Sei sulla pagina 1di 2

Symmetrix VMAX Series: Error code: 3C3E occurring on SAF

Article Number:000090553 Version:3


Key Information Original Create Date: Tue Jan 22 16:27:05 GMT 2013 First Published: Wed May 29 Channels: Customer , Internal App 20:38:06 GMT 2013 Originally Created By: Paul Last Modified: Fri Aug 09 Dwyer 21:00:09 GMT 2013 Summary: Article Content Issue: Error code: 3C3E occurring on SAF. Error code: 3C3C occurring on SAF. Error code: 2812 occurring on SAF. Error code: DEDA occurring on DAF. Error code: DA02 occurring on DAF. Error code: 282C Environment: Product: Symmetrix VMAX Series Enginuity: 5876 Device Emulation: FBA Configuration: Thin Device Configuration: Meta Volume No gatekeepers on the SAF ports. Gatekeepers are configured but are masked off the SAF ports. Cause: The 3C3E or 3C3C results from a call in the code to set "free_scratch_slot_p_dv_specify_return_no_indirect_TID_read" in the options flags. When this is a Thin device, during the scratch slot unlock, the code ends up re-reading the I table of the first track from the source device. This then results in the code overwriting the current WP sector signatures in the device record, and when the code calls "move_safe_write_context" out of the meta switch, this old value from global memory is what is copied over as the expected "new" sector signature. This scratch slow options flags command does not exist in Enginuity 5875. Resolution: Field Service: Audience: Level 40 = Employees and Partners Article Type: Break Fix Validation Status: Final Approved Last Published: Fri Aug 09 21:00:09 GMT 2013

An OPT has been opened with Engineering and a permanent fix is in progress. Contact the Support Center for escalation to a Recovery Team Data Structures SME and quote this solution ID. For 5876: Fix 66424 is released GA at 5876.229.145 and also available in an Enginuity Pack for 5876.159.102 .

Notes Support Center: (Restricted): OPT: 413847 Fix: Escalate any DEDA, DA02, or 282C to a Recovery Team Data Structures SME. An OPT has been opened with Engineering and a permanent fix is in progress. For 5876: Fix 66424 is released GA at 5876.229.145 and also available in an Enginuity Pack for 5876.159.102 . Workaround: Have the Gatekeeper devices added or have the customer unmask them.

Article Metadata Product: Symmetrix VMAX 10K (Systems with SN xxx987xxxx), Symmetrix VMAX 40K, Symmetrix VMAX Cloud Edition, Symmetrix VMAX Series, Symmetrix VMAX/VMAX 20K, Symmetrix Enginuity 5876 Firmware: Enginuity 5876 Hardware Platform: Symmetrix VMAX Series Problem Code: Code Bug;EMC Firmware Shared: Yes RCA Status: In Process-Engineering Bug Tracking Number: 413847 External Source: Primus Primus/Webtop solution ID: emc314595 Originally Created By: Paul Dwyer

Potrebbero piacerti anche