Sales Meeting, April 2010

Product Sheet

CHILLER & HEAT PUMP RANGE: Air cooled Cooling Capacity up to 64 kW


TCAEY Mini-Y range Mod. 105111 THAEY Mini-Y NF range Product Sheet TCAEY-THAEY Compact-Y Range Mod. 115238
Product Sheet

11,9 11,1 41,7 38,8 31,7 27,8 68,0 64,0 27,0 24,0 54,3 48,5

TCAEY-THAEY radiant panel version

Mod. 118136 H.E.


Product Sheet

TCAEY-THAEY Compact-Y Range Mod. 245265


Product Sheet

TCAIY-THAIY Y-MICH Range TCAI-THAI M.I.C.H Range

Mod. 124
Product Sheet

Mod. 150
Product Sheet

5
Sales Meeting, April 2010

15

25

35

45

55

65

75 kW

Cooling capacity (kW)

Heating capacity (kW)

And water cooled

CHILLER & HEAT PUMP RANGE : Air cooled Chiller from 5 up to 11 kW MINI-Y Range: TCAEY/THAEY NF 105111
Plug & Play units available in 4 size up to 11 kW in cooling mode and up to 12 kW in heating mode (NF certified version) Available with Pump or Tank & Pump. Refrigerant R410A Axial Fan for outdoor installation centrifugal fan for indoor installation Single scroll compressor with internal motor protection Condenser: coil in copper pipe and aluminum fins or microchanell aluminium fins Evaporator: stainless steel plate heat exchanger. Electronic microprocessor control available in 2 options, Basic with Adaptive Function and iDRHOSS system compatible with AdaptiveFunction Plus Wide operating limits: suitable for radial panel and down to -15 C of air for Heat pump NF version
Sales Meeting, April 2010

CHILLER & HEAT PUMP RANGE : Air cooled Chiller from 15 up to 34 kW COMPACT-Y Range: TCAEY/THAEY 115238
Plug & Play units available in 9 size up to 39 kW in cooling mode and up to 42 kW in heating mode. Available with Pump or Tank & Pump (also without pumping group for models 133-233). Desuperheater or total heating recovery as option (mod.133-238) Axial Fans for outdoor installation with low noise emissions. Silenced configuration available. Single scroll compressor with internal motor protection (double comp. for the mod.233-238) Condenser: coil in copper pipe and aluminum fins Evaporator: stainless steel plate heat exchanger. Electronic microprocessor control available in 2 options, Basic with Adaptive Function and iDRHOSS system compatible with AdaptiveFunction Plus (LWT control) Units with Centrifugal fans for indoor installation in R407C (up to 22kW in cooling mode)
Sales Meeting, April 2010

CHILLER & HEAT PUMP RANGE : Air cooled Chiller from 18 up to 37 kW COMPACT-Y Range: TCAEY/THAEY 118136 H.E. High efficiency Plug & Play units developed also for
radiant panel applications Available in 6 sizes up to 40,5 kW in cooling mode and up to 33,5 kW in heating mode (conditions for radiant panel application: summer: air 35 C water 18/23, wi nter: air 7 C water 35/30 C) Available with Pump or Tank & Pump (also with hydraulic by-pass as separator for primary and secondary circuit). Axial Fans with condensation control as standard, single scroll compressor with internal motor protection. Available silenced configuration. Condenser: coil in copper pipe and aluminum fins Evaporator: stainless steel plate heat exchanger. Electronic microprocessor control iDRHOSS system compatible with AdaptiveFunctionPlus (LWT control) Operation limits down to -10 C with production of h ot water up to 40 C (winter mode) COP > 3,93 ESEER with AF+ up to 3,9
Sales Meeting, April 2010

CHILLER & HEAT PUMP RANGE : Air cooled Chiller from 40 up to 64 kW COMPACT-Y Range: TCAEY/THAEY 245265
Plug & Play double compressor units available in 4 sizes up to 64 kW in cooling mode and up to 68 kW in heating mode.

