Sei sulla pagina 1di 4

GC Inlet Liners/ Glass Inser ts

Shimadzu Gas Chromatography

Part #
Split Mode 220-90784-00 220-90784-25 220-90816-01

GC Model

Description

Deactivated?

Wool? Qty.

Bottom ----------------------- Top

17A, 2010, 2014 17A, 2010, 2014 17A, 2010, 2014

Multi-purpose Split Liner, deactivated wool 35mm from top. Multi-purpose Split Liner, deactivated wool 35mm from top. Multi-purpose Split Liner with special siltek coating, deactivated wool 35mm from top. Multi-purpose Split Liner with special siltek coating, deactivated wool 35mm from top. Multipuropse split liner, more wool provides better reproducibility for higher mw compounds Low cost version of 220-90784-00 without wool. Not silanized. Good for use with stable, non-reactive compounds. General purpose low cost splitless liner. General use splitless liner, wool placement high for greater thermal mass helps volatize higher mw compounds. This is the stock liner in new GC instruments. This liner used in installation performance testing. General use splitless liner, wool placement low to minimize compound degradation and filter non-volatile components. This is the stock liner in new GCMS instruments. Drilled Uniliner, hole near the top. Splitless analysis for Chlorinated Pesticides, Aqueous Injections and compounds of interest that elute away from tailing solvent peak. Drilled Uniliner, hole near the bottom. Splitless analysis for volatile compounds that elute near the tailing solvent peak. Drilled Uniliner, hole near the top. Splitless analysis for Chlorinated Pesticides, Aqueous Injections and compounds of interest that elute away from tailing solvent peak. Top restriction holds sample cloud for greater column loading. Drilled Uniliner, hole near the bottom. Splitless analysis for volatile compounds that elute near the tailing solvent peak. Top restriction holds sample cloud for greater column loading.

Y Y Y-Siltek

Y Y Y

5/pk. 25/pk. 5/pk.

220-90816-25

17A, 2010, 2014

Y-Siltek

25/pk.

220-94766-00

17A, 2010, 2014

5/pk.

221-41444-01

17A, 2010, 2014

each

Splitless Mode 220-94767-00 221-48876-02 17A, 2010, 2014 17A, 2010, 2014 Y Y Y Y 5/pk. 5/pk.

221-48876-03

17A, 2010, 2014

5/pk.

220-94734-01

17A, 2010, 2014

5/pk.

220-94734-02

17A, 2010, 2014

5/pk.

220-94734-03

17A, 2010, 2014

5/pk.

220-94734-04

17A, 2010, 2014

5/pk.

Order online at http://store2.shimadzu.com/ or call 1 (800) 477-1227

Part #

GC Model

Description

Deactivated?

Wool?

Qty.

Bottom ----------------------- Top

Direct-Wide Bore Capillary Column Mode 220-94768-00 220-94735-01 17A, 2010, 2014 17A, 2010, 2014 General purpose megabore (0.53 mm ID) column, direct injection liner. General purpose w/Wool, for dirty samples wool acts as a filter for non volatile components in sample. FID, ECD, FPD and FTD. 87 mm long. FID, TCD, ECD, FPD and FTD. 139 mm long. General use glass packed column liner. 83 mm long. FID, ECD, FPD and FTD. 87 mm long. TCD only. 87 mm long. FID, TCD, ECD, FPD and FTD. 139 mm long. PTV liner, Quartz glass for inert performance, reduces catalytic degradation of reactive compounds. PTV liner, general use. Siltek Deactivated for PTV-17. PTV liner, Quartz glass for inert performance, reduces catalytic degradation of reactive compounds. Metal insert for 0.53 ID column, Oncolumn Adapter Metal insert for 0.53 ID column, Oncolumn Adapter Use this liner for Purge and Trap or SPME applications. For Simple On-column or Near Oncolumn use in the OCI 2010. Columns with a smaller than 0.53 mm ID can be used with this liner, no pre-column needed. N N Y Y N Y 5/pk. 5/pk.

Direct-Stainless Steel Packed Column Mode 221-48886-00 221-14093-00 2010 2014 (Packed Inj.) N N N N each each

Direct-Glass Packed Column Mode 221-41484-00 221-48886-00 221-48993-00 221-14093-00 17A 2010 2010 2014 (Packed Inj.) N N N N N N N N each each each each

PTV (Programmed Temperature Vaporization) Mode 221-42223-00 17A N N each

220-90816-03 220-90816-02 221-49300-00

17A 17A 2010

Y Y-Siltek

Y Y N

5/pk. 5/pk. each

OCI (On Column Injection) Mode 221-42222-91 221-49298-91 17A 2010 N N each each

SPME, P&T, Narrow Bore Capillary Column (Fast GC) Mode 220-94769-00 17A, 2010, 2014 Y N 5/pk.

Simple OCI (Near On Column) Mode 221-49381-02 2010 Y N each

Order online at http://store2.shimadzu.com/ or call 1 (800) 477-1227

GC Excellence, Plus
Realize dramatic improvements in productivity with the new GC-2010 Plus. Out of the box, its ready to perform high-speed GC utilizing the latest in ultra narrow-bore capillary columns. The fourth generation Advanced Flow Controller delivers up to 1200 ml/min, 140 psi of pressure and supports split ratios of 9000:1. With fast data collection and rapid cooling, the ultimate in fast GC capabilities has arrived. Combined with world-class sensitivity limits, its simple: the new GC-2010 Plus is the clear winner.

The GC-2010 Plus features:


New family of best-in-class detectors addresses increasing sensitivity demands for trace-level analysis Rapid oven cooling Long-term stability of retention times Excellent precision Advanced Flow Technology Accessories Reduce analysis times, provide enhanced chromatographic resolution, and enable application-specific configurations without compromising performance: Multidimensional GC delivers enhanced separation power, making it ideal for complex matrices Backflush shortens run times for improved productivity Detector Splitting Saves time/money, and enables confident peak identification

Founded in 1875, Shimadzu Corporation, a leader in the development of advanced technologies, has a distinguished history of innovation built on the foundation of contributing to society through science and technology. We maintain a global network of sales, service, technical support and applications centers on six continents, and have established long-term relationships with a host of highly trained distributors located in over 100 countries. For information about Shimadzu, and to contact your local office, please visit our Web site at www.shimadzu.com.

SHIMADZU CORPORATION International Marketing Division

3. Kanda-Nishikicho 1-chome, Chiyoda-ku, Tokyo 101-8448, Japan Phone: 81(3)3219-5641, Fax: 81(3)3219-5710 URL: www.shimadzu.com

SHIMADZU SCIENTIFIC INSTRUMENTS, INC.

7102 Riverwood Drive, Columbia, Maryland 21046, U.S.A. Phone: 800-477-1227/410-381-1227, Fax: 410-381-1222 URL: www.ssi.shimadzu.com

Potrebbero piacerti anche