FX3U/FX3UC
PERFORM AN CE
16-384
FX3G/FX3GE
14-256
FX3S
10-30
Sequence Controller
ALPHA
6-28
I /O
The FX Family ..................................................................................................................................150 Main Units Overview.........................................................................................................................152 Main Unit Configuration....................................................................................................................155 Configuration Rules..........................................................................................................................159 Programming and Device Specifications..........................................................................................160 Environmental and Electrical Specifications......................................................................................161 Main Unit Options.............................................................................................................................162 FX Input / Output Expansion Options................................................................................................166 FX Analog Options............................................................................................................................168 FX High-Speed I/O and Positioning Expansion.................................................................................171 FX Communications and Networking Expansion..............................................................................173 Networking Modules.........................................................................................................................173 FX Interfaces and Power Supplies....................................................................................................175 Accessories.......................................................................................................................................176 Sequence Controllers - Alpha2 Series..............................................................................................178 Software............................................................................................................................................181
Stock Product: Stock product is product MEAU makes every effort to have on hand for immediate shipment. There may be instances when we are out of stock due to unexpected large requirements. All stock product will be indicated in this book by an S in the Stocked Item columns/rows. Non-Stock Product: Non-stock product is product supplied on an as-needed basis. Standard lead times of 12 - 16 weeks apply, product is non-returnable and non-cancelable. Product listed as non-stock may change to stock product subject to increases in sales and usage. All non-stock product will be indicated in this book by a dash - in the Stocked Item columns/rows.
The FX Family
The FX family of PLCs is highly flexible, enabling fast and efficient configuration for the application at hand. It is the ideal choice for simple control systems requiring up to 30 I/O (FX3S), or a more complex system with up to 384 I/Os (FX3U).
Model Power Supply Maximum I/O Digital I/O Cycle Period / Logical Instruction Memory
* With remote I/O
FX Standards Compliance: All FX products are manufactured under ISO 9000 quality assurance and 14001
environmental management standards. In addition, most FX PLC products are certified by internationally recognized standards agencies. The Ratings section of the specifications tables lists the approvals for each product. The approval agencies are as follows:
corresponding Canadian approvals Complies to the European EMC and LVD directives Det Norske Veritas Lloyds Register Germanischer Lloyd
ABS: American Bureau of Shipping RINA: Registro Italiano Navale BV: Bureau Veritas NK: Nippon Kaiji Kyokai KC: Korea Certification
FXControl Solutions
FX PLCs have been designed to be used in a variety of industry areas with a focus on compact applications. With over 11,000,000 PLCs sold world wide, the FX PLCs have been fitted to variety of applications in a range of different industry areas. Examples of a few industries where FX PLCs are used include the timber industry, food industry, textile industry, plastics industry, printing industry, packaging industry and water processing industry.
Analog Control
Expanding the FX PLC with analog inputs and outputs is required when the system needs to handle voltage or current inputs/outputs, temperature inputs, or temperature or PID control. The following expansion boards, special adapters, and special function blocks support different ranges and combinations of these features.
Analog Input
Ammeter or Pressure Sensor Analog Input Device FX
Analog Output
Motor or Inverter Control Analog Output Device FX
Temperature Input
Temperature Sensor Analog Input Device FX
A/D convert
A/D convert
PT100/PT1000/Ni1000 Thermocouple
A/D convert
High-Speed Control
All FX Series PLCs are equipped with built-in open collector high-speed counters. These high-speed inputs are connected to external devices such as encoders and ultrasound sensors for system feedback control.
FX Integrated High-Speed Counter
Open Collector Inputs Rotary Encoder or Sensor Gauge
FX3U / FX3UC
8ch max.
2ch max.
150
Inverter Control
Parameters and commands between the PLC and Mitsubishi Inverters can be handled through serial communication using FREQROL protocol. Another popular control method for these controllers include Analog Control.
RS-485 Communication Equipment
Inverter FX3S FX3G Analog Board
RS-485 Communication
Analog Speed Control (0-10V DC, 4-20mA) Motor
OR
FX 3U/FX 3UC/FX3G/FX3S
* Applicable Inverters: F700/A700/E700/V500/F500/A500/E500/S500
Positioning
The built-in high-speed pulse outputs on all transistor-type FX Series PLCs, are designed to satisfy simple independent-axis positioning applications. For more advanced applications, the SSCNET Special Function Block provides high performance positioning control.
Within an application, control devices can be made up from equipment from different manufacturers, however sustaining reliable communication between devices is essential. Supported networks: Ethernet, CC-Link, PROFIBUS, DeviceNet, and Modbus.
Direction
1st Axis 100kHz 2nd Axis 100kHz 3rd Axis 100kHz
DeviceNet
2 Axes
200kHz 200kHz
Serial Communication
N:N Network
Multidrop networks, non-protocol communication, and remote maintenance are just some of the many uses.
Computer Link (Dedicated Protocol)
Communication with a PC 1:N Computer to PLC Communication The PC can communicate with a network of up to 16 FX, A, and Q PLCs.
RS-485Communication 16 PLCs Max. Station 0 RS-485 Communication Station n RS-485 Communication Equipment Computer (PC) RS-485 Communication Equipment
Communication between FX Series PLCs Connect up to 8 FX PLCs using N:N Networking to allow data exchange between each station.
RS-485 Communication Station 0 Station 1 8 FX PLCs Max. Station n
Communication with a PC
Remote Maintenance
Using a modem connection, a PC can monitor/force devices and perform program upload/download to a PLC from remote locations.
Computer (with GX Developer) Modem RS-232C Communication Modem
Parallel Link
Auxiliary Relays (M) and Data Registers (D) are updated automatically between two PLCs of the same series.
Master Station RS-485 Communication Slave Station
1:1 RS-232C Communication Equipment to PLC When communicating over an RS-232C interface, the PC can communicate with one FX PLC.
RS-232C Communication
Speed
Analog Positioning
Communication
Expandability
Memory
The FX3U is the original dual system-bus, high-speed, fully expandable compact PLC designed to seamlessly control communication, networking, analog, and positioning systems. 3rd generation compact PLC High efficiency with more speed, more performance, more memory, and new functions Built-in high-speed processing and positioning Exchangeable communication expansion boards that mount directly into the main unit (USB, RS-232C, RS-422, RS-485) Simultaneous memory cassette and display module mounting available Integrated real-time clock Easy programming with large instruction set and table positioning configuration Large programming memory Programming with GX Works2 or GX Works2 FX
Product Details
All-in-one CPU, power supply and I/O. Includes many upgraded features from the FX2N, including high expandability using Expansion Boards and Special Adapters to add functionality.
Basic Instructions: 0.065 s / instruction (Contact Instruction) Applied Instructions: 0.642 s / instruction (MOV Instruction)
Large Memory
64,000 steps of built-in program memory Flash Memory Cassettes with loader functionality also available
Auxiliary Relays: Timers: Counters: Data Registers: Extension Registers: Extension File Registers:
7,680 points 512 points 235 points 8,000 points 32,768 points 32,768 points (with optional memory cassette)
Speed Communication Analog Positioning
Expandability
Memory
Controllable I/O: 16 - 384 points with CC-Link or AS-i remote I/O Main Unit I/O: 16/32/64/96 points
The FX3UC is the new ultra-compact high-speed, fully expandable PLC. Based on 24VDC power and using connector-type transistor I/O, the FX3UC is designed for space conscious and modular applications. 3rd generation Super-compact PLC Reduced size and wiring using connector-type I/O Built-in high-speed processing and positioning Ultra-compact design featuring connector-type wiring for installation space optimization 64k steps of internal program memory Integrated real-time clock Easy programming with large instruction set and table positioning configuration Programming with GX Works2 or GX Works2 FX Relay output
Product Details
Ultra-compact size main unit including many upgraded features from the FX2NC, including high expandability using Special Adapters to add functionality.
Basic Instructions: 0.065s / instruction (Contact Instruction) Applied Instructions: 0.642s / instruction (MOV Instruction)
Large Memory
64,000 steps of built-in program memory Flash Memory Cassettes with loader functionality also available
Auxiliary Relays: Timers: Counters: Data Registers: Extension Registers: Extension File Registers:
7,680 points 512 points 235 points 8,000 points 32,768 points 32,768 points (with optional memory cassette)
152
Controllable I/O: 14 - 256 points (with CC-Link remote I/O) Main Unit I/O: 12/24/40/60 points
The FX3G is an introductory compact PLC that is the latest addition to the FX3 Series. With control of directly connected and networked I/O, connectivity to the FX3 Series ADP bus and new expansion boards makes the FX3G ideal for simple yet performance critical applications. 3rd generation compact PLC Highly flexible Dual bus architecture- 32k steps of internal program memory Integrated real-time clock Easy programming with large instruction set and table positioning configuration Built-in USB port for the programming communication function to enable high-speed communication at 12Mbps Two built-in variable analog potentiometers available for adjusting the timer set time Programming with GX Works2 or GX Works2 FX
Product Details
All in one CPU, power supply and I/O. Includes many upgraded features from the FX1N. Especially usage of the FX3 Series ADP bus system and new expansion boards (BD).
Basic Instructions: 0.21s / instruction (Contact Instruction) 32,000 steps of built-in program memory. EEPROM memory cassette with loader function is available.
Auxiliary Relays: Timers: Counters: Data Registers: Extension Registers: Extension File Registers:
7,680 points 320 points 235 points 8,000 points 24,000 points 24,000 points
Speed Communication Expandability Analog Positioning Memory
Controllable I/O: 24 - 256 points (with CC-Link remote I/O) Main Unit I/O: 24/40 points The FX3GE combines the powerful FX3G CPU with built-in Ethernet communications and analog I/O to provide a cost-effective micro PLC that can meet the needs of a wide variety of applications right out of the box. 3rd generation compact PLC Highly flexible Embedded Ethernet communications port Embedded analog I/O (2 inputs, 1 output) Dual bus architecture - 32k steps of internal program memory Integrated real-time clock Easy programming with large instruction set and table positioning configuration Built-in USB port for the programming communication function to enable high-speed communication at 12Mbps. Two built-in variable analog potentiometers available for adjusting the timer set time. Programming with GX Works2 or GX Works2 FX
Product Details
All in one CPU, power supply and I/O. Also includes an Ethernet communications port and analog inputs and outputs. Can use all the same expansion options as FX3G.
Basic Instructions: 0.21s / instruction (Contact Instruction) 32,000 steps of built-in program memory. EEPROM memory cassette with loader function is available.
