eld-mounted instruments that incorporate a exible modular design providing cost effective sensing solutions. The two-piece piston design allows for complete differential pressure reversal without damage. See Principle description on page 2.
Basic models with standard wetted parts are normally suitable for air, oil, water and non-corrosive process uids. See the Quick Selection Guide on page 4. Corrosive service and special requirements may require optional components. See How to Order on page 3. Series 101/121 differential pressure switches are suited for low-to-high differential pressure, uid power or process applications where high and varying static pressures, high overrange, proof, shock pressure or cycle rates are expected. 101NN 121NN
Application Information
101AG 121AG
101L 121L
Principle
Fl
Fh = Force, Hi Pressure Fl = Force, Lo Pressure Fs = Force, Range Spring Fd Fd = Force, Resultant Differential Fd = Fh - (Fl + Fs)
Process pressure is sensed by a diaphragm-piston combination. Hi-side system pressure acts on the piston to product force Fh. It is counteracted by the adjustable range spring force Fs and Lo-side system pressure acting on the backside of the piston to produce force Fl . The resultant force Fd acts on the piston and overcomes the force of the adjustable range spring [Fd = Fh (Fl + Fs)] and moves a shaft that actuates (deactuates) an electrical switching element.
Fh A
Fs
Delivery Routine shipments 7 to 10 working days. Emergency shipments via air same day.
Construction Rugged, high cycle rate tolerance, long life, not critical to vibration, high overrange and proof pressures, withstands full Hi and Lo side pressure reversals, excellent corrosion resistance to hostile environments.
Service Factory service engineers and area factory representatives provide effective and prompt worldwide service.
Instrument Quality High repeatability, narrow dead band, negligible temperature effect and static inuence.
Field Adjustable Excellent resolution of Set Points, adjustment, no special tools required. No-charge factory calibration.
Safety Certied to IEC 61508 (SIL) SOR products are certied to IEC 61508 for non-redundant use in SIL1 and SIL2 Safety Instrumented Systems for most models. For more details or values applicable to a specic product, see the Safety Integrity Level Quick Guide (Form 1528).
UL, CSA, ATEX, GOST Approved Models Meets most code and customer requirements.
Form 468
2/20
sorinc.com 913-888-2630
How to Order
101NN-K3-N4-C1A-YY
Series Housing Switching Adjustable Element Range Diaphragm & O-Ring Pressure Port Accessories
Basic Series 101/121 differential pressure switches with standard wetted parts are normally suitable for air, oil, water and non-corrosive processes. Refer to the Quick Selection Guide section on page 4. Corrosive service and particular customer requirements may require optional components. Refer to the How to Order section on this page or the dedicated page to locate optional components, such as: housings, switching elements, diaphragm systems, pressure ports and accessories. Each position in the model number, except Accessories, must have a designator. The Series 101/121 differential pressure switches in this catalog are suitable for a wide variety of process and uid power applications. Specic application requirements can normally be met by selecting optional components, such as, switching elements and diaphragm systems. Certain applications may require customized specials. Consult local representative or the factory. Weathertight, conventional explosion proof and hermetically sealed explosion proof models are presented in this catalog.
Applications
Steps 1 through 5 are required; Step 6 is optional. Orders must have complete model numbers, i.e. each component must have a designator. Order information must include: a) Set Point (increasing or decreasing) b) If decreasing Set Point, state from what greater Set Point is approached c) Normal system (static) pressure Step 1: Select Housing for type of service (pages 5 & 6). Step 2: Select electrical Switching Element for housing and electrical service (pages 6 & 7). Step 3: Select Adjustable Range according to Set Point (page 8). Step 4: Select Diaphragm and O-Ring for process compatibility and containment (page 9). Step 5: Select Pressure Port for process connection (page 9). Step 6: Select Accessories as required for service (page 10). If Agency Listed, Certied or Approved differential pressure switches are required, see page 11 for components that must be specied.
sorinc.com 913-888-2630 Form 468 Registered Quality System to ISO 9001 :2008
How to Order
3/20
Principle
Model Number
Range (psid)
Electrical Rating
Electrical Connection
Housing Material
101NN - K3 - N4 -C1A
3 to 30
10 to 75
1.5
3/4 NPT(F)
Aluminum
75 to 500
10
101L - K3 - N4 - C1A
3 to 30
10 to 75
1.5
3/4 NPT(F)
Cast Iron
75 to 500
10
3 to 30
10 to 75
3.0
Aluminum
75 to 500
20
Product Specications
Pressure Port Maximum Working Pressure 101 121 1/4 NPT(F) 500 psi 1,000 psi Wetted Materials Diaphragm O-Ring Pressure Connection Teon-Coated Polyimide Buna-N 316SS; CF-8M Cast Alloy
Design and specications are subject to change without notice. For latest revision, see www.sorinc.com.
Form 468
4/20
sorinc.com 913-888-2630
Step 1: Housing
101NN-K3-N4-C1A-YY
PP
P3
Open bracket with exposed switching element does not meet NEMA 1.
See Agency Listings page 11. See Switching Element Groups 1, 2, 3, 4 page 6.
H3
NN
See Agency Listings page 11. See Switching Element Groups 1, 2, 3, 4 page 6.
N3
Electrical: 3/4 NPT(F)- Right Material: Aluminum Cover: heavy duty with Viton gasket
See Agency Listings page 11. See Switching Element Groups 1, 2, 3, 4 page 6.
See Agency Listings page 11. See Switching Element Groups 1, 2, 3, 4 page 6.
N4
N6
See Switching Element Groups 1 & 3 page 6.
RN RM
Electrical - RN: 3/4 NPT(F)-Right Electrical - RM: M20 x 1 .5 - Right Six-place compression type terminal block. Material: Aluminum
See Agency Listings page 11. Switching Element Groups 1, 2, 3, 4, 5 page 6.
RT RS
Electrical-RT: 3/4 NPT(F)-Right Electrical-RS: M20 x 1.5-Right Six-place compression type terminal block Material: 316SS
See Agency Listings page 11. Switching Element Groups 1, 2, 3, 4, 5 page 6.
Electrical: 3/4 NPT(F)-Right Manual reset only Six-place compression type terminal block Material: Aluminum
See Agency Listings page 11. See Switching Element Group 7 page 6.
RB
See Switching Element Group 5 page 6. UL Listed Class I, Groups C & D; Class II, Groups E, F & G; Divisions 1 & 2 as an outlet box only. Electrical: 3/4 NPT(F)-Right Material: Cast Iron Weathertight with Option CG
AG
See Switching Element Group 5 page 6. UL Listed Class I, Groups C & D; Class II, Groups E, F & G; Divisions 1 & 2 as an outlet box only. Electrical: 3/4 NPT(F)-Right Six-place compression type terminal block with Option LL Material: Copper-free** aluminum Weathertight
AH
Material: 316SS
*BA
See Switching Element Groups 1 & 3 page 6. UL Listed Class I, Groups C & D; Class II, Groups E, F & G; Divisions 1 & 2 as an outlet box only. Electrical: 3/4 NPT(F)-Left, Right, Top Material: Cast Iron Weathertight with Option CG
*L
See Switching Element Groups 1, 2, 3, 4 page 6. UL Listed Class I, Groups C & D; Class II, Groups E, F & G; Divisions *B3 1 & 2 as an outlet box only. Electrical: 3/4 NPT(F)-Left, Right, Top Six-place compression type *B4 terminal block with Optional LL Material: Copper-free** aluminum Weathertight
*LC
*S
See Switching Element Groups 1, 2, 3, 4, 7 page 6. See Switching Element Groups 1 , 3, 7 page 6. Class I, Groups A, B, C, D; Class II, Groups E, F, G; Divisions 1 & 2 as an outlet box only. Electrical: 3/4 NPT(F)-Left, Right, Top Material (Housing): Aluminum Material (Cover): Aluminum Line Mounted. Weathertight with Option CG. *TA See Switching Element Groups 1 & 3 page 6.
