Documenti di Didattica
Documenti di Professioni
Documenti di Cultura
Instalao
Calha Parshall
MEDIDOR DE VAZO EM CANAIS ABERTOS
Cd: 073AA-025-122M
Setembro / 2004
Incontrol S/A.
Rua Joo Serrano, 250 Bairro do Limo So Paulo SP CEP 02551-060
Fone: (0xx11) 3858-4443 FAX: (0xx11)3856-7268
e-mail: assistecnica@levelcontrol.com.br
Calha Parshall
Incontrol
NDICE
1.
INTRODUO ...................................................................................................................... 2
2.
3.
CONSTRUO. .................................................................................................................... 4
4.
5.
INSTALAO. ...................................................................................................................... 7
6.
OPERAO. ......................................................................................................................... 7
7.
MANUTENO..................................................................................................................... 8
8.
9.
______________________________________________________________________
1
Calha Parshall
1.
Incontrol
INTRODUO
______________________________________________________________________
2
Calha Parshall
2.
Incontrol
PRINCPIO DE FUNCIONAMENTO.
Figura 1
O trecho convergente, tambm chamado de crista, produz um nvel, no liquido
medido, que est diretamente relacionado com a vazo.
Com um auxilio de um medidor de nvel externo adequado, podemos obter
leituras de vazo com uma boa preciso.
Atravs de observaes e experincias, os resultados obtidos correspondem a
expresses do tipo:
Q = KHn
Onde:
______________________________________________________________________
3
Calha Parshall
3.
Incontrol
CONSTRUO.
Capacidade de Vazo
Min
Max
[inch]
[m /h]
[m /h]
1.02
19.4
2.04
47.9
3.06
115
5.10
398
9.17
907
12
11.2
1641
18
15.3
2508
24
42.8
3374
36
62.2
5138
48
132
6922
60
163
8726
72
265
10551
84
306
12376
96
357
14221
120
612
20388
144
816
35679
180
816
61164
240
1019
101941
300
1529
122329
360
1529
152911
480
2039
203881
600
2548
305822
Tabela 1
______________________________________________________________________
4
Calha Parshall
Incontrol
Figura 2
DIMENSES
E
T
G
2/3A
[inch]
[mm]
[mm]
[mm]
[mm]
[mm]
[mm]
[mm]
[mm]
[mm] [mm]
1
2
3
6
9
12
18
24
36
48
60
72
84
96
120
144
180
240
300
360
480
600
363
414
467
621
880
1372
1448
1524
1677
1829
1981
2134
2286
2438
242
276
311
414
587
914
965
1016
1118
1219
1321
1423
1524
1625
1829
2032
2337
2845
3353
3861
4877
5893
356
93
168
229
406
135
214
254
457
178
259
610
610
394
397
610
864
381
575
762
1343 610
845
914
1419 762
1026 914
1495 914
1207 914
1645 1219 1572 914
1794 1524 1937 914
1943 1829 2302 914
2092 2134 2667 914
2242 2438 3032 914
2391 2743 3397 914
4267 3658 4756 1219
4877 4470 5607 1524
7620 5588 7620 1829
7620 7315 9144 2134
7620 8941 10668 2134
7925 10566 12313 2134
8230 13818 15481 2134
8230 17272 18529 2134
76.2
114
152
305
305
610
610
610
610
610
610
610
610
610
914
914
1219
1829
1829
1829
1829
1829
203
254
305
610
457
914
914
914
914
914
914
914
914
914
1829
2438
3048
3658
3962
4267
4877
6096
19.0
22.2
25.4
76.2
76.2
76.2
76.2
76.2
76.2
76.2
76.2
76.2
76.2
76.2
152
152
229
305
305
305
305
305
305
305
381
381
381
381
457
457
457
457
457
[mm]
[mm]
[mm] [mm]
[mm]
28.6
42.9
57.2
114.3
114.3
228.6
228.6
228.6
228.6
228.6
228.6
228.6
228.6
228.6
342.9
342.9
457.2
685.8
685.8
685.8
685.8
685.8
902
1080
1492
1676
1854
2223
2711
3080
3442
3810
4172
406
406
508
508
508
508
610
610
610
610
610
12.7
25.4
38.1
76.2
76.2
76.2
76.2
76.2
76.2
76.2
76.2
76.2
76.2
76.2
305
305
305
305
305
305
305
305
7.94
9.52
25.4
50.8
50.8
50.8
50.8
50.8
50.8
50.8
50.8
50.8
50.8
50.8
229
229
229
229
229
229
229
229
Tabela 2
______________________________________________________________________
5
Calha Parshall
Incontrol
Fibra de Vidro
b-)
Ao Carbono revestido
c-)
Ao Inox
d-)
Concreto
4.
SELEO DE TAMANHO.
b-)
c-)
d-)
e-)
b-)
2-)
Onde:
c-)
d-)
e-)
f-)
______________________________________________________________________
6
Calha Parshall
5.
Incontrol
INSTALAO.
b-)
c-)
d-)
e-)
f-)
Pode-se construir com aclive de 1:4, uma rampa inicial no incio da seo
convergente.
g-)
h-)
i-)
O medidor de nvel deve estar instalado nos locais indicados na figura XX,
Ha e Hb.
6.
OPERAO.
______________________________________________________________________
7
Calha Parshall
7.
Incontrol
MANUTENO.
______________________________________________________________________
8
Calha Parshall
8.
Incontrol
FORMULAS E TABELAS.
[mm]
1
2
3
6
9
12
18
24
36
48
60
72
84
96
120
144
180
240
300
360
480
600
25,4
50,8
76,2
152,4
228,6
304,8
457,2
609,6
914,4
1219,2
1524,0
1828,8
2133,6
2438,4
3048,0
3657,6
4572,0
6096,0
7620,0
9144,0
12192,0
15240,0
1,550
1,550
1,547
1,580
1,530
1,522
1,538
1,550
1,556
1,578
1,587
1,595
1,601
1,606
1,600
1,600
1,600
1,600
1,600
1,600
1,600
1,600
217,29
434,58
633,60
1371,60
1926,00
2484,00
3794,40
5133,60
7855,20
10566,00
13420,80
16254,00
19101,60
21963,60
26865,77
31893,72
39439,05
52019,16
64599,27
77179,38
102332,78
127493,00
Tabela 3
______________________________________________________________________
9
Calha Parshall
9.
Incontrol
MEDIDOR DE NVEL.
O medidor Parshall pode ser fornecido com escala graduada em vazo, nas
unidades de engenharia de sua escolha. As unidades mais comuns so: m3/h,
l/min, l/s ou m3/h.
Atualmente, o medidor de nvel mais utilizado nas Calha Parshall do tipo
ultra-snico, por sua preciso (0,25% FE), e por sua praticidade, pois, como o
sensor no entra em contato direto com o fluido, no h problemas de
incrustaes. Alm disso, tambm temos a vantagem de transmitir distncia,
atravs sinal eltrico, os valores de vazo (instantnea ou totalizada), seja por
um sinal analgico 4-20mA, seja por uma comunicao digital do tipo RS485.
O medidor de nvel ultra-snico possui um conversor com leitura direta ou
vazo, na unidade de engenharia desejvel, como tambm podendo totalizar o
volume do lquido que j passou pelo medidor Parshall.
______________________________________________________________________
10
Calha Parshall
Incontrol
Incontrol
______________________________________________________________________
11