An Amateur X-Ray System

Neon tester and Geiger counter. Demo-type cathode-ray tube and vacuum flask. Film, film safe, cassette, chems., trays & thermom. High-voltage system using auto ignition parts. Simple system with one coil and one ignition box. Timer schematic. Twin ignition coil hookup. Stun gun parts in box. The first X-ray. The fourth X-ray. The ninth X-ray, using only one coil. X-rays have fascinated me ever since I first put my foot into a Pedoscope in a shoe store in the '40s. There were the bones of your toes wiggling around inside your shoe. A friend would put his hand in the opening so you could see his hand bones and then you'd do that for him to see your hand. This project is a high-voltage system that is made from common auto and electronic parts suitable for making X-rays for hobby applications. It was fortuitous that Roentgen discovered X-rays at all. By chance, he had the absolute minimum equipment necessary to create and detect them, and all his equipment was state-of-the-art at that time. The power supply was a new and very costly induction coil producing 35,000 volts at 8 pulses per second. His X-ray source was a Crooke's gas-discharge tube with a verylowfor-the-time vacuum of 1/10,000 atmospheres. His viewing screen was a barium platino-cyanide powder which he was using to see the mysterious radiation coming from gas-discharge tubes and radioactive salts. Many college physics departments were using similar equipment at the same time. In fact, Crooke missed discovering X-rays first only because he had wrongly assumed that his photo plates, which were stored near his equipment while it was working, were fogged accidentally at the factory before he received them! The first good human body-part X-ray, of Roentgen's wife's hand, required a 15-minute exposure. Roentgen received the very first Nobel prize for his discovery. He also never patented the X-ray system, knowing it was much too important to waste time going thru the lengthy patenting process. Within three years, every major medical institution in the world was using Xrays. They were even used at the front during the War of the Sudan. Early experimenters used twin X-ray exposures to produce the only true stereo-

scopic (3-D pair) images of fractures ever made, predating 2-D-only CAT scans by seven decades! Early amateurs discovered that a Wimshurst machine produces the proper voltage with adequate current at an affordable price. Periodicals aimed at the "handy electrician" showed how to determine the polarity of the sparks from these machines and how to identify a Crooke's tube which would produce X-rays well. Photographic equipment and film was common at the time. Newsletters gave how-to information, X-ray exposure times, best films to use and advertised new, specialized X-ray equipment. Soon companies that made Crooke's and other gas-discharge tubes started making dedicated X-ray tubes. We began by looking around for a way to make about 75,000 volts with 1 to 6 mA of current using available parts. Using marble-size metal balls to get a true measure of voltage by the length of a spark, we found that a stun gun makes 40,000 V at .3 mA, despite advertising claims. But these cannot be left on for any length of time. A neon tester probe gives 45,000 V at an unknown current, but probably in the range of .1 mA. A neon sign transformer produces 15,000 V at 30 mA, but the arc can be drawn to over an inch while travelling up a Jacob's Ladder. This translates to 50,000 V and the current would drop. There is a solid-state induction coil sold by school science suppliers that claims to produce 65,000 V at .5 mA. The Pedoscope produced 50,000 V at 3 to 8 mA and released from .5 to 6.0 Roentgens/second. Dental X-ray machines produce 75,000 V at up to 15 mA during their brief exposures on the small films used. Our Geiger counter, used to show radioactivity from mineral samples and cosmic (gamma) rays, measures up to .01 Roentgens/hr., not Roentgens/sec. So to test your X-ray equipment output with one, you need to be some distance away and extrapolate back to the source output. Or use roofer's lead sheeting as an attenuator and compare your system's output to a dentist's or vet's X-ray unit output. An induction coil is a transformer with the primary switched by a set of contact points, like on an older car's ignition, to put a sharply rising voltage into the primary. The sharper the rise rate, the higher the induced voltage out. A stun gun, US patent #4,253,132, is an Oudin coil. It uses about 400 volts from a smaller transformer switched by a spark discharge from a capacitor that is then sent into a voltage multiplier and capactor. A neon tester is a combination of a small induction coil and a high-voltage autotransformer. (The standard probe on it has a spark gap inside the white plastic girdle and should be defeated by using a solid wire probe

instead.) We decided to use common car ignition coils for the high-voltage source. Two coils can be hooked together in anti-parallel to produce 3", hot, loud sparks. A scary sight to all those who are not used to crazy experiments! The film was placed between fluorescent "screens" in a "cassette" to reduce the X-ray exposure time needed down 1/20th to 1/150th of that required when using film alone. Our cassette is a Kiran blue-sensitive "HiPlus". Fuji RX-B 5" x 7" X-ray film was used. (8" x 10" X-ray film is more common.) Processing was with common Kodak black-and-white photo chemistry. The car coils can be switched by a relay driven by a simple 555 timer circuit and a MOSFET. The relay points need a capacitor across them to reduce arcing so that the switching will be as abrupt as possible. (The points will still get rough and need polishing frequently.) Use a .7 to .9 mF, 200 V cap across the relay contacts. A ballast resistor of .8 ohms is used in series with MSD 8223 coils. We used a garage battery charger for the power with a total of 20,000 mF, 35 V caps for ripple filters. But you could use a car battery instead of a garage charger and all those capacitors. Twin aftermarket ignition systems can be employed to drive the coils. We used twin MSD 5900s in parallel. When using the 5900s, no ballast resistor is needed for the coils. This gave us 90,000 V at an undetermined current, but the loud, snapping sparks indicated that it was adequate. A homemade X-ray tube can be made using a shortened aurora tube if a high enough vaccuum can be pulled. A tube like this and a cathode ray tube are "cold-cathode" tubes, having no glowing filament to kick out a shower of electrons, and do not produce X-rays as well as "hot-cathode" type tubes. It should be stated that when ignition coils are not connected to spark plugs, the voltage rises unchecked to a maximum and can damage the coil. After a while one MSD Blaster 3 coil arced thru the center tower to the brass ground terminal, carbonizing the plastic and ruining the coil. So the good coil was immersed in mineral (baby) oil with just the tip 1" above the oil. This stopped any wasteful corona and carbonizing. Remove both nuts, solder wires to the top of the brass terminals and then lower the coil into a glass that is about 2 & 1/2" wide inside and about 6 & 1/2" deep. Acetone dissolves spilled oil. The MSD Blaster 3 (8223) coils were much better than other MSD coils and better than two types of Accel coils. The spark between the coil tips is brighter at the positive tip. This tip should go to the X-ray tube anode. But the system is not pure DC, and the X-ray tube itself acts like a vacuum-tube diode and rectifies the AC. An old RAD-1 tube used with twin auto coils in open air and 6 volts going