*SC
*B5 *B6
* Not recommended for direct mount where vibration is expected. Housing should be securely mounted to a at surface (bulkhead or panel rack) or pipe stanchion. ** Consult the factory.
sorinc.com 913-888-2630 Form 468 Registered Quality System to ISO 9001 :2008
5/20
Principle
Step 1: Housing
101NN-K3-N4-C1A-YY
Group 5
Group 4
Group 7
A, AA, B, BB, C*, E, GG, KK, LL, YY T EE, G, J, JJ, K, KA, L, S, W, Y *C micro switch is not available in L, S, and TA housings
D, M
101NN-K3-N4-C1A-YY
Dead Band Multiplier SPDT 1 1 1.5 2 2 2.5 1.5 3.5 DPDT 4 3.5 4 4 4.5 3 Designator SPDT K KA J G A L E C DPDT KK N/A JJ GG AA LL EE N/A
Switching Element Service Normal Service AC Low Power Gold Contacts Wide Dead Band AC AC or DC Wide Dead Band DC Narrow Dead Band DC Very Wide Dead Band DC Very HighCapacity DC Magnetic Blow-Out Hi-Ambient Temperature Rating - 400F Wide Adjustable Dead Band Narrow Adjustable Dead Band Manual Reset Decreasing Pressure (Automatic Actuation Increasing Pressure) Manual Reset Increasing Pressure (Automatic Actuation Decreasing Pressure) Corrosion Resistant Explosion Proof Hermetically Sealed Switching Element Corrosion Resistant Explosion Proof Lower Power Service Hermetically Sealed Gold Contacts ATEX Approved II 2 G EEx d IIC Microswitch Only Form 468
Volts 30 28 30 30 30 30 -
Amps 5* 1* 1 5 10* 5* -
Single Switching Element SPDT -(1) SPDT Double Switching Element DPDT - (2) SPDT Simultaneous actuation/deactuation at increasing/decreasing Set Points.
K, KA, G, L, C, N, S, Y, W Switching Elements - Screw Terminals. All other switching elements - 18 18 AWG color-coded wire leads except when terminal blocks are specied.
10 5 5 5 15 15
10 .3
4 3.5 -
S B Y W T H
D 250 15 125 .5 1.5 M 250 250 250 250 125 125 125 15 5 11 5 1 1 1 125 125 125 125 .4* .5* .5 .5* 30 30 30 30 28 30 30 5* 5* 5 5* 1* 1 1 1.5 3 2 1.5 2.5 3.5 5 3.5 4 4 KB N/A AF EF JR N/A JF
N/A
250
250
0.25
30
BD
N/A
Cross reference compatibility chart above to ensure that switching element will t in housing. 6/20
Registered Quality System to ISO 9001 :2008
sorinc.com 913-888-2630
101NN-K3-N4-C1A-YY
4. DPDT switching elements have wire leads except when supplied in housings RN, RT, RM, RS, RB, B3, B4, B5, B6. 5. Switching element minimum/maximum ambient temperatures: -40 to 167oF (-40 to 75oC) AF, AG, EB, EF, EG, JB, JF, JG, JR, KB -65 to 400oF (-54 to 204oC) B, Y, W -65 to 250oF (-54 to 120oC) A, E, J -65 to 180oF (-54 to 80oC) All others 6. Dead band multipliers must be applied to the typical dead band gures given in the specication tables on page 8. 7. Switching elements B, W and Y have an Elgiloy spring. Experience indicates good service in atmospheres with corrosive gases - H2S, ammonia, etc. CAUTION: The switching element assembly has been precisely positioned in the housing at the factory for optimum performance. Any inadvertent movement or replacement in the eld will degrade performance, could render the device inoperative and may void the warranty unless factory authorized procedures are followed.
Designator
AF, EF, AG, EG, KB, EB, JB, JF, JG, JR AF, EF, AG, EG, KB, EB AF, EF, AG, EG, JF, JG
3. DC electrical ratings are for resistive loads only. DC ratings marked with an asterisk (*) are not agency recognized or certied but have been veried by testing or experience.
sorinc.com 913-888-2630
7/20
101NN-K3-N4-C1A-YY
This table lists designators for corresponding adjustable ranges, dead bands, maximum system pressure and maximum differential pressure. Adjustable range is expressed for increasing pressure: the Set Point must be within the adjustable range. Dead band is expressed as typical at mid-range. See dead band considerations at the bottom of this page.
Series and 4th Designator
(see example)
Adjustable Range
(increasing pressure)
psid 3 to 30 10 to 75 75 to 500
45 45
Notes 1. Ambient temperature range: -30 to 180oF (-34 to 80oC). Check restrictions, page 7, for optional electrical switching elements and page 9 for optional diaphragm systems. 2. Metric bar (mbar) values are practical equivalents of the mathematical conversions. This data appears on the product nameplate when metric engineering units are specied.
3. CAUTION: When the process could be considered dirty in terms of suspended particles, it is recommended that 20-micron in-line lters be installed on the Hi and Lo pressure ports. 4. To achieve optimum performance, the 101/121 should be calibrated under simulated system operating conditions.
Dead Band Multiplier 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 2.5 to 5.0 1.0 to 3.0
sorinc.com 913-888-2630
8/20
101NN-K3-N4-C1A-YY
Designator H4 M2 M4 N1
Standard
N4 S1
Notes 1. N4 diaphragm system is standard. It is normally suitable for air, oil, water and non-corrosive processes. 2. Other diaphragm and o-ring combinations may be available. Consult the factory or the SOR representative in your area for more information. 3. Wetted parts have been selected as representing the most suitable commercially available material for use in the service intended. However, they do not constitute a guarantee against corrosion or permeation, since processes vary from plant to plant and concentration of harmful uids, gases or solids vary from time to time in a given process. Empirical experience by users should be the nal guide. Alternate materials based on this are generally available.
4. Differential pressures exceeding 100 psid may affect Set Point when M2, M4, or H4 diaphragm and o-ring combination is used. 5. Dead bands are higher when using metal diaphragm options. Consult the factory. 6. This table shows allowable minimum and maximum temperatures for o-rings.
101NN-K3-N4-C1A-YY
Material 316SS; CF-8M Cast Alloy Connection Size 1/4 NPT(F) 1/4 BSP(F) Designator C1A C1B
Notes 1. C1A pressure port is standard. It is normally suitable for air, oil, water and non-corrosive processes.
2. Other pressure port materials and connection sizes may be available. Consult the factory or the SOR representative in your area for more information.
sorinc.com 913-888-2630
9/20
Step 6: Accessories
101NN-K3-N4-C1A-YY
Designator
BB CL CS CG CV DS GC GG KK LL ML PK PP PY RR SB TB TT VV WV X YY ZZ
CSA Certied differential pressure switch. Available with PP, NN, RB, RN, RT, B3 and B6. Housing has earth (ground) lug. See Agency Listings on page 11 for details. Neoprene cover gasket (o-ring) to make L, S and TA explosion proof housings weathertight. Canadian Registration Number (CRN) - Process ratings may be affected. Consult the factory for details. CSA Dual Seal Approval. See Agency Listings on page 11 for details Cemented cover gasket on weathertight housings. Sealed electrical lead adapter. Provides protection to housing interior, switching element and dry side of pressure sensing assembly from condensate in the electrical conduit and corrosive atmospheres. (Protrudes approximately 2 from housing.) Breather Drain Crouse Hinds ECD-15 for Hazardous Locations Class I, Groups C & D, Class II, Groups E, F & G; on S or SC housings only. Sintered metal plug in weathertight housing.