Auxiliary Relays: Timers: Counters: Data Registers: Extension Registers: Extension File Registers:
7,680 points 320 points 235 points 8,000 points 24,000 points 24,000 points
Speed Communication
Expandability
The FX3S is the fit-and-forget PLC solution for space and cost conscious applications requiring up to 30 I/O. This minimumexpandability, battery-less maintenance free controller is perfect for handling straightforward processes and can be hidden away in locations without regular maintenance activities. 3rd generation basic compact PLC High performance with minimal size Integrated power supply (AC powered) Maintenance-free EEPROM memory Ample memory capacity (4000 steps) and device ranges Built-in USB port for the programming communication function to enable high-speed communication at 12Mbps Built-in positioning control Integrated real-time clock Increased functionality using Expansion Boards and Special Adapters Programming with GX Works2 or GX Works2 FX
Product Details
All-in-one CPU, power supply and I/O. Expansion options includes adapter and expansion boards for communication, analog control, or temperature input.
Basic Instructions: 0.21s / instruction (Contact Instruction) Applied Instructions: 0.5s / instruction (MOV Instruction)
Large Memory
154
5
Analog ADP
4
Communication ADP
3
High-Speed Output ADP High-Speed Input ADP
1 2
Board
7
FX 3U /FX 2N Special Function Blocks
8
FX 3U Power Supply Unit
FX 3U Main Unit
Expansion Boards
Communication FX3U -232-BD FX3U -422-BD FX3U -485-BD FX3U -USB-BD Interface Board
FX 2N I/O Expansions
FX3U -422-BD
Special Adapters
Communication FX3U -232ADP-MB FX3U -485ADP-MB FX3U -ENET-ADP
4
n FX3U Main Units 16-128 I/O
FX3U -32MR
9
FX 3U -4AD- PTW-ADP
F X3U -4AD -PTK-ADP
POWER
PO WE R
24+
24+
5
FX 3 U -4HSX-AD P
3
FX
3U
-2HSY -ADP
FX3U -16MR/ES FX3U -16MT/ES FX3U -16MT/ESS FX3U -16MR/DS FX3U -16MT/DS FX3U -16MT/DSS FX3U -32MR/ES FX3U -32MT/ES FX3U -32MT/ESS FX3U -32MR/DS FX3U -32MT/DS FX3U -32MT/DSS FX3U -32MR/UA1 FX3U -32MS/ES
AC AC AC DC DC DC AC AC AC DC DC DC AC AC
D D D D D D D D D D D D E D D
R T1
T2
R T1 T2 R T1 T2 R T1 T2 R TR
FX3U -48MR/ES FX3U -48MT/ES FX3U -48MT/ESS FX3U -48MR/DS FX3U -48MT/DS FX3U -48MT/DSS
AC AC AC DC DC DC AC AC AC DC DC DC AC AC
D D D D D D D D D D D D E D
R T1 T2 R T1 T2 R T1 T2 R T1 T2 R TR
FX3U -80MR/ES FX3U -80MT/ES FX3U -80MT/ESS FX3U -80MR/DS FX3U -80MT/DS FX3U -80MT/DSS
AC AC AC DC DC DC
D D D D D D
R T1 T2 R T1 T2
24-
24-
PLS DIR
FX3U -CF-ADP
FX3U -4AD-PNK-ADP Temperature FX3U -4AD-PT-ADP FX3U -4AD-TC-ADP FX3U -4AD-PTW-ADP FX3U -4AD-PNK-ADP
FX3U -4HSX-ADP FX3U -2HSY-ADP High Speed Counter FX3U -4HSX-ADP Positioning FX3U -2HSY-ADP
FX3U -64MR/ES FX3U -64MT/ES FX3U -64MT/ESS FX3U -64MR/DS FX3U -64MT/DS FX3U -64MT/DSS FX3U -64MR/UA1 FX3U -64MS/ES
J-type
J-type
X0/3
L1+
L1+
L1-
X1/4
L2+
L2+
L2-
X2/5
L2-
L3+
L3+
X6/7
L3-
L3-
SG SG
L4+
L4-
SGB
L4-
Y5/7
L4+
Y1/3
SGA
Y4/6
L1-
Y0/2
AC AC Power supply E
AC Input
DC DC Power supply
DC Input (sink/source)
Output Extension Blocks FX2N -8EYR-ES/UL FX2N -8EYT-ESS/UL FX2N -8EYR-S-ES/UL FX2N -16EYR-ES/UL FX2N -16EYT-ESS/UL FX2N -16EYS
OUT
FX2N -48ER
FX2N -8EX Analog FX2N -2AD FX3U -4AD FX2N -2DA FX3U -4DA FX2N -5A FX2N -8AD Temperature FX2N -2L FX2N -4AD-TC FX2N -4AD-PT FX3U-4LC
FX2N -16EYR Positioning FX3U-1PG FX2N -10PG FX3U -20SSC-H FX2N -1RM-E-SET
Network FX2N -32CCL FX3U -16CCL-M FX3U -64CCL FX3U -ENET FX3U -32DP FX3U -64DP-M Communication FX2N -232IF
FX 3U-1PSU-5V
FX 3U-20SSC-H
FX 3 U -64CCL
FX0N -3A
FX3U -20SSC-H
FX3U -64CCL
n Interface Converter
FX-USB-AW FX-232AWC-H
n Software
GX Developer GX Works2 GX Works2 FX
Accessories
FX3U -FLROM-64 FX3U -FLROM-16 FX3U -FLROM-64L FX3U -FLROM-1M FX3U -FLROM-64L
n Memory Cassettes
FX3U -7DM
FX3U -7DM
FX3U -7DM-HLD
9
CF Card ADP
2
Communication ADP
4
2NC
5
Special Function Blocks FX 3UC -1PS-5V or
6
FX 2N Unpowered I/O FX 2NC -CNV-IF
7
2N
8
Special Function Blocks
Analog ADP
FX 2NC I/O
Expansions
FX 3UC /FX
Special Adapters 3
FX 3U -4AD-PTW-ADP
FX 3U -232ADP-MB
POWER
POWER RD SD
J-type
24-
24+
L1-
L1+
FX 3 U -4AD-PTK-ADP
FX 3U -485ADP- MB
PO WER
POWER RD SD
L3+
L2-
L2+
L3-
L4-
L4+
24-
24+
FX3U -4AD-ADP
J-type
L3+
L3-
L4+
L4-
FX3U -4AD-PNK-ADP Analog FX3U -4AD-ADP FX3U -4DA-ADP FX3U -3A-ADP Temperature FX3U -4AD-PT-ADP FX3U -4AD-TC-ADP FX3U -4AD-PTW-ADP FX3U -4AD-PNK-ADP
SG
SDB
SDA
RDB
RDA
FX3U -232ADP-MB
L2-
L2+
L1-
L1+
FX 3UC /FX
Expansions
FX3UC -64MT/DSS
9
Data Storage FX 3U -CF-ADP
FX3UC -32MT/D* FX3UC -32MT/DSS FX3UC -64MT/D* FX3UC -64MT/DSS FX3UC -96MT/D* FX3UC -96MT/DSS
DC D1 T1 DC D2 T2 DC D1 T1 DC D2 T2 DC D1 T1 DC D2 T2
4
Input Extension Blocks
FX 2NC -32EX -DS
POWER X0 1 2 3 X4 5 6 7 X0 1 2 3 X4 5 6 7 X0 1 2 3 X4 5 6 7 X0 1 2 3 X4 5 6 7
6
FX 3UC -1PS-5V
PO WER
Input Extension Blocks FX2N -8EX-ES/UL FX2N -8EX-UA1/UL FX2N -16EX-ES/UL Output Extension Blocks FX2N -8EYR-ES/UL FX2N -8EYT-ESS/UL FX2N -8EYR-S--ES/UL FX2N -16EYR-ES/UL FX2N -16EYT-ESS/UL FX2N -16EYS
FX 2NC -16EYR-T-DS
PW Y0 1 2 3 Y4 5 6 7 Y0 1 2 3 Y4 5 6 7
FX2NC -16EX-T-DS FX2NC -16EX-DS FX2NC -32EX-DS Output Extension Blocks FX2NC -16EYR-T-DS FX2NC -16EYT-DSS FX2NC -32EYT-DSS
OR
FX3UC -1PS-5V Interface Converter FX2NC -CNV-IF
OUT
FX 2N -16EYR
FX2NC -32EX
FX2NC -16EYR-T
FX 2N -2AD
Network 8 FX3U -32DP FX2N -32CCL FX3U -16CCL-M FX3U -64DP-M FX3U -ENET FX3U -64CCL Temperature FX2N -2LC FX3U-4LC FX2N -4AD-TC FX2N -4AD-PT High Speed Counter FX2N -1HC FX3U-2HC Communication FX2N -232IF
5
FX 3U C -4AD
POWER
FX 3U-4DA
FX 3U-20SSC-H
FX 3U -64CCL
Analog FX3UC -4AD FX2NC -4DA High Speed Counter FX2NC -1HC
D /A
FX3U -4DA
FX 2N -2AD
FX 3U -20SSC-H
FX3UC -4AD
Analog FX2N -2AD FX3U -4DA FX3U -4AD FX2N -5A FX2N -2DA FX2N -8AD
n Interface Converter
FX-USB-AW FX-232AWC-H
n Software
GX Developer GX Works2 GX Works2 FX
Accessories
FX3U -FLROM-64 FX3U -FLROM-16 FX3U -FLROM-64L FX3U -FLROM-1M
n Connector Parts
FX2C -I/O-CON FX2C -I/O-CON-S FX2C -I/O-CON-SA
n Terminal Blocks
FX-16E-TB/UL FX-16EYR-ES-TB/UL FX-16EYS-ES-TB/UL FX-16EYT-ESS-TB/UL FX-32E-TB/UL
n Extension Cables
FX0N -30EC (30cm) FX0N -65EC (65cm)
FX-16E-TB
156
5
Analog ADP
4
Communication ADP
3
Interface Converter ADP
1
FX 3G Main Unit 14/24 I/O Points
6
FX 2N I/O Expansions
7
FX 3U /FX 2N Special Function Blocks
8
FX 3U Power Supply Unit
5
Analog ADP
4
Communication ADP
3
Interface Converter ADP FX 3G Main Unit 40/60 I/O Points
6
FX 2N I/O Expansions
7
FX 3U /FX 2N Special Function Blocks
8
FX 3U Power Supply Unit
5
Analog ADP
4
Communication ADP FX3GE Main Unit
6
FX 2N I/O Expansions
7
FX3U / FX2N Special Function Blocks
8
FX 3U Power Supply Unit
2
BD1
3
BD1
2
BD2
2 2
BD1
Expansion Boards
Communication FX 3G -232-BD FX 3G -422-BD FX3G-485-BD FX3G-485-BD-RJ*
*Available 12/2013
FX3G-232-BD
Special Adapters 5 4 3
FX 3G -24MT/ES FX 3G -40MT/ES
FX 3G -40MR/ES FX 3GE-40MR/ES FX 3GE-40MR/DS FX 3G -40MT/ES FX 3G -40MT/ESS FX 3G -40MR/DS FX 3G -40MT/DS FX 3G -40MT/DSS FX 3G -60MR/ES FX 3G -60MT/ES FX 3G -60MT/ESS FX 3G -60MR/DS FX 3G -60MT/DS FX 3G -60MT/DSS
AC AC DC AC AC DC DC DC AC AC AC DC DC DC
D D D D D D D D D D D D D D
R R R T1 T2 R T1 T2 R T1 T2 R T1 T2
FX3U-4AD-ADP FX3U-4AD-PNK-ADP Analog FX3U-4AD-ADP FX3U-4DA-ADP FX3U-3A-ADP Temperature FX3U-4AD-PT-ADP FX3U-4AD-TC-ADP FX3U-4AD-PTW-ADP FX3U-4AD-PNK-ADP
AC DC D
6
Input/Output Extension Blocks
IN
FX2N-48ER
FX2N-8EX
FX3U -4DA
FX3U -1PSU-5V
FX 3U -1PSU-5V
FX3U-4DA
Accessories
Memory Cassette Display Module Extension Cables
FX 0N -30EC(30cm) FX 0N -65EC(65cm) FX 0N -65EC
FX3G-5DM
Battery
FX 3U -32BL
Interface Converter
FX-232AWC-H GT14 GX Developer GX Works2 GX Works2 FX
Software
FX3G-EEPROM-32L
FX3G-5DM
5
Analog ADP
4
Communication ADP
3
Interface Converter ADP
1
FX3S Main Unit
2
BD1
Expansion Boards
Communication FX 3G -232-BD FX 3G -422-BD FX3G-485-BD FX3G-485-BD-RJ*
*Available 12/2013
FX3G-232-BD
Special Adapters 5 4 3
FX3S-10MR/ES
AC AC AC AC AC AC
D D D D D D
R T1 T2 R T1 T2
FX3U-4AD-ADP FX3U-4AD-PNK-ADP Analog FX 3U -4AD-ADP FX 3U -4DA-ADP FX 3U -3A-ADP Temperature FX 3U -4AD-PT-ADP FX 3U -4AD-TC-ADP FX 3U -4AD-PTW-ADP FX 3U -4AD-PNK-ADP
