Documenti di Didattica
Documenti di Professioni
Documenti di Cultura
com/locate/jpba
Short communication
A method for simultaneous determination of ve anticoagulant rodenticides in whole blood by high-performance liquid chromatography
Fuyu Guan a,1, Akira Ishii a, Hiroshi Seno a, Kanako Watanabe a, Takeshi Kumazawa b, Osamu Suzuki a,*
a b
Department of Legal Medicine, Hamamatsu Uni6ersity School of Medicine, 3600 Handa -cho, Hamamatsu 431 -3192, Japan Department of Legal Medicine, Showa Uni6ersity School of Medicine, 1 -5 -8 Hatanodai, Shinagawa -ku, Tokyo 142, Japan Received 17 June 1998; received in revised form 25 November 1998; accepted 1 January 1999
Keywords: Anticoagulant rodenticide; Warfarin; Coumatetralyl; HPLC; Analytical toxicology; Whole blood
1. Introduction Anticoagulant rodenticides of 4-hydroxycoumarin and indandione derivatives are agricultural chemicals widely used for pest control in many countries. Human poisonings, caused by accidental or intentional ingestion of these over-the-counter chemicals, were reported [1 7]. Methods for detection and determination of these rodenticides are required both for diagnosis and effective treatment of the intoxication and for forensic purposes. A number of techniques, such as gas
* Corresponding author. Tel.: + 81-53-4352239; fax: + 8153-4352239. E -mail address: houigaku@akiha.hama-med.ac.jp (O. Suzuki) 1 On leave from Beijing Institute of Pharmacology and Toxicology, Beijing 100850, Peoples Republic of China.
chromatography coupled with mass spectrometry (GCMS) [8], thin-layer chromatography (TLC) [9] and immunoassay [10], were used for measurements of anticoagulant rodenticides in biological matrices; however, high performance liquid chromatography (HPLC) appears most effective [11 26]. Most of the published methods dealt with a single group of compounds, 4-hydoxycoumarins or indandiones. A few reports described simultaneous determination of both 4-hydoxycoumarins and indandiones in serum [1315] or animal organ tissue [11,12,18], under different extraction or HPLC conditions; but no reports are available for whole blood samples. In forensic science practices, whole blood analysis is essential especially for hemolyzed blood samples. In this report, a rapid and convenient method is described for simultaneous determination of ve common rodenticides in whole blood.
0731-7085/99/$ - see front matter 1999 Elsevier Science B.V. All rights reserved. PII: S 0 7 3 1 - 7 0 8 5 ( 9 9 ) 0 0 1 0 8 - 9
180
2. Experimental
2.1. Chemicals
Warfarin was purchased from Sigma (St Louis, MO, USA). Coumatetralyl and bromadiolone were obtained from Beijing Institute of Microbiology and Epidemiology (Beijing, PRC); diphacinone and chlorophacinone from Beijing Institute of Pharmacology and Toxicology (Beijing, PRC). Their identity was conrmed by the presence of quasi-molecular ion peaks in atmosphere pressure chemical ionization (APCI) mass spectra, and purity by HPLC with ultraviolet (UV) detection. Di-n -butylammonium acetate (DBA, 0.5M aqueous solution, pH 7.4) used as ion-pairing reagent was obtained from Tokyo Kasei Organic Chemicals (Tokyo, Japan); acetonitrile of HPLC grade from Wako Pure Chemical Industries (Osaka, Japan). Other common chemicals used were of analytical grade. Human whole blood was taken from healthy subjects, and stored in the presence of EDTA 2Na at 4C. Warfarin, coumatetralyl, diphacinone and chlorophacinone (1.0 mg ml 1 each) were dissolved in acetonitrile, and bromadiolone (1.0 mg ml 1) in methanol (HPLC grade). These stock solutions were stored at 4C. The working standard mixture (100 mg ml 1 for each rodenticide) was prepared by diluting the aliquots of the stock solutions, stored at 4C, and stable for at least 1 month. More dilute standard mixtures were prepared daily.
Separations were carried out using gradient elution with mobile phase A, acetonitrile:DBA (5 mM in water) = 20:80, and mobile phase B, acetonitrile:DBA (5 mM) = 70:30. The gradient program expressed as the change in mobile phase A was as follows: 03 min, hold at 100%; 37 min, a linear decrease to 60%; 721 min, a linear gradient to 0% and 21.126 min, switch to and hold at initial condition (100%). The mobile phase ow rate was 0.20 ml min 1. The detection wavelength was 315 nm for both 4-hydroxycoumarins and indandiones. HPLC separations were conducted at ambient temperature.
