This is a presentation for the E2-E3 E & WS Module for the Topic: MLLN Eligibility: Those who have got the Upgradation to from E2 to E3. This presentation is last updated on 18-3-2011. You can also visit the Digital library of BSNL to see this topic.

For internal circulation of BSNLonly

AGENDA
Introduction of Leased line

Over view of MLLN Network


MLLN Architecture Conventional Leased Line TVARIT System

For internal circulation of BSNLonly

Leased Line Introduction


1. A leased circuit is a dedicated link provided between two fixed locations for exclusive use of the customer. 2. It is a dedicated point to point line connecting the facilities of a Customer for telephone sets, EPABX,Computers, etc. or for forming a VPN.

For internal circulation of BSNLonly

Need for Leased Line


Connecting geographically spread out locations. Dedicated transmission. Security. Ease of communication. Stand by arrangement. Networking. Interconnection.

For internal circulation of BSNLonly

IMPORTANTANCEOFLEASEDLINES
Leased circuit provides us high revenue. Leased circuits serve very important needs of customers. Expectations of customers are very high. They need high Q.O.S. & want to sign SLAs. In the changing economic environment dependence of activities on leased circuits is increasing. Due to emerging competition rates are bound to go further down with many more new features.
For internal circulation of BSNLonly

What is MLLN
MLLN Stands for Managed Leased Line Network. MLLN is a Fully Managed Access Network, which allows the operator to keep an end-to end control over the customer circuit and hence provide him guarantees of uptime of the circuit (QoS, SLAs). MLLN is a Next generation Digital Access Network which provides solutions to all the Data networking and Voice requirements of the customer. MLLN is an Overlay network realized through Tellabs Networking Elements, which offer Multiple Value-added and customized services to the customers.
For internal circulation of BSNLonly

Segments Addressed by MLLN


Managed Bandwidth Leased Lines to Alternate Service Providers. Paging ,VAS , Cellular, ISP & Value added Service Providers. Virtual Private Network (VPN). Stock exchanges, Banks, MNCs, Publishing Houses, Software Developers, Broadcasting companies. Multi-Service Network for Governance applications , State Wide Networks. Enhanced support for legacy applications Hotlines, PABX-IC, Point to Multi-point circuits, ISDN Service extension, Data circuit for Security & Travel applications

For internal circulation of BSNLonly

Tellabs 8100 Network Elements


All elements managed end-to-end by one system: the Tellabs 8100 network manager

Tellabs 8130 micro node

Tellabs 8160 accelerator node A111

Tellabs 8170 cluster node

Tellabs 8110 NTU

Tellabs 8120 mini node

Tellabs 8140 midi node Tellabs 8150 basic node

MLLN ARCHITECTURE
MLLN Elements DXC (Digital Cross-Connect)

VMUX (Versatile Multiplexer)


NTU (Network Terminating Unit) NMS (Network Management System) (Centralized NMS for the whole network having main NMS site at Bangalore and the Disaster Recovery(DR) site at Pune)
For internal circulation of BSNLonly

Cluster Node(DXC)
DXC

In Master and Slave Configuration


Modular DACC - 32 to 256 E1s Full management from NMS

For internal circulation of BSNLonly

Basic Node(VMUX)
VMUX

3 Types of V-MUX
V-MUX Type-1, V-MUX Type-2 & V-MUX Type-3 (AC/DC Power) Built-in HDSL modem interfaces Full management from NMS

For internal circulation of BSNLonly

Features of MLLN elements


NTU

Wide range
HDSL Network interfaces Different types of CPE interfaces Long drive on copper (7 km) Full management from NMS

For internal circulation of BSNLonly

NMS
NMS

Best in the industry


User friendly GUI Open & redundant architecture

For internal circulation of BSNLonly

BSNL MLLN NETWORK


Covering around 600 cities nationwide 3 tier architecture of DXCs Core network of regional DXCs (R-DXCs) at Mumbai, Delhi, Kolkatta and Chennai and Sub

Regional (SR-DXCs) at various locations in the


four maintenance regions

For internal circulation of BSNLonly

BSNL MLLN NETWORK


Mesh connectivity between R-DXCs Mesh connectivity between SR-DXCs of the same region. All SR-DXCs connected to R-DXCs. Major SSAs have been provided with SS DXCs. Remote Operator Terminal (ROT) planned for every station having more than 30 leased circuits.

