ENTERPRISE PROFLIE
Guangzhou Deron Heat Source Facilities Co., Ltd is developed by Deron Heat Pump Technology(Guangzhou) R&D Center and Deron Group Limited Company. The Company is a specialist in manufacturing marketing of pioneering heat source facilities.

Energy Saving Technology Changes the World DERON HEAT PUMP SYSTEM
How does a heat pump work?
A heat pump is a device moving heat energy from one place with lower temperature to another with higher temperature. This is done by extracting the heat from the air/earth. This heat is then upgraded to a higher temperature, before being delivered to the central heating system and hot water cylinder. Heat pumps also have the ability to do the reverse and provide a cooling system at warmer times of the year. Heat pumps are very economical, capable of cutting your heating bill by up to 70%. For every unit of electricity used to drive a heat pump, you can expect to produce 3-5 units of heat energy. The ratio between the heat produced and the electricity used to produce it, is refered to as the coefficienct of performance(COP).

DERON has brought in the advance heat pump technology from Germany and carried on to research, develop and innovate. DERON has established a world-class laboratory It is one of the first companies which is qualified for ISO9001 quality system, the European Union CE mark and the China Compulsory Certificate (CCC) in heat pump industry.

Up to now, in the world, DERON heat pumps including air to water heat pumps, water to water heat pumps and swimming pool heat pumps have provided good central heating solutions for hotels, hospitals, restaurants, schools, government institutions and residences, helping them save up to 75% of the power used originally.

Working principle
A heat pump works by driving a working fluid around a refrigeration circuit containing four elements; (1) evaporator, (2) compressor, (3) condenser , (4) expansion valve.

The company has utilized advanced facilities and equipments from all countries such as Italy, Japan and the United States, in order to set up four production lines: two high-precision sheet metal production lines and two test lines. Over 40 models of heat pump systems vary from 0.8kw to 250kw, four different series-household usages, central hot water systems, large scale constructions and air conditioning water heating system. Our heat pumps are sold to Germany, The United Kingdom, France, Spain, Austria, Czech Republic, Australia, Brazil, Chile, South Africa, as well as other countries in the world.

View of DERON Factory With high level laboratory and research staff, our production plant is able to supply you the world quality products. 1

PDF created with pdfFactory Pro trial version www.pdffactory.com

Table of contents
Air-to-water, Water-to-water, Swimming pool heat pump, Scroll/Screw heat pump, Household unit

1 Air to Water Heat Pump................................................................................................................................................................P-3 1.1 Air to Water Heat Pump Monobloc 380V/3ph/50Hz..............................................................................................................P-3 1.2 Air to Water Heat Pump Split Type for Cold Area . ..P-7 2. Air to Water Heat Pump DR Series:( Central Heating / Cooling + Hot Water) ..P-8

3. Household Heat pump with Coaxial Coil and Grundfos Pump..............................................................................................P-12 4. DW SERIES Heat Pump: Low Ambient (-25 ) ... .. . P-14

5. Water to Water Heat Pump.........................................................................................................................................................P-18 5.1 Water to Water heat pump Stand Type(Domestic or Commercial) .....................................................................................P-18 5.2 Water to Water heat pump SH series: Central heating + Hot water (Domestic Type) ........................................................P-21 6. Household Heat Pump Water Heater........................................................................................................................................P-23 6.1 Heat Pump Water Heater Split Type....................................................................................................................................P-23 6.2 Heat Pump Water Heater Integrative Type [All In One].......................................................................................................P-25 7. Swimming Pool/ SPA Air Source Heat Pump (Titanium Heat Exchanger).............................................................................P-27 7.1 Domestic Swimming Pool Heat Pump ... ...............................................................................P-27 7.2 Commercial Swimming Pool heat pump ...................................................................................P-29 7.2 Spa Heat Pump .. .........................................................................................P-32 9. Deron Production Line & Laboratory........................................................................................................................................P-33 10. Certificates and Trade shows..................................................................................................................................................P-36

PDF created with pdfFactory Pro trial version www.pdffactory.com

1.1 Air to Water Heat Pump Monobloc


!

! ! ! ! ! ! ! ! ! !

Operation range: -10"~+45" ambient temperature. 220V/1ph/50(60)Hz,380V/3ph/50(60)Hz. Threaded coaxial coil, Multiple protections to protect the compressor and the heat exchanger. largely increasing With auxiliary heating control, circulation pump control. efficiency! Optional modular controller is available. With timer function. Adjustable defrosting according to different weather conditions. With terminal for indoor thermostat, starting or standby the heat pump. Anti-corrosion case: durable coating; no-screw design with stainless steel bolts and nuts, no rust. Simple installation: can be placed on roof top, balcony, yard, or basement. Low noise. Long lifespan up to 15 years.

Deron Intelligent Remote Controller Indoor

DE-27WC, 36W/C, 46W/C

DE-27W/D, 36W/D, 46W/D,52W/D

DE-75W/D, 92W/D

DE-180W/D, 270W/D
3

PDF created with pdfFactory Pro trial version www.pdffactory.com

Air Source Heat Pump Monobloc 220V/380V Datasheet (50Hz/60Hz)

Model Power supply(V/ph/Hz) *Heating capacity **Heating capacity kw BTU kw BTU

DE-27W/C 220/1/50 10.8 24550 2.7 8.3 28160 2.2 240 1850 19.5 55 60 I IPX4 100 680X545X1055 2.2 2-3 G1" -10-45

DE-46W/C 380/3/50 18.4 49130 4.6 14.2 49130 3.8 415 2300 13 55 60 I IPX4 155 800X700X1000 4 3-5 G1" -10-45

DE-27W/D 220/1/50 10.8 24550 2.7 8.3 28160 2.2 240 1850 7.5 55 60 I IPX4 110 700X690X860 2.2 2-3 G1" -10-45

DE-36W/D 380/3/50 14.4 49130 3.6 11 37830 3 325 2100 10 55 60 I IPX4 145 800X700X1000 3 3-5 G1" -10-45

DE-46W/D 380/3/50 18.4 62780 4.6 14.2 48340 3.8 415 2300 13 55 60 I IPX4 155 800X700X1000 4 3-5 G1" -10-45 .