Terminal block. 6-place compression type standard in B and R series housings. Optional in LC and SC housings. Multi-Listed differential pressure switch. ATEX, CSA & UL. Available with B3 & B6 housings. See Agency Listings on page 11 for details. Pipe (stanchion) mounting kit for (1-1/2 to 2 pipe). Order as a separate line item for UL Listed and CSA Certied pressure switches. Tag, ber. Attached with plastic wire to housing. Stamped with customer specied tagging information. Powder coat epoxy coating. No coating on stainless steel parts or plated screws. (500 hours-salt spray) Tag, stainless steel. Attached with stainless steel wire to housing. Stamped with customer specied tagging information. (2 lines, 18 characters and spaces per line.) Stainless steel body, force transmitter and adjusting nut for corrosive environments. Standard on stainless steel housings. Explosion proof weathertight electrical junction box with screw terminals. Aluminum 3/4 NPT(F) top or right conduit connections as required. UL Listed and CSA Certied Class I, Groups A, B, C & D; Class II, Groups E, F & G; Divisions 1 & 2. (L, LC, S, SC and TA housing.) Includes cover o-ring for weathertight applications. Oversize stainless steel nameplate or separate stainless steel tag. Permanently attached to housing. Stamped with customer specied tagging information. Fungicidal varnish. Covers exterior and interior except working parts. UL Listed differential pressure switch. Available with B3 and B6 housings. See Agency Listings on page 11 for details. X is used as a sufx to the model number for special requirements not keyed elsewhere in the model number by an X. Each X must by completely identied in the text of the order or inquiry. When more than one X is required, use X followed by the number of such items. For example, X3 means three separate otherwise unidentiable requirements. Epoxy coating. Exterior only. Polyamide epoxy with 316SS pigment (200 hours-salt spray). Chained cover with captive screws to conform to former JIC specication.
Representative Information Only: A slash and a three-digit number (/000) appearing after the last accessory designator letter in the model number denotes special administrative procedures with respect to factory representatives. It is not part of the model number and is used only by the factory or a factory representative.
Test Certicates
Certicates Calibration Hydrostatic Pressure Test Inspection Report Compliance / Conformance Dielectric Test Insulation Resistance Typical Material of Wetted Parts Form 468 C1 C2
C3
C4
C5
C6
C8
B1
B4
B5
B6
B7
A1
A2
A3
A4
A5
A6
A7
A8
10/20
sorinc.com 913-888-2630
Agency Listings
For Hazardous Locations Class I Groups B, C, D; Class II, Groups E, F, G; Divisions 1 & 2 Pressure Port Material & Connection Size Accessories WV or ML Required ALL ALL ALL All except CG, GC, GG, HB, HT, KK, LL, ME, TB, ZZ
ALL
B3, B6
CSA
For Hazardous Locations Class I, Groups A, B, C, D; Class II, Groups E, F, G; Divisions 1 & 2 Piston Housing Switching Element A, AA, AF, AG, B, BB, C, E, EE, EF, EG, G, GG, H, J, JF, JG, JJ, K, KA, KK, L, LL, P, S, T, W, Y, YY Spring Diaphragm & O-Ring Pressure Port Material & Connection Size Accessory CS or ML Required ALL ALL ALL All except CG, GC, GG, HB, HT, KK, LL, ME, TB, ZZ
ALL
B3, B6
For General Purpose and Weathertight (CSA Enclosed 4) PP (General Purpose) NN (Enclosed 4), N6 101 RN (Enclosed 4) RM, RT, RS RB (Enclosed 4) For Dual Seal Approval ALL AG, AH AF, AG, EF, EG, JF, JG ALL M2, M4, N4 C1A, C2A DS Required CV, PP, RR, TT, YY A, AA, B, BB, C, E, EE, G, GG, GA, H, J, JJ, JL, K, KK, KA, L, LL, N, S, T, W, Y, YY A, AA, AF, AG, B, BB, C, E, EE, EF, EG, G, GG, GA, H, J, JJ, JL, JF, JG, K, KK, KA, L, LL, N, S, T, W, Y, YY D, DA, M (Manual Reset only) ALL ALL ALL CS Required
ATEX
EEx d IIC T6/T5 Piston Housing Switching Element Spring Diaphragm & O-Ring Pressure Port Material & Connection Size Accessory CL (for all Hsgs) or ML (for B3/B6 Hsgs) Required ALL ALL ALL All except CG, GC, GG, HB, HT, KK, LL, ME, TB, ZZ
ALL
A, AA, AF, AG, B, BB, C, E, EE, EF, EG, G, GG, H, J, JF, JG, JJ, K, KA, KK, L, LL, P, S, T, W, Y, YY
Ex ia IIC T6...T4 Gb ALL RN, RM, RT, RS J, JJ, JF, JG ALL ALL ALL CL
sorinc.com 913-888-2630
11/20
Manual Reset
101RB-D3-N4-C1A-YY
Series 101/121 Differential Pressure Switches in this catalog may be specied with manual reset electrical switching elements D or M. D actuates automatically on increasing pressure. M actuates automatically on decreasing pressure. Depress the button, covered by the weathertight boot to manually reset. Housings must be RB weathertight or S explosion proof because of the requirement of a hub for the manual reset assembly. Refer to page 3 for order instructions. RB-Weathertight S-Explosion Proof
Approximate Weights
Housing AG, H3 AH, NN, N3, N4, PP, P3 RM, RN BA, N6, RB RT L, LC, SC TA B3. B4 B5, B6 Weight (lbs.) 2.5 3 3.5 4 4.5 5 5.5 9 11 (kgs) 1.25 1.5 1.75 2 2.25 2.5 2.75 4.5 5.5 Accessory PK Pipe Kit TB Junction Box with Terminal Block Add (lbs.) 1.5 5 (kgs) 0.7 2.25
Actual shipping weights may vary from the charted values because of product material, conguration and packaging requirements.
Form 468
12/20
sorinc.com 913-888-2630
Glossary of Terms
SOR recognizes that there is no industry convention with respect to terminology and denitions pertinent to pressure switches. This glossary applies to SOR Pressure Switches. Adjustable Range The span of pressure between upper and lower limits within which the pressure switch may be adjusted to actuate/deactuate. It is expressed for increasing differential pressure. Dead Band The difference in pressure between the increasing Set Point and the decreasing Set Point. It is expressed as typical, which is an average with the increasing Set Point at midadjustable range for a pressure switch with the standard K switching element. It is normally xed (nonadjustable). Differential Pressure Switch A bi-stable electromechanical device that actuates/deactuates one or more electrical switching element(s) at a predetermined discrete differential pressure (Set Point) upon rising or falling differential pressure. DPDT Switching Element DPDT is two synchronized SPDT switching elements that actuate together at increasing Set Point and deactuate together at decreasing Set Point. Discrete SPDT switching elements allow two independent circuits to be switched; i.e., one AC and one DC. The synchronization linkage is factory set, and is not eld adjustable. Synchronization is veried by connecting test lamps to the switching elements and observing them go On simultaneously at actuation and Off simultaneously at deactuation Hermetically Sealed A welded steel capsule with glass-to-metal, factory-sealed, electrical leads that isolates the electrical switching element(s) from the environment. Maximum Differential Pressure The maximum difference in pressure that may be continuously applied between the Hi and Lo (Lo and Hi) pressure ports without causing permanent change of Set Point, leakage or material failure. Overrange The maximum input pressure that may be continuously applied to the pressure switch without causing permanent change of Set Point, leakage or material failure. Proof Pressure The maximum input pressure that may be continuously applied to the pressure switch without causing leakage or catastrophic material failure. Permanent change of Set Points may occur, or the device may be rendered inoperative. Repeatability The ability of a pressure switch to successively operate at a Set Point that is approached from a starting point in the same direction and returns to the starting point over three consecutive cycles to establish a pressure prole. The closeness of the measured Set Point values is normally expressed as a percentage of full scale (maximum adjustable range pressure). Set Point That discrete pressure at which the pressure switch is adjusted to actuate/deactuate on rising or falling pressure. It must fall within the adjustable range and be called out as increasing or decreasing differential pressure. SPDT Switching Element Single-Pole, Double Throw (SPDT) has three connections: C Common, NO Normally Open and NC Normally Closed, which allows the switching element to be electrically connected to the circuit in either NO or NC state.
Form 468 Registered Quality System to ISO 9001 :2008
sorinc.com 913-888-2630
13/20
Dimensions
Dimensions in this catalog are for reference only. They may be changed without notice. Contact the factory for certied drawings for a particular model number. Dimensions are expressed as millimeters over inches (Linear = mm/in.)
