The Product - Page 04
SaIient Features - Page 04
Front PaneI - Page 05
Back PaneI - Page 06
TroubIeshooting - Page 07
TechnicaI Specifications - Page 09
SoIar PaneI SeIection - Page 10
Servicing - Page 11
Warranty - Page 11
Safety Instructions - Page 13
Important - Page 14
Going on Vacations - Page 14
3
ThE P0T
SOLAR UPS SLB is an electronic power source which stores the energy in batteries connected to it from the solar module
as well as ACmains supply at the same time and converts this energy automatically to ACpower when the nput ACsource
fails and automatically feeds generated AC power to the loads connected & returns to mains when the AC source comes
back on the input side. The charging of batteries with both energy sources is carried out fully automatically.
8ALIEhT FEATE8
MICRO CONTROLLER BASED MICROTEK SOLAR UPS SLB are designed using Iatest state-of-the-art TechnoIogy for
Better Performance and High ReIiabiIity. The DigitaI TechnoIogy used enhances the Iife of the battery and minimum
effort has to be put for maintenance.
MCRO-CONTROLLERBASEDntelligent Control Design.
Display ndications (Status &Fault)
CCCVTechnology with Auto Trickle Mode
Smart Overload Sense and Short Circuit Protection
Battery State Monitoring
Easily Serviceable
Solar Power Module Based Charger
Mains nput Voltage Range Selection
4
FhT PAhEL
I. LEDIndications
1. Mains ON.
2. UPS ON.
3. Battery Charging.
LED Continuously Glows
when Charged.
LED Blinks when Battery is
Charging.
4. Fuse Blown.
5. UPS Overload.
6. Battery Low.

MAINS
ON
UPS
ON
CHARGING
CHARGED
UPS
OVERLOAD
BATTERY
LOW
FUSE
BLOWN
STATUS FAULT
BATTERY
1 2 3 5 6 4
5
8A0k PAhEL
1. Mains nput Terminal Block for ACinput.
2. Circuit Breaker for mains overload / short circuit
protection. (8Amps/10Amps for UPS SLB850/UPS SLB600
Model, 15Amps/16Amps for UPS SLB 1400 Model)
3. Output socket for load.
4. Positive Battery Lead.
5. Negative Battery Lead.
6. Fuse (10Amp Slow Blow) for Charger.
7. Slide Switch for Mains nput Voltage Range selection.
8.
9. Solar Module input Terminal Block.
10. Solar ndication.
Slide Switch to Select the Maximum Charging Voltage. (HGH= 14.2V DC / Standard (STD)= 13.8 V DC).
Select the appropriate Voltage as recommended by the Battery Manufacturer/Supplier.
CAUTION: Proper seIection of switch position is recommended based on the battery manufacturers specifications,
for proper backup and aIso to avoid any damage to the battery due to wrong seIection.
6
N E L
180V~260V
100V~300V
InpuI Vo|Iage
ange
0harg|ng
Vo|Iage
HIGH
STD.
6
1
7
8
2
3
4 5
9 10
n case of UPS SLB 850/600 - 12V Batt. Sys.
n case of UPS SLB 1400 - 24V Batt. Sys.
T8LE 8hTIh
ProbIem PossibIe Cause / Action Suggested
1. Main Supply is Normal but:-
a) UPS is working on battery a) i) Check the AC Mains presence in the Mains AC
wall socket.
ii) Check the AC mains input voltage, which should be
in the range of 100~300V.
b) Fuse BIown b) Check Charger Fuse at the rear. f blown change it
to 10Amp rating. f fuse still blows call authorised
service engineer.
c) No output from UPS c) Check Circuit Breaker/MCB at the Rear. Push the
Circuit Breaker (Reset)/Switch On the MCB, to Switch
On the output. f it trips again, call electrician to check
shorting/overload in the output circuit.
2. UPStrips frequently at UPSmode. The load is more. Reduce the load and reset the
UPS.
3. UPSMode but no power:-
a) Overload a) Reduce the load and turn the reset switch on the
front panel ON-OFF-OFF-ON.
L
E
DuP3 0N
0reer LE0 0|oWs
L
E
D
Va|rs Fuse 8|oWr
Red LE0 0|oWs
L
E
D
0ver|oad
Red LE0 0|oWs
7
T8LE 8hTIh
ProbIem PossibIe Cause / Action Suggested
b) Low Battery b) Battery has discharged. Recharge the battery after
the mains restoration.
c) Short Circuit c) Check or reduce the output load and turn the reset
switch on the front panel (ON-OFF-OFF-ON).
4. Backup time less. a) Check battery water and charge the battery with mains
minimum for 8-12 hours. f still less backup, get the
battery checked up from authorised service personnel.
5. UPSdoes not operate.
a) Check the battery connections and the mains
connections.
6. UPSdoes not charge with Solar Power Module
a) Check the Solar Power LED ndication at the rear &
Connection at the Solar Power Module Terminal.
L
E
D
LoW 8allery
Red LE0 0|oWs
L
E
D
0ver|oad/3|orl C|l.