FX3U-232ADP-MB
AC D
Accessories
Memory Cassette
Interface Converter
FX-232AWC-H GT14 GX Developer GX Works2 GX Works2 FX
Software
FX 3G -EEPROM-32L
4
FX 2NC Communication ADP
3
Interface Converter Boards
2
Expansion Boards
FX 1N Main Unit
Special Adapters 4
Expansion Boards 2
Communication Boards FX1N -232-BD FX1N -485-BD FX1N -422-BD
FX 2NC -232ADP
FX 2NC -485AD P
FX 2NC -ENET-ADP
POWER RD SD
POWER RD SD
FX1N-2AD-BD
100-240 VA C
S/S
X0
X1
X2
X3
X4
X5
X6
X7
0 1 2 3 4 5 6 7
MITSUBISHI
POWER RUN ERROR
IN
FX1S-14MR
OUT
0 1 2 3 4 5
Y4 Y2 Y1 Y0 0V Y5 Y3 24V COM0 COM1COM2 14MR -ES/UL
FX1S-14MR
FX2NC -232ADP
FX 2NC -485ADP Communication Adapters FX2NC -232ADP FX2NC -485ADP FX2NC -ENET-ADP
FX1N-1DA-BD
AC AC AC AC AC
D D D D D1
R T2 R T2 T1
FX1N -1DA-BD
* Ver.2.00 or later
3
Interface Board FX1N -CNV-BD
Accessories
n Software
GX Developer GX Works2 FX
MITSUBISHI
WR PROTEC T SW ON O FF 8L PLC
n Interface Converters
n Display Modules
ES C
OK
FX1N -5DM
RD
8L
PLC
FX1N -EEPROM-8L
n Memory Cassette
158
Conguration Rules
CAUTION: For full configuration details please refer to the respective hardware manuals. 1. Number of input/output points FX3U/FX3UC: The total number of combined input/output points and remote I/O points on CC-Link or AS-i system must be 384 points
or less on the whole system, where the number of local I/O points and remote I/O points cannot exceed 256 points. system, where the maximum number of local I/O points and remote I/O points cannot exceed 128 points.
FX3G: The total number of combined input/output points and remote I/O points on CC-Link must be 256 points or less on the whole
FX3U
Special adapter (analog)
Up to 4 units
Up to 2 units
Up to 2 units
Up to 2 units
Only 1 unit
When an expansion board other than FX3U-CNV-BD is used, only 1 adapter can be connected.
FX3UC
Special adapter (analog) Special adapter (communication) Main unit Input/output extension block Special function unit Special function unit
Up to 4 units
Up to 2 units
Up to 8 units
FX3G
FX3G Main Units (40/60 Point Type)
Special adapter (analog) Special adapter (communication) Expansion board Main unit 40/60 point type Input/output powered extension unit Extension power supply unit Special function block
Up to 2 units
Up to 2 units
Up to 2 units
Up to 2 units
Only 1 unit
Up to 8 units
Only 1 unit
Only 1 unit
Only 1 unit
Up to 2 units
Only 1 unit
Up to 8 units
3. Calculation of current consumption FX3U / FX3UC / FX3G: The power is supplied to each connected device from the built-in power supply of the main unit, the input /
output powered extension unit or the extension power supply unit. There are three types of built-in power supplies; 24VDC service power, 5VDC power and internal 24VDC power. The power consumed varies depending on the type of product added.
Special adapter
Expansion board
Main unit
Note: FX3S/FX1S controllers can generally be considered as standalone controllers so no explicit configuration requirements exist. However, for configuration of adapters, boards, and memory cassettes, etc. please refer to the FX3S/FX1S hardware manual.
29 sequence instructions, 2 step 29 sequence instructions, ladder instructions, 116 applied 2 step ladder instructions, instructions 123 applied instructions
Step ladder, instruction list, SFC Step ladder, structured text, simple ladder, function block Cyclical execution, refresh mode processing 8 character keyword with 3 protection levels each (*1) 2 different keywords, maximum password length 16 characters 8 or 16-character keyword protection with 3 protection levels each (*1)
Auxiliary Relays
Timers
64 total, with 31 points partially switchable between 100ms and 10ms (T32 - T62) 2 32 total (16 - bit only), with 16 general (C0 - C15) and 16 latched (C16 - C31) 1 phase, 6 points max: 60 kHz / 2 points, 10 kHz / 4 points ; 2 phase, 2 points max: 30 kHz / 1 point, 5 kHz / 1 point
Counters
High-Speed Counters
21 total, with 16 1-phase (C235 - C250) and 5 2-phase (C251 - C255) 1 phase, 6 points max: 60 kHz/ 4 points, 10 kHz / 2 points 2 phase, 3 points max: 30 kHz/ 2 points, 5kHz/1 point 8,000 total, with 128 general (D0 - D127), 972 EEPROM latched (D128 - D1099), and 6,900 general/optional latched (D1100 - D7999) 24,000(R0~R23999) 24,000(ER0~R23999) internal/optional memory 1 phase, 8 points max: 100 kHz/ 6 points; 10 kHz / 2 points 2 phase, 2 points max: 50 kHz/ 2 points
Real-Time Clock
256 total, with 128 general (D0 - D127) and 128 latched (D128 - D255) 16 256 (D8000 - D8255) 64 8 6
Year, month, day, hour, minute, second, day of the week 3,000 total, with 128 general (D0-D127), 128 EEPROM latched (D128-D255), 2,744 general (D256-D2999) 8,000 total, with 200 general (D0 - D199), 312 optional latched (D200 - D511), and 7,488 latched (D512 - D7999) 32,768(R0~R32767) 32,768(ER0~R32767) optional memory
Data Registers
Extension Registers Extension File Registers Index Registers Special Data Registers Pointers Nestings Interrupt Inputs Constants
Note: 1. 8-character keyword protection level depends on the keyword registered; 16-character keyword protection level is set within GX-Developer
160
Environmental Specications
Model Number Ambient Temperature Noise Durability Dielectric Withstand Voltage Ambient Relative Humidity Shock Resistance Vibration Resistance Insulation Resistance Ground FX1S FX3S FX3G / FX3GE 0 - 55 C (storage 0 - 55 C (storage temperature: -25 to +75 C) temperature: -20 to +70 C) 1000 Vpp with noise generator; 1 s at 30 - 100 Hz AC PSU: 1500VAC, 1 min. / DC PSU: 500VAC, 1 min. AC PSU: 1500VAC, 1 min. AC PSU: 1500VAC, 1 min. / DC PSU: 500VAC, 1 min. 500VAC, 1 min. FX3U FX3UC
35 - 85% (non-condensing) 5 - 95% (non-condensing) Complies to IEC 68-2-27: 147 m/s (3 times each in 3 directions for 11 ms) Complies to IEC 68-2-6: 9.8 m/s (resistance to vibrations from 57 - 150 Hz for 80 minutes along all 3 axes); 4.9 m/s for DIN rail mounting 500VDC, 5M Class D: Grounding resistance 100 or less AC models: 250V 1.0A; DC models: 250V 0.8A For FX3G-14M and FX3G_-24M AC: 250V 1A; DC: 250V 3.15A For FX3G_-40M_ and FX3G-60M_: 250V 3.15A From FX3U-16M_ to FX3U-32M_ 250V 3.15A; From FX3U-48M_ to FX3U-128M_: 250V 5A
Fuse
250V 1A
125V 3.15A
Environment
Electrical Specifications
Power Supply Specifications FX1S AC Powered Models (FX1SM -ES/UL) FX1S DC Powered Models (FX1S_M_-DS/-DSS) FX3S AC Powered Models (FX3S-_M_/ES/ ESS) 100-240VAC (+10% / -15%), 50/60 Hz FX3GE AC Powered Models (FX3G__M_/ES/ESS) 100-240VAC (+10% / -15%), 50/60 Hz FX3GE DC Powered Models (FX3G__M_/DS/DSS) 24VDC (+20% / -15%) FX3U AC Powered Models (FX3U_M_ES/ESS) 100-240VAC (+10% / -15%), 50/60 Hz 30A / <5 ms (at 100VAC); 65A / <5 ms (at 200VAC) 10 ms FX3U DC Powered Models (FX3U_M_/DS/DSS) 24VDC (+20% / -30%) FX3UC
Power Supply
100-240VAC 24VDC (+10% / -15%), (+10% / -15%) 50/60 Hz (10%) 15A / 5 ms (at 10A / 0.1 ms (at 100VAC); 25A / 5 24VDC) ms (at 200VAC) 10 ms 5 ms
24VDC (+20% /-15%) Ripple Voltage (p-p) 5% or less 30A / < 0.5ms (at 24VDC) 5 ms
30A / <5 ms 15A / 5ms (at (at 100VAC); 100VAC); 28A / 50A / <5 ms (at 5ms (at 200VAC) 200VAC) 10 ms 10 ms
400 mA
400 mA
Output Specifications
FX3UC FX3U Triac Relay Models Models 85 242VAC 0.3 0.8 15VA / 100VAC 30VA / 240VAC <240VAC, <30VDC 2 8
FX3UC Transistor Models 5 - 30VDC 0.3A (Y0 - Y3), and 0.1A (Y4 or higher) 0.8 12W (7.2W per point for Y0 - Y3 and 2.4W per point for Y4 or higher) < 0.2 (< 5s for Y0, Y2)
0.5 0.8
0.5 0.8
0.5 0.8
0.5 0.8
80VA
12W
80VA
12W
80VA
12W
80VA
12W
80VA
0.2
0.2
< 0.2 (< 5s for 10 Y0, Y1) (*4) 3,000,000 at 20VA; 1,000,000 at 35VA; 200,000 at 80VA (*2)
1 ms
- (*3)
Notes: 1. This limitation applies to the maximum output current for each reference terminal (Common), each serving 1 to 4 relay or transistor outputs. Please observe the reference terminal assignments for group identification. 2. Not guaranteed by Mitsubishi Electric. 3. Refer to the specifications of the Terminal Block being used. 4. The 40 and 60 I/O pints main units supports 0.5s for Y2.
