Lifting stations
Lift wastewater
Ecolift uses the natural gradient to the sewer and only uses the pressure pipe through the backwater level for discharge during backwater events.
Ecolift backwater lifting station ........... 38 for underground installation Ecolift backwater lifting station ........... 38 for installation in an exposed wastewater pipe
Backwater level
Lifting station Aqualift F Compact .... 42 - 45 for installation in a concrete slab/floor and free-standing installation Lifting stations for interior installation
Lifting station Aqualift F Mono / Duo ....... 46 for free-standing installation Lifting station Aqualift S Mono / Tronic / Duo ................. 48 for installation in a concrete slab/floor
Backwater level
Twin lifting station Aqualift S .................. 50 for free-standing installation Lifting station Minilift .............................. 50 for installation in a concrete slab/floor and free-standing installation Lifting station Aqualift F Duo XXL ........... 52 for free-standing installation Lifting station Aqualift F .......................... 56 in Komfort inspection chamber system 1000
Pumping station Aqualift F ....................... 58 in inspection chamber system 600 Pumping station Aqualift F ....................... 59 in Komfort inspection chamber system 800/1000 Pumping station Aqualift F ....................... 60 in Komfort inspection chamber system 1000 Pumping station Aqualift S ....................... 62 in Komfort inspection chamber system 600 Pumping station Aqualift S ....................... 63 in Komfort inspection chamber system 1000
Backwater level
Submersible pump KTP 1000 .................. 66 for wastewater without sewage Submersible pumps
Submersible pump KTP 500 .................... 66 for wastewater without sewage Submersible pump KTP 300 .................... 67 for wastewater without sewage
34
Catalogue 2.3
Catalogue 2.3
35
Submersible pumps
- Professional advantages
Until now:
In the future:
Ecolift where there is a natural gradient to the sewer Advantages during flooding / backwater:
Cellar draining via the integrated drainage function In the event of additional backwater, wastewater disposal is via the backwater loop The backwater valve and additional pressure pipe provide protection from backwater
1.
Submersible pumps
Normal mode:
Backwater level
2.
Backwater:
Backwater level Backwater level
36
Catalogue 2.3
9 mm
Fast and straightforward servicing Installation in waterproof concrete Gasket set to prevent groundwater infiltration (accessory).
Idealfor
Performance diagram Ecolift Covers can be individually tiled No open pump sump or maintenance space required per EN 12056, Part 4 - means more living space.
[m] 9 8 7 6 5 4 3 2 1 2 4 6 10 [Qm3/h] 8 Pumping capacity Q (m3/h)
Pumping height m
24-h
On-call service thanks to comprehensive customer services with 24 h emergency service within Germany and large parts of Europe.
Catalogue 2.3
37
Submersible pumps
Fully open pipe passage with open backwater flap during normal conditions, flap is automatically closed with motor during backwater
Integrated drain function for drainage of surface water Continual drainage even in the event of a catastrophe
Pump head outside the flow area Offers full channel passage Increased pump volume
Removable inlet/outlet connections also in 200 Socket/spigot for customized connections, variable inlet and outlet sizes available.
New Komfort version with digital display which shows operating status and servicing instructions as well as connection option for building management system.
Ecolift backwater lifting station for wastewater with or without sewage for underground installation
Illustration and dimensioned drawing Article description * Article #
With recessed cover for on-site tiling and drain (X) for pipes with natural gradient to the sewer 21 100X 110 The alternative to a standard lifting station 21 125X 125 For wastewater with or without sewage, for installation in a concrete slab/floor. 160 21 150X Installation depth (D) 486 mm to 640 mm 200 21 200X Including installation set and cover plate with integraWith black cover and drain (S) ted drain function for surface water drainage. With 21 100S 110 integrated pump and motorized backwater flap. During normal conditions, the pipe cross section is open, in 21 125S 125 the case of backwater the valve is closed and locked 21 150S 160 completely automatically. During the backwater period, soiled water is drained using a pump with macerating 21 200S 200 (cutting) device, via a pressure pipe 40 mm over the backwater level. Plug-in control and warning unit with display, self-diagnosis system (SDS) and battery buffering for maximum safety, with logbook (diary function) for reading the past operating conditions.