Drawing 0090603
Housing: N6
SALES PAGE MODEL # SALES ORDER # LINE ITEM # PURCHASE ORDER #
1
108.1 4.25 52.4 2.06 69.9 2.75 33.3 1.31 ** 56.5 2.22 28.6 1.13 26.1 1.03
ELECTRICAL CONNECTION 3/4 NPTF STD 1/2 NPTF OPT (BOTH SIDES ON N3 & P3 HSGS)
PROCESS CONNECTION SIZE 1/4 NPTM SHOWN 1/2 NPTF 1/2 NPTM 3/4 NPTF
154.1 6.07
CLEARANCE SLOTS 6.4 FOR HARDWARE WITH 0.25 63.5 76.2 MIN TO MAX 2.50 3.00 MOUNTING CENTERS
40.5 1.59
7.1 0.28
ISO-9001
PRODUCT CERTIFICATION DRAWING ALL DIMENSIONS ARE 1/16 IN UNLESS OTHERWISE SPECIFIED MM LINEAR = IN
K MITCHELL
CHECKED BY
J REHM
ENGINEER APPROVAL
J MODIG
DATE
A TYP
10 OCT 2011
THIS DRAWING IS THE EXCLUSIVE PROPERTY OF SOR. NO USE WHATSOEVER OF THE INFORMATION CONTAINED HEREON, NOR REPRODUCTION IN WHOLE OR PART MAY BE MADE WITHOUT THE EXPRESS WRITTEN PERMISSION OF SOR.
Drawing 0090602
Form 468
38.1 1.50
60.3 2.38
SCALE: 1.00
DO NOT SCALE PRINT
0090602 SHEET 1 OF 1
3
DWG SIZE
Reset Form
Dimensions
Dimensions in this catalog are for reference only. They may be changed without notice. Contact the factory for certied drawings for a particular model number. Dimensions are expressed as millimeters over inches (Linear = mm/in.)
Drawing 0090604
SALES PAGE
107.3 4.22 52.0 2.05 69.9 2.75 33.3 1.31 65.6 2.58 28.6 1.12 26.2 1.03 HOUSING RL RM RN ELECTRICAL CONNECTION SEE CHART RS RT ELECTRICAL CONNECTION 3/4 NPTF STD 1/2 NPTF OPT LH & RH M20 X 1.5 F RH ONLY 3/4 NPTF STD 1/2 NPTF OPT RH ONLY M20 X 1.5 F RH ONLY 3/4 NPTF STD 1/2 NPTF OPT RH ONLY 3/4 NPTF STD 1/2 NPTF OPT LH & RH M20 X 1.5 F LH & RH M20 X 1.5 F LH & RH
RU 40.5 1.59 RW RY
61.9 2.44 28.6 1.13 1/4 NPTF HI SIDE PROCESS CONNECTION 1/4 NPTM PROCESS CONNECTION OPTIONAL
ISO-9001
PRODUCT CERTIFICATION DRAWING ALL DIMENSIONS ARE 1/16 IN UNLESS OTHERWISE SPECIFIED MM LINEAR = IN
K MITCHELL
CHECKED BY
M SMITH S BOAL
DATE
ENGINEER APPROVA
17 OCT 201
THIS DRAWING IS THE EXCLUSIVE PROPERTY OF SOR. NO USE WHATSOEVER OF THE INFORMATION CONTAINED HEREON, NOR REPRODUCTION IN WHOLE OR PART MAY BE MADE WITHOUT THE EXPRESS WRITTEN PERMISSION OF SOR.
TITLE
Drawing 0090605
38.1 1.50
7.1 0.28
DRAWING NUMBER
REV
0090605 SHEET 1 OF 1
DWG
Reset F
sorinc.com 913-888-2630
15/20
Dimensions
Dimensions in this catalog are for reference only. They may be changed without notice. Contact the factory for certied drawings for a particular model number. Dimensions are expressed as millimeters over inches (Linear = mm/in.)
Drawing 0090601
108.1 4.25 52.4 2.06 69.9 2.75 33.3 1.31 ** 56.5 2.22 28.6 1.13 26.1 1.03
ELECTRICAL CONNECTION 3/4 NPTF STD 1/2 NPTF OPT (BOTH SIDES ON N3 & P3 HSGS)
PROCESS CONNECTION SIZE 1/4 NPTM SHOWN 1/2 NPTF 1/2 NPTM 3/4 NPTF
154.1 6.07
CLEARANCE SLOTS 6.4 FOR HARDWARE WITH 0.25 63.5 76.2 MIN TO MAX 2.50 3.00 MOUNTING CENTERS
40.5 1.59
7.1 0.28
ISO-9001
PRODUCT CERTIFICATION DRAWING ALL DIMENSIONS ARE 1/16 IN UNLESS OTHERWISE SPECIFIED MM LINEAR = IN
K MITCHELL
CHECKED BY
J REHM
ENGINEER APPROVAL
J MODIG
DATE
A TYP
10 OCT 2011
THIS DRAWING IS THE EXCLUSIVE PROPERTY OF SOR. NO USE WHATSOEVER OF THE INFORMATION CONTAINED HEREON, NOR REPRODUCTION IN WHOLE OR PART MAY BE MADE WITHOUT THE EXPRESS WRITTEN PERMISSION OF SOR.
Drawing 0090602
Model Name: 0090602.ASSEM/2/2
38.1 1.50
60.3 2.38
SCALE: 1.00
DO NOT SCALE PRINT
0090602 SHEET 1 OF 1
3
DWG SIZE
Reset Form
16/20
sorinc.com 913-888-2630
Dimensions
Dimensions in this catalog are for reference only. They may be changed without notice. Contact the factory for certied drawings for a particular model number. Dimensions are expressed as millimeters over inches (Linear = mm/in.)
MODEL #
SALES ORDER #
LINE ITEM #
PURCHASE ORDER #
106.4 4.19
Drawing 0090606
MODEL # Housing: L
34.0 1.34
8.7 0.34
PURCHASE ORDER #
LINE ITEM #
207.4 8.17
149.5 5.88 71.4 2.81 7.1 MOUNTING 54.0 0.28 2.13 HOLE (TYP 4) (TYP)
106.4 4.19
34.0 1.34
8.7 0.34
72.3 2.85
28.6 1.13
207.4 8.17
1/4 NPT(F) LO SIDE PROCESS CONNECTION 1/4 NPT(F) HI SIDE PROCESS CONNECTION 7.1 MOUNTING 0.28 HOLE (TYP 4)
ISO-9001
DRA
LENGTH A
29.7 1/4 NPT(M) = (SHOWN) 1.17 1/2 NPT(F) = 37.6 1.48 34.8 1.37
A (TYP)
126.2 4.97
38.1 1.50
PRODUCT CERTIFICATION DRAWING ALL DIMENSIONS ARE 1/16 IN UNLESS OTHERWISE SPECIFIED MM LINEAR = IN
CHE
JR
ENG
SB
DAT
THIS DRAWING IS THE EXCLUSIVE PROPERTY O NO USE WHATSOEVER OF THE INFORMATION CON HEREON, NOR REPRODUCTION IN WHOLE OR PAR MADE WITHOUT THE EXPRESS WRITTEN PERMISSIO
TITLE
1/2 NPT(M) =
72.3 2.85
14685 W 0091068
OF
ISO-9001 SHEET 1
LENGTH A
NPT(M) = (SHOWN) Drawing1/4 0091068 1.17 1/2 NPT(F)LC = Housing: 1.48 1/2 NPT(M) = sorinc.com 1.37 913-888-2630 39.9 3/4 NPT(F) = 1.57
Model Name: 0091068.ASSEM/3/0+
29.7
A (TYP)
38.1 1.50
LINEAR
37.6 34.8
TITLE
THIS DRAWING I NO USE WHATSOEV HEREON, NOR REPR MADE WITHOUT THE
17/20
Dimensions
Dimensions in this catalog are for reference only. They may be changed without notice. Contact the factory for certied drawings for a particular model number. Dimensions are expressed as millimeters over inches (Linear = mm/in.)
