Sei sulla pagina 1di 11

CUSTOMER PROJECT NO.

: :

SAMSUNG HEAVY IND' CO.,LTD

PROJECT NAME : HHI REF' NO. : # CLASS : LRS

SHI-H1675 / H1676 / H1677 2006S0026

* 3P 60Hz 1500KVA(1P 500K X3) 6.6/0.45KV * 3P 60Hz 4650KVA(1P 1550K X3) 6.6/0.45KV

IP23 IP23

[CARGO HV TR.] [MAIN HV TR.]

SPECIFICATION FOR TRANSFORMER


[ 266,000 CBM LNG CARRIER ]

FOR APPROVAL
Please return one copy with approved signature or stamps.
HYUNDAI HEAVY INDUSTRIES CO.,LTD.

0 REV

2006.06.20 DATE

FOR APPROVAL CONTENTS

D.H.JUNG
PREPARED BY

H.D. KIM
CHECKED BY

K.H. SONG
APPROVED BY

HYUNDAI HEAVY INDUSTRIES CO.,LTD.


ELECTRO ELECTRIC SYSTEMS DIVISION
DISTRIBUTION TRANSFORMER DEPARTMENT FAX.NO.:+82-52-274-6735,TEL.NO.:+82-52-270-9141~46, 9272

HHI A22-228-0

HYUNDAI HEAVY INDUSTRIES CO.,LTD.

A4(210mm x 297mm)

GENERAL SPECIFICATION
1. GENERAL
This specification is for the cast resin-type marine transformer, designed and manufactured to comply with buyer's requirements, classification and maker's standard specification in order to endure worst sea conditions during long voyage and vibration shake, salinity and ambient temperature changes etc.

T - 1

2. CONSTRUCTION
a) TRANSFORMER ENCLOSURE

Transformer enclosure constructed of mild steel will be so designed as to allow the complete transformer in the enclosure to be lifted by crane and transported by ship or vehicle without overstraining any joints. Enclosure protection grade will be IP-23 the ventilation holes on the wall of the transformer enclosure will be provided to sufficiently cool down the heat generated by transformer losses.

b) CORE

The core is made exclusively of cold-rolled grain-oriented sheet coated with magnesium-silicate-phosphate insulation on both sides. To fully utilize the grain orientation of the laminations, the ends of the limbs and yokes are mitered and stacked together by overlapping the laminations in pairs, which will reduce the no-load losses and thus the power required for magnetizing the core. The core will be rigidly clamped with positive locking devices to ensure adequate mechanical strength to support the winding and also to prevent shifting of laminations during transport and further to reduce vibration to a minimum during operation

c) WINDING

The winding of cast-resin type tr. are wound together with high grade insulating sheet from aluminum strip and potted under vacuum up to the terminals. Aluminum is also used as the conductor material for the low voltage strip winding. Sufficient cooling channels between windings will be provided and all winding will be constructed firmly to be sustained from external and internal mechanical stress. (Refer to material of page T-3) Transposition will be done on each winding and winding end of primary and secondary will be positioned opposite side to each other.

d) TERMINAL BOARD AND OTHER FITTINGS

Terminal board is connected to primary and secondary voltage, and also other necessary parts such as lifting eyes are furnished.

HHI A22-228-0

HYUNDAI HEAVY INDUSTRIES CO.,LTD.

A4(210mm x 297mm)

GENERAL SPECIFICATION
3. ROUTINE TESTS
The following tests will be carried out at maker's shop according to class rule and the records of such testing will be submitted to the customer.

T - 2

1) 2) 3) 4) 5) 6) 7) 8)

Structure check Resistance measurements of the windings Insulation resistance measurements Ratio test Angular displacements test (or polarity test) Excitation loss measurements Excitation current measurements Applied voltage test (1 minute) p-e s-e

7.2Kv Below

20.0 3.0

kv kv

rated frequency 9) Induced voltage test : 120 ---------------- (sec) test frequency 10) Load loss and impedance voltage measurements 11) Voltage regulation calculation

4. TYPE TEST
Temperature rise test (only one of same capacity transformer in each ship)

5. PAINT COLOR
All surface will be thoroughly cleaned before painting and coated with priming coat immediately after cleaning, followed by two further coats of a high quality oil and water resisting paint. The final color will be : 7.5BG 7/2

6. NAME PLATE
The transformer will be provided with a staineless steel name plate showing the following informations : 1) Serial number 3) Frequency 5) Rated voltage 7) Tap voltage 9) Vector group symbol 11) Standard applied 13) Name of manufacturer 15) Kind of transformer 17) Type of cooling
HHI A22-228-0

2) Number of phase 4) Rated Capacity 6) Rated currents 8) Insulation class 10) Percent impedance 12) Connection diagram 14) Approximate weight in kg 16) Year of manufacture 18) IP-DEGREE
A4(210mm x 297mm)

HYUNDAI HEAVY INDUSTRIES CO.,LTD.

GENERAL SPECIFICATION
7. RATING & TECHNICAL DATA (CAST RESIN TYPE)
Rule & Class Max. Ambient Temp' () Winding Temp' Rise () Cubicle Protection Degree Use Rating : Continuous(kVA) Transforming Function Material of Winding (HV/LV) No. of Set Frequency Pri. Voltage (sets) (Hz) (V) NO.1(2) CARGO HV TR. 3PH 1500 (1P 500K X 3) Step down & up Aluminum / Aluminum 2 60 6600 F6765 - R6600 - 6435 450 Dd0 B LRS / IEC60726 45 70 (B) IP 23

T - 3

NO.1(2) MAIN HV TR. 3PH 4650 (1P 1550K X 3)

Step down Copper / Copper 2

Pri. Tap Voltage (V) Sec. Voltage Polarity Connection Insulation. Class Electrical Performance Data Efficiency (%) (V)

Rate Voltage & Frequency & Capacity


98.7 2.5 1.5 5.6 HTP70 (O.D 54mm) X 1EA TP150 (O.D 54.2mm) X 9EA 0.76 5.54 5.6 1.29 (S/up : 45.2) 18.0 99.0 2.0 1.5 6.15 HTP150 (O.D 71.1mm) X 2EA TP150 (O.D54.2mm) X 28EA 0.68 6.11 6.15 3.50 36.0

No-Load Current (%) Volt. Regulation (P.F : 1.0) Impedance Cable Incoming Type (coaming hole) Ref. Design Value (%) (%) Pri. Sec. % RT % XT % ZT Inrush current(KA)
Heat dii'tion(Kw) for 3phase

[NOTE] - PT100ohm (2EA For Each Phase) - SPACE HEATER (1PH 220V 100WX2EA) - EARTH SCREENS TO BE PROVIDED BETWEEN PRIMARY AND SECONDARY WINDINGS. HHI A22-228-0 HYUNDAI HEAVY INDUSTRIES CO.,LTD. A4(210mm x 297mm)