162
FX3UC
FX3UC Main Units with 16 - 96 I/O
Model Number Stocked Item Rating Integrated Inputs/Outputs Integrated Inputs Input Type Integrated Outputs Output Type Power Consumption (W) Weight (kg) Dimensions (W x H x D) mm FX3UC16MT/D FX3UC-16MT/ FX3UC-16MR/ FX3UCDSS DS-T 32MT/D S S FX3UC-32MT/ FX3UCDSS 64MT/D S S FX3UC-64MT/ FX3UCDSS 96MT/D UL cUL 16 8 Sink / Source 8 Relay 6 0.2 34 x 90 x 74 32 16 Sink 16 Transistor (Sink) 8 0.2 34 x 90 x 74 32 16 Sink / Source 16 Transistor (Source) 8 0.2 34 x 90 x 74 64 32 Sink 32 Transistor (Sink) 11 0.3 64 32 Sink / Source 32 Transistor (Source) 11 0.3 96 48 Sink 48 Transistor (Sink) 14 0.35 FX3UC-96MT/ DSS S UL cUL CE (EMC) 96 48 Sink / Source 48 Transistor (Source) 14 0.35
UL cUL CE (EMC) 16 8 Sink 8 Transistor (Sink) 6 0.2 34 x 90 x 74 16 8 Sink / Source 8 Transistor (Source) 6 0.2 34 x 90 x 74
FX3G
FX3G Main Units with 14 I/O
Model Number Stocked Item Rating Integrated Inputs/Outputs Power Supply (V) Integrated Inputs Integrated Outputs Output Type Power Consumption (W) Weight (kg) Dimensions (W x H x D) mm FX3G-14MR/DS S UL cUL CE (EMC) 14 24VDC 8 6 Relay 19 0.5 90 x 90 x 86 14 100-240VAC 8 6 Relay 31 0.5 90 x 90 x 86 14 24VDC 8 6 Transistor (Source) 19 0.5 90 x 90 x 86 14 24VDC 8 6 Transistor (Sink) 19 0.5 90 x 90 x 86 14 100-240VAC 8 6 Transistor (Source) 31 0.5 90 x 90 x 86 14 100-240VAC 8 6 Transistor (Sink) 31 0.5 90 x 90 x 86 FX3G-14MR/ES S FX3G-14MT/DSS S FX3G-14MT/DS S FX3G-14MT/ESS S FX3G-14MT/ES S
164
FX3GE
FX3GE Main Units with 24 I/O
Model Number Stocked Item Rating Integrated Inputs/Outputs Integrated Inputs Input Type Integrated Outputs Output Type Power Consumption (W) Weight (kg) Dimensions (W x H x D) mm FX3GE-24MR/DS S UL cUL CE (EMC) 24 24VDC 14 10 Relay 32 0.6 130 x 90 x 86 FX3GE-24MR/ES S UL cUL CE (EMC) 24 100-240VAC 14 10 Relay 32 0.6 130 x 90 x 86 FX3GE-24MT/DSS S UL cUL CE (EMC) 24 24VDC 14 10 Transistor (Source) 32 0.6 130 x 90 x 86 FX3GE-24MT/DS S UL cUL CE (EMC) 24 24VDC 14 10 Transistor (Sink) 32 0.6 130 x 90 x 86 FX3GE-24MT/ESS S UL cUL CE (EMC) 24 100-240VAC 14 10 Transistor (Source) 32 0.6 130 x 90 x 86 FX3GE-24MT/ES S UL cUL CE (EMC) 24 100-240VAC 14 10 Transistor (Sink) 32 0.6 130 x 90 x 86
FX3S
FX3S Main Units with 10 - 14 I/O
Model Number Stocked Item Rating Integrated Inputs/Outputs Power Supply (V) Integrated Inputs Integrated Outputs Output Type Power Consumption (W) Weight (kg) Dimensions (W x H x D) mm FX3S-10MR/ES S UL cUL CE (EMC) 10 100 - 240VAC 6 4 Relay 19 0.3 60 x 90 x 75 10 100 - 240VAC 6 4 Transistor (Sink) 19 0.3 60 x 90 x75 10 100 - 240VAC 6 4 Transistor (Source) 19 0.3 60 x 90 x75 14 100 - 240VAC 8 6 Relay 19 0.3 60 x 90 x75 14 100 - 240VAC 8 6 Transistor (Sink) 19 0.3 60 x 90 x75 14 100 - 240VAC 8 6 Transistor (Source) 19 0.3 60 x 90 x75 FX3S-10MT/ES S FX3S-10MT/ESS S FX3S-14MR/ES S FX3S-14MT/ES S FX3S-14MT/ESS S
FX1S
FX1S Main Units with 10 - 14 I/O
Model Number Stocked Item Rating Integrated Inputs/Outputs Power Supply Integrated Inputs Integrated Outputs Output Type Power Consumption (W) Weight (kg) Dimen. (W x H x D) mm FX1S-10MR- FX1S-10MR- FX1S-10MTDS ES/UL DSS 10 24VDC 6 4 Relay 6 0.22 60 x 90 x 49 S 10 100 240VAC 6 4 Relay 19 0.3 60 x 90 x 75 S 10 24VDC 6 4 Transistor (Source) 6 0.22 60 x 90 x 49 UL cUL CE (EMC) 10 100 240VAC 6 4 Transistor (Source) 19 0.3 60 x 90 x 75 FX1S-10MTESS/UL S FX1S-10MT UL cUL 10 100 240VAC 6 4 Transistor (Sink) 19 0.3 60 x 90 x 75 FX1S-14MR- FX1S-14MR- FX1S-14MTDS ES/UL DSS S 14 24VDC 8 6 Relay 6.5 0.22 60 x 90 x 49 S 14 100 240VAC 8 6 Relay 19 0.3 60 x 90 x 75 S 14 24VDC 8 6 Transistor (Source) 6.5 0.22 60 x 90 x 49 UL cUL CE (EMC) 14 100 240VAC 8 6 Transistor (Source) 19 0.3 60 x 90 x 75 FX1S-14MTESS/UL S FX1S-14MT S UL cUL 14 100 240VAC 8 6 Transistor (Sink) 19 0.3 60 x 90 x 75
BY0+BY0-BY1+BY1FX1N-2EYT-BD
The FX1N Series extension boards are available for the FX1S main units and add 4 inputs or 2 outputs to the system
FX1N-4EX-BD S UL cUL CE (EMC) FX1S 4 5VDC (from main unit); 24VDC / 25 mA (S/S terminal) 4 24VDC (+20% / -15%) 5 mA (24VDC) 0.02 43 x 38.5 x 22 FX1S 2 5VDC (from main unit) 2 Transistor 5 - 30VDC 0.02 43 x 38.5 x 22 FX1N-2EYT-BD S
166
The FX2N Series extension units are available with up to 48 integrated I/O with selectable relay or transistor output models.
Model Number Stocked Item Rating Applicable PLCs Integrated Inputs / Outputs Power Supply AC Range (+10%, -15%) External Service Power Supply (24VDC) mA Power Supply Int. Bus (5VDC) mA Integrated Inputs Integrated Outputs Output Type ON Voltage (Max.) Max. Output Current Weight (kg) Dimensions (W x H x D) mm Per Output (A) Per 4 Outputs (A) FX2N-32ER-ES/UL S UL cUL CE (EMC) FX3U / FX3G / FX3GE 32 100-240VAC 250 690 16 (24VDC) 16 Relay 2 8 0.65 150 x 90 x 87 32 100-240VAC 250 690 16 (24VDC) 16 Transistor (Source) 0.5 0.8 0.65 150 x 90 x 87 48 24VDC 690 16 (24VDC) 24 Relay 2 8 0.85 182 x 90 x 87 48 100-240VAC 460 690 16 (24VDC) 24 Relay 2 8 0.85 182 x 90 x 87 48 100-240VAC 690 24 (120VDC) 24 Relay 2 8 1.0 220 x 90 x 87 FX2N-32ET-ESS/UL S FX2N-48ER-DS CE FX2N-48ER-ES/UL S UL cUL CE (EMC) FX2N-48ER-UA1/UL S
Model Number Stocked Item Rating Applicable PLCs Integrated Inputs / Outputs Power Supply External Service Power Supply (24VDC) mA Power Supply Int. Bus (5VDC) mA Integrated Inputs Output Type ON Voltage (Max.) Max. Output Current Weight (kg) Dimensions (W x H x D) mm Per Output (A) Per 4 Outputs (A)
FX2N-48ET FX3U / FX3G / FX3GE 48 100-240VAC 460 690 24 (24VDC) Transistor (Sink) 0.5 0.8 0.85 182 x 90 x 87
FX2N-48ET-DSS CE 48 24VDC 690 24 (24VDC) Transistor (Source) 0.5 0.8 0.85 182 x 90 x 87
FX2N-48ET-ESS/UL UL cUL CE (EMC) 48 100-240VAC 460 690 24 (24VDC) Transistor (Source) 0.5 0.8 0.85 182 x 90 x 87
IN
The FX2N Series 8 - 16 integrated I/O extension blocks are selectable with relay, transistor or triac outputs.