MODEL #
SALES ORDER #
LINE ITEM #
PURCHASE ORDER #
106.4 4.19
34.0 1.34
8.7 0.34
Drawing 0090607
7.78 MODEL # Housing: S 197.7
ELECTRICAL CONNECTION 3/4 NPT(F)(STD) 1/2 NPT(F)(OPT) OR PLUGGED(OPT) (TYP 3) SALES ORDER #
LINE ITEM #
PURCHASE ORDER #
126.2 4.97
72.3 2.85
142.9 5.63
7.1 MOUNTING 71.4 0.28 2.81 HOLE (TYP 4) 54.0 2.13 (TYP) 1/4 NPT(F) LO SIDE ELECTRICAL PROCESS CONNECTION CONNECTION 28.6 3/4 NPT(F)(STD) 1.13 1/4 NPT(F) HI SIDE 1/2 NPT(F)(OPT) PROCESS CONNECTION OR PLUGGED(OPT) (TYP 3)
106.4 4.19
34.0 1.34
8.7 0.34
ISO-9001
DRAW
LENGTH A
29.7 1/4 NPT(M) = (SHOWN) 1.17 1/2 NPT(F) = 37.6 1.48 34.8 1.37
38.1 1.50
PRODUCT CERTIFICATION DRAWING ALL DIMENSIONS ARE 1/16 IN UNLESS OTHERWISE SPECIFIED MM LINEAR = IN
MS
CHEC
J RE
ENGI
SB
DATE
126.2 4.97
THIS DRAWING IS THE EXCLUSIVE PROPERTY OF NO USE WHATSOEVER OF THE INFORMATION CON HEREON, NOR REPRODUCTION IN WHOLE OR PART MADE WITHOUT THE EXPRESS WRITTEN PERMISSION
TITLE
39.9 1.57
72.3 2.85
7.1 MOUNTING 0.28 HOLE (TYP 4) 1/4 NPT(F) LO SIDE PROCESS CONNECTION 28.6 1.13
DRAWING NUMBER
0090609 SHEET 1 OF
1468
ISO-9001
LENGTH A
A (TYP) 29.7
1/4 NPT(M) = (SHOWN) 1.17 Drawing 0090609 1/2 NPT(F) = Housing: SC 1.48 37.6 34.8 1.37
38.1 1.50
LINEA
Form 468
18/20
39.9 1.57
sorinc.com 913-888-2630
EO NUMBER: 509
Dimensions
Dimensions in this catalog are for reference only. They may be changed without notice. Contact the factory for certied drawings for a particular model number. Dimensions are expressed as millimeters over inches (Linear = mm/in.).
PURCHASE ORDER #
150.1 5.91 75.1 2.95 80.0 3.15 40.0 1.58 110.3 4.34 ELECTRICAL CONNECTION SEE CHART 35.3 1.39 9.5 0.38
41.2 1.62 232.2 9.14 CLEARANCE 6.4 FOR 0.25 MOUNTING HARDWARE 127.1 5.00 1/4 NPTF LO SIDE PROCESS CONNECTION 1/4 NPTF VENT CONNECTION LH & RH
ELECTRICAL CONNECTION 3/4 NPTF STD 1/2 NPTF OPT LH & RH M20 X 1.5 F LH & RH 3/4 PFF RH ONLY
PRODUCT CERTIFICATION DRAWING ALL DIMENSIONS ARE 1/16 IN UNLESS OTHERWISE SPECIFIED MM LINEAR = IN
K MITCHELL
CHECKED BY
M SMITH
ENGINEER APPROVAL
S BOAL
DATE
24 JUN 2011
THIS DRAWING IS THE EXCLUSIVE PROPERTY OF SOR. NO USE WHATSOEVER OF THE INFORMATION CONTAINED HEREON, NOR REPRODUCTION IN WHOLE OR PART MAY BE MADE WITHOUT THE EXPRESS WRITTEN PERMISSION OF SOR.
TITLE
Drawing 0090610
38.1 1.50
0090610 SHEET 1 OF 1
5
DWG SIZE
Reset Form
Drawing 0090611
Housing: TA
sorinc.com 913-888-2630
19/20
Dimensions
Dimensions in this catalog are for reference only. They may be changed without notice. Contact the factory for certied drawings for a particular model number. Dimensions are expressed as millimeters over inches (Linear = mm/in.)
PURCHASE ORDER #
ELECTRICAL CONNECTION 3/4 NPTF STD 1/2 NPTF OPT M20 X 1.5 F OPT FACTORY SEALED LEADS COLOR CODED AND MARKED 457.2 MINIMUM LENGTH 18.00
PROCESS CONN SIZE 1/4 NPTM SHOWN 1/2 NPTF 37.4 1.47 1/2 NPTM 3/4 NPTF 1 ADD
1 215.9 8.50
ISO-9001
7.1 0.28
PRODUCT CERTIFICATION DRAWING ALL DIMENSIONS ARE 1/16 IN UNLESS OTHERWISE SPECIFIED MM LINEAR = IN
K MITCHELL
CHECKED BY
M SMITH
ENGINEER APPROVAL
S BOAL
DATE
14 SEP 2011
THIS DRAWING IS THE EXCLUSIVE PROPERTY OF SOR. NO USE WHATSOEVER OF THE INFORMATION CONTAINED HEREON, NOR REPRODUCTION IN WHOLE OR PART MAY BE MADE WITHOUT THE EXPRESS WRITTEN PERMISSION OF SOR.
TITLE
Drawing 0090612
1/4 NPTF HI SIDE PROCESS CONNECTION 38.1 1.50 1/4 OR 1/2 NPTM PROCESS CONNECTION OPTIONAL 54.7 2.15 84.9 3.34
Housing: BA
0090612 SHEET 1 OF 1
5
DWG SIZE
Reset Form
Drawing 0091067
Housing: AG, AH
Form 468
Registered Quality System to ISO 9001 :2008 14685 West 105th Street, Lenexa, Kansas 66215 913-888-2630 Toll Free 800-676-6794913-888-2630 sorinc.com 20/20
pressure switch should be used when there is a requirement for an adjustable and wide dead band between the increasing and decreasing set points.
Function
V1 Weathertight Housing
3-year warranty from date of manufacture Safety Certied to IEC 61508 (SIL) SOR products are certied to IEC 61508 for non-redundant
use in SIL1 and SIL2 Safety Instrumented Systems for most models. For more details or values applicable to a specic product, see the Safety Integrity Level Quick Guide (Form 1528).
Wide adjustable dead band Independent adjustments for increasing and decreasing Set Points Field adjustable with ne resolution of Set Points Instrument quality high repeatability High overrange and proof pressures Exceptionally long life Not critical to vibration Wide selection of wetted parts materials for process compatibility and containment
Registered Quality Quality System System to to ISO ISO 9001 9001 :2008 Registered :2008
Principle
The SOR Adjustable Dead Band pressure switch incorporates two industry proven Static O Ring pressure sensing elements. Media pressure on the areas of the pistons counteracts the forces of the range springs each adjustable by a separate adjusting nut and moves the piston shafts to operate the lever assembly which, in turn, actuates and deactuates the electrical switching element. Each pressure sensing element of the Adjustable Dead Band pressure switch is a force balance piston-actuated assembly sealed by a exible diaphragm and an o-ring that is static. The only wetted parts are the single pressure port, two diaphragms, and two o-rings all indicated with asterisks (*) in this illustration.
Electrical Switching Element (Explosion Proof Model has Hermetically Sealed Switching Element Capsule)
Screw Terminal Block (Weathertight Model Only) Lever Assembly Calibration Scale Decreasing Set Point Adjusting Nut Piston Assembly Pressure Range Spring *Diaphragm *O-Ring
Calibration Scale Housing Increasing Set Point Adjusting Nut Piston Assembly Pressure Range Spring *Diaphragm *O-Ring *Pressure Port
Principle Schematic
The lever assembly travel illustrated here has been exaggerated for clarity.
Pressure greater than decreasing Set Point but less than increasing Set Point. Electrical switching element remains deactuacted.
Actuation
Deactuation
Pressure equal to or greater than increasing Set Point: Electrical switching element is actuated.
Form 281
Pressure less than increasing Set Point but greater than decreasing Set Point: Electrical switching element remains actuated.
Pressure equal to or less than decreasing Set Point: Electrical switching element is deactuated.
sorinc.com 913-888-2630
2/16
How to Order
5V1-LA3-N6-C1A-YY
Diaphragm
Pressure Port
Accessories
Information and data in this catalog are formatted to provide a convenient guide to assist instrument engineers, plant engineers and end users in selecting pressure switches for their unique applications. Steps 1 through 5 are required. Step 6 is optional. Orders must have complete model numbers, i.e. each component must have a designator. Step 1: Select Adjustable Range from pages 4, 5 and 6 to ll in and . Step 2: Select Housing. Weathertight or explosion proof/weathertight (page 6). Step 3: Select electrical Switching Element for electrical service (page 7). Step 4: Select Diaphragm and O-Ring for process compatibility and containment (page 8). Step 5: Select Pressure Port for process compatibility and connection (page 9). Step 6: Select Accessories required for service (page 9). If Agency Approved, Certied or Listed pressure switches are required, see page 10 for components that must be specied.