DE-52W/D 380/3/50 20.8 70970 5.2 16 54650 4.3 470 2500 15 55 60 I IPX4 165 800X700X1150 5 3-5 G1" -10-45

*Rated power input(kw)

**Rated power input(kw) Water feed speed(L/H) Refrigerant Refrigerant weight(g) Max.current(A) Rared water temp.#"$ Max.water temp#"$ Level against electric shock Water-proof grade Net weight(kg) Net size(mm) Required water flow rate(m3/h) Required tank cubage Water connection Operation temp.range#"$ Test condition

R417A/R407C/R410A

*Heating: Ambient temp. (DB/WB):20 /15 , Water temp. (Initial/Final):15 /55 **Heating: Ambient temp. (DB/WB):7 /6 , Water temp. (In/Out):30 /35 .

PDF created with pdfFactory Pro trial version www.pdffactory.com

Model Power supply(V/ph/Hz) *Heating capacity *Rated power input(kw) kw BTU **Rated power input(kw) Water feed speed(L/H) Refrigerant Refrigerant weight(g) Max.current(A) Rared water temp.#"$ Max.water temp#"$ Level against electric shock Water-proof grade Net weight(kg) Net size(mm) Required water flow rate(m3/h) Required tank cubage Water connection Operation temp.range#"$ Noise dB(A) **Heating capacity Test condition kw BTU

DE-105W/D DE-150W/D DE-180W/D 380/3/50 380/3/50 380/3/50 42 62 72 143300 211540 245660 10.5 15 18 32.3 47.7 55.4 110340 162880 189160 8.6 12.3 14.8 938 1330 1665 R417A/R407C/R410A 2100*2 2300X2 2500*2 2300*3 2300*4 21 25 28.5 40.5 49 55 55 55 55 55 60 60 60 60 60 I I I I I IPX4 IPX4 IPX4 IPX4 IPX4 165 275 295 495 622 1200X920X1255 1200X920X1255 1200X920X1455 2046*1180*1750 2400*1130*2300 6 8 8 12 16 5-8 7-10 8-12 10-15 15-20 G1-1/4" G1-1/4" G1-1/4" G2" G2" -10-45 -10-45 -10-45 -10-45 -10-45 %64 %65 %65 %68 %68 *Heating: Ambient temp. (DB/WB):20" /15", Water temp. (Initial/Final):15"/55". **Heating: Ambient temp. (DB/WB):7"/6", Water temp. (In/Out):30"/35".

DE-75W/D 380/3/50 30 102360 7.5 23.1 78820 6.2 678

DE-92W/D 380/3/50 36.8 125560 9.2 28.3 96680 7.5 825

PDF created with pdfFactory Pro trial version www.pdffactory.com

! COPELAND scroll compressor R417A. Emerson ALCO expansion valve. FULIHUA fan, aluminum-magnesium durable fan and Nylon fibre blades, quiet. ! Galvanized steel case with durable powder coating, no-screw design, no rust. ! High purity DuPont refrigerant: R417A, R407C, R410A. ! Model name explanation: C stands for side blowing direction. D stands for the up blowing direction. W stands for the mainframe.

PDF created with pdfFactory Pro trial version www.pdffactory.com

1.2 DERON Air to Water Heat Pump Split Type for Cold Area
Suitable for Low Ambient
DERON air to water heat pump split type is designed for cold area such as Northern Europe, Northern America. The system is split type, ensuring all water pipes indoor and avoiding freezed to damaged in cold winter. Moreover, the heat pump is optimized to run reliably at -15DegC ambient, creating a warm and comfortable living environment for customers.

With Auxiliary Heating Control Terminal


The controller is equipped with auxiliary heating terminal. This function is very necessary in cold winter. This function can be enabled or disabled by parameter setting.

Settable Defrosting
The defrosting temperature is settable according to different climate features, aiming at achieving the best defrosting efficiency.

Eco-friendly
The system uses R410a refrigerant with high purity, equipped with internationally name-brand compressors, ensuring stable operation in low ambient. R410a is an Eco-friendly refrigerant and well recognized in Northern Europe without CO2 emission.

Timer Function
The controller has timer function, starting or stopping the heat pump according to the timer setting by users.

Easy Installation
The system is designed for easy installation. The water connections are on top of the indoor unit, convenient.

Use your indoor thermostati!!!


The interlock terminal receives on/off signal from the indoor thermostati, thus starts or stanbys the heat pump. This function gives users a trouble-free operation and save more energy for users.

Low Noise
Slower fan with more blades is used for the outdoor unit, optimized for low noise. The indoor unit contains the quiet compressor, with anti-vibration design to reduce the noise to the most extent.

Comprehensive Protection
The intelligent controller has all-round protections (or protection function with terminals)to protect the heat pump. l Over-high/low pressure protection l Water flow protection terminal l Compressor heating cable protecton l Circulation pump anti-freezing protection

Working Principle:
Additional heat exchanger for daily hot water is optional to

according customers! need.

PDF created with pdfFactory Pro trial version www.pdffactory.com

2. Air to Water DR Series Heat Pump: Heat Recovery Heat Pump

DE-27W/DH, DE-46W/DH DE-75W/DH , DE-92W/DH DR Series Heat Pump ---- Heat Recovery: Central Heating/cooling + Hot Water
!