Double scroll compressors with internal motor protection and 1 circuit with 3 capacity steps => high efficiency at part load operation
DS or total heating recovery as option Axial Fans for outdoor installation complete with condensation control. Available silenced configuration. Condenser: coil in copper pipe and aluminum fins Evaporator: stainless steel plate heat exchanger. Electronic microprocessor control iDRHOSS system compatible with AdaptiveFunction Plus (LWT control)

Sales Meeting, April 2010

CHILLER & HEAT PUMP RANGE : VFD Scroll compressor chiller Y-Mich Range: TCAIY/THAIY 124
Air cooled water chiller and heat pump unit, 24 kW at nominal condition Inverter driven Scroll compressor Electronic expansion valve Advanced electronic microprocessor with control on LWT Plug & Play unit with packaged hydronic components Continuous modulation of cooling and heating capacity (100% down to 30%) No need of power-factor corrections capacitor Extremely low starting current

Sales Meeting, April 2010

CHILLER & HEAT PUMP RANGE : VFD Scroll compressor chiller Mich Range: TCAI/THAI 150
Air cooled water chiller and heat pump unit, 50 kW at nominal condition Inverter driven Scroll compressor Electronic expansion valve Advanced electronic microprocessor with control on LWT Plug & Play unit with packaged hydronic components Continuous modulation of cooling and heating capacity (100% down to 30%) Energy saving up to 20% compared with the standard system No need of power-factor corrections capacitor Extremely low starting current

Sales Meeting, April 2010

EXP SYSTEM RANGE:

PICTURES

Polyvalent units available in different capacity to satisfy different applications Air cooled units from 17 up to 680 kW in cooling mode Water cooled unit from up to 850 kW for residential application Thanks to the EXP technology is possible to have free-heating also to produce hot sanitary water independently from the production of chilled water EXP satisfy the request of 2-4 pipe system with only one unit

Sales Meeting, April 2010

EXP SYSTEM RANGE:

Sales Meeting, April 2010

Water cooled Chiller up to 42 kW

45,0

TCHEY-THHEY Y-Flow Range

Mod. 115240
Product Sheet

42,0

13,9

TCHEY-THHEY Comby-Flow Range

Mod. 105112
Product Sheet

12,0

15

25

35

45

kW

55

Cooling capacity (kW)

Heating capacity (kW)

Sales Meeting, April 2010

CHILLER & HEAT PUMP RANGE : Water cooled Chiller from 5 up to 12 kW Y-FLOW Range: TCHEY/THHEY 105-112
4 models from 5 to 12 kW in cooling and from 6,5 to 14 kW in heating Available as chiller and heat pump complete with pump or pump & external tank Compact dimensions Low electrical absorption All range EER >3,20 Equipment suitable for various applications: RESIDENTIAL AIR CONDITIONING/HEATING RADIANT PANELS GEOTHERMAL APPLICATION Application with CITY WATER Wide operating limits Available TXHEY EXP Polyvalent unit
Sales Meeting, April 2010

CHILLER & HEAT PUMP RANGE : Water cooled Chiller from 14 up to 42 kW Y-FLOW Range: TCHEY/THHEY 115-240
6 models from 14 to 42 kW in cooling and from 17 to 45 kW in heating. A class for radiant applications Single scroll compressor with internal motor protection Stainless steel plate exchanger complete with differential pressure switch Refrigerant R410A application with city water or geothermal probes Many accessories available like Pumps, silenced configuration, pressure switch valve, external air temperature probe, freecooling kit, Condenserless version (TCEE) is also disposal
Sales Meeting, April 2010

CHILLER & HEAT PUMP RANGE : up to 1600 kW


TCAE-THAE Y-Pack Range

Mod. 2702160
Product Sheet Product Sheet

175,0 161,0 342,0 325,0 361,0 486,2 455,1 389,0 693,2 665,9 700,0 680,0 1283,4 1602,0 77,1 66,3

Mod. 41604320
TFAE-TGAE Mod. Y-Pack Freecooling TCAEY-THAEY Mod. Y-Power Range TCAVZ Z-Power Range

