Thermistor Resistance Chart

ASU: 9RLQ, 12RLQ, 15RLQ, 18CL, 9/12RL, 9/12RLS, 18RLQ, 24CL, 24RLXQ, 30CLX, 36RLXQ, 36CLX, 18RLXS, 24RLXS, 30RLX AUU: 18, 24, 36, 42RCLX ABU: 18, 24RULX, 36RSLX AOU: AOU: AOU: AOU: AOU: 9RLQ, 12RLQ, 15RLQ, 18CL, 18RLQ 18, 24, 36, 42RLX 24, 36RML 24, 36RML1 9/12RL, 9/12RLS

AOU: 24CL, 24RLXQ, 30CLX, 30RLXQ, 36CLX AOU: 18, 24RLXS,30RLX 2/3 Way Valve Thermistor Ohms k Discharge/ Outdoor Outdoor Pipe Compressor Temperature Thermistor Thermistor Thermistor Ohms k Ohms k Ohms k 931.50 88.42 181.60 683.30 64.89 133.30 506.60 48.13 98.86 379.40 36.07 74.08 286.90 27.29 56.05 219.00 20.84 42.80 168.60 16.05 32.97 130.70 12.45 25.57 102.20 9.74 20.00 80.51 7.67 15.76 63.89 6.09 12.51 51.05 4.87 10.00 41.07 3.92 8.05 33.26 3.17 6.52 27.09 2.59 5.31 22.20 2.12 4.35 18.29 1.75 3.59 15.15 1.45 2.97 12.62 1.21 2.48 10.56 1.01 2.07 8.88 0.85 1.74 7.50 0.72 1.47 6.36 0.61 1.25 5.42 4.64 3.98 3.43 2.97 2.58 2.24 1.96

Room T Thermistor Temp F(C) -22(-30) -13(-25) -4(-20) 5(-15) 14(-10) 23(-5) 32(0) 41(5) 50(10) 59(15) 68(20) 77(25) 86(30) 95(35) 104(40) 113(45) 122(50) 131(55) 140(60) 149(65) 158(70) 167(75) 176(80) 185(85) 194(90) 203(95) 212(100) 221(105) 230(110) 239(115) 248(120) 284(140) 320(160) 356(180) Ohms k

Room T Thermistor w/ board Ohms k

Indoor Pipe Thermistor Ohms k

Indoor Pipe Discharge/ Outdoor Outdoor Pipe Heat Sink Thermistor Compressor Temperature Thermistor Thermistor w/ board Thermistor Thermistor Ohms k Ohms k Ohms k Ohms k Ohms k

33.62 25.93 20.18 15.84 12.54 10.00 8.04 6.51 5.30 4.35 3.59 2.98 2.47 2.09 1.76 1.49 1.27 1.09 0.93 0.81 0.70

8.29 7.12 5.86 5.24 4.64 3.58 2.71 2.03 -

176.03 134.23 103.34 80.28 62.91 49.70 39.57 31.74 25.64 20.85 17.06 14.10 11.64 9.69 8.12 6.83 5.78 4.91 4.19 3.59 3.09

39.48 34.10 28.14 25.15 22.26 17.05 12.78 9.47

175.70 134.93 104.59 81.79 64.50 51.27 41.07 33.13 26.91 22.01 18.10 14.98 12.47 10.44 8.78 7.42 6.31 5.38 4.61 3.97 3.43 2.98 2.59 2.26 1.99 1.21 0.77 0.51

49.20 36.58 27.51 20.91 16.05 12.44 9.73 7.67 6.10 4.89 3.95 3.21 2.62 2.16 1.79 1.49 1.25 1.05 0.89 0.76 0.65 0.56 0.48 0.41 0.36

115.24 84.21 62.28 46.58 35.21 26.88 20.72 16.12 12.64 10.00 7.97 6.40 5.18 4.21 3.45 2.85 2.36 1.97 1.65 1.39 1.18 1.00 0.85 0.73 0.63