Intelligent DE-270W/DH, Indoor DE-180W/DH, DE-360W/DH Control Panel High efficiency Plate Type Heat Exchanger Stainless steel

Suitable for providing cooling and hot water(heat recovery) in hot region, suitable for providing heating and hot water in cold region. ! In summer, producing free sanitary water when cooling ! In winter, managing sanitary hot water and central heating synchronously ! With sanitary hot water temperature set value, controlling the hot water circulation pump.
! COPELAND scroll compressor for R417A.

Emerson ALCO expansion valve. High efficiency Plate heat exchanger. Nylon fiber durable blades.

DE-27W/DR

DE-46W/DR

DE-92W/DR

DE-180W/DR

PDF created with pdfFactory Pro trial version www.pdffactory.com

Model Power supply(V/ph/Hz) * Cooling capacity(kw) *Cooling capacity(BTU) * Cooling power input(kw) ** Heating capacity(kw) ** Heating capancity(BTU) ** Heating power input(kw) *** Heating capacity(kw) *** Heating capacity(BTU) *** Heating power input(kw) Max.current(A) Refrigerant Refrigerant weight(g) Level against electric shock Water-proof grade Net weight(kg) Net size(mm) Water connection Operation temp.range# $ Noise dB(A) Test condition

DE-27W/DR 220/1/50 7 23800 2.5 8 27300 2.7 11.2 38200 2.7 19.5 2800 I IPX4 115 700X690X860 G1" -10-45 "62

DE-36W/DR 220/1/50 9.6 32700 3.3 10.5 35800 3.6 15 51200 3.6 26 3500 I IPX4 150 800X780X1000 G1" -10-45 "64

DE-46W/DR 220/1/50 12 40900 4.3 13.5 46000 4.6 19.3 65800 4.6 33

DE-27W/DR 380/3/50 7 23800 2.5 8 27300 2.7 11.2 38200 2.7 7.5 2800 I IPX4 115 700X690X860 G1" -10-45 "62

DE-36W/DR 380/3/50 9.6 32700 3.3 10.5 35800 3.6 15 51200 3.6 10 3500 I IPX4 150 800X780X1000 G1" -10-45 "64

R417A/R407C/R410A 3500 I IPX4 150 800X780X1000 G1" -10-45 "64

*Cooling:Ambient temp.(DB/WB)35 /24 &Water temp.(In/Out):12 /7 **Heating:Ambient temp.(DB/WB)7 /6 &Water temp.(In/Out):40 /45 ***Sanitary:Ambient temp.(DB/WB)20 /15 ;Hot water temp.(Initial/Final): 15 /55

PDF created with pdfFactory Pro trial version www.pdffactory.com

Model Power supply(V/ph/Hz) * Cooling capacity(kw) *Cooling capacity(BTU) * Cooling power input(kw) ** Heating capacity(kw) ** Heating capancity(BTU) ** Heating power input(kw) *** Heating capacity(kw) *** Heating capacity(BTU) *** Heating power input(kw) Max.current(A) Refrigerant Refrigerant weight(g) Level against electric shock Water-proof grade Net weight(kg) Net size(mm) Water connection Operation temp.range#"$ Noise dB(A)

DE-46W/DR 380/3/50 12 40900 4.3 13.5 46000 4.6 19.3 65800 4.6 13 3500 I IPX4 150 800X780X1000 G1" -10-45 %64

DE-92W/DR 380/3/50 25 85300 8.6 28 95500 9.2 38.5 131300 9.2 25

DE-150W/DR 380/3/50 40 136500 13.2 45 153500 13.8 62 211500 18 37 3500*4 I IPX4 662 2400*1130*2300 G2" -10-45 %68

DE-180W/DR 380/3/50 50 170600 17.1 56 191000 18 81 276300 18 49 3500*4 I IPX4 662 2400*1130*2300 G2" -10-45 %68

R417A/R407C/R410A 3500*2 I IPX4 280 1200X920X1255 G1-1/4" -10-45 %65

Test condition

Cooling:Ambient temp.(DB/WB)35"/24"&Water temp.(In/Out):12"/7" Heating:Ambient temp.(DB/WB)7"/6"&Water temp.(In/Out):40"/45" Sanitary:Ambient temp.(DB/WB)20"/15";Hot water temp.(Initial/Final): 15"/55"

10

PDF created with pdfFactory Pro trial version www.pdffactory.com

System Diagram of DR series heat pump 5 modes to satisfy your need:


A: central cooling & sanitary hot water B: central heating & sanitary hot water C: single central cooling D: single central heating E: single sanitary hot water

11

PDF created with pdfFactory Pro trial version www.pdffactory.com

3. Household Heat Pump with Built-in GRUNFOS Pump Features:


# Can be connected with solar heating system as a back up heater. # Already with circulation pump, no need to install another circulation pump. # With timer function, connection to indoor thermostat, terminal for auxiliary heater. # Ultra quiet FULIHUA fan. # High COP. # With indoor control panel, convenient. # 4-way-valve revert circuit defrosting, with adjustable defrosting setting according to New design! More popular!!!

Basic Device
Compact design of this heat pump completely with components listed below:

New case for DE-13WB, 18WB, 27WB

36WB

DE-46WB DE-13WB, 18WB, 27WB 36WB PDF created with pdfFactory Pro trial version www.pdffactory.com

1! Circuit board 2! Grundfos water pump 3! Coaxial coil heat exchanger 4! FULIHUA Low Noise Fan 5! Compressor 6! Suction accumulator 7! Deron remote controller indoor.

Threaded coaxial coil, largely increasing efficiency!