For internal circulation of BSNLonly

DIGITAL CROSS CONNECT (DXC)


Features of DXC Capacity DXC (64 ports upgradeable to 128 ports) DXC (96 ports upgradeable to 128 ports) DXC (128 ports upgradeable to 256 ports) DXC (256 ports) I/0 cross-connect capability

Non-Blocking Architecture

For internal circulation of BSNLonly

DIGITAL CROSS CONNECT (DXC)


Redundancy Power Supply Switching Matrix Cross-connect Memory Expansion to be made possible by addition of cards only Fully Managed from Centralized NMS

For internal circulation of BSNLonly

Tellabs 8170 DXC

For internal circulation of BSNLonly

VERSATILE MULTIPLEXER (VMUX)


Types of VMUX V-MUX Type-IA V-MUX Type-IIA Cards (PFUA-1,OMH-5 ,QMH- 2,XCG-1) (PFUA-1,OMH-2,XCG-1)

V-MUX Type-IIIA (PUA/PFUA-1,OMH-2,XCG-1) 230V AC Powered -48V DC Powered Expansion to be made possible on the same chassis by addition of cards.

For internal circulation of BSNLonly

VERSATILE MULTIPLEXER (VMUX)


VMUX to be able to extend hotline circuits.

Point to point and Point to Multi-point circuit routing are possible.


HDSL Driving Distance: 3.5km at 2Mbps 5 km at 1Mbps 7km for 64/128kbps (at 0.5mm dia copper cable)

For internal circulation of BSNLonly

VERSATILE MULTIPLEXER (VMUX)


V-MUX Type Initial Requirement Hot line E1 Expansion Requirement (Incremental) E1 Nx Hot 64kb line ps 8 4 8 8 4 4 4

Nx 64kbp s VMUX Type 1A 40 VMUX Type 2 VMUX Type 3 AC/DC 16 16

12
4 4 4

For internal circulation of BSNLonly

Tellabs 8150-VMUX TPYE-1A

For internal circulation of BSNLonly

NETWORK TERMINATION UNIT (NTU)


Features of NTU Capacity 64/128kbps NTU with V.35 interface 64/128kbps NTU with G.703 interface N x 64kbps NTU with V.35 interface N x 64kbps NTU with G.703 interface N x 64kbps NTU with Ethernet Interface Line Loop Testing as per ITU-T rec V.54 NTU to send power off signal to the NMS at the time of NTU getting switched off.

For internal circulation of BSNLonly

Types of NTUs with different interfaces

Tellabs 8110 STU-160/V.35 for 64/128 kbps NTU

with V.35 interface


Tellabs 8110 STU-160/G.703 for 64/128 kbps NTU with G.703 interface.

STU-160 works up to 128kbps


CTU-S and CTU-R works up to 2Mbps on a single pair of copper

For internal circulation of BSNLonly

Network Terminating Unit (NTU)

For internal circulation of BSNLonly

NETWORK MANAGEMENT SYSTEM


Features of NMS (Centralized NMS for the whole network having main NMS site at Bangalore and the Disaster Recovery(DR) site at Pune)

MLLN NMS Billing and Accounting System


Web Self-care system

For internal circulation of BSNLonly

NETWORK MANAGEMENT SYSTEM


MLLN NMS performs all the management functions on the network Provides complete functionalities Supports regional partitioning and VPN capabilities

Performance Monitoring, Recovery, Reporting Packages

For internal circulation of BSNLonly

Conventional Leased Circuits


Upgradability :In steps 64K, 2M Monitoring :No Manageability :No Testing :Fault localization Lengthy (NFF)

Coordination Problems :Fault in Modem/ Last mile


Provisioning :Long (Patching) SLA :No

Bandwidth on Demand :No


For internal circulation of BSNLonly

Leased Circuits on MLLN


Upgradability :In N * 64K Monitoring :Yes Manageability :Yes Testing :Fault localization Faster Coordination :No Problem (Both Modem/ Last mile of BSNL) Provisioning :Fast (Config.) SLA :Yes Bandwidth on Demand :Yes
For internal circulation of BSNLonly

MPLS VPN
Upgradability :In n * 64K (even for non- MLLN) Monitoring :Yes (even for non- MLLN)

Manageability :Yes
Testing :Fault localization Faster (Monitoring by NOC even for Non- MLLN)

Coordination :Depends on last mile (MLLN ?)