16.1 12.4 9.73 7.67 6.10 3.95 2.62 1.79 1.25 0.89 0.65 0.48 0.36 0.27 0.21

312 233 176 134 103 80.3 62.9 39.6 25.6 17.1 11.6 8.12 5.78 4.19 3.09

Indoor Ceiling Cassettes


MODELS: AUU18RCLX, AUU24RCLX, AUU36RCLX, AUU42RCLX
Error Code 01 02 03 04 05 06 08 09 0A 0c 11 12 13 14 15 16 17 18 19 1A 1b 1c 1d 1E 1F Error Contents Indoor unit doesnt accept signal from outdoor unit Room temperature sensor open Room temperature sensor short-circuited Indoor heat exchanger temperature sensor open Indoor heat exchanger temperature sensor short circuited Outdoor heat exchanger temperature sensor Power source connection error Float switch operated Outdoor temperature sensor error Discharge pipe temperature sensor Model abnormal/Indoor EPROMAbnormal Indoor fan abnormal Outdoor unit doesnt accept the signal from indoor unit Excessive outdoor pressure (permanent stop) Compressor temperature sensor Pressure switch error IPMerror CTerror Active filter module (AFM) error Compressor does not operate Outdoor unit fan error Communication error (inverter to multi controller) 2 way valve sensor error Expansion valve error Connection indoor unit error

HIGH-SEER R410A MINI-SPLITS TROUBLESHOOTING GUIDE 2010 - 2011

Outdoor Cassette & Ceiling Suspended


MODELS: AOU18RLX, AOU24RLX, AOU36RLX, AOU42RLX
LED 1 flash 2 flash 3 flash 4 flash 7 flash 8 flash 9 flash 12 flash 13 flash 14 flash 15 flash 16 flash Lighting Error Contents Communication error (Indoor unit to Outdoor unit) Discharge pipe temperature sensor Outdoor heat exchanger temperature sensor Outdoor temperature sensor Compressor temperature sensor Heat sink temperature sensor Pressure switch abnormal IPMerror Compressor rotor position cannot detect Compressor cannot operate/Start up error Outdor fan abnormal (upper fan) Outdoor fan abnormal (lower fan) No error

FUJITSU GENERAL AMERICA, INC. 353 Route 46 West Fairfield, NJ 07004 (866) 952-8324 (973) 575-0381 Service Center Phone (973) 836-0449 Service Center Fax Email: ServiceHVAC@fujitsugeneral.com
Revision 10/10 Part #6-26-FG2020

Wall Mounted
MODELS: ASU9RLQ/AOU9RLQ, ASU12RLQ/AOU12RLQ, ASU15RLQ/AOU15RLQ, ASU18RLQ/AOU18RLQ, ASU24CL/ AOU24CL, ASU24RLXQ/AOU24RLXQ, ASU30CLX/AOU30CLX, ASU18RLXS/AOU18RLXS, ASU24RLXS/AOU24RLXS, ASU30RLX/AOU30RLX, ASU30RLXQ/AOU30RLXQ, ASU36CLX/AOU36CLX