12

Household Heat Pump with Coaxial Coil and Grunfos Pump Datasheet (50Hz/60Hz) Model Power supply(V/ph/Hz) *Heating capacity(kw) *Heating capacity#BTU$ Rated power input(kw) **Heating capacity(kw) **Heating capacity#BTU$ Rated power input(kw) Water feed speed(L/h) Max.current(A) Refrigerant Refrigerant weight(g) Level against electric shock Water-proof grade Net weight(kg) Net size(mm) Required water flow rate(m3/h) Water connection Operation temp.range#"$ Noise dB(A) Test Condition 1200 I IPX4 58 790*270*760 1.2 G3/4" -10-45 %48 1500 I IPX4 67 790*270*760 3 G3/4" -10-45 %48 DE-13WB 220/1/50 5.2 17700 1.3 4 13600 1.1 110 9.5 DE-18WB 220/1/50 7.2 24560 1.8 5.5 18700 1.6 155 13 DE-27WB 220V/1(380/3)/50 10.8 24550 2.7 8.3 28160 2.2 232 19.5/ or 7.2 R417A/R407C/R410A 2000 I IPX4 84 830*310*960 2 G1" -10-45 %48

Heating capacity from 4.8 to 17.88KW DE-36WB 220V/1(380/3)/50 14.4 49130 3.6 11 37830 3 310 25 or 10 2300 I IPX4 95 880*360*1050 3 G1" -10-45 %50 DE-46WB 380/3/50 18.4 62780 4.6 14.2 48340 3.8 395 13 2500 I IPX4 110 1120*425*1260 4 G1" -10-45 %52

*Heating:Ambient temp.(DB/WB):20"/15"; **Heating:Ambient temp.(DB/WB)7"/6";

Water temp.(Initial/Final):15"/55" ; Water temp.(In/Out)30"/35" .

! Panasonic Rotary/Copeland scroll compressor.

Emerson expansion valve. Grunfos circulation pump. High purity DuPont refrigerant.

! Threaded coaxial coil heat exchanger, galvanized phydrophilic fin-tube evaporator. ! The data above are based on R417A. We also produce these models with R407C or R410A.

13

PDF created with pdfFactory Pro trial version www.pdffactory.com

4. DERON AIR-TO-WATER DW SERIES HEAT PUMP (Ambient temp. from-25 ~45 ) Description:
DW series heat pump is specially designed for high water temperature hot water out put and available for low air temperature working in. DW series heat pump is specially designed according to cold climate features. Its core philosophy is to solve the user !s home eating during the cold climate in winter and spring, to make cooling in hot summer and autumn. By using Copeland new designed compressor, with Deron specially designed economizer and high efficiency has greatly improved. So the performance of the heat pump comes to a new height. According to the testing and validation, this type heat pump has a COP at -15" can reach 2.4, and available for 65 hot water output and safely working in -25 outside air temperature.

DE-27W/DW

DE-46W/DW

DE-92W/DW

DE-180W/DW

14

PDF created with pdfFactory Pro trial version www.pdffactory.com

Main components:
l l l l l l Compressor: Copeland new designed scroll compressor with gas injection increase enthalpy can get a more high efficiency. Heat exchanger: Stainless steel plate heat exchanger & Coaxial Coil heat exchanger. Evaporator: Hydrophilic high efficiency fin-tube evaporator. Expansion valves: Main thermal expansion valves & Spray thermal expansion valves. Electromagnetic valve: Emerson electromagnetic valve. Fan: FULIHUA fan with nylon fibred blades, durable, lower noise, longer life.
DE-46W/DW exhibited on the 108th Canton Fair.

Strong points:
l l l l l l l l Hot water output temperature up to 65". Suitable for cold area, safely working in -25" ambient temperature. COP can be up to 2.4, at -15". Eco-friendly refrigerant: R417A. Automata tic defrosting function included (with reverse cycle valve inside). Deron Intelligent Remote Controller Anti-corrosion case: durable coating; no-screw design with stainless steel bolts and nuts, no rust. General testing and operational test carried out for every before package in the factory. Comprehensive protection, --- ensures trouble free operation in extremely cold ambient. 1. Anti-freezing protection, 2.Water flow protection, 3.Over high pressure protection, 4.Over low pressure protection etc.

15

PDF created with pdfFactory Pro trial version www.pdffactory.com

Specified parameter list


Model DE-27W/DW DE-46W/DW DE-92W/DW DE-180W/DW DE-270W/DW DE-360W/DW

Power supply (V/ph/Hz) *Heating capacity#kW$ *Rated power input (kW) Water feed speed (L/h) **Heating capacity#kW$ **Rated power input (kW) Water feed speed (L/h) ***Heating capacity#kW$ ***Rated power input (kW) Water feed speed (L/h) Refrigerant Refrigerant weight (g) Max. current (A) Rated water temp. (") Max. water temp. (") Level against electric shock Water-proof grade Net weight (Kg) Net size (mm) Required water flow rate (m3/h) Required tank cubage (t) Water connection Operation temp. range (") Noise dB (A)

220/1/50 11.6 2.7 250 6 2.5 129 4.6 2.6 98 2000 18.5 55 60 I IPX4 130 800X700X1000 2.2 2-3 G1" -25-45 %60

380/3/50 19.8 4.6 425 10.2 4.3 219 7.9 4.4 170 2500 13 55 60 I IPX4 175 800X700X1150 4 3-5 G1" -25-45 %64

380/3/50 380/3/50 39.5 81 9.2 18 850 1665 20.5 40.3 8.5 16.8 440 866 15.8 31 8.8 17.2 340 666 R417A/R407C/R410A 2500*2 2500*4 25 49 55 55 60 60 I I IPX4 IPX4 320 680 1200X920X1455 2400X1130X2300 8 16 7-10 15-20 G1-1/4" G2" -25-45 %65 -25-45 %68