40
125
Power cable / cable length: 5 m Mains voltage/frequency: 230 V AC / 50 Hz Protective rating: IP 54 (switch unit) Protective rating: IP 68 (motor) 110 125 160 200 L: L: L: L: 642 645 656 720 mm mm mm mm H: H: H: H: 394 387 370 348 mm mm mm mm
Certification: Z-53.2-487
Ecolift backwater lifting station for wastewater with or without sewage for installation in an exposed wastewater pipe
Illustration and dimensioned drawing Lifting stations for exterior installation Article description * 110 125 160 200 Article # 21 100 21 125 21 150 21 200
40
Submersible pumps
L: L: L: L:
mm mm mm mm
H: H: H: H:
mm mm mm mm
Certification: Z-53.2-487
* = Outer Diameter
38 Catalogue 2.3
Accessories
Illustration and dimensioned drawing Article description * Article # 83 023
Gasket set
Ideal for installation in waterproof concrete waterp for consisting of: concreroof te Counter flange made of polymer, incl. screws, elastomer waterproof membrane in NK/SBR 800 mm
for article numbers: 21 100 X/S, 21 125 X/S, 21 150 X/S, 21 200 X/S
83 071
414
Extension section
made of polymer, max. extension 180 mm, incl. gasket for article numbers: 21 100 X/S, 21 125 X/S, 21 150 X/S, 21 200 X/S When multiple extension section are used make sure that access to valve is still possible !
83 070
414
40
28 040
Potential-free contact
Change-over contact 42 V / 0.5 A; Additional circuit board with a potential-free contact e.g. for connecting control unit to BMS (Building Management System).
80 072
Electronic audible alarm (continuous tone) with connection cable 20 m Minimum current consumption 5 - 25 mA, audible tone 4.7 KHz - 90 dB, large voltage range 6 - 24 V DC; Dimension 31 x 15 mm.
384 42
83 045
107
384
42
83 046
105 37
Multistop
odour, foam, rodent and insect stop for article numbers: 83 045 and 83 046
43 500
109 14
Hair filter
made of polymer for article numbers: 83 045 and 83 046
Catalogue 2.3
43 700
39
Submersible pumps
107
Audible alarm
20 162
made of polymer, max. extension 180 mm, incl. gasket For gasket set Art. # 83 023 for article numbers: 21 100 X/S, 21 125 X/S, 21 150 X/S, 21 200 X/S When multiple extension section are used make sure that access to valve is still possible !
10
40
180
230
Accessories
Illustration and dimensioned drawing
450 400
Article description
* -
Article # 83 061
Upper section
Size 220, made of polymer, max. extension 180 mm, height adjustable for article numbers: 21 100 X/S, 21 125 X/S, 21 150 X/S, 21 200 X/S
222 22
414
Inlet / Outlet
Spigot 110 125 160 200 110 125 160 200 83 081 83 082 83 083 83 084 83 085 83 086 83 087 83 088 28 351 80 891
80 076 80 890
Optical probe
Includes adaptor set 80892, cable length: 5 m
80 888
80 889
Adaptor set
80 892
Submersible pumps
40
Catalogue 2.3
Catalogue 2.3
Ideal
for
waterproof concrete
41
Submersible pumps
70 - 180
590 400
110
420
122
207
80
295 351
40
70 - 180
590 400
Submersible pumps
110
420
122
207
80
295 351
40
Installation suggestion
Ideal
waterproof concrete
Lifting station Aqualift F Compact Art. # 28 701 Control unit (potential-free contact Art. # 80 072 otional)
Gasket set Art. # 83 023 Extension section with flange Art. # 83 071
Pumping height m
Current type Voltage Current Motor rating P1/P2 RPM Motor protection
Alternating current 230 V 4.9 A 1080 W / 620 W 2800 min-1 integrated S3 - 30%
8
3
10 [Qm3/h]
Operating mode
KESSEL - Professional advantages Three functions... Lifting station for wastewater with or without sewage Integrated floor drain, drains any water from basement floor Chamber ready to be installed, can even be installed in waterproof concrete Suitable for installation in a concrete slab/floor. The telescopic upper section allows flexible adjustments to suit the required installation depth.