41604320 Product Sheet 53506450 Product Sheet


Product Sheet

Mod. 12701390
Product Sheet

Mod. 23302700 H.E. Mod. 23102670


THAVZ Heat pump Z-Power Range

Mod. 24002680 Product Sheet


Product Sheet

Mod. 277021290 H.E. Mod. 271021600


TCCE-THCE

Mod. 130270
Product Sheet

50 Water cooled
Sales Meeting, April 2010

250

450

650

850

1050

1250

1450

And water cooled

kW

CHILLER & HEAT PUMP RANGE : Air cooled Chiller from 70 up to 161 kW Y-Pack Range: TCAEY/THAEY 2702160
High efficiency Plug & Play units Available in 4 versions: B - standard only chiller, T- high temperature/efficiency, S Silent, Q super silent only chiller Available in 8 sizes up to 161kW in cooling mode and up to 175 kW in heating mode Double scroll compressor with internal motor protection and 1 circuit with 3 capacity steps (according to the models) => high efficiency at part load operation EER up to 2,99 and COP up to 3,36. ESEER up to 4,37 Axial Fans with condensation control as standard (except B version), Hi-pressure prevent function (in case of high ambient temperature) Thanks to the software the water content will be reduced down to 2 L/kw Available with Pump or Tank & Pump De-superheater and total heat recovery available Electronic microprocessor control iDRHOSS system compatible with AdaptiveFunctionPlus (LWT control)
Sales Meeting, April 2010

CHILLER & HEAT PUMP RANGE : Air cooled Chiller from 150 up to 325 kW Y-Pack Range: TCAEY/THAEY 41604320
High efficiency Plug & Play units Available in 4 versions: B - standard only chiller, T- high temperature/efficiency, S Silent, Q super silent only chiller Version B with very compact dimensions also for replacement markets Available in 7 sizes up to 325kW in cooling mode and up to 342 kW in heating mode EER up to 2,87 and COP up to 3,03. ESEER up to 4,25 Hi-pressure prevent function (in case of high ambient temperature) Thanks to the software the water content will be reduced down to 2 L/kw Available with Pump or Tank & Pump De-superheater and total heat recovery available Electronic microprocessor control iDRHOSS system compatible with AdaptiveFunctionPlus (LWT control)

Sales Meeting, April 2010

CHILLER & HEAT PUMP RANGE : Air cooled Chiller in Freecooling mode Y-Pack Range: TFAEY-TGAEY 41604320
High efficiency frecooling chiller available in 2 versions: T- high efficiency, S Silent Unit G No GLYCOL available 7 sizes up to 361kW and EER up to 3,4 Thanks to the software the water content will be reduced down to 2 L/kw Available with single or double Pumps Electronic microprocessor control iDRHOSS system compatible with AdaptiveFunctionPlus (LWT control) Software for estimating energy saving

Sales Meeting, April 2010

CHILLER & HEAT PUMP RANGE : Air cooled Chiller from 70 up to 316 kW Q-Pack Range: TCAE/THAE 2704320
Units with scroll cprs for outdoor installation available in 15 sizes from 70 to 316 kW in cooling, from 77 to 360 kW in heating Models 270-2160: 2 scroll compressors, 2 circuits Models 4155-4320: 4 scroll compressors, 2 circuits (tandem execution) Units can be equipped with storage tank (up to 1100 l according to the size) and single or double pumps. De-superheater and total heat recovery available A well-design structure allows to have a standard unit with low sound level and completely independent circuits for also an intelligent defrosting management. Microprocessor electronic control with Adaptive Function
Sales Meeting, April 2010

CHILLER & HEAT PUMP RANGE : Air cooled Chiller from 330 up to 455 kW Y-Power Range: TCAEY/THAEY 53506450
Units with scroll cprs for outdoor installation available in 4 sizes from 330 to 455 kW in cooling, from 353 to 486 kW in heating Design, technology and components for R410A Models with 5/6 scroll compressors, 2 circuits and electronic expansion valve as standard Units can be equipped with storage tank (1100 l) and single or double pumps. De-superheater and total heat recovery available A well-design structure allows to have a standard unit with low sound level and completely independent circuits to have an intelligent defrosting management. New Microprocessor electronic control and leaving water temperature control
Sales Meeting, April 2010

CHILLER & HEAT PUMP RANGE : Air cooled Chiller from 270 up to 390 kW Z-Power Range: TCAVZ 12701390
Air cooled water chillers with axial fans for outdoor installation 4 models in cooling, from 270 to 390 kW 1 circuit, 1 twin-screw compressor Compressor available with step-less capacity control from 50% to 100% R134a refrigerant Available low-noise version Unit can also be equipped with pumps, Desuperheater, total heat recovery.