Error Indication Operation Timer


0.5 sec 2 Times 0.5 sec 3 Times

Wired Remote

Error

Diagnosis Method
Communication error - At Start Up, Evaporator and Condenser are not communicating. -Check wiring from panel to condenser, condenser to evaporator. Wire nuts and splices are not recommended. Check for correct voltage at panel, condenser and evaporator. Refer to the Service Instruction manual - Serial Signal troubleshooting for further details. Communication error - During operation, Evaporator and Condenser did not communicate for 10 consecutive seconds. -Check wiring from panel to condenser, condenser to evaporator. Check for correct voltage at panel, condenser and evaporator. Refer to the Service Instruction manual - Serial Signal troubleshooting for further details. Communication error - At the start up, Evaporator and Condenser are not communicating. -Reset power. If error code reappears check wiring from panel to condenser, condenser to evaporator. Check for correct voltage at panel, condenser and evaporator. Refer to the Service Instruction manual - Serial Signal troubleshooting for further details. Communication error - During operation, Evaporator and Condenser did not communicate for 10 consecutive seconds. -Reset power. If error code reappears check wiring from panel to condenser, condenser to evaporator. Check for correct voltage at panel, condenser and evaporator. Refer to the Service Instruction manual - Serial Signal troubleshooting for further details. Communication error - Evaporator and wire remote controller are not communicating. -Check wiring between evaporator and wire remote controller. -Check for DC 12V at evaporator connector. If voltage present replace wire remote control. Room temperature thermistor detected an abnormal temperature. -Check thermistor for open or short. Check thermistor resistance value (Refer to Thermister characteristics table). -Controller PCB defective. Evaporator pipe thermistor detected an abnormal temperature. -Check thermistor for open or short. Check thermistor resistance value (Refer to Thermister characteristics table). -Controller PCB defective. Condenser discharge thermistor detected an abnormal temperature.

01 01 13 13 00 02 04 0C 06 0A 15

Serial reverse transfer error at start up operation Serial reverse transfer error during operation Serial forward transfer error at start up operation Serial forward transfer error during operation Wire Remote Controller error

OFF

0.5 sec 4 Times 0.5 sec 5 Times 0.5 sec 8 Times 0.5 sec 2 Times 0.5 sec 3 Times 0.5 sec 2 Times 0.5 sec 3 Times 0.5 sec 4 Times 0.5 sec 8 Times

Room temperature thermistor error Indoor heat exchanger thermistor error

0.5 sec 2 Times

Discharge thermistor error -Check thermistor for open or short. Check thermistor resistance value (Refer to Thermister characteristics table).
-Controller PCB defective.

0.5 sec 3 Times

Outdoor heat exchanger thermistor error

Condenser pipe thermistor detected an abnormal temperature. -Check thermistor for open or short. Check thermistor resistance value (Refer to Thermister characteristics table). -Controller PCB defective. Condenser ambient thermistor detected an abnormal temperature. -Check thermistor for open or short. Check thermistor resistance value (Refer to Thermister characteristics table). -Controller PCB defective. Condenser ambient thermistor detected an abnormal temperature. -Check thermistor for open or short. Check thermistor resistance value (Refer to Thermister characteristics table). -Controller PCB defective.

Outdoor temperature thermistor error Compressor Temperature Thermistor Error

Universal Mount / Ceiling Suspended


MODELS: ABU18RULX, ABU24RULX, ABU36RSLX Operation
Continuous blink Continous blink 2 flashes 2 flashes 3 flashes 3 flashes 4 flashes 5 flashes 5 flashes 6 flashes Continuous blink Continuous blink Continuous blink Continuous blink Continuous blink Continuous blink Continuous blink Continuous blink Continuous blink Continuous blink Continuous blink Continuous blink Continuous blink Continuous blink Continuous blink Continuous blink

Timer
Continuous blink Continuous blink Continuous blink Continuous blink Continuous blink Continuous blink Continuous blink Continuous blink Continuous blink Continuous blink 2 flashes 3 flashes 3 flashes 4 flashes 4 flashes 5 flashes 5 flashes 6 flashes 7 flashes 8 flashes 9 flashes 10 flashes 11 flashes 12 flashes 13 flashes 14 flashes

Swing
OFF Continuous blink OFF Continuous blink OFF Continuous blink OFF OFF Continuous blink OFF OFF OFF Continuous blink OFF Continuous blink OFF Continuous blink OFF OFF OFF OFF OFF OFF OFF OFF OFF Indoor EEPROMabnormal Outdoor EEPROM abnormal Indoor room temperature sensor open