380/3/50 121.5 27 2495 60.4 25.1 1298 46.5 25.9 1000 2500*6 73.5 55 60 I IPX4 960 2400X1400X2300 24 25-30 G3" -25-45 %68

380/3/50 162 36 3328 80.5 33.5 1730 61.9 34.4 1330 2500*8 98 55 60 I IPX4 1600 2400X2260X2300 32 35-40 G3" -25-45 %68

16

PDF created with pdfFactory Pro trial version www.pdffactory.com

Comparison of -25 heat pump & normal heat pump Specified parameter list
Difference DE-27W/D(normal) Standard 3HP DE-27W/DW "-25C heat pump! Double row 3HP ZW30KS-PFS (With Compressor ZR34KH-PFJ-522 gas injection increase enthalpy scroll compressor) Main Thermal expansion valves (BAE1-1/2HW100) thermal Main BAE5HCA thermal expansion BAE5HCA ZR61KH-TFD-522 DE-46W/D(normal) Standard 5HP DE-46W/DW (-25C heat pump) 6HP ZW61KS-TFP (With gas injection increase enthalpy scroll compressor) DE-92W/D(norm al) Standard 10HP DE-92W/DW(-25C heat pump) 12HP 2*ZW61KS-TFP (With gas injection increase enthalpy scroll compressor)

Evaporator

2*ZR61KH-TFD522

expansion valves(BAE1-1/2HW100 ) & Spray thermal expansion valves ( BAE1HCA)

2* Main

thermal expansion

Thermal expansion valves

valves(BAE3HW100) & Spray thermal expansion valves ( BAE2HCA)

valves(BAE3HW100) & 2* Spray thermal expansion valves ( BAE2HCA)

Plate heat exchanger Electromagnetic valve Liquid storage pot Operation temp. Range#"$ COP(at +20") COP(at -15") COP(at -25")

No

BL20-12D 2* Emerson electromagnetic valve KFR120WLG01 -25~43 4.2 2.4

No

BL20-16D 2* Emerson electromagnetic valve KFR120WLG01 -25~43 4.2 2.4

No

2*BL20-16D 4*Emerson electromagnetic valve 2*KFR120WLG01 -25~43 4.2 2.4

No No -10~43 4.1 <1.5

No No -10~43 4.1 <1.5

No No -10~43 4.1 <1.5

cannot work

1.8

cannot work

1.8

cannot work

1.8

17

PDF created with pdfFactory Pro trial version www.pdffactory.com

5.1. Water to Water Heat Pump Standard Type (Domestic or Commercial)


! Safe: Water-electricity separation technology, completely safe. ! Long life: Service life reach up to 15 years. Low maintenance cost. ! Modular design available. ! High COP up to 4.4 at W15/W40. ! With auxiliary heating control terminal and circulation pump control terminal. ! Suitable for water source or brine source with glycol. ! Quiet: low noise design for indoor installation, with noise insulation inside the case. ! Anti-corrosion: durable coating; special case design by using stainless steel bolts and nuts, no screws, no damage to the coating, no rust happen.

Noble Case! European Style! Light-touch pad control panel

DE-27W/S, DE-46W/S Stainless steel

DE-27W/S, DE-36W/S,DE-46W/S, DE-52W/S, DE-75W/S, DE-92W/S

DE-150W/S, DE-180W/S

Stainless steel Plate heat exchanger


18

PDF created with pdfFactory Pro trial version www.pdffactory.com

Water to Water Heat Pump Standard Type Datasheet


Model Power(V/ph/Hz) * Heating capacity(kw) * Heating capacity(BTU) * Rated power input(kw) ** Heating capacity(kw) ** Heating capacity(BTU) **Rated power input(kw) *** Heating capacity(kw) *** Heating capacity(BTU) ***Rated power input(kw) Refrigerant Refrigerant weight(g) Max current(A) Rated water temp.#"$ Max.water temp.#"$ Level against electric shock Water-proof grade Net weight(kg) Net size(mm) Packing size#mm$ Required hot water flow rate(m3/h) Required water source flow rate(m3/h) water connection Noise dB(A) 1600 19.5 55 60 I IPX4 80 600*470*830 680*550*930 2.2 1.8 G1" "40 2200 26 55 60 I IPX4 100 600*620*830 680*700*930 3.2 2.45 G1" "40 DE-27W/S 220/1/50 12.5 42600 2.7 11.5 39200 2.3 8.5 29000 2.3 DE-36W/S 220/1/50 16.5 56300 3.6 15 51200 3 11.0 37500 3 DE-46W/S 220/1/50 21 71600 4.6 19 64800 3.8 14.0 47800 3.8 2500 33 55 60 I IPX4 120 600*620*830 680*700*930 4 3.2 G1" "42 DE-36W/S 380/3/50 16.5 56300 3.6 15 51200 3 11.0 37500 3 2200 10 55 60 I IPX4 100 600*620*830 680*700*930 3.2 2.4 G1" "40 DE-46W/S 380/3/50 21 71600 4.6 19 64800 3.8 14.0 47800 3.8 2500 13 55 60 I IPX4 120 600*620*830 680*700*930 4 3.2 G1" "42 DE-52W/S 380/3/50 24 81800 5.2 22.5 76700 4.5 17.0 58000 4.5 2800 15 55 60 I IPX4 140 600*620*830 680*700*930 4.8 3.8 G1" "42
19

R417A/R407C/R410A

PDF created with pdfFactory Pro trial version www.pdffactory.com

! COPELAND flexible scroll compressor for R417A., Sanyo or Daikin scroll compressor for R407C and R410a.
!Emerson ALCO expansion valve. ! High efficiency Plate Type heat exchanger. ! High purity DuPont refrigerant. ! Models mark in red have got CE. 20

PDF created with pdfFactory Pro trial version www.pdffactory.com

5.2 Water to Water Heat Pump SH Series: Central Heating + Daily Hot Water (Domestic Type)
Deron SH series water to water heat pump is designed to provide an all-round solution for house, including central heating and daily hot water heating, completely taking the place of traditional boilers, saving more cost for users than normal water-water heat pumps do.