Sales Meeting, April 2010

CHILLER & HEAT PUMP RANGE : Air cooled Chiller from 300 up to 700 kW Z-Power Range: TCAVZ 23302700 H.E. TCAVZ 23102670
High efficiency Air cooled water chillers with axial fans for outdoor installation 13 models H.E. in cooling, from 320 to 700 Kw 13 models in S.E. in cooling, from 300 to 670 Kw EER > 3,1 (H.E.) Energy Class A, ESEER up to 4,18 2 circuits, 2 screw compressors and electronic expansion valve as standard Evaporator: Plate or Shell&Tube exchanger Available in low-noise version Operating limits from 48 C down to 5 C at full load (at part load up to 50 C) Down to -15 C with the condensation control Accessory: pump, T&P can be fitted
Sales Meeting, April 2010

CHILLER & HEAT PUMP RANGE : Heat pump from 400 up to 700 kW Z-Power Range: THAVZ 24002680
High efficiency Air cooled heat pump with axial fans for outdoor installation 5 models in cooling, from 400 to 680 Kw and from 426 up to 700 in heating. EER up to 3,0 2 circuits, 2 screw compressors and electronic expansion valve as standard Evaporator: Shell&Tube exchanger Available in low-noise version Operating limits from 48 C down to 5 C at full load (at part load up to 50 C) Down to -10 C with the condensation control

Sales Meeting, April 2010

CHILLER & HEAT PUMP RANGE : Air cooled Chiller from 710 up to 1600 kW Z-Power Range: TCAVZ 277021290 H.E. TCAVZ 271021600
High efficiency Air cooled water chillers with axial fans for outdoor installation 11 models H.E. in cooling, from 760 to 1290 Kw 14 models S.E. in cooling, from 710 to 1600 Kw EER > 3,2 (H.E. models) - IPLV > 4,4 2 circuits, 2 screw compressors and electronic expansion valve as standard Refrigerant R134a Available in low-noise version Operating limits from max 45 C to 5 C as standard at full load (at part load up to 50 C) Down to -15 C with the condensation control Accessory like pumps can be fitted
Sales Meeting, April 2010

CHILLER & HEAT PUMP RANGE Air cooled Chiller from 30 up to 70 kW TCCE/THCE 130270
Air cooled water chillers and heat pumps with centrifugal fans for indoor installation 6 models from 30 to 66 kW in cooling, from 35 to 77 kW in heating Available with built-in hydronic kit Single scroll compressor up to 60 kW Model 270 available with double scroll compressors and single circuit Available with high Static Pressure Fans (maximum E.S.P. from 275 to 320 Pa)

Sales Meeting, April 2010

CHILLER & HEAT PUMP RANGE : Water cooled chiller up to 1600 kW


TCHE-THHE Y-Flow Range
Mod. 2454450
Product Sheet

513,0 450,0

TCHVZ HE Z-Flow Range Mod. 120131631


Product Sheet

1635,0

TCHVZ-TCEVZ Z-Flow Range Mod. 120031630


Product Sheet

1629,3

100

500

900

1300

kW

Cooling capacity (kW)

Heating capacity (kW)

Sales Meeting, April 2010

CHILLER & HEAT PUMP RANGE : Water cooled Chiller from 40 up to 450 kW Y-Flow Range: TCHE/THHE 2454450
Water cooled water chiller for indoor installation in A class (radiant application) 12 Models: Cooling capacity from 40 kW to 450 kW and heating capacity from 50 kW to 512 kW Many Accessories available like pumps, desuperheater, total heat recovery, soft start, EEV, silenced configuration, .. application with city water or geothermal probes

Available in condenserless version (R407C) and It can be combined with external Hydraulic kit (PBHI) complete with storage tank and single or double pump. Standard or with free-cooling version.

