Documenti di Didattica
Documenti di Professioni
Documenti di Cultura
Shut-off valves with threads, PN 10 / PN 16, with manual override in open and closed cold and warm water systems for switching heating and cooling machines on and off
A6..HL / A6..SL
Overview of types
Type 1) A650HL A665HL A680HL A6100HL A6125HL A6150HL A6125SL A6150SL A6200SL A6250SL A6300SL A6350SL DN [mm] 50 65 80 100 125 150 125 150 200 250 300 350 kvmax 2) [m3/h] 90 180 300 580 820 1600 820 1600 2900 4400 7300 10900 Zeta value 1.23 0.88 0.73 0.47 0.58 0.32 0.58 0.32 0.3 0.32 0.24 0.2 Manual override with lever with lever with lever with lever with lever with lever with worm gear 3) with worm gear 3) with worm gear 3) with worm gear 3) with worm gear 3) with worm gear 3)
. . . . .
1) Other types on request 2) According to VDI 2176 3) Unsuitable for outdoor applications
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Technical data
Functional data Media Medium temperature Authorised pressure ps Flow rate kvmax Leakage rate Pipe connectors DN 50 ... DN 150 DN 200 ... DN 350 Suitable connecting flanges Cold and warm water, Water with max 50% volume of glycol 20C ... +120C 1600 kPa See Overview of types A, tight (EN 12266-1) Flange PN 10 / PN 16 (according to ISO 7005-2) Flange PN16 (according to ISO 7005-2) According to ISO 7005-2 and EN 1092-2
. . .
www.belimo.com
/4
A6..HL / A6..SL
Technical data
Functional data
Materials
See Dimensions and weights on page 3 (with lever) and 4 (with worm gear)
Safety notes
This shut-off valve has been designed for use in stationary heating, ventilation and air conditioning systems and is not allowed to be used outside the specified field of application, especially in aircraft or in any other airborne means of transport. It may only be installed by suitably trained personnel. Any legal regulations or regulations issued by authorities must be observed during assembly. The shut-off valve does not contain any parts that can be replaced or repaired by the user. The shut-off valve may not be disposed of as household refuse. All locally valid regulations and requirements must be observed. When determining the flow rate characteristic of controlled devices, the recognised directives must be observed. In order to avoid water hammers in the piping system, the disc is to be opened and closed slowly.
Product features
Mode of operation
The valve cone made of stainless steel is pressed into the soft-sealing EPDM seat by a manual rotary movement and ensures leakage rate A (tight). The pressure losses are slight in the open position and the kv value is at a maximum. With lever (DN 25 ... 150): Adjustable in 10 ratchet steps with position indication (0 = 0 ; 9 = 90 ). With worm gear (DN 125 ... 350): Steplessly adjustable (self-locking) with position indication.
Manual override
Installation notes
Recommended installation positions
The shut-off valves may be mounted either vertically or horizontally. The shut-off valves may not be installed in a hanging position i.e. with the stem pointing downwards.
90
90
The water quality requirements specified in VDI 2035 must be adhered to. Shut-off valves, lever and worm gear are maintenance-free. In the event of any service work being done on the actuator, any pumps in the part of the piping system concerned must also be switched off and the appropriate isolating fittings closed (allow everything to cool down first if necessary and reduce the pressure in the system to ambient pressure levels). The system must not be returned to service until the shut-off valve has been properly reassembled in accordance with the instructions and the pipeline has been refilled in the proper manner.
/4
www.belimo.com
A6..HL / A6..SL
Dimensions [mm]
Dimensional drawings
H3
H4 H2
H5
H6
DB
H1
B1
CLOSE
PN 10 / PN 16 K d [mm] [mm] 125 4 x M16 145 4 x M16 160 8 x M16 180 8 x M16 210 8 x M16 240 8 x M20 H3 [mm] 64 64 64 64 78 78 H4 [mm] 197 211 222 234 272 280 B1 [mm] 43 46 46 52 56 56
Weight [kg] 2.8 3.3 4.6 5.3 7.6 9.2 B2 [mm] 25 25 25 25 28 28 L [mm] 175 175 175 175 263 263 DB [mm] 52 64 78 103 122 155
www.belimo.com
876
32
OPEN
B2
/4
A6..HL / A6..SL
Dimensions [mm]
Dimensional drawings
H3
H4
H2
H7
H5
H6
DB
H1
T1
T2
CLOSE
OPEN
L1 L2
DN [mm] 125 150 200 250 300 350 DN [mm] 125 150 200 250 300 350
PN 16 K [mm] d [mm] Weight [kg] 17.7 19.3 24.7 34.3 45.1 56.1 L2 [mm] 306 306 306 306 308 308 T1 [mm] 172 172 172 172 192 192 T2 [mm] 98 98 98 98 113 113 T3 [mm] 206 206 206 206 223 223 DB [mm] 122 155 202 250 301 333
12 x M20 12 x M24 12 x M24 16 x M24 L1 [mm] 150 150 150 150 160 160
Further documentation
Overview Valve-actuator combinations Installation instructions for shut-off valves Notes for project planning (hydraulic characteristic curves and circuits, installation regulations, commissioning, maintenance, etc.)
T5-A6..HL/A6..SL en v1.1 05.2012 Subject to changes
/4
www.belimo.com
285
T3
A6..HL
71157-00001.B
15 ... 20
1 5
OPEN 8 7 6
32
1 CLOSE
1 2
1 6
1 5 3 9 5 13 11 23 15 1 3 9 17 5 13 11 1 3 25 21 9 24 16 8 20 30 2 7 26 4 10 16 8 12 2 10 4 18 6 14 22 2 8 2 6 4 10 6 14
7 1
>0
7 19 29
15 23 7
17 5 21 13
16 24 8 20
18 6 22 14
1 3
19
2 1 3
A B
11
27
31
12
28
32
A M12 M16 M16 M16 M16 M16 M16 M16 M20 M20 M24 M24 M24
1 4
www.belimo.com
/2
A6..HL
>0
>0
90
90
4
32
1 CLOSE
OPEN 8 7 6 5
OPEN 8 7 6 5
32
1 CLOSE
100%
0%
/2
www.belimo.com
A6..SL
71156-00001.B
OPEN
3 3 1 4
PE
1 6
ISO 7005-2 EN 1092-2
1 15
O PE N E OS CL
15 ... 20
CLOSE
E OS CL
1 5
PE
E OS CL
1 7 9
5 3 5 13 16 8
2 8 2
6 4 10 6 14 12 4 10 18 6 14 22
2
15
7 11 23 1 3 9
17 5 13 21 9
24 16 8 20 30 2
>0
7 19 29 11 1 3 25
7 26
4 10
15 23 7
17 5 21 13
16 24 8 20
18 6 22 14
1 3
19
2 1 3
A
CLOS E OPE N
11
27
31
12
28
32
A M12 M16 M16 M16 M16 M16 M16 M16 M20 M20 M24 M24 M24
1 4
www.belimo.com
/2
A6..SL
PE
E OS CL
>0
>0
90
90
CLOSE CLOSE OPEN OPEN
CLOS E OPEN
100%
CLOS E OPEN
0%
CLOS E OPEN
/2
www.belimo.com