Red LE0 0|oWs
8
TE0hhI0AL 8PE0IFI0ATIh8
nput voltage 100V~300V (Wide input voltage range)
180V~260V (Normal input voltage range)
Output Voltage on mains mode Same as input
Output Voltage on UPS mode 200V ~ 230V + 10%
Output frequency on UPS mode 50 Hz + 0.1 Hz
Switching from mains to UPS Automatic
and from UPS to mains
Output waveform on mains mode Same as nput
Output waveform on UPS mode TPZi Wave form (TRAPE ZODAL WAVEFORM)
Battery charging current Constant charging approx 10% of the rated
battery current in AH
Charger (Dual Mode Charger) Constant current, Constant wattage & Solar Charger
Efficiency > 90%
UPS Overload 120%
UPS short circuit 300%
Browns out mains voltage 100V + 40V
Technology MCRO CONTROLLER BASED DESGN
Auto Reset Feature Yes
Solar Power Module 12V Solar Power Module for UPS SLB 600 / UPS SLB 850
24V Solar Power Module for UPS SLB 1400
NOTE:- Because of a policy of continuous product improvement, the specifications are subject to change without notice.
9
Solar Panel in Microtek UPS-EB is used to charge the batteries from the solar power as primary source of energy in
conjunction with utility power available.
The Max. Solar Panel Size recommended for Microtek Solar UPS-EBis as follows:-
UPS-EBBatteries VoItage = Solar Panel Voltage
OR
= Solar Panel Voltage Available x No. of Panels
UPS-EBBattery AH = Max. Solar Panel Wattage
For ExampIe:- Hence for Max. SoIar PaneIs Recommended
12V/70AHBatteries = 12V/70Watt x 1 Panel
12V/100AHBatteries = 12V/100Watt x 1 Panel
12V/150AHBatteries = 12V/75Watt x 2 Panel (Connect in Parallel)
24V/150AHBatteries = 24V/150Watt x 2 Panel (Refer PC-1)
OR
12V/75Watt x 4 Panel (2 series + 2 Parallel) (Refer PC-2)
8LA PAhEL 8ELE0TIh
10
12V/75W 12V/75W
12V/75W 12V/75W
(PIC-2)
24V/150W
24V/150W
(PIC-1)



8EVI0Ih
n the unlikely event of your facing problem that has not been sorted out by troubleshooting, kindly contact your authorised dealer
and give details of the problem along with the serial number and the date of installation. This would enable a prompt action on part
of the authorised service personnel and cause minimum down time.
Microtek nternational P. Ltd., warrants each instrument to be free from defects in materials and workmanship for a period of Two
years after initial delivery. This obligation is limited to servicing any instrument or part returned to the authorised service center for
that purpose and to making good any parts thereof which shall, within the warranty period, be returned to the company or
authorised Service center under a written intimation and which to the company's satisfaction be found defective. The company
reserves the right to decide as to whether the repair work should be carried out in the company's service center or at site or at any
other place.
The freight incurred for to and fro dispatch will have to be borne by the customer and the transit risk for the material will rest with
the customer.
The warranty does not extend to any parts of the instrument which have been subjected to misuse or accident. Further, this
warranty does not extend to any instrument which has been tampered with by any agency not authorized by the company.
The warranty will last for a period of 24 months from the date of initial delivery/dispatch of the instrument if used within its
specifications. The warranty for the replaced components will lapse along with that of the main instrument.
wAAhTY
11
wAAhTY
MCROTEKnternational P. Ltd., reserves the right to make changes in design and specifications without notice and without any
obligation to install such changes on units previously supplied.
n no event will MCROTEKnternational P. Ltd., its distributors / dealers be liable for consequential damages or for any expenses
incurred by the buyer or user, due to use or sale of products sold by MCROTEK nternational P. Ltd., directly or through its
authorised Distributors / dealers or any third party.
Until superceded otherwise or in contractual form this warranty is made expressly in lieu of all other liabilities and obligations on
part of MCROTEKnternational P. Ltd.
Title to the nstrument passes to the buyer upon delivery to the common carrier.
POST WARRANTYANNUALMAINTENANCECONTRACT
For Microtek UPS SLB Models, Microtek Offers Annual Maintenance Contract to save you from any inconvenience in case of a
product failure. Various options are available in select cities for all models of Microtek UPSSLB:-
For Details, Contact nearest Microtek Branch or e-mail at: power.support@microtekdirect.com
12
8AFETY Ih8T0TIh8
Always connect the UPSto a two pole, three-wire grounding mains socket. The socket must be connected to appropriate
branch protection (fuse/circuit-breaker). Connection to any other type of socket may result in a shock hazard.
To switch off the UPS output in emergency, use switch on the Front panel. Also disconnect the mains cord and battery
wires.
Avoid installing the UPS in open, excessively humid place or where there is water. Care must be taken to ensure that the
UPS is kept away from heat-emitting appliances such as a heater, blower, oven etc. The unit must also be placed in a
manner that it avoids exposure to sunlight. The place of installation should be well-ventilated and easily accessible for
servicing.
Foreign objects and water must not enter the UPS. Always ensure that objects containing liquid are avoided near the
unit.
13
n the event of any instrument requiring service at our authorised service centre, the following procedure should be adopted.
1. The instrument must be securely packed, preferably in its original packing.
2. The instrument should be despatched on Freight-prepaid basis duly insured.
3. One of our Service / Sales Executive should be informed of the goods Receipt No. and date of despatch along
with the name of carrier.
4. The above procedure should only be adopted on the advise of one of our Service / Sales Executive or Dealer.
5. We reserve the right to charge the consignee for any damage incurred during transit.
1. Must put the UPS ON/OFF Switch in OFF Position.
2. Mains nput should remain connected to keep the battery always in charged condition.
INPTAhT
Ih h VA0ATIh8
14
15
H-57, Udyog Nagar, Rohtak Road, New Delhi-110041. Sales Tel.: 011-25967345
SaIes E-maiI: sales@microtekdirect.com Service E-maiI: power.support@microtekdirect.com
002-158-UPS SLB 600/850/1400 V.2(15/10/07)
16