Sales Meeting, April 2010

CHILLER & HEAT PUMP RANGE :


Water cooled Chiller from 200 up to 1630 kW

Z-Flow Range: TCHVZ 120131631 HE


High efficiency Water cooled water chillers from 200 to 1635 kW (33 units) EER > 5,05 - ESSER > 5,7 Refrigerant R134a Electronic expansion valve as standard Latest generation of screw compressors optimized for water cooled units (available even with step-less control 25%-100%) Latest generation of evaporator single refrigerant pass Advanced electronic microprocessor control (allows even double or adjustable set-points) Compact dimensions. Standard and Sound-proofed Version available

Sales Meeting, April 2010

CHILLER & HEAT PUMP RANGE : Water cooled Chiller from 200 up to 1630 kW Z-Flow Range: TCHVZ 120031630
Water cooled water chillers from 200 to 1630 kW (33 units) EER > 4,75 - ESSER > 5,7 Refrigerant R134a Electronic expansion valve as standard Latest generation of screw compressor (available even with step-less control 25%100%) Latest generation of evaporator single refrigerant pass Advanced electronic microprocessor control (allows even double or adjustable set-points) Compact dimensions. Versions Standard, Sound-proofed and condenserless unit
Sales Meeting, April 2010

CHILLER & HEAT PUMP RANGE : RHOSS SEQUENCER

Sales Meeting, April 2010

TERMINAL UNITS RANGE


Brio Ev 100/1388 m3/h
Product Sheet Product Sheet

Yardy Ev 100/1480 m3/h VTNC 416/1720 m3/h


Product Sheet

Product Sheet

Idrowall 310/825 m3/h


Product Sheet

UTNCUTNC -Ev 360/1685 m3/h


Product Sheet

UTNA 1060/16500 m3/h DUCT&DUCT HP


Product Sheet

UTNB 850/1680 m3/h

UTNV 3000/15600 m3/h


Sales Meeting, April 2010

UTNR 925/4000 m3/h


Product Sheet

TERMINAL UNITS RANGE : IDROWALL


Cooling capacity (1,9-3,9 kW) Heating capacity (2,5-5,4kW)

4 models with cooling capacity from 2 up to 4 kW Eurovent certified New range with display Reduced wall mounted dimensions On board 3-way valve

Sales Meeting, April 2010

TERMINAL UNITS RANGE : FLOOR AND CEILING Installation FANCOILS


Cooling capacity (1,1-7,2 kW) Heating capacity (2,4-17,4kW) 10 models with cooling capacity from 1 up to 7,2 kW Eurovent certified Low sound level More Accessories factory fitted like:
o o o o

electronic controls, additional heating coil, electrical heater Electrovalves YARDY with Cabinet YardyEV recessed/ductable

Sales Meeting, April 2010

TERMINAL UNITS RANGE : Yardy-Ev with cabinet


Versions with cabinet
MVP - MVT - MOP - MOT

Accessories factory fitted:


electronic controls, additional heating coil, electrical heater electrovalves

Sales Meeting, April 2010

TERMINAL UNITS RANGE : Yardy-Ev recessed/ductable


Versions recessed/ductable
IVP IVF IOP

Accessories factory fitted:


electronic controls, additional heating coil, electrical heater electrovalves

Sales Meeting, April 2010

TERMINAL UNITS RANGE : Yardy DUCT& DUCT HP

Yardy DUCT: 4 models with cooling capacity from 2 up to 5,1kw and 6 selectable speeds DUCT HP: 5 models with cooling capacity from 7 up to 15 kw and max 60Kpa at max speed. More Accessories factory fitted like: electronic controls, additional heating coil, electrical heater and Electrovalves

Sales Meeting, April 2010

TERMINAL UNITS RANGE : FLOOR AND CEILING Installation FANCOILS


Cooling capacity (1-6,9 kW) Heating capacity (1,3-16,5kW)
10 models with cooling capacity from 1 up to 7 kW Eurovent certified Low sound level More Accessories factory fitted like:
o o o o

electronic controls, additional heating coil, electrical heater electrovalves Features: adjustable fins Features: infrared remote control Features: Colour BRIO EV with cabinet Access panel with screw and safety grille Easy installation