Ideal
waterproof concrete
for
Elegant optical appearance even for cellar rooms which are used as living accommodation: The up-to-date alternative to the pump chamber.
Application Can be used as a lifting station according to DIN 12056-4 for wastewater with sewage to drain outlet points below the backwater level in private households.
43
Catalogue 2.3
Submersible pumps
[m] 9 8 7 6 5 4 3 2 1
Type
TPF 1000
for
110
207
80 580 670
351 395
40
110
207
Submersible pumps
80 580 670
351 395
40
Installation suggestion
Lifting station Aqualift F Compact Art. # 28 743 Control unit (potential-free contact Art. # 80 072 otional)
8
3
10 [Qm3/h]
Operating mode
KESSEL - Professional advantages Tool free pump removal The backwater flap prevents the wastewater from backing up into the system. Maximum safety thanks to control unit with SDS The intelligent control unit with integrated self-diagnosis system SDS and battery buffering continually monitors all electric functions and keeps an electronic operating log which can be read out. If the pump is at a standstill for longer periods, it is automatically activated briefly once a week. Sound absorption underlay mat for sound reduction
Ideal for renovation Thanks to its installation area of only 700 x 700 mm, the Aqualift F Compact can also be used in an existing 1000 mm pump sump. An acoustic insulation mat is included in the scope of supply. The free-standing model is delivered ready for connection.
Catalogue 2.3
45
Submersible pumps
[m] 9 8 7 6 5 4 3 2 1
Pumping height m
Lifting station Aqualift F for wastewater with or without sewage with/without closure valve for free-standing installation according to EN 12056
Illustration and dimensioned drawing Article description Power
1
Current connection
Article #
Without closure valve with vertical pressure outlet: 28 751 1.1 kW 400 V 28 752 2.2 kW 400 V With closure valve with horizontal pressure outlet: 28 753 1.1 kW 400 V 28 754 2.2 kW 400 V
2
664 466
110
75
32
Without closure valve with vertical pressure outlet: 1.1 kW 230 V 28 646
With closure valve with horizontal pressure outlet: 1.1 kW 230 V 28 648
Lifting station Aqualift F Duo for wastewater with or without sewage with or without closure valve for free-standing installation according to EN 12056
Illustration and dimensioned drawing Article description Power Current connection Article #
Without closure valve with vertical pressure outlet: 28 764 1.1 kW 400 V 28 765 2.2 kW 400 V With closure valve with horizontal pressure outlet: 28 766 1.1 kW 400 V 28 767 2.2 kW 400 V
788 590
32
75 110
Submersible pumps
780 773
46
160
KESSEL Professional advantages Quality and reliability are our strengths: Reliable function and fully automated operation High capacity and compact pumps Simple to install or mount in a small space
50 15 52 54 17,5 56 58 20
Pumping height m
400 V 2.2 kW
8 2,5
12
16 5
20
24
28 7,5
32
36 10
40
44 12,5
46
48
Pumping capacity Q (l /s) Type Power (P2) Intake Power (P1) Voltage Frequency Amperage Fuses Cable connections Media temperature Weight (Pump) Protection Operating mode U / min FPF 220 - 400 V FPF 110 - 230 V FPF 110 - 400 V 2.2 kW 1.1 kW 1.1 kW 3.2 kW 1.6 kW 1.4 kW 400 V DC 230 V AC 400 V DC 50 Hz 50 Hz 50 Hz 5.4 A 7.3 A 2.7 A 3 x 16 A surge-proof 16 A surge-proof 3 x 16 A surge-proof 10 m Length, 7 x 1.5 mm2 10 m Length, 7 x 1.5 mm2 10 m Length, 7 x 1.5 mm2 40C 40C 40C 23 kg 24 kg 24 kg IP 68 IP 68 IP 68 S3 S3 S3 60% power on duration 60% power on duration 30% power on duration 1.370 1.415 2.845