With Auxiliary Heating Control Terminal


3 Operation modes There are 3 operation modes in the SH series controller: Mode 1: central heating only, with set value for the water temperature, with the circulation pump control terminal. Mode 2: daily hot water only, with set value for the daily hot water temperature, with the circulation pump control terminal. Mode 3: central heating + daily hot water. Circulation pump stops after its own water cycle reaches the set value. The compressor stops only after both water cycles are satisfied. The heat pump starts again as long as either cycle requires heating. The controller is equipped with auxiliary heating terminal for the central heating cycle. This function is very necessary in cold winter. This function can be enabled or disabled by parameter setting.

Noble Appearance
l l l The design is completely a household application style in European market. The control panel is light-touch pad type. Invisible-screw design.

Easy Installation
All water connections come out from the top panel, allowing the heat pump placed in any corner inside the house. Storage room or basement is the ideal installation place.

Comprehensive Protection
The intelligent controller has all-round protections (or protection function with termincals)to protect the heat pump. l Over-high pressure protection l Over-low pressure protection l Water flow protection terminal l Compressor heating cable protecton l Circulation pump anti-freezing protection

Low Noise
The whole heat pump is optimized to reduce vibration at the most extent to reduce the noise. Anti-vibration piping design, with noise insulation inside the case, ensures the noise level as low as down to 35dBA of model DE-27W/SH.
21

PDF created with pdfFactory Pro trial version www.pdffactory.com

Water to Water Heat Pump SR series Datasheet

! COPELAND flexible scroll compressor for R417A., Sanyo scroll compressor for R407C and R410a. ! Emerson ALCO expansion valve. ! High efficiency Plate Type heat exchanger. ! High purity DuPont refrigerant.
22

PDF created with pdfFactory Pro trial version www.pdffactory.com

6.1 Household Heat Pump Water Heater Split Type


! Hot water outlet up to 60 ". ! High COP up to 4.6. High efficiency tank heat insulation, extremely low heat loss. ! Durable: Service life can reach up to 15 years. Low maintenance cost. ! Safe: water-electricity separation technology, no creepage, completely safe. ! All weather operation: Stable operation without being influenced by weather, even snow or rain. ! Environment friendly: No pollution or waste discharged in entire working cycle. ! Fashionable: The design is fashionable with durable coating in different colors, perfectly matching your house style. ! Simple installation: It can be placed on the roof top, balcony, yard, or basement, no special room necessary. ! Quiet: Low noise, no disturbance to owners and neighbors.

Controller

Grey

Yellow

Stainless Steel

Champagne

Outdoor unit

23

PDF created with pdfFactory Pro trial version www.pdffactory.com

Household Heat Pump Water Heater Split Type Datasheet (50Hz)

Heating capacity from 3.6 to11.3KW

Emerson expansion valve. ! The data above are tested at ambient temperature 20",input water 15",output water 55". ! The meaning of the letters: L stands for liter.

! Panasonic Rotary compressor.

24

PDF created with pdfFactory Pro trial version www.pdffactory.com

6.2 Household Heat Pump Water Heater Integrative Type [All in One]
! Suitable for -10 ! ! ! ! ! ! !

~+45 ambient temperature. Efficient: High COP, high efficiency heat insulation for the inside cylinder, extremely low heat loss. Reliable: Service life can reach up to 15 years. Low maintenance cost. Durable: With stainless steel case and high qualified compressor. Long service life can reach up to 15 years. All weather operation: Stable operation without being influenced by weather, even snow or rain. Environment friendly: No pollution or waste discharged to entire working surrounding. Economic: The running costs of Deron heat pump can be 80% less than that of a traditional gas boilers. Simple installation: It can be placed on the roof top, balcony, yard, or basement, no special room necessary. Deron Intelligent Controller Indoor Remote

A view of the inside

DE-100LY/DE-150LY/DE-200LY

25

PDF created with pdfFactory Pro trial version www.pdffactory.com

Household Heat Pump Water Heater All in One Type Datasheet (50Hz)

Heating capacity 5.3 KW

Model Power Supply(V/Ph/Hz) Heating Capacity(kw) Rated Power (kw) Water Production Speed (L/h) Type of Refrigerant Refrigerant Weight(g) Max. Working Current (A) Rated Heating Temp. (") Max. Heating Temp. (") Anti-shock Grade Water Proof Grade Outdoor Unit Weight (kg) Water Connection Ambient Temperature (") Noise (dB) Test condition

DE-100LY (Cylinder) 220-240/1/50 5.3 1.25 115 1000 8 55 60 I IP$4 73 G1/2% -10~45 "48

DE-150LY (Cylinder) 220-240/1/50 5.3 1.25 115 1000 8 55 60 I IP$4 80 G1/2% -10~45 "48

DE-200LY (Cylinder) 220-240/1/50 5.3 1.25 115 1000 8 55 60 I IP$4 85 G1/2% -10~45 "48

DE-150LY* DE-180LY* 220/1/50 5.3 1.25 115 1000 8 55 60 I IP$4 102/133 G1/2% -10~45 "48 DE-150LY*/DE-180LY*

R417A/R407C/R 410a

Ambient'dry/wet bulb 20"/15" Hot water'initial/final temp.15"/55"

! Panasonic Rotary compressor.