FX2N-8ER-ES/UL S UL cUL CE (EMC) FX3U / FX3UC / FX3G / FX3GE 8 4 (24VDC) 4 Relay 2 8 25 0.2 43 x 90 x 87 8 8 (24VDC) 25 0.2 43 x 90 x 87 8 8 (100-120VAC) 25 0.2 43 x 90 x 87 8 8 Relay 2 8 30 0.2 43 x 90 x 87 8 8 Transistor (Sink) 0.5 0.8 30 0.2 43 x 90 x 87 8 8 Transistor (Source) 0.5 0.8 30 0.2 43 x 90 x 87 8 8 Relay 2.0 Isolated (commons) 30 0.3 40 x 90 x 87 All modular extension units are powered by the base unit FX2N-8EX-ES/UL S FX2N-8EX-UA1/UL FX2N-8EYR-ES/UL FX2N-8EYT S UL cUL S UL cUL CE (EMC) S FX2N-8EYT-ESS/ UL S UL cUL FX2N-8EY-S-ES/UL S UL
Model Number Stocked Item Rating Applicable PLCs Integrated Inputs / Outputs Power Supply Integrated Inputs Integrated Outputs Output Type ON Voltage (Max.) Max. Output Current Weight (kg) Dimensions (W x H x D) mm Per Output (A) Per 4 Outputs (A)
FX2N-16EYR-ES/UL S
FX2N-16EYS S UL cUL
FX3U / FX3UC / FX3G / FX3GE 16 16 (24VDC) 45 0.3 40 x 90 x 87 16 16 Relay 2 8 40 0.3 40 x 90 x 87 16 16 Triac (SSR) 0.3 0.8 160 0.3 40 x 90 x 87 All modular extension units are powered by the base unit
Relay version: < 240VAC, < 30VDC; Transistor version: 5 - 30VDC; Triac version: 85 - 242VAC
The FX2NC Series extension blocks are available with 16 or 32 integrated I/O with selectable relay or transistor 16-output models.
FX2NC-16EX-DS S FX2NC-16EX-T-DS S FX2NC-16EYR-T-DS FX2NC-16EYT-D/UL FX2NC-16EYT-DSS FX2NC-32EX-DS FX2NC-32EYT-D/UL S S UL cUL 16 16 Relay 2 4 50 0.15 24.2 x 90 x 89 16 16 Transistor (Sink) 0.1 0.8 30 0.15 14.6 x 90 x 87 S UL cUL CE (EMC) 16 16 UL cUL CE 32 32 (24VDC) UL cUL 32 32 Transistor (Sink) 0.1 0.8 100 0.2 26.2 x 90 x 87
UL cUL CE (EMC) FX3UC 16 16 30 0.15 14.6 x 90 x 87 16 16 30 0.15 20.2 x 90 x 89 All modular extension units are powered by the base unit
FX Analog Options
Analog Setpoint
FX1N-8AV-BD
The analog setpoint boards provide 8 analog setpoint potentiometers to the FXsystem. Setpoints can be polled by the PLC and used as default values for timers, counters and data registers.
Model Number Stocked Item Rating Applicable PLCs Power Supply Analog Channels (Inputs) Related I/O Points Weight Dimensions (W x Hx D) mm FX1N-8AV-BD S CE (EMC) FX1S 5VDC from main unit 8-bit 0 0.02 43 x 38.5 x 22 8-bit 0 0.02 35 x 51 x 12 8-bit 0 0.02 19.7 x 46.1 x 53.5 FX3G / FX3GE / FX3S FX3U FX3G-8AV-BD S FX3U-8AV-BD S
168
FX3U -4AD-ADP
POWER
Model Number Stocked Item Rating Applicable PLCs Power Supply Analog Channels (Input) Analog Range Resolution Voltage Current
FX1N-2AD-BD S CE (EMC) FX1S 5VDC (from main unit) 2 0 to 10VDC / 4 - 20 mA 2.5 mV (12 bit) 8 A (11 bit) 1% 0 0.02 43 x 38.5 x 22
FX3G-2AD-BD S FX3G / FX3GE / FX3S 5VDC (from main unit) 2 0 to 10VDC / 4 - 20 mA 2.5 mV 8 A (11 bit) 1% 0 0.02 35 x 51 x 29.2
FX3U-4AD-ADP S UL cUL CE (EMC) FX3U / FX3UC / FX3G / FX3GE / FX3S 5VDC / 15 mA (from main unit) 24VDC / 40 mA 4 0 to 10VDC / 4 - 20 mA 2.5 mV (12 bit) 10 A (11 bit) 0.5% to 1% (*1) 0 0.1 17.6 x 90 x 89.5
FX3U-4AD S FX3U / FX3UC / FX3G / FX3GE 5VDC / 110 mA (from main unit) 24VDC / 90 mA 4 -10 to 10VDC / -20 to +20mA / 4 to 20 mA DC 0.32 mV (15 bit + sign) 1.25 A (14 bit + sign) 0.3 to 1% fullscale (*1) 8 0.2 55 x 90 x 87
FX3UC-4AD FX3UC 5VDC / 100 mA (from main unit) 24VDC / 80 mA 4 -10 to 10VDC / -20 to +20mA / 4 to 20 mA DC 0.32 mV (15 bit + sign) 1.25 A (14 bit + sign) 0.3 to 1% fullscale (*1) 8 0.13 20.2 x 90 x 89
Model Number Stocked Item Rating Applicable PLCs Power Supply Analog Channels (Input) Analog Range Resolution Voltage Current
FX2N-4AD S
FX2NC-4AD S FX3UC 5VDC / 50 mA (from main unit) 24VDC / 130 mA 4 -10 to 10VDC / -20 to 20mA DC / 4 to 20mA DC 0.32 mV (15 bit + sign) 1.25 A (14 bit + sign) 0.3% - 0.5% (*1) 0.5 - 1.0% (*1) 8 0.13 20.2 x 90 x 89
FX2N-8AD (*2) S FX3U / FX3UC / FX3G / FX3GE 5VDC / 50 mA (from main unit) 24VDC / 80 mA 8 -10 to 10VDC / -20 to 20mA DC / 4 to 20mA DC 0.63 mV (14 bit + sign) 2.5 A (13 bit + sign) 0.3 - 0.5% (*1) 8 0.4 75 x 90 x 75
FX3U / FX3UC / FX3G / FX3GE 5VDC / 20 mA (from main unit) 24VDC / 50 mA (from main unit) 2 0 to 10VDC / 0 to 5VDC / 4 to 20mA DC 2.5 mV (12 bit) 4 A (12 bit) 1% 8 0.2 43 x 90 x 87 5VDC / 30 mA (from main unit) 24VDC / 55 mA 4 -10 to 10VDC / -20 to 20mA DC / 4 to 20mA DC 5 mV (11 bit + sign) 20 A (10 bit + sign) 1% 8 0.3 55 x 90 x 87
Overall Accuracy Voltage for Fullscale Current Related I/OPoints Weight (kg) Dimensions (W x H x D) mm
Notes: 1. Dependent on the ambient temperature. 2. The FX2N-8AD can be configured to accept standard analog inputs as well as selected temperature inputs such as K, T or J type thermocouples.
COM4
I4+
V4+
COM3
I3+
V3+
COM2
FX1N-2AD-BD
I2+
V2+
COM1
Analog Input
Analog input modules can provide up to 8 analog inputs that are used to convert analog voltage or current signals into digital values which can be used by the FX PLC.
I1+
V1+
24-
24+
FX3U -4DA-ADP
POWER
Analog Output
FX1N-1DA-BD
Analog output modules provide up to 4 analog outputs that are used to convert digital values in the PLC to voltage or current signals.
Model Number Stocked Item Rating Applicable PLCs FX1N-1DA-BD S CE (EMC) FX1S 5VDC (from main unit) 1 0 to 10VDC / 4 to 20mA DC 2.5 mV (12 bit) 8 A (11 bit) 1% 0 0.02 43 x 38.5 x 22 FX3G /FX3GE / FX3S 5VDC (from main unit) 1 0 to 10VDC / 4 to 20mA DC 2.5 mV (12 bit) 8 A (11 bit) 1% 0 0.02 35 x 51 x 29.2 FX3G-1DA-BD S FX3U-4DA-ADP S FX3U-4DA S FX2N-2DA S FX3U / FX3UC / FX3G / FX3GE 5VDC / 30 mA (from main unit) 24VDC / 85 mA (from main unit) 2 0 to 10VDC / 0 to 5VDC / 4 to 20mA DC 2.5 mV (14 bit) 4 A (12 bit) 8 0.2 43 x 90 x 87 FX2N-4DA S FX3U / FX3UC / FX3G / FX3GE 5VDC / 30 mA (from main unit) 24VDC / 200 mA 4 0 to 10VDC / 0 to 20mA DC / 4 to 20mA DC 5 mV (11 bit + sign) 20 A (10 bit + sign) 1% (*1) 8 0.3 55 x 90 x 87
FX2NC-4DA S
UL cUL CE (EMC) FX3U / FX3UC / FX3U / FX3UC / FX3G / FX3GE / FX3G / FX3GE / FX3S FX3S 5VDC / 15 mA (from main unit) 24VDC / 150 mA 4 0 to 10VDC / 4 to 20mA DC 2.5 mV (12 bit) 4 A (12 bit) 5% - 1% (*1) 0 0.1 17.6 x 90 x 89.5 5VDC / 120 mA (from main unit) 24VDC / 160 mA 4 -10 to 10VDC / 0 to 20mA / 4 to 20mA DC 0.32 mV (15 bit + sign) 0.63 A (15 bit) 8 0.2 55 x 90 x 87
FX3UC 5VDC / 30 mA (from main unit) 24VDC / 130 mA 4 -10 to 10VDC / 0 to 20mA DC / 4 to 20mA DC 5 mV (11 bit + sign) 20 A (10 bit + sign) 0.5% -1% (*1) 8 0.13 24.2 x 90 x 89
Power Supply Analog Channels (Output) Analog Output Range Voltage Current
Resolution
Overall Accuracy for Fullscale Related I/O Points Weight (kg) Dimensions (W x H x D) mm
Combination analog input / output modules are used for both digital to analog and analog to digital conversion.