Error Contents

Indoor room temperature sensor short circuited Indoor heat exchanger temperature sensor open Indoor heat exchanger temperature sensor short circuited Float switch operated Communication error (serial reverse transfer error) Outdoor communication error (forward reverse transfer error) Indoor fan abnormal Outdoor power source connection abnormal Outdoor heat exchanger temperature sensor open Outdoor heat exchanger temperature sensor short circuited Outdoor temperature sensor open Outdoor temperature sensor short circuited Outdoor discharge pipe temperature sensor or compressor temperature sensor open Outdoor discharge pipe temperature sensor or compressor temperature sensor short circuited Outdoor high pressure abnormal Outdoor discharge pipe temperature or compressor temperature sensor abnormal Compressor temperature thermistor error Pressure switch error IPM error CTerror Active Filter Module Error (AFM) Compressor rotor location can not be detected (Permanent Stop) Outdoor unit fan motor error

Wall Mounted
MODELS: ASU9RLQ/AOU9RLQ, ASU12RLQ/AOU12RLQ, ASU15RLQ/AOU15RLQ, ASU18RLQ/AOU18RLQ, ASU24CL/ AOU24CL, ASU24RLXQ/AOU24RLXQ, ASU30CLX/AOU30CLX, ASU18RLXS/AOU18RLXS, ASU24RLXS/AOU24RLXS, ASU30RLX/AOU30RLX, ASU30RLXQ/AOU30RLXQ, ASU36CLX/AOU36CLX

Error Indication Operation Timer


0.5 sec 2 Times 0.5 sec 3 Times

Wired Remote
No Display

Error

Diagnosis Method
Forced auto switch open (pushed in) for 30 consecutive seconds or more. -Check if forced auto switch is kept pressed. -Controller PCB defective. After 2 minutes 20 seconds of stopped operation, the signal from the outdoor unit is received even though the main relay is OFF. -Check if Main relay is defective. -Controller PCB defective. The power supply frequency can not be recognized after 4 seconds of Power ON. Permanent STOP. -Controller PCB defective. Electric Air Cleaner error - When the air cleanness monitor trial protection operates 4 times. -Check the front panel and ensure it is closed. -Check IAQ micro switch for open/close operation. IAQ error code - The air clean operation signal was detected for 1 minute at the time of air clean mode was OFF. -Electric air cleaner defective. -Controller PCB defective. Abnormal current value at the IPM is detected. Heat radiation is blocked (inlet/outlet). -Check if outdoor fan is defective (does not rotate). -IPM/Controller PCB defective.Check Refrigeration cycle for under/over charge conditions. Current Transfer error - The current value during the operation after 1 minute from starting up the compressor drops to zero (0) Amps. -Check if CT wire is open. See Service Manual for schematic on each model. -Controller PCB defective. Compressor Detection - The compressor speed does not synchronize with the control signal. (Including start up failure of the compressor.) -Check if 2-way valve or 3-way valve are open.Check the compressor (Winding resistance value, loose lead wire). -Check Refrigeration cycle condition. Condenser fan motor error - Abnormal current or fan motor lock error was detected. -Check Fan motor connector loose/defective contact. Rotate fan motor by hand to ensure it is not locked. Check DC 150-380V on fan motor between Red &Black wire. Check DC 15V between Black &White wire. Voltage not present. -Controller PCB defective.

Forced auto switch error

No Display

Main Relay error

0.5 sec 4 Times

0.5 sec 4 Times 0.5 sec 7 Times 0.5 sec 8 Times 0.5 sec 2 Times 0.5 sec 3 Times

No Display

Power supply frequency detection error VDD permanent STOP protection (electric air cleaner) Reverse VDD (Electric air clean power supply circuit abnormal) IPM protection

No Display

21

17

18

CT error

0.5 sec 5 Times

0.5 sec 5 Times 0.5 sec 6 Times 0.5 sec 7 Times

1A

Compressor location error

1B

Outdoor fan error (DCMotor)

1F

Model Match Error Apparent model information error from EPROM (miss match). 3 continuous failure of lead test of EPROM at PowerON, Connected indoor unit Voltage drop or noise, etc. - Controller PCB defective. error