How to Order
sorinc.com 913-888-2630
3/16
5V1-LA3-N6-C1A-YY
Six adjustable dead band ranges are available. Each adjustable range is displayed on a grid (pages 5 and 6). Determine the correct adjustable range for the application by checking increasing and decreasing Set Point requirements against the tables. In the example below, a contact closure is required when pressure increases to 160 psi. The same contact must open when pressure decreases to 60 psi. Since 60 psi is within the blue eld, the example grid range is correct for the application. When the correct range grid is selected, insert range designators and from that grid into the model number.
Step 1 Find the specied increasing Set Point at the top of the graph.
Step 2 Find the specied decreasing Set Point along the left edge of the graph.
120
80
40 20 0 1
Step 3 Following the vertical line down from the increasing Set Point. Follow the horizontal line across from the decreasing Set Point. Any point within the blue eld is acceptable. 5
2
5V1-LA3-N6-C1A-YY
1st and 4th places in model number
Form 281
4/16
sorinc.com 913-888-2630
5V1-LA3-N6-C1A-YY
18
Overrange 1500 psi 100 bar Proof 2500 psi 170 bar 60
14
10 80 6 40 2 0 1
40
20 10
160
120
Overrange 2500 psi 170 bar Proof 3875 psi 267 bar
200
80
100 50 0
40 20 0 1
sorinc.com 913-888-2630
5/16
5V1-LA3-N6-C1A-YY
Increasing Set Point (psi)
900 1200 1500 1750 Overrange 2500 psi 170 bar Proof 3875 psi 267 bar
1200
900
400
600
200 100 0 1
45
Step 2: Housing
5V1-LA3-N6-C1A-YY
Service Description
Weathertight for non-hazardous service. NEMA 4, 4X & IP65 Electrical conduit connection: 3/4 NPT(F) Material: 356 aluminum Use LA or SA switching element and terminal block. Shipping weight: 4 pounds (2 kgs) See cutaway view on page 2; dimensions on page 14. Explosion proof and weathertight. NEMA 4, 4X & IP65. Class I, Group A, B, C, D; Class II, Group E, F, G; Division 1 & 2 Electrical conduit connection: 3/4 NPT(F) Material: 356 aluminum Use AG switching element; hermetically sealed SS capsule Shipping weight: 5 pounds (2.5 kgs)
Designator
Non-Hazardous Locations
V1
Hazardous Locations
V3
Form 281
6/16
sorinc.com 913-888-2630
5V1-LA3-N6-C1A-YY
Maximum Ambient Temperature
Contact Form
AC Rating Volts
250
Designator
Amps
15
Amps
.5 1.5 Min. 10.0 Max.
Volts
30
SPDT
125
10
125
180
80
SA
N/A
AC or DC
DPDT
250
11
125
.5*
30
5.0
160
70
N/A
AG
1. The switching elements shown above are UL Listed and CSA Certied. The DC current rating marked (*) is not UL Listed but has been veried by testing and/or experienced. 2. The hermetically sealed switching element capsule is UL Listed, CSA Certied and SAA Approved as a snap switch in accordance with the following table. 3. Consult the factory for availability of SAA Approved units.
Agency UL Listed
Hazardous Location Conditions Class I, Group A, B, C, D; Class II, Group #, F, G; Division 1 & 2
Designator
sorinc.com 913-888-2630
7/16
5V1-LA3-N6-C1A-YY
O-Ring (Wetted) Viton Kalrez Viton Kalrez Viton Kalrez Viton Kalrez Viton GLT Buna-N Viton Neoprene Kalrez Aas EPR Viton Buna-N Buna-N Kalrez Kalrez EPR Aas Buna-N Neoprene Viton Viton GLT Buna-N Viton Neoprene Kalrez EPR Ethylene Propylene EPR Ethylene Propylene Tantalum Kalrez TCP Teon-Coated Polyimide Buna-N Neoprene Viton TCP Teon-Coated Polyimide 316L SS Diaphragm (Wetted) Monel Hastelloy-B Hastelloy-C Carpenter-20 Designator A4 A6 H4 H6 J4 J6 L4 L6 M1 M2 M4 M5 M7 M8 M9 Note 6 N1 N3 Note 4 N4 Standard
Note 1
N5 N6 N7 N8 P1 R1 S1 S2 W2 W4 W5 W6 Y1
6. M9 diaphragm system is suggested for steam applications up to 400oF. 7. Dead bands are slightly higher when using H, J, W, N3, or N6 series diaphragm options. Consult the factory.
Form 281
8/16
sorinc.com 913-888-2630
5V1-LA3-N6-C1A-YY
Designator B1A B2A C1A C2A
Step 6: Accessories
5V1-LA3-N6-C1A-YY
Accessory / Option & Description Designator
Wetted parts are cleaned for industrial oxygen service. CSA Certied pressure switch. Available with V1 housing. Housing has earth (ground) lug. See agency listings on page 10 for details. Cemented cover gasket on weathertight housing. Universal terminal box, 1/2 NPT(F). 316SS. Explosion proof. FM Approved; CSA Certied. See form 657 (Catalog GI-30). Vacuum protector plate retains diaphragm system in the pressure switch if subjected to intermittent vacuum greater than 10 in Hg. If a pressure switch is subjected to continuous, rapid changes of vacuum, other protection may be available (consult factory). Material matches or exceeds pressure port material. Compliance to NACE Certication MR0175/ISO 15156* Pipe (stanchion) mounting kit for (1-1/2 to 2 pipe). Order as a separate line item for CSA Certied pressure switches. Tag, ber. Attached with plastic wire to housing. Stamped with customer-specied tagging information. Powder coat epoxy coating. No coating on stainless steel parts or plated screws. (500 hours-salt spray) Tag, stainless steel. Attached with stainless steel wire to housing. Stamped with customer specied tagging information. (2 lines, 18 characters and spaces per line.) Stainless steel piston and cylinder disc for corrosion resistance. Explosion proof and weathertight electrical junction box with screw terminals. Aluminum 3/4 NPT(F) top or right conduit connections as required. UL Listed and CSA Certied Class I, Groups A, B, C & D; Class II, Group E, F & G; Division 1 & 2. Includes cover o-ring for weathertight applications. (V3 housing only.) Oversize stainless steel nameplate. Permanently attached to housing. Stamped with customer specied tagging information Fungicidal varnish. Covers exterior and interior except working parts. Epoxy coating. Exterior only. Polyimide epoxy with 316SS pigment. (200 hours-salt spray) Chained cover with captive screws to conform to former JIC specication X is used as a sufx to the model number for special requirements not keyed elsewhere in the model number by an X. Each X must be completely identied in the text of the order or inquiry. When more than one X is required, use X followed by the number of such items. For example, X3 means three separate, otherwise unidentiable requirements.
sorinc.com 913-888-2630
BB CS GC HT
MM NC PK PP PY RR SP TB
TT VV YY ZZ X
9/16
Test Certicates
A2
A3
A4
A5
A6
A7
A8
Agency Listings
The following combinations only are available as approved, certied or listed by the agencies shown. Some components are for products not offered in this catalog. Certain components or combinations may acquire additional approval, certication or listing between print dates of this catalog. Contact the factory for the most current information. CSA Enclosure 4 (Weathertight) Piston All Housing V1 Switching Element LA, SA Spring All Diaphragm & O-Ring All Pressure Port Material & Connection Size All Accessories/ Option CS Required All except TB
Form 281
10/16
sorinc.com 913-888-2630
Glossary of Terms
SOR recognizes that there is no industry convention with respect to terminology and denitions pertinent to pressure switches. This glossary applies to SOR Pressure Switches.