181
Fig. 1. (Continued )
182
Vitamins K1, K2 and K3 are clinically used as antidotes to treat patients poisoned by anticoagulants. They did not overlap the peaks of the latter under the present HPLC conditions.
Table 1 Recoveries of rodenticides from human whole blood by ethyl acetate extraction (n = 6) Rodenticides Warfarin Coumatetralyl Diphacinone Chlorophacinone Bromadiolone Added (mg ml1) 0.50 2.0 0.50 2.0 0.50 2.0 0.50 2.0 0.50 2.0 Founda (mg ml1) 0.46 9 0.022 1.8 9 0.065 0.44 9 0.015 1.7 9 0.040 0.40 9 0.020 1.4 9 0.032 0.38 9 0.019 1.4 9 0.038 0.37 9 0.031 1.3 9 0.050 Recoveries (%) (X 9 SD) 92 9 4.4 90 9 3.3 88 9 3.0 85 9 2.2 80 9 4.0 70 9 1.6 76 9 3.8 70 9 1.9 74 9 6.2 65 9 2.5 CV (%) 4.8 3.7 3.4 2.6 5.0 2.3 5.0 2.7 8.4 3.8
F. Guan et al. / J. Pharm. Biomed. Anal. 21 (1999) 179185 Table 2 Calibration equations and detection limits of rodenticides in human blood y = mx+b a Detection limitsb (mg ml1) (1.0, 2.0, 4.0, 6.0, 8.0,10 mg ml1) mc (1.34 9 0.01) 10 (1.45 9 0.02) 10 (1.43 9 0.04) 10 (9.67 9 0.28) 104 (4.39 9 0.12) 10
4 5 5 5
183
(0.10, 0.20, 0.40, 0.60, 0.80, 1.0 mg ml1) mc Warfarin Coumatetralyl Diphacinone Chlorophacinone Bromadiolone (1.33 9 0.06) 10 (1.51 9 0.05) 10 (1.64 9 0.03) 10 (1.17 9 0.01) 105 (5.17 9 0.11) 10
4 5 5 5
bc (1.56 9 3.35) 10 (3.50 9 3.20) 10 (2.64 9 1.73) 10 (1.69 9 0.85) 103 (6.95 9 6.37) 10
2 3 3 3
bc (2.20 9 8.28) 10 (7.14 9 10.5) 10 (2.46 9 2.69) 10 (2.46 9 1.72) 104 (1.31 9 0.74) 10
4 4 3 3
r2 0.999 0.999 0.996 0.996 0.996 0.05 0.05 0.05 0.05 0.05
a y was the peak area of an anticoagulant rodenticide, x was its concentration in whole blood and r 2 was the square of the correlation coefcient. b Whole blood containing a series of different concentration of the analytes was extracted and chromatographed, and the lowest concentration, at which an analyte produced a signal three times higher than baseline noise, was designated to be the detection limit. c The value of m and b were expressed as average 9 SD. For diphacinone, chlorophacinone and bromadolone, the slope of the calibration line was lower in the high concentration range than in the low concentration range, which might be caused by a lower extraction recovery at higher concentration of the analyte.
Table 3 Within-day and day-to-day variations Within-day Blood from one persona Added (mg ml1) Warfarin Coumatetralyl Diphacinone Chlorophacinone Bromadiolone 0.50 2.0 0.50 2.0 0.50 2.0 0.50 2.0 0.50 2.0 Found (X 9 SD) 0.52 9 0.027 2.0 9 0.077 0.55 9 0.020 2.2 9 0.054 0.53 9 0.026 2.1 9 0.049 0.54 9 0.027 2.1 9 0.063 0.58 9 0.044 2.0 9 0.084 CV (%) 5.1 3.7 3.7 2.5 5.0 2.4 4.9 3.1 7.6 4.2 Blood from ve personsb Found (X 9 SD) 0.55 9 0.055 2.1 9 0.17 0.58 9 0.047 2.3 9 0.19 0.53 9 0.49 2.2 9 0.22 0.54 9 0.061 2.2 9 0.24 0.53 9 0.084 2.1 9 0.31 CV (%) 10 8.1 8.3 8.3 9.2 10 11 11 16 15 Day to day Blood from one person Found (X 9 SD) 0.59 9 0.063 2.1 9 0.10 0.59 9 0.066 2.3 9 0.090 0.55 9 0.015 2.3 9 0.17 0.55 9 0.026 2.2 9 0.17 0.53 9 0.013 2.0 9 0.15
c
Six aliquots of one-persons blood were spiked with rodenticides and analyzed with external calibration. Five aliquots of blood from ve persons were spiked and analyzed. c Spiked blood was kept at 4C and analyzed on six separate days, with one sample each day.
b
184
4. Conclusion A method for determination of anticoagulant rodenticides in whole blood has been developed, and validated by successful measurements of a dosed rodenticide in rat blood. To our knowledge, it is the rst report for whole blood samples. It is recommendable for detection and determination of anticoagulant rodenticides in clinical and forensic analytical toxicology.