Multi-Zone
MODELS: ASU9RMLQ, ASU12RMLQ, ASU18RMLQ, ARU9RML*, ARU12RML*, ARU18RML*, AUU9RML, AUU12RML, AUU18RML, AOU24RML, AOU36RML, AOU24RML1, AOU36RML1 INDOOR ERROR DISPLAY ERROR CONTENTS
Serial Reverse Transfer Error at Start Up Serial Reverse Transfer Error During Operation Forward Transfer Signal Error at Start Up
Indoor Unit Remote Control - Wired Remote Control

OPERATION
Off Off Off Off 2 flashes 2 flashes 3 flashes 3 flashes 3 flashes 3 flashes 3 flashes 3 flashes 3 flashes 4 flashes 4 flashes 4 flashes 4 flashes 5 flashes 5 flashes 5 flashes 5 flashes 5 flashes 5 flashes 6 flashes 6 flashes 7 flashes 7 flashes 7 flashes 8 flashes 8 flashes 8 flashes Blinking

TIMER
2 3 4 8 2 3 2 3 4 flashes flashes flashes flashes flashes flashes flashes flashes flashes Off Off 7 flashes 8 flashes 2 flashes 4 flashes 7 flashes 8 flashes 2 flashes 3 flashes 5 flashes 6 flashes 7 flashes 8 flashes 2 flashes 3 flashes 2 flashes 3 flashes 6 flashes 2 flashes 3 flashes 4 flashes Blinking

AIR CLEAN
Off Off Off Off Off Off Off Off Off 2 flashes 3 flashes Off Off Off Off Off Off Off Off Off Off Off Off Off Off Off Off Off Off Blinking

COIL DRY
Off Off Off Off Off Off Off Off Off Off Off Off Off Off Off Off Off Off Off Off Off Off Off Off Off Off Off Off Off Blinking

Wire Remote Code No.


01 00 13 00 02 or 03 04 or 05 0C or 0d 06 or 07 0A or 0b 1d 1E 0E 15 20 08 21 22 17 18 1A 1b 1F 1C 12 12 0F 14 16 19

Communication Error Indoor Unit Temperature Error

Room temperature thermistor error Heat exchanger temperature thermistor error Discharge pipe temperature thermistor error Outdoor heat exchanger temp. thermistor error Outdoor temperature thermistor error Outdoor Unit 2 way valve temperature thermistor error Temperature Error 3 way valve temperature thermistor error Heat sink temperaturethermistor error Compressor temperature thermistor error MANUALAUTO button error Indoor Unit Control Power supply 50HZ/60HZ detection error System Error Electronic Air clean filter error Electronic Air cleaner Power PCB Circuit error IPMerror (Current trip error) CTerror Compressor position error Outdoor Unit Control Outdoor fan motor error System Error Connected indoor unit error Main CPU-sub CPU communication error Indoor fan motor lock error Indoor Unit Fan Motor Error Indoor fan motor speed error Discharge pipe temperature error Refrigerant System Cooling High pressure abormal rise Error High pressure switch error Active filter module (AFM) error (Second Time) Added Function Error Active filter module (AFM) error (First Time) PFCCircuit Error Indoor Unit Connect Error Indoor unit error (indoor EEPROM abnormal)
* For concealed ceiling models, refer to the wired remote controller.