Adjustable Range The span of pressure between upper and lower limits within which the pressure switch may be adjusted to actuate/deactuate. Dead Band The difference in pressure between the increasing Set Point and decreasing Set Point. Decreasing Set Point That discrete pressure at which the pressure switch is adjusted to deactuate on falling pressure. It must fall within the adjustable range. Hermetically Sealed A welded steel capsule with glass-to-metal, factory-sealed, electrical leads that isolates the electrical switching element(s) from the environment. Increasing Set Point That discrete pressure at which the pressure switch is adjusted to actuate on rising pressure. It must fall within the adjustable range. Overrange The maximum input pressure that may be continuously applied to the pressure switch without causing permanent change of Set Point, leakage or material failure. Pressure Switch A bi-stable electromechanical device that actuates/deactuates one or more electrical switching element(s) at a predetermined discrete pressure/vacuum (Set Point) upon rising or falling pressure/vacuum.
Proof Pressure The maximum input pressure that may be continuously applied to the pressure switch without causing leakage or catastrophic material failure. Permanent change of Set Point may occur, or the device may be rendered inoperative. Repeatability The ability of a pressure switch to successively operate at a Set Point that is approached from a starting point in the same direction and returns to the starting point over three consecutive cycles to establish a pressure prole. The closeness of the measured Set Point values is normally expressed as a percentage of full scale (maximum adjustable range pressure). SPDT Switching Element Single-Pole, Double Throw (SPDT) has three connections: C Common, NO Normally Open and NC Normally Closed, which allows the switching element to be electrically connected to the circuit in either NO or NC state. DPDT Switching Element DPDT is two synchronized SPDT switching elements which actuate together at increasing Set Point and deactuate together at decreasing Set Point. Discrete SPDT switching elements allow two independent circuits to be switched; i.e., one AC and one DC. The synchronization linkage is factory set, and is not eld adjustable. Synchronization is veried by connecting test lamps to the switching elements and observing them go On simultaneously at actuation and Off simultaneously at deactuation.
sorinc.com 913-888-2630
11/16
Dimensions
Dimensions in this catalog are for reference only. They may be changed without notice. Contact the factory for certied drawings for a particular model number. Dimensions are expressed as millimeters over inches (Linear = mm/in.).
Drawing 0090300
Drawing 0091353
12/16
sorinc.com 913-888-2630
Dimensions
Drawing 0090763
Weights
Actual shipping weights may vary from the charted values because of product material, conguration and packaging requirements.
sorinc.com 913-888-2630
13/16
Housing Dimensions
Dimensions in this catalog are for reference only. They may be changed without notice. Contact the factory for certied drawings for a particular model number. Dimensions are expressed as millimeters over inches (Linear = mm/in.).
Drawing 0090236
Drawing 0090325
Contains Explosion Proof, Hermetically Sealed Switching Element Capsule: UL Listed, CSA Certied, ATEX and SAA Approved
Hazardous Locations
Housing Designator: V3
Form 281
14/16
sorinc.com 913-888-2630
Notes
sorinc.com 913-888-2630
15/16
Pressure
Temperature
Level Switches
Flow Switches
Level
Temperature Switches
Flow
Pressure Switches
Process Instrumentation
SOR - China
Room 903, No. 10 Building Wan Da Plaza No. 93 Jian Guo Road Chao Yang District Beijing, China 100022 Phone +86 (10) 5820 8767 Fax +86 (10) 58 20 8770
16/16
sorinc.com Form 281 (03.12) 2012 SOR Inc. 913-888-2630 Registered Quality System to ISO 9001 :2008
Pressure Switches
General Instructions
These instructions provide information for installation, process and electrical connections and field calibration of SOR Adjustable Dead Band Pressure Switches. The pressure sensing elements are a pair of force-balanced, pistont actuated assemblies sealed by flexible diaphragms and o-rings that are static. The only wetted parts in this arrangement are the single pressure port, two sensing assembly diaphragms and o-rings. Media pressure on the area of the pistons counteracts the force of the range springs (adjustable by the adjusting nuts), which moves the piston shafts only a few thousandths of an inch to operate the lever assembly which actuates and deactuates the electrical switching element.
NOTE: If you suspect that a product is defective, contact the factory or the SOR Representative in your area for a return authorization number (RMA). This product should only be installed by trained and competent personnel.
Installation
Adjustable Dead Band Pressure Switches may be secured to bulkheads, panels or pipe stanchions with suitable bolts. When mounting the pressure switch to an irregular or uneven flat surface, install rubber washers on the mounting bolts between the housing and the mounting surface. Line mounting by either the process connection or the electrical conduit connection is not recommended.
Failure to place washers between the housing and the mounting surface may result in torsional forces on the housing that could cause false trips or render the pressure switch inoperative. Failure to mount the housing on a flat mounting surface may result in torsional forces on the housing that could cause false trips or render the pressure switch inoperative.
Design and specifications are subject to change without notice. For latest revision, go to www.sorinc.com
Form 466 (05.13) SOR Inc. Registered Quality System to ISO 9001
1/4
Process Connection
Securely connect the process line to the pressure port using two wrenches: one to hold the hexagonal flats on the pressure port, the other to tighten the process pipe or tube fitting.
Ensure that the process connection is tightened and positioned so that any binding and torsional forces imposed on the pressure switch are minimal. Do not loosen the pressure port from the body because leakage could result or the pressure switch could be rendered inoperative.
Electrical Connection
Ensure that wiring conforms to all applicable local and national electrical codes and install unit(s) according to relevant national and local safety codes.
V1 Weathertight
Common C1
SPDT: Screw terminal block with marked insulation. Normally Open NO1 Normally Closed NC1
GR - Ground (earth) green wire connected to each hermetically sealed switching element capsule.
Calibration
Remove the housing cover. Connect a suitable variable pressure source with a calibrated reference gauge to the
pressure port. Connect an ohmmeter or test lamp across the switching element contact terminals to monitor contact continuity. Use a 3/4 open-end wrench to turn the adjusting nuts. Slowly increase pressure to the pressure port. The continuity tester will indicate that the contacts have changed state when increasing set point is reached. Note pressure at increasing set point. If increasing set point is too low, turn the left adjusting nut clockwise to raise the increasing set point. If increasing set point is too high, turn the left adjusting nut counterclockwise to lower the increasing set point.
2/4
Form 466 (05.13) SOR Inc.
Slowly decrease pressure to the pressure port. The continuity tester will indicate that
contacts have changed state when decreasing set point is reached. Note pressure at decreasing set point.If the decreasing set point is too low, turn the right adjusting nut clockwise to raise the decreasing set point. If the decreasing set point is too high, turn the right adjusting nut counterclockwise to lower the decreasing set point. The left adjusting nut must always be lower than the right adjusting nut when calibration is complete. Repeat Steps 3 and 4 until desired set points are obtained. If the pressure switch fails to respond to pressure change during calibration, increasing/decreasing set points may be too close together. See Form 281 for minimum/maximum dead band capabilities. Replace the housing cover.
Overtravel has been preset at the factory. The 3/16 overtravel adjustment screw on the lever assembly has been precisely positioned for optimum performance. Any inadvertent movement could render the device inoperative and void the warranty.
Increasing Set Point Adjustment To raise the increasing set point, turn the left adjusting nut clockwise. To lower the increasing set point, turn the left adjusting nut counterclockwise.
Decreasing Set Point Adjustment To raise the decreasing set point, turn the right adjusting nut clockwise. To lower the decreasing set point, turn the right adjusting nut counterclockwise.
The left adjusting nut must always be lower than the right adjusting nut when calibration is complete.
Pressure greater than decreasing set point but less than increasing set point: Electrical switching element remains deactuated.
Pressure equal to or greater than increasing set point: Electrical switching element is actuated.
Pressure less than increasing set point but greater than decreasing set point: Electrical switching element remains actuated.
Pressure equal to or less than decreasing set point: Electrical switching element is deactuated.
3/4
Dimensions
V1 Housing
*Add 6.4 for non-aluminum ports. 0.25
Linear = mm/inches
Drawing 0090236
V3 Housing
*Add 6.4 for non-aluminum ports. 0.25
Linear = mm/inches
Drawing 0090325
Dimensions are for reference only. Contact the factory for certified drawings for a particular model number.
