Sei sulla pagina 1di 2

Stefan Mayer Instruments

Wallstr. 7 D-46535 Dinslaken, Germany Phone/Fax: +49 2064 479762/3 http://www.stefan-mayer.com Email: mail@stefan-mayer.com

Magnetic Field Compensation System MR-3


Three axis automatic compensation of low frequency magnetic eld disturbances

Features
Continuous real time compensation of magnetic eld disturbances from DC to 1 kHz Typical 40 dB attenuation of 50 Hz magnetic eld Magnetic eld measurement with high resolution uxgate sensors Rugged analog design, no tedious programming Integrated power ampliers for direct connection of compensation coils Field monitor and alarm functions

Applications
Improvement of electron microscope images (SEM and TEM) Biomagnetic and paleomagnetic applications Compensation of power line frequencies (50/60 Hz) and harmonics Attenuation of slow or stepped magnetic eld changes caused by vehicles, moved magnetic objects, elevators, etc. Special versions for MRI applications available

Description
The magnetic eld compensation system MR-3 is a proven solution of problems related with magnetic eld noise. Typical applications are noise reduction in electron microscopy, electron and ion beam experiments, magnetic resonance imaging (MRI), biomagnetic investigations, SQUID operation, and paleomagnetic research. The MR-3 is a feedback compensation system. The magnetic eld noise is reduced by establishing a compensating magnetic eld in opposite direction. The MR-3 continuously compensates magnetic eld disturbances in the frequency range from DC to 1 kHz. The magnetic eld is measured with a low noise triaxial uxgate magnetometer. Analog control electronics generate compensation signals which are fed to the built-in power ampliers for direct connection of compensation coils. Typically, such coils simply consist of a set of cable rings with a low number of wires installed in the edges of the laboratory. Customized modications, compensation coils, and installation service are available on request.

MR-3 o SEM image improvement

MR-3 on

Specications
Magnetic eld sensor Zero drift Noise Analog outputs Bandwidth Digital displays Analog meters Attenuation @ 50 Hz Attenuation @ 250 Hz Recom. compensation coil impedance Subject to alterations. triaxial uxgate sensor < 0.1 nT/K < 0.7 nT RMS (0.1 Hz < f < 1000 Hz) 1 V/T, BNC connectors for X, Y, Z 0 to 1000 Hz (3 dB) show incremental DC or true rms AC magnetic eld for X, Y, and Z show coil current, range 3 A typ. 40 dB at sensor position typ. 20 dB at sensor position 2