Sales Meeting, April 2010

TERMINAL UNITS RANGE : Brio-Ev: adjustable fins

40

Sales Meeting, April 2010

TERMINAL UNITS RANGE : Brio-Ev: infrared remote control and recessed control panel

Sales Meeting, April 2010

TERMINAL UNITS RANGE : Brio-EV: colour range Standard colour

MONO colour BI colour

Sales Meeting, April 2010

TERMINAL UNITS RANGE : Brio-Ev with cabinet


Versions with cabinet
MVP MVT MOP MOT

Accessories factory fitted:


electronic controls, additional heating coil, electrical heater electrovalves

Sales Meeting, April 2010

TERMINAL UNITS RANGE : Brio-Ev Technical features


Access panel locking screw and safety grill on the fancoil side with electrical connection

Sales Meeting, April 2010

TERMINAL UNITS RANGE : Brio-Ev Installation features


Electrical connection
o MVP MVT version Rapid connector for Rhoss control panel o Other versions Electrical terminal for the connection to the control panels o New easy filter maintenance

o New electrovalves ON/OFF

Sales Meeting, April 2010

TERMINAL UNITS RANGE : Integrated solution for the air-conditioning plant

Hydronic advanced solutions for integrated comfort control

Sales Meeting, April 2010

AIR HANDLING UNITS: CTA ADV from 800 m3/h to 90000 m3/h
55 AHU sizes Air flow capacity from 800 m3/h to 90000 m3/h Designed for several applications (such as Civil, commercial, hotel, pharmaceutical, hospital, applications in a saline environment) Easily selected through our own AHU Software Some features: Heat block and radiated profile also available Panel thickness 25,42,46 and 63 mm in different finishing Different type of filter and efficiency Standard coil in copper and aluminium fins. Available also pre-painted and copper/copper Available with all regulations!!! Plug & play AHU (Italian market)

Sales Meeting, April 2010

DEHUMIDIFIER RANGE: DRESY DAESY Dry-pool ADV


17 sizes Air flow rate from 2.200 up to 22.000 m3/h Dehumidification capacity from 8 up to 111 l/h Different fan available static pressure (from 100 up to 200 Pa) Version without (DAESY), with partial (DRESY) or total (DTESY) water side heat recovery Modules of air side free-cooling (DAFC) or crossed flow heat recovery (DAHR) Factory fitted accessory like hot ware coil (BA) or electric heating coil (BE)

Sales Meeting, April 2010

TERMINAL UNITS RANGE: UTNC-EV - Hydronic Cassette


Cooling capacity (2-10 kW) Heating capacity (5-24 kW)
Versions for:
o o o

2 pipes systems, 4 pipes system, 2 pipes systems with electrical heater

3 models (2,4-4,0-4,7 kWf) size 60x60 cm 3 models (6,3-7,6-10,0 kWf) size 80x80 cm very low sound levels condensate pump with high E.S.P. Accessories like:
o o o

electrovalves electronic controls and remote control electrostatic filter

Sales Meeting, April 2010

TERMINAL UNITS RANGE: VTNC - Hydronic Cassette


Cooling capacity (2-8 kW) Heating capacity (5-20 kW)

Versions for:
o

2 pipes systems,

3 models (2,5-3,1-4,8 kWf) size 60x60 cm 2 models (5,8-7,8 kWf) size 80x80 cm very low sound levels condensate pump with high E.S.P. Accessories like:
o o

electrovalves 3 vay electronic controls and remote control

Sales Meeting, April 2010

TERMINAL UNITS RANGE: UTNR- Fresh air unit with heat recovery
Heat recovery capacity (5 -18 kW)
5 models Horizontal installation and plenum for vertical installation

Sandwich panels with a total thickness of 25 mm, in double galvanised sheet steel, hot-injected polyurethane insulation Air-air type heat recovery with aluminium pack Additional water heating coil Synthetic or metallic filters for air
Sales Meeting, April 2010

Potrebbero piacerti anche