Printed in USA
www.sorinc.com
14685 West 105th Street, Lenexa, KS 66215 913-888-2630 800-676-6794 USA Fax 913-888-0767 4/4
Registered Quality System to ISO 9001 Form 466 (05.13) SOR Inc.
Series 101/121
Mini-Hermet Models
B-Series Models
General
These instructions provide information for installation, electrical connection, process connection and calibration of Series 101/121 Differential Pressure Switches. B-Series models (B3, B4, B5, B6) may be ATEX Approved with the addition of a CL option at the end of the model string. Specic information and instructions concerning these models will be found throughout the following pages. NOTE: SOR discourages eld modications and eld repair. Products should be returned to SOR for inspection and necessary repair work. Contact the factory for a return authorization number. Any eld work should be performed by qualied instrument technicians using factory-authorized procedures. Principle of Operation Process pressure is sensed by a diaphragm and piston assembly. The piston responds to differential pressure and moves a shaft that actuates (deactuates) an electrical switching element. Low side pressure and an adjustable range spring oppose high side pressure. Adjustment of the range spring determines the set point. (See Calibration.) CAUTION: Use care during installation to avoid moving the electrical switching element or its housing. Movement of either could change calibration or render the device inoperative. Design and specications are subject to change without notice.
Process Connection
Connect the process lines to the pressure ports using two wrenches: one to hold the hex ats on the pressure port, the other to tighten the process pipe or tube tting. The high pressure side (stamped HI) and the low pressure side (stamped LO) have 1/4 NPT(F) or 1/4 BSP(F) process connections as standard. IMPORTANT: Rigid process piping must be arranged to minimize bending or twisting forces which could disturb the positioning of internal parts and change calibration or render the device inoperative after installation. Use care to avoid loosening the pressure port from the body or the body from the electrical housing.
Installation
This product should only be installed by trained and competent personnel. 1. Secure the housing to a bulkhead, panel rack or pipe stanchion with suitable bolts. IMPORTANT: When bolting housings with integral mounting pads to irregular or uneven surfaces, install rubber washers between the housing and the mounting surface to prevent deformation of the housing.
For latest revision, see www.sorinc.com SOR Form 506 (04.05) Printed in USA
Electrical Connection
Ensure that wiring conforms to all applicable local and national electrical codes and install unit(s) according to relevant national and local safety codes. NOTE: For B-Series ATEX Certied Models Electrical conduit connection threads may be of non-ISO thread form. Check the product nametag for relevant thread form information before attempting to connect to the electrical conduit connection. In the event a tting is used, check the adaptor body for thread size information.
Page 1 of 4
CAUTION: Electrical power must be disconnected from explosion proof models before the cover is removed. Failure to do so could result in severe personal injury or substantial property damage. When making electrical connections, use care to avoid movement of the electrical switching element. Electrical connections are either screw terminals, terminal blocks or 18-gauge, 18-inch wire leads. Screw terminal and terminal block points are identied on the insulation card inside the electrical housing. Refer to the wiring schematic in Figure 1 for wire lead color codes.
on the interior wall of the housing. If coarse or precise set point calibration is required, calibrate according to the appropriate procedure. WARNING: For B-Series Housings The electrical compartment cover must remain sealed and the Allen locking screw tightened at all times to prevent removal of the cover while the pressure switch is in service. Removal of the cover while the pressure switch is in service in a hazardous location could result in severe personal injury or substantial property damage. Coarse Calibration Procedure 1. Connect variable pressure source to test gauge and HI side pressure port. 2. Connect test light or ohmmeter across C Common and NO Normally Open switching element contacts. 3. Raise pressure and note test gauge reading when circuit closes. 4. Slowly drop pressure and note test gauge reading when circuit opens. 5. Turn set point adjustment clockwise to increase set point, or counterclockwise to decrease set point. 6. Repeat Steps 3, 4 and 5 until contacts change at desired increasing or decreasing differential pressure set point. Precise Calibration Procedure The precise calibration procedure references system (static) pressure. Set point accuracy is enhanced by calibrating the differential pressure switch under simulated service pressure conditions. The following test apparatus is recommended. 1. 2. 3. 4. Differential pressure gauge Variable pressure source Block/bleed and equalizer valves Test light or ohmmeter
HI
Differential Pressure
DPDT (2-SPDT)
LO
Blue (C) Black (NO) Red (NC) Yellow (C2) Brown (NO2) Orange (NC2)
No. 1
HI
No. 2
Differential Pressure
FIGURE 1
NOTE: Storing excess wire or making wire lead splices inside the pressure switch housing should not be done and may interfere with the pressure switch operation.
Determine whether the critical set point occurs on increasing or decreasing differential pressure, and calibrate using the appropriate procedure: For Critical Set Point on Increasing Differential Pressure 1. Connect the continuity test lamp or ohmmeter across the C - Common and NO - Normally Open switching element / contacts. 2. Close the bleed valve(s), open the equalizer valve and raise pressure equally on both HI and LO sides to the static pressure that the differential pressure switch will see under normal operating conditions. 3. With static pressure stable, close the equalizer valve to isolate the HI side from the LO side. 4. Keeping high side pressure steady, slightly open the LO side bleed valve to reduce the LO side pressure (increase differential pressure) until desired differential pressure set point appears on indicator. Close bleed valve to stabilize differential pressure. Check the status of the electrical contacts against the following differential pressure trend graphs. Follow the instructions under the graph that matches the status of the contacts. See SOR Form 468 for reference dimension drawings. For certied dimension drawings contact factory.
Calibration
Mini-Hermet models Remove the weathertight cap. Use a 1/8 hex Allen wrench to turn the adjusting screw to the desired set point. Turn the adjusting screw clockwise (in) to increase the set point and counterclockwise (out) to decrease the set point. Use either the coarse or the precise set point calibration procedure. CAUTION: Do not unthread the adjusting screw more than two threads below the ush point of housing as calibration could be adversely affected. All Other Models Use a 3/4-inch open-end wrench to turn hex adjusting nut clockwise to increase set point, and counterclockwise to decrease set point. An approximate set point can be obtained by sighting across top of adjusting nut to the calibration scale
Page 2 of 4
Set Point OK
Make
Differential Pressure
Make
Break
0 Time
0 Time
0 Time
If contacts make precisely at critical increasing differential pressure set point, repeat Steps 2 - 4 as desired to verify calibration. Calibration is complete.
If contacts are open when critical increasing differential pressure is reached, turn set point adjustment counterclockwise (out) until contacts make. Repeat Steps 2-4.
If contacts are closed when critical increasing differential pressure is reached, turn set point adjustment clockwise (in) until contacts break. From this point, turn set point adjustment counterclockwise (out) until contacts make. Repeat Steps 2-4.
Set Point OK
Normal Operating Differential Pressure Differential Pressure Make Critical Decreasing Set Point 0 Time 0 Time
Make
0 Time
If contacts break precisely at critical decreasing differential pressure set point, repeat steps 2-5 as desired to verify calibration. Calibration is complete.
If contacts are open when critical decreasing differential pressure is reached, turn set point adjustment counterclockwise (out) until contacts make. From this point, turn set point adjustment clockwise (in) until contacts break. Repeat Steps 2-5.
If contacts are closed when critical increasing differential pressure is reached, turn set point adjustment clockwise (in) until contacts break. Repeat Steps 2-5.
Page 3 of 4
Operation
For B-Series ATEX Certied Models
Maximum Surface Temperature T6 Rating - 85oC T5 Rating - 100oC
Adjustable Range psid 3 to 30 10 to 75 75 to 500 bar .2 to 2.1 .7 to 5.2 5.2 to 34 AC Rating Volts 250 125 125 250 250 250 250 250 125 250 250 250 250 250 250 125 125 Amps 15 1 1 15 11 15 5 15 10 5 5 5 15 15 5 1 1
45 45
DC Rating Resistive Volts 125 125 125 125 125 125 125 125 125 125 125 Amps 0.4 0.5 0.5 0.5 0.5
1.5 Minimum 10.0 Maximum
Volts 30 28 30 30 30 30 30 28 30
Amps 5 1 1 5 10 5 5 1 1
913-888-2630
Fax 913-888-0767
www.sorinc.com