Feature Comparaison Chart 38DL PLUS vs.

GE DMS Go
Confidential information for internal use only
Features Battery life Can See full waveform while calibrating Thickness, Velocity and Time of Flight modes Digital Filters High Resolution up to 0.0001" (0.001 mm) Automatic Probe Recognition (dual element) Gain optimization during calibration Calibration doubling warning Ability to adjust Gain and Blanks on Frozen waveforms Thru Coat Auto Echo-to-Echo 3 Color DB Grid V-Path Builder; create and store custom V-Path table for dual element transducers Compatible with EMAT transducers Min/Average Mode (up to 4 readings) Bi-directional RS-232 VGA output Stored setup locations for Single Element transducers Stored setup locations for Dual Element transducers Internal and removable Memory (Micro-SD Memory Card) Internal Oxide Software 35 10 38DL PLUS 12-14 hours DMS Go They claim 8-10 but it is more like 8 hours No No No No No No No No No No No No No No No No 16 total 16 total No, Removable Only The manual states it has the Oxide Software, however I could not make it work No No No No 16 Yes, but Freeze is activated in a menu No there is no Zoom feature on the DMS Go Yes, but the Peak is always AGCd to 4 db above gate Removable Only Yes, but it requires adjusting two gates No, you have to set Save Thickness and Save Thickness & AScan in a menu. It is difficult to save only a

Optional

High penetration software for low frequency single element transducers Multi-layer Software for up to four layers High resolution single element software Encoded B-Scan File name length (Max # characters) Freeze Mode Zoom with echo tracking

Optional Optional Optional Optional 32

Gain Adjust Internal and removable Memory (Micro-SD Memory Card) Manual Echo-to-Echo

Quick save waveform at only a few ID# locations

Page 1 of 2

Features

38DL PLUS

B-Scan Extended Blank Top Coat with Auto Velocity Color VGA transflective display Temperature Compensation Fast Measurement Rate of 30 per second Min/Max Mode Capture both Min and Max Auto Zero Compensation Mode Display Hold/Blank Inches/Millimeters Mode Live A-scan with waveform adjust Differential Mode Reduction Rate Differential Mode Hi-Low Alarm Programmable Instrument Lock with password Alphanumeric Internal Datalogger DB Grid Maximum # of stored thickness readings

No

DMS Go few waveforms Yes, but it is very limited compared to the 38DLP No, you need to adjust the gate start Yes, but the transducer is expensive (Wide VGA) 16Hz & 32Hz (Only in scanning modes)

Maximum # of stored waveforms

ID# length (Max # Characters) Comments/Notes for each saved ID# Save Comments for a range of ID#s Bi-directional USB communication Field swap data via Micro SD card Export format to SD card IP67 Environmentally sealed Notes * B-scan allows the user to save a single screen or up to 10,000 readings. B-Scans can be reviewed in GageView

475,000 on internal 2 GB card and another 475,000 on the external SD Card 20,000 on internal 2 GB card and another 20,000 on external SD Card 20

Much greater because you can use a 16 GB SD Card Much greater because you can use a 16 GB SD Card 20

Survey, Txt & CSV

Not sure CSV, XML, .DAT & PDF

Page 2 of 2