FX2N-5A* S UL cUL CE (EMC) FX3U / FX3UC / FX3G / FX3GE 5VDC / 70 mA (from main unit) 24VDC / 90 mA 4 1 -10 to 10 V (15 bit + sign) -100 to 100 mV (11 bit + sign) -20 to 20 mVDC (14 bit + sign) 4 to 20 mA DC(14 bit) -10 to 10VDC (12 bit) 0/4 to 20 mA DC(10 bit) 0.3 - 1% 8 0.3 55 x 90 x 87 FX3U-3A-ADP S UL cUL
FX2N -5A
24 V AD / DA
FX3U / FX3UC / FX3G / FX3GE / FX3S 5VDC / 20 mA (from main unit) 24VDC / 90 mA 2 1 0 to 10VDC (12 bit) 4 to 20 mA DC (12 bit) 0 to 10VDC 4 to 20 mA DC 0.5 - 1% 0 0.1 17.6 x 90 x 89.5
5VDC / 30 mA (from main unit) 24VDC / 90 mA (from main unit) 2 1 0 to 10VDC (8 bit); 0 to 5VDC (8 bit) 4 to 20 mA DC(8 bit) 0 to 10VDC (8 bit); 0 to 5VDC (8 bit) 4 to 20 mA DC(8 bit) 1% 8 0.2 43 x 90 x 87
Overall Accuracy for Fullscale Related I/O Points Weight (kg) Dimensions (W x H x D) (mm)
Note: 1. When attaching the FX0N-3A or FX2N-5A analog modules to an FX3UC main unit, the FX2NC-CNV-IF interface adapter or the FX3UC-1PS-5V power supply unit is required.
170
COM4
I4+
V4+
COM3
I3+
V3+
COM2
I2+
V2+
COM1
I1+
V1+
24-
24+
The analog temperature input modules are used for J and K type thermocouple and Pt100 temperature sensor input and temperature control. 2 open collector transistor outputs are available with the FX2N-2LC, 4 with the FX3U-4LC.
Model Number Stocked Item Rating Applicable PLCs Power Supply FX3U-4AD-PTWADP FX3U-4AD-PTADP S FX3U-4AD-PNKADP FX3U-4AD-TCADP S FX2N-4AD-TC S FX2N-4AD-PT S FX2N-2LC S
FX2N -4AD-TC
A/D
FX3U-4LC S FX3G / FX3GE / FX3U / FX3UC 5VDC / 160 mA (from main unit) 24VDC / 50 mA 4 points (Thermocouple and Pt100 sensor) -200 to +1300 4 transistor output points 0.1 or 1 0.3% - 0.7% (1 digit) (*1) 8 0.4 90 x 90 x 80
UL cUL CE(EMC) FX3U / FX3UC / FX3G / FX3GE / FX3S 5VDC / 15 mA (from main unit) 24VDC / 50 mA 5VDC / 15 mA (from main unit) 24VDC / 50 mA 5VDC / 15 mA (from main unit) 24VDC / 50 mA 4 (Pt1000 or Ni1000) -50 to +250 (Pt1000) -40 to +110 (Ni1000) -500 to +2500 (Pt1000) -400 to +1100 (Ni1000) 0.1 0.5% - 1% (*1) 0 0.1 17.6 x 90 x 89.5 5VDC / 15 mA (from main unit) 24VDC / 45 mA 4 (J or K type) -100 to +600 (J type) -100 to +1000 (K type) -1000 to +6000 (J type) -1000 to +10000 (K type) 0.3 (J type) 0.4 (K type) FX3U / FX3UC 5VDC / 40 mA (from main unit) 24VDC / 60 mA 4 (J or K type) -100 to +600 (J type) -100 to +1200 (K type) FX3U / FX3UC / FX3G / FX3GE 5VDC / 70 mA 5VDC / 30 mA (from main (from main unit) unit) 24VDC / 24VDC / 50 mA 55 mA 2 points 4 (Pt100 (Thermocouple sensors) and Pt100 sensor) -100 to +600 -200 to +1300 2 transistor output points 0.1 or 1 0.3% - 0.7% (1 digit) (*1) 8 0.3 55 x 90 x 87
Analog Inputs
Compensated Temperature Range (C) Digital Outputs Resolution (C) Overall Accuracy for Fullscale Related I/O Points Weight Dimensions (W x H x D) mm
-100 to +600
-50 to +250
-1000 to +6000 (J type) -1000 to -1000 to +6000 +12000 (K type) 0.3 (J type) 0.2 - 0.3 0.4 (K type)
0.5% - 1% (*1) 0.5% - 1% (*1) 1.0% 0 0.1 17.6 x 90 x 89.5 8 0.3 55 x 90 x 87 8 0.3 55 x 90 x 87
FX3U-4HSX-ADP
POWER
X0/3
These high-speed modules provide additional counting and pulse output features to the PLC.
FX2NC-1HC FX3U-2HC S FX3U-4HSX-ADP S S
FX3U-2HSY-ADP
200 kHz
Input Format Type of Counter Output Format Counting Range (Up/Down and Ring Counter) Output Type Related I/O Points Dimensions (W x H x D) mm
less than 25 mA 4 (2 output points occupied per high-speed output) 17.6 x 90 x 89.5
SG SG
X6/7
X2/5
X1/4
FX2N -1HC
1-Axis Positioning
POWER ERROR
The FX3U-1PG and FX2N-10PG positioning modules are extremely efficient single-axis positioning modules for controlling either step drives or servo drives (by external regulator) with a pulse train.
Model Number Stocked Item Rating Applicable PLCs Input Signal Level Signal Level Pulse Output CLR Signal FX3U-1PG S UL cUL CE (EMC) FX3U / FX3UC 24VDC / 40 mA 5 to 24VDC / 35 mA 5 to 24VDC / 20 mA 5VDC / 150 mA (from main unit) 1 Max. 100 kHz 8 0.2 43 x 90 x 87 Servo / stepper pulse control FX2N-10PG S
START DOG X0 X1
FX 2N-10PG
PGO FP RP CLR
Power Supply Accessible Axes Output Frequency Related I/O Points Weight (kg) Dimensions W x H x D (mm) Function
5VDC / 100 mA; 24VDC / 70 mA 5 to 24VDC / 25 mA 5 to 24VDC / 20 mA 5VDC / 120 mA (from main unit) 1 Max. 1 MHz 8 0.2 43 x 90 x 87 Advanced servo / stepper control
2-Axis Positioning
High-performance 2-axis positioning module featuring simultaneous and interpolated 2-axis positioning control. With its dedicated setup, monitor and testing software, FX Configurator-FP, all aspects of the servo system can be controlled.
FX3U -20SSC-H
Model Number Stocked Item Rating Applicable PLCs Number of Controllable Axes Related I/O Connectable Servo Amplifier Servo Bus Scan Cycle Method User Units Unit Magnification Positioning Range Positioning Speed Units Acceleration / Deceleration Process Starting Time Interpolation Function Power Supply Power Consumption Weight (kg) Dimensions (W x H x D) mm
FX3U-20SSC-H S UL cUL CE (EMC) FX3U / FX3UC 2 axes 8 MELSERVO MR-J3-B/MR-J3W-B/MR-J3-BS maximum 2 amplifiers can be connected; Standard cord length: Station-to-station maximum 20m, Long distance cord length: Station-to-station maximum 50m SSCNETIII 1.77 ms Increment / Absolute PLS, m, 10-4 inch, mdeg 1, 10, 100, and 1,000-fold -2,147,483,648 to -2,147,483,648 PLS Hz, cm/min, 10deg/min, inch/min Trapezoidal acceleration/deceleration, S-pattern acceleration/deceleration: 1 to 500 ms. Only trapezoidal acceleration/deceleration is available for interpolation 1.6 ms or less 2-axis linear interpolation, 2-axis circular interpolation 24VDC + 20% -15% Ripple (p-p) within 5% 5W 0.3 55 x 90 x 87
Cam Switch
The FX2N-1RM-E-SET is often called an electronic cam module. It can be used to replace a mechanical camming system with a virtual electronic cam sequence using a resolver module.
Model Number Stocked Item Rating Applicable PLCs Number of Controllable Axes Maximum Connectivity Number of Cam Output I/O Control Resolution Response ON/OFFFrequency Resolver Maximum Cable Length Power Supply Related I/OPoints Weight (kg) Dimensions (W x H x D) mm FX2N-1RM-E-SET S CE (EMC) FX3U / FX3UC 1 using resolver F2-720RSV 3 48 outputs (32 may be ON at one time) 1 revolution of 720 divisions (0.5 degrees) or 360 divisions (1 degree) 415 rpm with 0.5 degrees or 830 rpm with 1 degree 8 times per CAM profile 3000 rpm up to 100 m 24VDC (-15% to +10%); 300 mA (400 mA when 32 outputs are ON) 8 (*1) 0.5 55 x 111 x 97
Note 1: The number of related I/O points will always be 8, regardless of how many units are attached.
172
Serial Communication
RD
These communication expansion boards allow their respective FX main units to communicate with external devices and other FX main units over a variety of serial networks.
Model Number Stocked Item Rating Applicable PLCs Interface FX2N-232IF S CE (EMC) FX3G / FX3GE FX3U / FX3S RS-232 with RS-232 with RS-422 with 8 RS-232 with RS-485 with 9-pole D-SUB 9 pole D-SUB pole mini DIN 9 pole D-SUB USB (Mini B) terminal block connector connector connector connector 5VDC / 40 mA 5VDC / 15mA (from main 5VDC / 60 mA 5VDC / 60 mA 5VDC / 60 mA 5VDC (from main unit), (from main (from main (from main (from main unit), 30mA 24VDC / 80 unit) unit) unit) unit) (from PC USB mA connectors) 8 FX3U / FX3UC FX1S FX1S FX1S 0.3 55 x 90 x 87 0.02 0.02 19.6 x 46.1 x 43 x 38.5 x 22 43 x 38.5 x 20 43 x 38.5 x 22 35 x 51 x 17.2 53.5 0.01 0.02 0.2 FX3G / FX3GE FX3G / FX3GE / FX3S / FX3S RS-422 with 8 pole mini DIN RS-485 connector 5VDC (from main unit) 0.2 5VDC (from main unit) 0.2 FX1N-232-BD S FX1N-422-BD S FX1N-485-BD S FX3G-232-BD S FX3U-USB-BD FX3G-422-BD S S FX3G-485-BD S
SD
FX3G-485-BDRJ (*1) S FX3G / FX3GE / FX1S RS-485 with RJ-45 connector 5VDC (from main unit) 0.2
These communication special adapters support a wide range of serial communication standards including Modbus.
FX3U-232ADP-MB S
FX3U -232ADP-MB
FX3U -485ADP-MB
POWER
POWER RD SD
RD SD
FX3U / FX3UC / FX3G / FX3GE / FX3S 5VDC / 20 mA (from main unit) RS-485 Max. 115.2 kbps 500m 0 0.08 17.6 x 90 x 89.5 5VDC / 30 mA (from main unit) RS-232C Max. 115.2 kbps 15m 0 0.08 17.6 x 90 x 89.5
Networking Modules
Ethernet
The FX3U-ENET communication module enables 8 ports of simultaneous Ethernet communication with features such as peer-to-peer, email send/receive options, and program upload/download. (The FX2NC-ENET-ADP communication special adapter is an Ethernet interface supporting 10BASE-T communication.)