11

Multi-Zone
MODELS: AOU24RML, AOU36RML, AOU24RML1, AOU36RML1 Error Contents LED A
1 flash Outdoor communication signal error (forward transfer) OFF OFF OFF Outdoor discharge pipe temperature thermistor error Outdoor heat exchanger temperature thermistor error Outdoor temperature thermistor error 2 way valve temperature thermistor A error 2 way valve temperature thermistor Berror 2 way valve temperature thermistor C error 2 way valve temperature thermistor D error 3 way valve temperature thermistor A error 3 way valve temperature thermistor B error 3 way valve temperature thermistor C error 3 way valve temperature thermistor D error Compressor temperature thermistor error Heat sink temperature thermistor error Pressure switch 1 error Pressure switch 2 error Connected indoor unit error IPMerror Compressor rotor location can not detect (permanent stop) Compressor start up error (permanent stop) Outdoor unit fan motor error Main CPU sub CPUCommunication error 2 flashes 3 flashes 4 flashes 5 flashes OFF OFF OFF 6 flashes OFF OFF OFF 7 flashes 8 flashes 9 flashes 10 flashes 11 flashes 12 flashes 13 flashes 14 flashes 15 flashes 17 flashes

B
OFF 1 flash OFF OFF OFF OFF OFF OFF 5 flashes OFF OFF OFF 6 flashes OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF

C
OFF OFF 1 flash OFF OFF OFF OFF OFF OFF 5 flashes OFF OFF OFF 6 flashes OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF

D
OFF OFF OFF 1 flash OFF OFF OFF OFF OFF OFF 5 flashes OFF OFF OFF 6 flashes OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF

Wall Mounted
MODELS: ASU9RLQ/AOU9RLQ, ASU12RLQ/AOU12RLQ, ASU15RLQ/AOU15RLQ, ASU18RLQ/AOU18RLQ, ASU24CL/ AOU24CL, ASU24RLXQ/AOU24RLXQ, ASU30CLX/AOU30CLX, ASU18RLXS/AOU18RLXS, ASU24RLXS/AOU24RLXS, ASU30RLX/AOU30RLX, ASU30RLXQ/AOU30RLXQ, ASU36CLX/AOU36CLX

Error Indication Operation Timer


0.5 sec 2 Times

Wired Remote
No Display

Error

Diagnosis Method

Indoor fan lock error

0.5 sec 6 Times

Evaporator fan motor error - The indoor fan speed is 0 RPM after 56 seconds from starting operation. -Check if Fan motor connector loose/defective contact. Rotate fan motor by hand to ensure it is not locked. -Controller PCB defective.

0.5 sec 3 Times

No Display

Indoor fan speed error

Evaporator fan motor error - The indoor fan speed is 1/3 of the target frequency after 56 seconds from starting operation. -Check if Fan motor connector loose/defective contact. Rotate fan motor by hand to ensure it is not locked. -Controller PCB defective.

0.5 sec 2 Times

0F

Discharge temperature error

The discharge temperature error is activated. Heat radiation is blocked. -Check for closed 2-way valve or 3-way valves. Check for leaks at line set, condenser and evaporator. -Refrigeration cycle defective. Check for restrictions at line set, low charge.

0.5 sec 7 Times

0.5 sec 3 Times

24

Excessive high pressure protection on cooling

Excessive high pressure protection on cooling mode has been activated. Heat radiation is blocked. -Check for closed 3-way valves. Check for running compressor with outdoor fan OFF. -Check if outdoor fan is defective. Refrigeration cycle defective. Check for high pressure, over charged.

0.5 sec 5 Times

16

Pressure Switch Error

If the pressure switch is open for 10 sec. when the power is turned on - Error will reset when pressure becomes normal. -Check interruption of heat radiation (Air intake/Outlet). Check outdoor fan operation (does not rotate). -Check refrigerant cycle. Check for high pressure, over charged.

0.5 sec 2 Times

19

Active Filter Error (Permanent Stop)

Output voltage error of Active filter is detected. -Check the wiring connection (connector is loose/open. Choke coil) -Active Filter Module/Controller PCB defective. Output voltage error of Active filter is detected. -Check the wiring connection (connector is loose/open. Choke coil) -Active Filter Module/Controller PCB defective.

0.5 sec 8 Times

0.5 sec 3 Times 0.5 sec 4 Times

19

Active Filter Error

25

PFC circuit error

Excessive voltage of DC V on PFC circuit in inverter PCB is detected. -Controller PCB defective.

