HANDOUT #11
B201
B202
P2
C201 C202 C203 3.5 m
B101
B102
P1
C101 C102 C103 3.5 m
7m
7m
COLUMNS :
8-22
8 STIRRUPS AT A SPACING OF 200 mm PROVIDED ALONG THE ENTIRE LENGTH OF THE COLUMNS. BEAMS : 450 mm x 600 mm WITH 3-22 AT THE TOP 3-22 AT THE BOTTOM 8 STIRRUPS AT A SPACING OF 150 mm PROVIDED ALONG THE ENTIRE LENGTH OF THE BEAMS. CONCRETE COVER : CLEAR COVER = 20 MM COVER TO THE CENTER OF LONGITUDINAL REINFORCEMENT = 20 MM + 8 + (22)/2 = 39 MM TAKE COVER TO THE CENTER OF LONGITUDINAL REINFORCEMENT AS 40 mm FOR BOTH THE BEAMS AND THE COLUMNS (NOTE: TOP AND BOTTOM REINFORCEMENT IN THE BEAMS IS ASSUMED EQUAL IN ORDER TO SIMPLIFY THE ANALYSIS (Mult+ = Mult-). TYPICALLY, THE AMOUNT OF TOP REINFORCEMENT WOULD BE LARGER SINCE NEGATIVE MOMENTS RESULTING FROM BOTH GRAVITY AND EARTHQUAKE LOADS NEED TO BE RESISTED AT THE BEAM/COLUMN JOINTS) MATERIALS : C20 CONCRETE S420 STEEL (FOR BOTH LONGITUDINAL AND TRANSVERSE REINFORCEMENT)
2
BUILDING
LOADS
DEAD LOAD (SELF WEIGHT) : G = 20 kN/m LIVE LOAD : Q = 10 kN/m (DISTRIBUTED LOAD ON THE BEAMS)
(NOTE: IF GIVEN THE PLAN VIEW OF THE BUILDING, NEED TO CALCULATE THE DISTRIBUTED DEAD AND LIVE LOAD PER UNIT LENGTH ON THE BEAMS, BASED ON THE TRIBUTARY WIDTH OF EACH BEAM AND THE DEAD AND LIVE LOAD VALUES DISTRIBUTED OVER THE FLOOR AREA) RESPONSE SPECTRUM VARIABLES (TDY-2007):
EQ Zone
Soil Type
: :
BUILDING IMPORTANCE COEFFICIENT: ALWAYS TAKE BUILDING IMPORTANCE COEFFICIENT AS I = 1.0 FOR ASSESSMENT OF EXISTING BUILDINGS USING PUSHOVER ANALYSIS METHOD (SECTION 7.4.2 IN TDY-2007) STORY MASSES (TDY-2007): SHALL BE DEFINED IN ACCORDANCE WITH STORY WEIGHTS DEFINED IN SECTION 2.7.1.2:
THEREFORE,
wi = 322 kN (ON SINGLE FRAME) mi = wi / g = (322 x 103 N) / (9.81 m/s2) mi = 32,823 kg = 33 tons (ON SINGLE FRAME)
4