Model Number Stocked Item Rating Applicable PLCs Max. Data Transmission Power Supply Communication Cable Communication Protocol Related I/O Points Communication With Mail Server Maximum Transfer Rate Maximum Segment Length Weight (kg) Dimensions W x H x D (mm) FX3U-ENET S UL cUL CE (EMC) FX3U / FX3UC / FX3G / FX3GE 1023 words x 8 24VDC / 240 mA Ethernet with RJ45 connector MCProtocol, TCP / IP / UDP 8 SMTP / POP3 100 Mbps / 10 Mbps 100 m 0.3 55 x 90 x 87 FX3U / FX3UC / FX3G / FX3S 1023 words x 4 Supplied from PLC Ethernet with RJ45 connector MCProtocol, TCP / IP / UDP 0 100 Mbps / 10 Mbps 100 m 0.1 17.6 x 90 x 89.5 FX1S 16 words Supplied from PLC Ethernet with RJ45 connector 8 0.1 19 x 90 x 78 FX3U-ENET-ADP S FX2NC-ENET-ADP S
SG
SDB
SDA
RDB
RDA
FX2NC-ENET-ADP
POWER
RD
10BASE-T/100BASE-TX
C1 C2 C3 C4 C5 C6 C7 C8
Profibus
PROFIBUS-DP allows for the implementation of decentralized control with comprehensive data and alarm processing capabilities. Easy setup is available by using the GX Configurator-DP software package.
Model Number Stocked Item Rating Applicable PLCs Master/Slave Power Supply Version Communication Speed Maximum Distance (*1) Maximum Number of Slaves Communication Distance (m) Communication Cable Related I/O Points Dimensions W x H x D (mm)
Note: 1. Depends on communication speed.
FX3U-64DP-M S UL cUL CE (EMC) FX3U / FX3UC Master Internal 24VDC / Max. 155 mA V 1.0 connector Max. 12 Mbps 1,200 m 64 / Master
FX3U-32DP S FX3U / FX3UC / FX3G / FX3GE Slave Internal 24VDC / 145 mA V 1.0 connector Max. 12 Mbps 1,200 m -
Max. 1200m (depends on communication speed) Profibus cable with Profibus-DP connector 8 43 x 90 x 89 8 43 x 90 x 89
CC-Link
FX3U-64CCL
FX2N-16CCL-M
CC-LINK
SW M/S PRM TIME LINE SD RD
DeviceNet
FX2N-64DNET
/TO MS NS
174
The FX Series interface boards enable connection of special adapters to the left side of the associated FX main unit. The FX2NC-CNV-IF interface adapter allows FX3UC main units to connect with the standard FX0N / FX2N / FX3U right side expansion bus.
Model Number Stocked Item Rating Applicable PLCs Description Weight (kg) Dimensions W x H x D (mm) FX3U-CF-ADP S CE (EMC) FX3U / FX3UC CF Card special adapter 0.3 45 x 90 x 74 FX3S Analog and communication special adapter 0.1 14.6 x 90 x 74 FX3G Analog and communication special adaptor 0.1 14.6 x 90 x 74 FX3U Analog and communication special adaptor 0.01 19.6 x 46.1 x 53.5 FX1S Function expansion board 0.01 43 x 38 x 14 FX3UC Interface adapter to connect with standard FX0N / FX2N / FX3U 0.3 90 x 14.6 x 74 FX3S-CNV-ADP S FX3G-CNV-ADP S FX3U-CNV-BD S FX1N-CNV-BD S FX2NC-CNV-IF S
The FXSeries power supply units are used to add power onto the 5V and 24V expansion buses when the built-in service power supplies are not sufficient.
Model Number Stocked Item Rating Applicable PLCs Input Voltage Input Frequency Inrush Current Power Consumption Output Current (Internal 24VDC for Supply) 5VDC Holding Time Weight (kg) Dimensions W x H x D (mm) FX3U-1PSU-5V S UL cUL CE (EMC) FX3U / FX3G 100 - 240VAC 50 / 60 Hz 30A max. 5 ms or less / 100VAC 65A max. 5 ms or less / 200VAC 20 VA max. 0.3A 1A 10 ms / 100VAC 0.3 55 x 90 x 87 FX3UC 24VDC +20% - 15% 30A max. 0.5 ms / 24VDC 25 W max. 1A 5 ms 0.15 24.2 x 90 x 74 FX3UC-1PS-5V FX3U -1PSU-5V
FX3UC-1PS-5V
POWER
The FX2N-20PSU 24VDC power supply unit is meant to provide a 24VDC power supply for DC powered FX main units, FX special function modules, sensors connected to the FX main units, etc.
Model Number Stocked Item Rating Applicable PLCs Ambient Temperature Ambient Relative Humidity (Non-Condensing) Input Voltage Input Frequency Fuse Rating Rush Current Output Power Ripple Noise Holding Time Protection Against Overcurrent Protection Against Overvoltage Weight (kg) Dimensions W x H x D (mm) FX2N-20PSU S UL cUL CE (EMC) FX1S / FX3U / FX3UC / FX3G / FX3GE 0 - 55C (-20 - 70C storage temperature) 35 - 85% (35 - 90% storage humidity) 100 - 240VAC 50/60 Hz 3.15A (built-in) 60A / 200VAC max. 24 DC 10% / 2A maximum; 0.2A minimum 500 mVp-p or less 10 ms / 100VAC Actuated when current becomes 110 - 160% or more, automatic recovery when voltage drop occurs Actuated when current becomes 110-140% or more, output shutdown, no automatic recovery (diode clamp) 0.3 60 x 98 x 75
MITSUBISHI
POWER
FX2N-20PSU
Accessories
Memory Cassettes
The Loader functionality allows the memory cassette to upload and download programs from and to the internal memory of the FX main units. When the memory cassette is attached to the FX main unit without uploading or downloading, the program on the memory cassette is executed. With the FX3U-FLROM-1M, 1.3MB of additional capacity is provided for symbolic information.
Model Number Stocked Item Rating Applicable PLCs Size Memory Type Protect Switch Data Transfer Buttons Dimensions W x H x D (mm) FX3U-FLROM-16 S CE (EMC) FX3U / FX3UC 16k steps Flash Provided Not Provided 37 x 20 x 6.1 64k steps Flash Provided Not Provided 37 x 20 x 6.1 64k steps Flash Provided Provided 37 x 20 x 6.1 64k steps +1.3MB Symbolic Flash Provided Not Provided 37 x 20 x 6.1 FX1S 2k / 8k steps EEPROM Provided Provided 33 x 30 x 9 FX3G / FX3GE / FX3S 32k steps EEPROM Provided Provided 35 X 21 X 9.6 FX3U-FLROM-64 S FX3U-FLROM-64L S FX3U-FLROM-1M S FX1N-EEPROM-8L S FX3G-EEPROM-32L S
Backup Batteries
Backup batteries provide enough power to store relevant data within the FX main units and modules when they are not powered.
Model Number Stocked Item Applicable PLCs FX3U-32BL S FX3U / FX3UC / FX3G / FX3GE FX1N-BAT S FX1S
Interface Converter
Model Number Stocked Item Rating Applicable PLCs Applications
Dimensions (W x H x D) mm
Terminal Blocks
Remote terminal blocks allow I/O modules to be placed at the point of control. The blocks are connected with FX3UC main units using connector-type I/O cabling.
Model Number Stocked Item Rating Applicable PLCs Max. Number of Inputs/Outputs Integrated Inputs (Sink) Integrated Outputs Output Type Switching Voltage (Max.) Max. Output Per Output (A) Current Per 4 Outputs (A) Dimensions (W x H x D) mm Model Number Stocked Item Rating Applicable PLCs Max. Number of Inputs/Outputs Integrated Inputs (Sink) Integrated Outputs Output Type Switching Voltage (Max.) Max. Output Per Output (A) Current Per 4 Outputs (A) Dimensions (W x H x D) mm FX-16E-TB FX3UC 16 16 (24VDC) 150 x 55 x 45 FX-16EYS-ES-TB/UL UL cUL FX3UC 16 output 16 Triac (SSR) 242VAC 0.3 0.8 150 x 55 x 45 FX-16E-TB/UL S UL cUL 16 16 (24VDC) FX-16EX-A1-TB 16 16 (120VAC) FX-16EX-A1-TB/UL 16 16 (120VAC) FX-16EYR-ES-TB/UL S UL cUL 16 output 16 Relay 240VAC / 30VDC 2 8
FX-16EYT-ESS-TB/UL FX-32E-TB/UL -
FX-TB40MIN S FX3U-2HC 40 80 x 87 x 76
32 32 (24VDC) -
176
Hand-Held Programmer
A small, industrial programming and maintenance tool for the FX Series. This unit can perform program uploads/downloads and store up to 15 programs in its internal memory. Keywords can be registered, deleted or canceled in applicable PLCs. Program monitoring and data device adjustment functionality is also available. To stay up to date the latest firmware can be downloaded on a PC then installed via the USB port. PLC programs on the PC can also be transferred via USB, eliminating the need for peripheral devices.
Model Number Stocked Item Rating Applicable PLCs Power Supply Display / Characters FX-30P S UL cUL CE FX1S / FX3U / FX3UC / FX3G / FX3GE / FX3S 5VDC / 155mA LED / 21 x 8 characters
Display Modules
Model Number Stocked Item Rating Applicable PLCs Display Resolution
Display modules are attached to the front face of the main unit and enable monitoring and adjustment of PLC data services.
FX3G-5DM S CE (EMC) FX3G LCD (with backlight) 16 characters x 4 lines 0.02 49.4 X 39.4 X12 FX3U-7DM S CE (EMC) FX3U LCD (with backlight) 16 characters x 4 lines 5VDC / 20 mA 0.02 48 x 35 x 11.5 FX3U-7DM-HLD S FX3U Included 0.01 66.3 x 41.8 x 13 FX1N-5DM S CE (EMC) FX1S LCD (with backlight) 5VDC 5% / 110 mA 0.02 40 x 32 x 17 FX-10DM-E S CE (EMC) FX1S / FX3U / FX3UC LCD (with backlight) 2 x 16 characters (80 x 16 pixels) 5VDC 5% / 220 mA 0.02 96 x 62 x 32
MITSUBISHI
ESC
OK
Power Supply (From Main Unit) Extension Cable Weight Dimensions W x H x D (mm)
Connection Cables
The cables listed in the following tables are used for FX Series PLC programming, positioning applications block connections and interface conversion.