Emerson expansion valve. ! The data above are tested at the ambient temperature 20",inlet water 15",outlet water 55". ! Model name explanation: L stands for litre, Y stands for Integrative. DE-150LY*/DE-180LY*
26

PDF created with pdfFactory Pro trial version www.pdffactory.com

7.1 Domestic Swimming Pool Heat Pump (Titanium Heat Exchanger)


With 100% Titanium eliminating corrosion and maximizing heat transfer efficiency
! Cooperation range: -10"~+45" ambient temperature. ! Safe: Water electricity separation technology, no creepage, completely safe. ! Efficient: Stable performance with high COP up to 5.5. ! Compact: small, taking up little space, easy installation. ! Durable: designed for placed outdoor, resisting all kinds of weather. ! Anti-corrosion case: galvanized steel with durable powder coating. ! With remote wire control panel indoor, completely automatic operation. ! With multiple protections, ensuring long life. ! Return water temperature is pre-set at the range of 28

Intelligent Remote Controller Indoor

~30

(normal) for swimming pool use, also according to users! requirement.

Inner 100% titanium, outer PVC, max temp 40!

DE-18W/CY exhibited on IFA 2010, Berlin, Germany.

DE-13, 18, 27, 36W/CY


27

PDF created with pdfFactory Pro trial version www.pdffactory.com

Domestic Swimming Pool Heat Pump Datasheet (50Hz/60Hz)-

Inner Titanium Outer PVC Heat Exchanger

! CIE/FULIHUA blower, nylon fibred blades, durable, lower noise, longer life. ! High purity DuPont refrigerant. ! Model name explanation: C stands for the lateral blowing direction. D stands for the top blowing direction. W stands for the mainframe. Y stands for

swimming pool use. J stands for domestic use.

28

PDF created with pdfFactory Pro trial version www.pdffactory.com

7.2 Commercial Swimming Pool Heat Pump (Titanium Heat Exchanger)


With 100% Titanium Tubing to eliminate all corrosion and maximize heat transfer efficiency
! Coperation range: -10"~+45" ambient temperature. ! Safe: Water electricity separation technology, no creepage, completely safe. ! Reliable: Stable performance with high COP up to 6.0. ! Durable: 100% titanium heat exchanger for anti-corrosion from chlorine, long life. ! Designed for placed outdoor, simple installation and replacement. ! Anti-corrosion case: galvanized steel with durable powder coating; no-screw case design, no rust happen. ! With remote wire control panel indoor, completely automatic operation. ! With automatic defrosting, with auxiliary heating control terminal. ! Return water temperature is pre-set at the range of 28"~30"(normal) for swimming pool use, also according to users! requirement.

1. Inner 100% titanium, outer PVC, max temp 40! 2. Inner 100% titanium, outer stainless steel, max temp 60!

Intelligent Remote Controller Indoor

DE-27W/DY,DE-46W/DY

DE-46W/DY

DE-18W/CY, DE-27W/CY,DE-46W/CY

DE-92W/DY DE-180W/DY

29

PDF created with pdfFactory Pro trial version www.pdffactory.com

Model Power supply(V/ph/Hz) Compressor rated power(kw) Heating capacity(kw) Power input(kw) Refrigerant Refrigerant weigh(g) Max.current(A) Rated water temp.#"$ Level against electric shock Water-proof grade Net weight(kg) Net size(mm) Required water flow rate(m3/h) Water connection(mm) Operation temp.range#"$ Noise dB(A) Test condition l l l
l l 100% pure Titanium heat exchanger.

DE-27W/DY 380/3/50 2.7 11 1.9 1850 7.5 28 I IPX4 90 700*690*860 4.5 50mm -10-45 %60

DE-36W/DY 380/3/50 3.6 14.5 2.7 2000 10 28 I IPX4 120 800*780*1000 6 50mm -10-45 %64

DE-46W/DY 380/3/50 4.6 18 3.1 R417A/R407C/R410A 2300 13 28 I IPX4 130 800*780*1000 7.5 50mm -10-45 %64

DE-52W/DY 380/3/50 5.2 22 3.7 2500 15 28 I IPX4 140 800*780*1000 9 50mm -10-45 %64

DE-75W/DY 380/3/50 7.5 31 5.5 2200*2 21 28 I IPX4 260 1200*920*1225 12 63mm -10-45 %65

Ambient temp.(DB/WB):20"/15" Water temp.(Initial/Final):15"/28"

COPELAND scroll compressor for R417A. Emerson ALCO expansion valve. CIE/FULIHUA blower, nylon fibre blades, durable, lower noise, longer life.
Evaporator: galvanized-hydrophilic fin-tube, bigger and wider. High purity imported DuPont refrigerant. No-screw case design, galvanized coated steel or stainless steel.

Model name explanation: C stands for the lateral blowing direction. D stands for the up blowing direction. W stands for the mainframe. Y stands for swimming pool use. P stands for the PVC.