Acknowledgements Fuyu Guan is grateful to the Ministry of Education, Science and Culture of Japan for its nancial support with the fellowship.
References
[1] C.H. Hui, A. Lie, C.K. Lam, C. Bourke, Forensic Sci. Int. 78 (1996) 13 18. [2] P. Mura, A. Piriou, Y. Papet, D. Lochon, D. Reiss, J. Anal. Toxicol. 16 (1992) 179 181. [3] E.Y. Chow, L.P. Haley, L.M. Vickars, M.J. Murphy, Can. Med. Assoc. J. 147 (1992) 60 62. [4] B. Haug, L. Schjodt-Iversen, J. Rygh, Tidsskrift for Den Norske Laegeforening 112 (1992) 1958 1960 (Norwegian). [5] D. Chataigner, R. Garnier, J. Elmalem, M.L. Efthymiou, Ann. Med. Interne 139 (1989) 537 541 (French). [6] C. Burucoa, P. Mura, R. Robert, C. Boinot, S. Bouquet, A. Piriou, J. Toxicol. Clin. Toxicol. 27 (1989) 79 89.
Fig. 2. High-performance liquid chromatography (HPLC) chromatograms of (a) diphacinone (1.0 mg) dosed to a rat and (b) blank rat blood. For other conditions, see Section 2.
F. Guan et al. / J. Pharm. Biomed. Anal. 21 (1999) 179185 [7] J.J. Vogel, P. de Moerloose, C.A. Bouvier, J. Gaspoz, P. Riant, J. Suisse de Medecine 118 (1988) 19151917 (French). [8] A.M. Dufeld, M. Kennedy, D.J. Birkett, D.N. Wade, Austral. New Zea. J. Med. 9 (1979) 534537. [9] P.G. Welling, K.P. Lee, U. Khanna, J.G. Wagner, J. Pharm. Sci. 59 (1970) 16211625. [10] M.E. Mount, M.J. Kurth, D.Y. Jackson, J. Immunoassay 9 (1988) 69 81. [11] V. Fauconnet, H. Pouliquen, L. Pinault, J. Anal. Toxicol. 21 (1997) 548 553. [12] A. Jones, Bull. Environ. Contam. Toxicol. 56 (1996) 815. [13] E.A. Kuijpers, J. den Hartigh, T.J. Savelkoul, F.A. de Wolff, J. Anal. Toxicol. 19 (1995) 557562. [14] F.Y. Guan, L. Liu, Y. Luo, Chinese J. Anal. Chem. 23 (1995) 159 161. [15] T. Chalermchaikit, L.J. Felice, M.J. Murphy, J. Anal. Toxicol. 17 (1993) 56 61. [16] L.J. Felice, T. Chalermchaikit, M.J. Murphy, J. Anal. Toxicol. 15 (1991) 126129.
185
[17] S.M. OBryan, D.J. Constable, J. Anal. Toxicol. 15 (1991) 144 147. [18] K. Hunter, E.A. Sharp, J. Chromatogr. 437 (1988) 301 305. [19] K. Hunter, E.A. Sharp, A. Newton, J. Chromatogr. 435 (1988) 83 95. [20] K. Hunter, J. Chromatogr. 321 (1985) 255 272. [21] K. Hunter, J. Chromatogr. 299 (1984) 405 414. [22] K. Hunter, J. Chromatogr. 270 (1983) 277 283. [23] K. Hunter, J. Chromatogr. 270 (1983) 267 276. [24] D.E. Mundy, A.F. Machin, J. Chromatogr. 234 (1982) 427 435. [25] J.B. Addison, J. Assoc. Off. Anal. Chem. 65 (1982) 1299 1301. [26] K.G. Koubek, J.P. Ussary, R.E. Haulsee, J. Assoc. Off. Anal. Chem. 62 (1979) 1297 1301. [27] G. Vigh, Z. Vara-Puchony, A. Bartha, S. Baloh, J. Chromatogr. 241 (1982) 169 176. [28] M. Schulz, A. Schmoldt, Pharmazie 52 (1997) 895 911.