400 Volt Komfort control unit User friendly navigation in multi-line display With self-diagnosis system SDS and memory function for the next service Displays the current measured values Simple setting of the parameters relevant for the function Operating hours counter Optional forwarding of alarm and general fault signals via a GSM interface Multilingual display (EN, DE, FR, IT, PL, NL)
Accessories
Closure valve
for article numbers: 28 646, 28 751, 28 752, 28 764 and 28 765 as retrofit kit Art. # 28 683 Art. # 28 698
110
32 75 110
Sound absorption
sound-absorbing underlay mat (10 mm thick) 560 x 510 mm (Single-station) 820 x 710 mm (Duo-station) 50 75 110 125 160 28 692 28 693 Submersible pumps 850 114 850 116 850 117 850 118 850 119 50 100
Hole saw
for drilling lateral surfaces for inlets and outlets 50, 75, 110, 125 and 160 (Saw blade holder = 190 mm)
Catalogue 2.3
Lifting station Aqualift F for wastewater with or without sewage with/without closure valve for free-standing installation according to EN 12056
Lifting station Aqualift S for sewage free wastewater For installation in a concrete slab/floor, according to EN 12056
Illustration and dimensioned drawing Article description 40 Article # 28 500
27 - 202
40
D P
Type-tested
and monitored
with teed guaran quality tested
EN 12050 - 2
Optional: Multistop odour, foam, rodent and insect stop, page 39 Hair filter page 39
Lifting station Aqualift S Tronic / Aqualift S Duo for sewage free wastewater For installation in a concrete slab/floor, according to EN 12056
Illustration and dimensioned drawing Article description Article #
27 - 202
400
D 454 330
590
258
40
40
28 550
40
28 530
Art. # 28 550
27 - 202 P D
Submersible pumps
Art. # 28 530
LGA
Type-tested
and monitored
with teed guaran quality tested
EN 12050 - 2
Catalogue 2.3
Optional: Audible alarm page 51 Potential-free contact page 51 Multistop odour, foam, rodent and insect stop, page 39 Hair filter page 39
KESSEL Professional advantages Three functions... Lifting station for wastewater without sewage Discharge, even with a fractured pipe or incoming flood water Chamber ready to be installed, can even be installed in waterproof concrete
Pumping height m
2,0
40
Accessories
Pressure pipe set
Incl. 5 m pressure pipe hose 40, Adaptor with pipe clamp
40
Article # 28 040
Cover plate made of polymer surface water tight, black, Class A 15. Ventilation pipe necessary, incl. gasket 173-145 surface water tight, recessed for on-site tiling, grey, for tile thicknesses of 18 mm, Class A 15 with integrated grating, black, Class A 15 Gasket set
w
Ideal
ate roo consisting of: concrp rete f Counter flange made of polymer, incl. screws Elastomer waterproof membrane in NK/SBR 800 mm
for
590
10
40
83 071
414
180
Extension section
made of polymer, max. extension 180 mm, incl. gasket When multiple extension section are used make sure that access to valve is still possible !