30

PDF created with pdfFactory Pro trial version www.pdffactory.com

Model Power supply(V/ph/Hz) Compressor rated power(kw) Heating capacity(kw) Power input(kw) Refrigerant Refrigerant weigh(g) Max.current(A) Rated water temp.#"$ Level against electric shock Water-proof grade Net weight(kg) Net size(mm) Required water flow rate(m3/h) Water connection(mm) Operation temp.range#"$ Noise dB(A) Test condition

DE-92W/DY 380/3/50 9.2 39 6.7 2300*2 25 28 I IPX4 250 1200*920*1225 15 63mm -10-45 %65

DE-105W/DY 380/3/50 10.5 46.5 8.2 2500*2 30 28 I IPX4 290 1200*920*1425 15 63mm -10-45 %65

DE-150W/DY 380/3/50 15 62 11.3 2300*3 25 28 I IPX4 495 2046*1180*1750 18 90mm -10-45 %68

DE-180W/DY 380/3/50 18 74 13.5 2300*4 29 28 I IPX4 622 2400*1130*2300 20 90mm -10-45 %68

DE-225W/DY 380/3/50 22.5 110 20 2500*4 37 28 I IPX4 670 2400*1130*2300 25 110mm -10-45 %68

DE-270W/DY 380/3/50 27 148 27 3450*4 49 28 I IPX4 893 2400*1400*2300 30 110mm -10-45 %68

R417A/R407C/R410A

Ambient temp.(DB/WB):20"/15" Water temp.(Initial/Final):15"/28"

1. Inner titanium, outer PVC, max temp 40!

31

PDF created with pdfFactory Pro trial version www.pdffactory.com

7.3 Spa Heat Pump Datasheet (50Hz/60Hz)Model Heating Capacity Power Input COP Power Supply Compressor Refrigerant Condenser Throttling Device Evaporator Fan Blowing Type Water Flow Volume Water Connection Case Operation Range Noise
dB(A) M3/h #mm material mm V/ph/Hz Type Qty KW BUT/h KW

Inner Titanium-steel coil Heat Exchanger


DE-27W/CYS 10.8 36800 2.7 4.0 220/1/50 Rotary 1 DE-27W/CYS 10.8 36800 2.7 4.0 220/1/50 Scroll 1 DE-36W/CYS 14.4 49200 3.6 4.0 220/1/50 Scroll 1 DE-46W/DYS 18.4 62800 4.6 4.0 220/1/50 Scroll 1

DE-13W/CYS 4.8 16500 1.3 3.7 220/1/50 Rotary 1

DE-18W/CYS 7.2 25000 1.8 4.0 220/1/50 Rotary 1

R417A/R407C / R410A 100% titanium-steel coil shell heat exchanger Emerson ALCO thermostatic expansion valve Galvanized hydrophilic fin-tube heat exchanger Lateral blowing 1.8 48 2.0 48 2.8 48 3.0 48 3.5 48 Top blowing 4.0 60

Powder coating steel White, grey or any other color according to customer!s need. 1000*300*620 50 1000*300*620 52 1120*425*710 54 . 1120*425*710 54 1120*425*710 56 800*780*1000 57

! The data above are tested at ambient temperature 20",initial water temp15",final water temp 55 ! Titanium-steel heat exchanger. Max. water temp. up to 60". ! Case design can follow customer !s requirement. ! FULIHUA blower with nylon fibre blades, durable, lower noise, longer life.

Inner titanium, outer stainless steel, max temp 60! ! Model name explanation: D stands for the up blowing direction. W stands for the mainframe. C means lateral blowing direction. P means for spa use.
! Durable powder coating, no rust.

32

PDF created with pdfFactory Pro trial version www.pdffactory.com

33

PDF created with pdfFactory Pro trial version www.pdffactory.com

34

PDF created with pdfFactory Pro trial version www.pdffactory.com

l While you are considering


We provide free consolation on the model of heat pump system, system design, and cost estimation that can be suit for your needs.

l After you purchase the product


The first installation can be carried out by us, by sending engineers to your country helping you with the installation, in a safe and efficiency manner. Not familiar with how to work with the system yet? Don!t worry, we offer training on how to operate the system so that you can make the best use of your heat pump.

l Satisfaction guarantee:
There is an 18 months warrantee for air-to-water heat pumps and water-to-water heat pumps, and 24 months warrantee for swimming pool heat pumps.

35

PDF created with pdfFactory Pro trial version www.pdffactory.com

36

PDF created with pdfFactory Pro trial version www.pdffactory.com

37

PDF created with pdfFactory Pro trial version www.pdffactory.com

Trade Shows:
1) PISCINA BCN 2011 Barcelona, Spain 2) InterSolar 2011 Munich, Germany 3) ISH 2011 Frankfurt, Germany 4) Energiespar Messe2011 Austria 5) Home Appliances @IFA -2010 Berlin, Germany 6) The 105th China Import & Export Fair (Canton Fair); April 15th-19th, 2009; Guangzhou, China 7) The 6th China International SME Fair & China-Spain SME Fair; September 22th-25th, 2009; Guangzhou, China 8) The106th China Import & Export Fair (Canton Fair); October 15th-19th, 2009; Guangzhou, China 9) The 6th China-ASEAN Expo; October 20th-24th, 2009; Nanning, China 10) The 2010MIECF Macao International Environmental Co-operation Forum & Exhibition; April 8th-10th, 2010; Macao, China 11)The IFA Exhibition; November 4th-9th, 2010; Berlin, Germany 12)The108th China Import & Export Fair (Canton Fair); 12)The110th China Import & Export Fair (Canton Fair); 13)PISCINA BCN 2011 Barcelona, Spain 14) Eco Expo Asia,HK,China
OEM orders are welcomed

Guangzhou Deron Heat Source Facilities Co., Ltd. Zhongping Ave,Zhongcun Town,Panyu Dist,511495 Guangzhou,China Mail:Gavin@deron.com.cn www.deronheatpump.com/ Skype:deronheatpump

Deron # Export Department Phone: +86 20 22883030 Fax: +86 20 28685651 MSN:deronheatpump@hotmail.com deron.en.alibaba.com/

38

PDF created with pdfFactory Pro trial version www.pdffactory.com

Potrebbero piacerti anche