to the filament took a 10 minute exposure to give us our first X-ray. The image shows a tungsten strip at the top, a molybdenum ore-assay boat next, then a tungsten wafer, then a lead strip and finally a wood block with a steel nail, a steel brad and a brass brad in it. There are two holes drilled in the wood block. Other X-rays we did show that X-ray exposure time and development time are critical to imaging what it is you wish to examine inside the items X-rayed. Our fourth X-ray shows a skyrocket, tape measure, lighter and can opener. But a shorter exposure time showed the skyrocket motor's internal structure better. (See the Homemade Fireworks page.) The neon tester connected to the cathode-ray tube (a cold-cathode tube) with one side grounded to a water pipe required 15 minutes to produce a very dim second and third X-ray. A skyrocket, a small Crescent wrench and a cigarette lighter were placed on the film cassette. But only the outline of the adjustable wrench is obvious. The neon tester used with the old RAD-1 tube with filament current going to it and with the anode grounded to a water pipe produced a light but quite useable X-ray in 6 minutes. Using only one 8223 coil immersed in mineral oil, the twin 5900s and with the RAD-1 filament on produced a good X-ray in 3 min. The ignition coil tip goes to the RAD-1 cathode and the anode was grounded to the battery charger negative clamp. The X-ray shows a computer mouse, a pen and a photoelectric night light. The pulse timing was 40/sec. An exposure of only 20 seconds yielded a good X-ray of the rocket motor interior. Using one 8223 coil in oil and the NAPA AR-108 relay with .9 mF across the points produced a good X-ray after 10 minutes. That was with the RAD-1 filament on and using fresh D-cells. The .8 ohm ballast resistor must be used when not using the ignition boxes. The relay points took a beating after just one X-ray and needed to be filed and sanded smooth again. When using one 5900, the MOSFET signal can go directly to the RPM sensor inputs, violet to the MOSFET drain and green to the +9 volt bus. Of course, with this hookup, the frequency can be set higher than 40 pulses/sec. The best system at reasonable cost consists of a dental X-ray tube (Toshiba D-088 or D-101, for instance), one Blaster 3 coil, one 5900 ignition box and no relay on the timer/pulser board. The white wire, which is only for older cars which have contact points, is not used. NOTES: X-ray film scratches easily when in the solutions, so use care. Touch them only around the edges when wet. (OK to touch when dry) All X-rays were taken by plugging in a long extension cord in another room to power up the battery charger and start the exposure. The 9-volt pulser battery and the 6-volt D-cell filament

batteries were connected manually before leaving the exposure room. PARTS: MSD Blaster 3 coil #8223 MSD Blaster Ignition #5900 Relay: NAPA AR-108 (if used instead of the 5900) MOSFET: Radio Shack 276-2072 (IRF 510) Caps for filtering: Radio Shack 272-1022 (4) See eBay for used X-ray tubes, also called "inserts". (mike@amerytel.net) Geiger counter: Frey 15598209 (optional) Neon tester: Frey 15583518 (optional) Induction coil: Frey 15583515 (optional) replaces timer/pulser, coil & 5900 Kiran Hi-Plus cassette, blue-sensitive (or equivalent) 5 x 7 or 8 x 10 Fuji RX-B film (or equivalent) 5 x 7 or 8 x 10 Kodak Hobby-Pac, 3 trays and safelight (optional: thermometer, paper safe) PHOTO NOTES: Mix one pint of solutions at a time. In safelight illumination, open film box and take out one sheet of film at a time from black plastic bag. (end sheets are cardboard) Seal rest of film back in box. Put film in cassette and close securely. Light can now be turned on. After each X-ray exposure, turn safelight on and light out. Remove exposed film and place in the paper safe. (Or an old film bag.) Repeat for the next X-ray. When ready to process film, pour solutions in trays. Turn light out and safelight on. Use one hand to slip film into and out of developer one at a time for the required time. Use the other hand for stop bath and fixer. Keep a paper towel handy to wipe the solutions off your hands frequently. NEVER splash stop bath or fixer hand in developer! After sliding films into solution so they are submerged, agitate the tray gently by rocking. Times are 5 min. in developer, 10 sec. in stop bath, 2 to 5 min. in fixer and 30 minutes washing in running water. Lights can be turned on when films are in fixer. Stand films on edge on paper towel angled with one side touching a back rest to dry the films.

Neon tester and geiger counter

Demo type cathode - ray tube and vacuum flask

Film, film safe, cassette, chems., trays & thermom.

High-voltage system using auto ignition parts.

Simple system with one coil and one ignition box.

Timer schematic.

Twin ignition coil hookup.

Stun gun parts in box.

The first X-ray.

The fourth X-ray.

The ninth X-ray, using only one coil.