ALL LEDs Blink Operation, Timer, Air Clean 0.1 sec ON/OFF

11

Model Match Error

Apparent model infromation error from EPROM (miss match). 3 continuous failure of lead test of EPROM at Power ON, Voltage drop or noise, etc. -Controller PCB defective.

Halcyon HFI Indoor Units


MODELS: ASU7RLF, ASU9RLF, ASU12RLF, ASU18RLF, ASU24RLF, AUU9RLF, AUU12RLF, AUU18RLF, ARU9RLF, ARU12RLF, ARU18RLF, ARU24RLF
Error Indication Operation (1) Timer (1) Economy Wired Remote Controller 11 Error Diagnosis Method When the indoor unit cannot receive the signal from the branch unit. When the branch unit cannot receive the signal from the indoor unit Wired remote controller communication error Check operation incompletion error (normally, operation disabled) Wiring mistake Indoor unit capacity error Combination error Connection unit number error (indoor unit). Connection unit number error (branch unit) Indoor unit PCB Model information error Manual auto switch error Inlet room temperature thermistor error Indoor unit Heat Ex. Middle thermistor error Main fan motor lock error Main fan motor revolution speed error Drain pump error Indoor unit error Outdoor unit PCB Model information error. Outdoor unit PCB microcomputer communication error Inverter error Voltage error stoppage permanently. Voltage error (can restore). Over current protected operation stoppage permanently. PFC hardware error. Trip terminal L error Microcomputers communication error Discharge thermistor 1 error Compressor thermistor 1 error Outdoor unit Heat Ex. liquid thermistor error Outdoor thermistor error Suction Gas thermistor error Heat sink thermistor error Sub-cool Heat Ex. gas inlet thermistor error Sub-cool Heat Ex. gas outlet thermistor error Liquid pipe thermistor 1 error Current sensor 1 error (stoppage permanently) Discharge pressure sensor error. Suction pressure sensor error. High pressure switch 1 error Trip detection Rotor position detection error (stoppage permanently) Duty error 4-way valve error Discharge temperature 1 error Compressor temperature error Low pressure error EEPROM access error Equipment type information error Serial communication error to outdoor unit Branch units serial communication error Serial communication error to indoor unit Liquid pipe thermistor error Gas pipe thermistor error Expansion valve full closure operation error Remote control communication error Branch unit error

Serial communication error Remote controller-communication error Scan error- communication error Initial setting error - Function setting Indoor unit capacity error Function setting Connection disabled (series error) Function setting Connection unit number error Function setting Indoor unit main PCB error Manual auto switch error - Indoor Unit Room error Indoor unit Heat Ex. sensor error Indoor unit fan motor error Water Drain error - Indoor Indoor unit error Outdoor unit main PCB error Inverter PCB error - Outdoor Active fi lter error, PFC circuit error Outdoor IPM error - Outdoor Display panel error - Outdoor Discharge thermistor error - Outdoor Compressor thermistor error Outdoor Outdoor unit Heat Ex. Sensor error Outdoor thermistor error - Outdoor Suction Gas thermistor error Outdoor Heat sink thermistor error - Outdoor Sub-cool Heat Ex. Gas thermistor error - Outdoor Liquid pipe thermistor error - Outdoor Current sensor error - Outdoor Pressure sensor error - Outdoor Trip detection - Outdoor Compressor motor control error Outdoor Outdoor unit fan motor 1 error Outdoor 4-way valve error - Outdoor Discharge temperature 1 error Refrigerant System Compressor temperature error Refrigerant System Pressure error 2 - Refrigerant System

(1) (1) (2) 2 (2) (2) (3) (3) (4) (4) (5) (5) (5) (6) (6) (6) (6) (6) (7) (7) (7) (7) (7) (7) (8) (8) (8) (8) (9) (9) (9) (9) (10) (10) (10)