Provisioning :Fast (Config.) SLA :Yes (even for non- MLLN)

Bandwidth on Demand :Yes


For internal circulation of BSNLonly

MPLS Vs MLLN
MPLS MLLN

Security
IP based Shared

Leased, 100%
PPP

QOS ,not 100%assured 100% available dedicated

For internal circulation of BSNLonly

LEASED CIRCUIT MEDIA


Leased circuits are available on Optical Fiber Media Radio Media Copper Wire and Satellite Media or a Combination of these media Local media and national long distance media are by the BSNL/MTNL and International Media by VSNL

For internal circulation of BSNLonly

TYPE OF LEASED CIRCUIT SERVICES


1. Speech Circuits (Hot Line or P-Wire) - Local or Long distance circuits within a city or between two different cities provided for the same applicant. The terminating equipment at both ends is telephone without dialing facility. Both way signaling and speech is possible.

2. Data Circuits - Local or Long distance data circuits at different speeds viz. 2.4Kbps,4.8Kbps, 9.6K bps, 64 kbps, nx64 kbps and 2 Mbps.

For internal circulation of BSNLonly

TYPE OF LEASED CIRCUIT SERVICES

Telegraph Circuits:- Local and Long distance Tele- printer Circuits. International Leased Circuits:- Provided through

VSNL.

For internal circulation of BSNLonly

TYPE OF LEASED CIRCUIT SERVICES


Point-to-Point Data Circuits - Local and Long distance. Private Data Network - More than one Local or Long distance leased circuits.

converging on a location such that data from one


leased circuit can be transferred automatically to another leased circuit for the same subscriber.

For internal circulation of BSNLonly

What is TVARIT ?
TVARIT is Sanskrit word for the term IMMEDIATE. TVARIT is LEASED LINE ONLINE provisioning and upkeep system. It is computerized online system, simple to operate & self explanatory. Paperless. Reliable, Fast and Instant execution of transactions. All the manual activities are computerized.

For internal circulation of BSNLonly

NUMBERING SCHEME OF LEASED CIRCUIT

Every leased circuit will have a number as

ABCD/JKL/XY/EFGH
WHERE ABCD= originating SDCA code EFGH= Terminating SDCA code

JKL = Circuit number


XY = Circuit type

For internal circulation of BSNLonly

NUMBERING SCHEME OF LEASED CIRCUIT


For circuit within the same SDCA,ABCD=EFGH
For 3 digit code, D= # and H= # For 2 digit code, C, D, = # and G, H = #

For 3 digit SDCA code, for JKL = 000 to 999,


the circuit number will be ABC#/JKL/XY/EFGH

For internal circulation of BSNLonly

NUMBERING SCHEME OF LEASED CIRCUIT


For the circuit falling between 1000 to 1999 in SDCA with 2 digit code (i.e. JKL = 1000 to 1999), Value of D = * & C = # and the circuit number will become AB#/*JKL/XY/EFGH For the circuit falling between 2000 to 2999 in SDCA with 2 digit code (i.e. JKL = 2000 to 2999), Value of C = * & D= * and the circuit number will become AB/**JKL/XY/EFGH

For internal circulation of BSNLonly

XY codes of Tvarit
11 12 13 14 15 16 17 18 19 20 21 Speech circuit (with HOT line relay set) Speech circuit (on PAX) Speech-cum-data circuit Voice grade data circuit VFT 64 kbps circuit N x 64 kbps circuits 2 Mbps circuit 8 Mbps circuit 34 Mbps circuit 140 Mbps circuit

For internal circulation of BSNLonly

XY codes Tvarit
22 23 24 25 26 27 28 29 30 31 STM-1 STM-4 STM-16 STM-64 R&G copper cable R&G OFC cable R&G UHF microwave Contribution work copper cable Contribution work OFC Contribution work UHF microwave

Any additional series code, (XY) will be centrally allotted

For internal circulation of BSNLonly

HOW TO ACCESS TVARIT


TVARIT is accessible by : PSTN DIAL-UP ( 022-22670080)

ISDN DIAL-UP ( 022 22639280 / 22639310 / 22639340 / 22639420)


LEASED LINE ( 64 Kbps / 2 Mbps ) (LAN-WAN connectivity) Launch Internet explorer Write http://10.10.0.1/admin in the address bar The home page will be opened Enter valid username and password. Home page of the user will be opened. Carry out the required tasks by following the on-line menus

For internal circulation of BSNLonly

Key Features of TVARIT System


Generation of the standard 13 digit unique number. Generation of the Provisional and final demand notes, Advice notes, Receipts and other general feasibility and channel allocation reports. Generation of Recurring bill. Generation of a full fledge Managerial Information Reports (MIS) . Current accurate status viewing to all the concern authorities. Address change and cancellation of the circuits