Model Number Stocked Item Application Length (m) F2-RS-5CAB FX2N-1RM to resolver 5.0 FX-232CAB-1 S PC (RS-232) to GOT (RS-232) 3.0 SC09 S PC (RS-232) to PLC (RS-422) 3.0 GT09-C30USB-5P S PC (USB) to PLC (Mini USB) 3.0
FX3UC to remote FXterminal block 1.5 3.0 5.0 1.5 3.0 5.0
The Alpha2 is a controller designed to address simple control applications at the lower end of the industrial and commercial control markets. With simple analog processing integrated, a straightforward programming style and a built-in display, the Alpha2 is a highly affordable control solution Integrated analog processing Simple programming style Relay and Transistor output options Analog input and output options High-speed counters up to 1 kHz Language support for 7 different languages Display area for messages and function block data Built-in LCD screen for programming panel or operator interface functions Programming with Alpha VLS
Programming
Graphical function block style programming with drag and drop icons creates an intuitive environment for the user. The programming software also includes a simulation mode to allow off-line program testing without any hardware connected
The Alpha family has a calendar and clock with automatic summer and winter time switching.
Expansion
Four expansion boards are currently available 4 digital 24V DC inputs with two integrated counters, 4 digital 240V AC/DC inputs, 4 relay outputs and 4 transistor outputs.
Applications
The Alpha2 can be fitted to a range of lower end of the industrial and commercial control markets. Typical applications are listed below. Lighting control Heating ventilation and air conditioning (HVAC) Lighting Pump controllers Building automation Alarms and security systems
Product Details
All-in-one CPU, power supply, display and I/O. Expansion options include expansion boards for communication, high-speed counting or extra I/O.
Environmental Specifications
General Specifications Ambient Temperature Protection Rating Noise Immunity Dielectric Withstand Voltage Allowable Relative Humidity Shock Resistance Vibration Resistance Direct Mounting Alpha2 Display: -10 to 55C, Hardware: -25 to 55C (storage temperature: -30 to +70C) IP20 1000 Vpp with noise generator; 1s at 30 - 100 Hz, tested by noise simulator 3750VAC, >1 min. according to EN60730 35 - 85% (no condensation) Complies to IEC 68-2-27: 147 m/s acceleration, 11 ms 3 x 3 directions Complies to IEC-2-6: 19.6 m/s acceleration, 80 min. in each direction 500VDC, 7 M Complies to EN60730-1 No corrosive gasses, no dust DIN Rail Mounting Complies to IEC-2-6: 9.8 m/s acceleration, 80 min. in each direction
178
Electrical Specifications
Power Supply Specifications Power Supply Inrush Current at ON Allowable Momentary Power Failure Time Digital Inputs Input Voltage 24VDC (+20% / -15%) Sink: 5.5mA, 24VDC AL2-10MR-D (I01 - I06) AL2-14MR-D/AL2-24MR-D (I01 - I08/ I09 - I15) Source: 6.0mA, 24VDC AL2-10MR-D (I01 - I06) AL2-14MR-D/AL2-24MR-D (I01 - I08) Source: 5.5mA, 24VDC AL2-14MR-D/AL2-24MR-D (I09 - I15) Response Time OFF - ON ON - OFF 10 - 20 ms 10 - 20 ms 0-500 9 bit, (10 V/500) 8 0-10VDC 142 5% 5% (0.5VDC) 35-85 ms, 120VAC 25-55 ms, 240VAC 35-85 ms, 120VAC 50-130 ms, 240VAC 100-240VAC (+10% / -15%), 50/60 Hz I01-I08 0.13mA / 120VAC (*1) 0.25mA / 240VAC (*1) I09 - I15 0.15mA / 120VAC (*1) 0.29mA / 240VAC (*1) DC Powered Models (AL2-_MR-D) 24VDC (+20% / -15%) 7.0A (at 24VDC) 5 ms AC Powered Models (AL2-_MR-A) 100-240VAC (+10% / -15%), 50/60 Hz 6.5A (at 240VAC) 10 ms Output Specifications Type Switching Voltage (Max.) Rated Current Max. Switching Load Inductive Load Minimum Load Response Time Alpha2 Relay 250VAC, 30VDC 10M, 14M: 8A/com 24M (001-004): 8A/com 24M (005-009): 2A/point 14M, 24M: 249 VA/250VAC, 373 VA/250 24M: 93 VA/125VAC, 93 VA/250VAC 10mA, 5 V DC <10 ms
Input Current
Analog Inputs Analog Input Range Resolution Conversion Speed Input Voltage Input Impedance Accuracy
Note: 1. Current leakage from sensors connected to the inputs might provide enough current to turn the controller ON. Do not use 2-wire sensors.
Programming Specifications
System Specifications Programming Method Program Capacity Program Processing Number of Available Instructions Program Storage Data Storage Processing Time Real-Time Clock Program Protection Alpha2 Function block 200 function blocks or 5000 bytes Cyclic processing of the stored program 38 different function blocks Integrated EEPROM and optional additional EEPROM cassette At voltage loss the current status of values, running time meters, and real-time data are stored for up to 20 days (at temperatures of 0 to 25 C) using capacitors 1 ms + 20s /logic instruction (complex commands 500/s instruction) Seconds, minutes, hours, day of week, month, year (4-digit); accuracy: 5 s / day; automatic daylight savings time adjustment 3 levels using program and keys
V1+
V1-
V2+
V2-
POWER 24V DC
CH1
CH2
OUTPUT
0~10V
Expansion/adapter modules significantly increase the range of applications for the Alpha2. (Expansion modules are inserted directly into the Alpha2 and therefore do not take up any further space. The AL-2TC-ADP and AL2-2PT-ADP adapters are connected externally to the AL2.)
Model Number AL2-4EX* AL2-4EX-A2* AL2-4EYR* AL2-4EYT* AL2-2TC-ADP AL2-2PT-ADP AL2-2DA* Descriptions 4 digital inputs (24VDC) with 2 selectable high-speed counter (1kHZ) 4 digital inputs (240VAC) 4 relay outputs (2A) 4 transistor outputs (1A) 2 Channel TCInput Adapter Module 2 Channel PT Input Adapter Module 2 Channel Digital to Analog Expansion Module Stocked Item S S S S S UL cUL CE Rating
MITSUBISHI
V1+
I1+
VI1-
POWER 24V DC
ANALOG OUTPUT
POWER
ANALOG OUTPUT
V2+ I2+ VI2-
2DA
L1+
L1-
SLD L2+
L2-
SLD
*AL2 Expansion Cassettes cannot be used with AL2-10M** controllers due to size constraints.
The memory cassette allows the memory cassette to upload and download programs from and to the internal memory of the Alpha2. When the memory cassette is attached to the Alpha2 without uploading or downloading, the program on the memory cassette is executed.
MADE IN J APAN
Model Number Stocked Item Rating Memory Type Memory Size Number of Program Steps Non-Volatile Storage Write Protection
The AL2-ASI-BD in combination with an Alpha2 controller facilitates the data communications via an AS interface system. The AL2-ASI-BD is attached to an Alpha2 series module and forms a slave unit.
Model Number Stocked Item Rating Module Type Number of I/OPoints External Power Supply External Current Consumption Communication Protocol Weight Dimensions AL2-ASI-BD S UL cUL CE (EMC) Slave Module 4 inputs; 4 outputs 30.5VDC (AS-Interface power supply) Max. 40 mA AS-i standard 0.5 53.1 x 90 x 24.5
AL 2-E E P R O M
ASI+ASI-
The AL-232CAB is an RS-232C interface cable. It connects the Alpha2 controller to a personal computer running the programming software for the Alpha2 controller. The AL2-GSM-CAB is an RS-232C interface cable that enables the Alpha2 to connect to a GSM modem or other equipment including personal computer, graphic operator terminal, or other serial devices.
AL-232CAB
AL2-GSM-CAB S 9-pin D-SUB male connector GSM modem or other serial communication 1.5
AL2-GSM-CAB
180
Software
GX Works2
GX Works2, as part of iQ Works, is the next generation configuration and programming software for FX, L and iQ Platform / Q Series controllers. Following the goal of maximum efficiency, GX Works2 allows developers to mix and match between five different programming languages, each conforming to a different programming style. Developers can select their preferred language which is best suited for the application. This environment conforms to IEC1131-3 standards, also allowing parts of projects to be saved in Libraries for use within future applications.
Type Model Number GX-WORKS2-C1 GX-WORKS2-C5 Software GX-WORKS2-C10 GX-WORKS2-C25 GX-WORKS2-C50 GX-WORKS2-C100 GX-WORKS2-OEM GX-WORKS2-C1-SMA GX-WORKS2-C5-SMA SMA GX-WORKS2-C10-SMA GX-WORKS2-C25-SMA GX-WORKS2-C50-SMA GX-WORKS2-OEM-SMA Description Single User License of GX Works2 5 User License of GX Works2 10 User License of GX Works2 25 User License of GX Works2 50 User License of GX Works2 100 User License of GX Works2 OEM Site License of GX Works2 SMA for GX-Works2-C1 SMA for GX-Works2-C5 SMA for GX-Works2-C10 SMA for GX-Works2-C25 SMA for GX-Works2-C50 OEM-SMA Site License of GX Works2 Stock Status S S These are the part number to order an SMA for the GX Works2 part numbers. Updates will be provided electronically. These are the part numbers to use if a customer wants to purchase the GX Works2 programming software only, without the full iQ Works suite. Notes
GX Works2 FX
GX Works2 FX is a scaled down version of GX Works2 supporting FX Series PLCs. GX Works2 FX is completely compatible with the full version of GX Works2 making it easy to share programs between the two software packages (limited to FX PLC programs). Customers who already have GX Works2 or iQ Works do not need GX Works2 FX as all the functionality in GX Works2 FX is available in those software products. FX Configurator-EN, FX Configurator-FP, and helpful function blocks are included on the CD.
Type Model Number GX-WORKS2-FX-C1 GX-WORKS2-FX-C5 Software GX-WORKS2-FX-C10 GX-WORKS2-FX-C25 GX-WORKS2-FX-C50 GX-WORKS2-FX-C100 GX-WORKS2-FX-OEM Description Single User License of GX Works2 FX 5 User License of GX Works2 FX 10 User License of GX Works2 FX 25 User License of GX Works2 FX 50 User License of GX Works2 FX 100 User License of GX Works2 FX OEM Site License of GX Works2 FX Stock Status S GX Works2 FX only supports FX Series PLCs. Customers using FX in addition to Q or L Series CPUs should select the full version of GX Works2 or iQ Works. GX Works2 FX does not require an SMA, updates are available for all users for the entire life of the software. Notes
AL-PCS/WIN is the standard programming and documentation software for all Alpha Series controllers and provides an easy to use graphical programming environment. Program elements are placed on the function block diagram with visible wires to connect them and the I/O terminals. Monitoring functions with optional pictures of the uses application in the background are also available.
Model Number Series Language Applicable For AL-PCS/WIN Alpha Series 7 languages (English/German/French/Italian/Spanish/Swedish/Russian) Windows 95/98/ME/NT/2000/XP/Vista/Windows 7 (32bit and 64bit)
182