(2) (5) (1) (2) (3) (4) (2) (5) (1) (2) (1) (3) (15) (2) (3) (4) (5) (10) (1) (2) (3) (4) (5) (7) (2) (3) (4) (6) (4) (5) (7) (9) (1) (3) (5)

12 15 21 22 23 24 32 35 41 42 51 53 5U 62 63 64 65 6A 71 72 73 74 75 77 82 83 84 86 94 95 97 99 A1 A3 A5

(13)

(5)

J2

Unit flow divider error - Branch Box

Display mode

0.5s ON / 0.5s OFF, ( ) : Number of flashing, : 0.1s ON / 0.1s OFF

Halcyon HFI Branch Boxes


MODEL: UTP-PU03A, UTP-PU03B

When an error occurs, an error description displays in the LED (No. 401 ~ 405).

(n)

Normal status
Green LED401 LED402 LED403 Red

Lit Flashing (number of flashing) Unlit

LED404

LED405

Comment This box is functioning properly.

Error status
Green LED401

LED402

Red LED403 LED404

LED405

Error Description Connected combination error Power frequency error EEPROM access error Model information error Serial communication error between outdoor unit and branch box Serial communication error between branch boxes Serial communication error between branch boxes Serial communication error between Indoor Unit A and branch box Serial communication error between Indoor Unit B and branch box Serial communication error between Indoor Unit C and branch box Indoor Unit A, liquid pipe thermistor error (CN309) Indoor Unit B, liquid pipe thermistor error (CN309) Indoor Unit C, liquid pipe thermistor error (CN310) Indoor Unit A, gas pipe thermistor error (CN309) Indoor Unit B, gas pipe thermistor error (CN309) Indoor Unit C, gas pipe thermistor error (CN310) Indoor Unit A, EEV control error (CN305) Indoor Unit B, EEV control error (CN306) Indoor Unit C, EEV control error (CN307) Remote controller communication error


Branch Box identifying display Primary unit : (1) Secondary unit1 : (2) Secondary unit2 : (3)


(1) (2) (3) (4) (5)

(6)

(7)

(8) (9)

Halcyon HFI Outdoor Unit


MODEL: AOU48RLXFZ

When error occurs, Err and Number of error occurred are alternately displayed in 7 seg. display. The latest error code can be confirmed by pressing the ENTER button. When error codes are displayed, all the error codes can be confirmed by pressing the SELECT button. Example: When Discharge thermistor error and Compressor thermistor error are occurred SELECT ENTER Press the SELECT button. Press the ENTER button. SELECT

ENTER

CODE
E E E E E E E E E E E E E E E E E 1 1 1 2 2 2 2 5 6 6 6 6 6 7 7 7 7 1 1 5 1 2 4 4 U 2 3 4 5 A 1 2 3 4 3 4 6 2 1 2 3 1 1 1 1 3 1 1 1 3 1

DESCRIPTION
Serial communication error Check run unfinished Number of wires and pipes error Indoor unit capacity error Number of indoor units error Number of Branch boxes error Indoor unit error Outdoor unit model information error Inverter error A.F. voltage error I.P.M. error Display P.C.B. communication error Discharge thermistor error Compressor thermistor error Heat EX. liquid outlet thermistor error Outdoor thermistor error E E E E E E E E E E E E E E E E E

CODE
7 7 8 8 8 8 8 8 8 9 9 9 9 A A A J 5 7 2 2 3 4 6 6 6 4 5 7 9 1 3 5 2 1 1 1 2 1 1 1 3 4 1 1 3 1 1 1 1 U

DESCRIPTION
Suction gas thermistor error Heat sink thermistor error Sub-cool heat EX gas inlet thermistor error Sub-cool heat EX gas outlet thermistor error Liquid pipe thermistor error Current sensor error Discharge pressure sensor error Suction pressure sensor error High pressure switch error Over current error Compressor control error Outdoor unit fan motor error 4-way valve error Discharge temp. error Compressor temp. error Low pressure error Branch boxes error