83 070
414
Hole saw 50, 75, 110 for drilling Cover plate with drain 75, Class A 15
recessed for on-site tiling, grey, for tile thicknesses of 18 mm
100
50
83 055
47 200
Submersible pumps
50 75 110 -
Current Voltage Current Motor rating RPM Motor pro- Plug type P1 / P2 tection Alternating 230 V 2.2 A 480 W / 2800 min-1 integrated Schuko current 5 m cable 310 W
258
3,0
7,0
Lifting station Aqualift S for sewage free wastewater For installation in a concrete slab/floor, according to EN 12056
Twin lifting station Aqualift S for wastewater without sewage For interior installation according to EN 12056
Illustration and dimensioned drawing Article description Pressure connection 40 Article # 28 541
110
40
530
575 720
258
500
LGA
Type-tested
and monitored
with teed guaran quality tested
190 75
LGA
Type-tested
and monitored
with teed guaran quality tested
EN 12050 - 2
Submersible pumps
LGA
Type-tested
and monitored
with teed guaran quality tested
EN 12050 - 2
Catalogue 2.3
50
Performance diagram Minilift The KESSEL Minilift lifting station fits easily underneath any washbasin; it can also be connected to a washing machine, shower or other inlets. The station is equipped with a 300 W wastewater pump with a float control. The single hand snap closure means that special tools are not required to remove the pump for cleaning. The pressure pipe can be a PVC pipe 40 mm. It is also possible using a screw connection 11/2 inch to connect the pressure pipe to the lifting station.
[m]
Installation example
Pumping height m
Accessories
Pressure pipe set
incl. 5 m pressure pipe hose 40, Adaptor with pipe clamp for Art. # 28 570
40
Article # 28 040
32 500
(EPDM) Use KESSEL hole saw when drilling. for article numbers: 28 541, 28 570, 28 560
22
Hole saw
for drilling lateral surfaces for inlets and outlets 50, 75, 110 (Saw blade holder = 145 mm)
Potential-free contact
Relay max 42 V / 0.5 A for Art. # 28 541
80 072
Audible alarm
Voltage range 6 - 24 V DC for Art. # 28 541
Catalogue 2.3
20 162
Lifting station Aqualift F Duo XXL for wastewater with or without sewage For free installation in frost free areas
Illustration and dimensioned drawing Article description Power 2.6 kW 3.5 kW 4.8 kW Current connection 400 V 400 V 400 V Article # 28 638 28 639 28 640
Lifting station Aqualift F Duo XXL twin lifting station with closure valve
for wastewater with or without sewage (For use with grease separators size NS 10 and larger) for free standing installation in frost free areas Consists of: Polyethylene collection chambers, storage volume 750 liter, pumping volume 300 liter, pneumatic level control, twin 420 mm OD access / maintenance covers, 160 inlet ( 200 available upon request), inlet height 1055 mm, ventilation connection size 110. Twin wastewater pumps with macerating (cutting assembly) for pumping wastewater with or without raw sewage, IP 68 submersible pumps, Duty / Standby operation, 10 meter power cable length. Vertical pressure outlet with 110 connection and flange, with closure valve and integrated backflow preventer. Komfort control unit with mains power ON / OFF switch and multilingual digital display (EN, DE, FR, IT, PL, NL) showing current operational status, settings and logbook, IP 54 splash proof control unit housing, for wall mounting, operational voltage - 400 V DC, with potential free contact (BMS) connections. Total weight empty: approx 220 kg EN 12050 - 1
1837 2000
1055
Pumping height m
20 15 10 5
Type Power (P2) Intake Power (P1) Voltage Frequency Amperage Cable connections Media temperature Protection
XXL 2.6 kW 400 V XXL 3.5 kW 400 V XXL 4.8 kW 400 V 2.6 kW 3.5 kW 4.8 kW 3.3 kW 400 V DC 50 Hz 6.4 A 10 m Length, 7 x 1.5 mm2 35C IP 68 4.2 kW 400 V DC 50 Hz 7.9 A 10 m Length, 7 x 1.5 mm2 35C IP 68 5.6 kW 400 V DC 50 Hz 10.2 A 10 m Length, 7 x 1.5 mm2 35C IP 68
20
40
60
80
[Qm3/h]
Submersible pumps
52
Catalogue 2.3
Catalogue 2.3
53
Submersible pumps
- Professional advantages
Y ears
The Polyethylene Chamber Advantage offers a fully corrosion resistant chamber. All interior and exterior chamber walls are fully resistant to aggressive wastewaters and soils / groundwater which results in an extremely long operation life. Fully Automatic Operation of the lifting station which is controlled by an included control unit offering visual and acoustical alarms as well as operational status display.
n ty ra
Submersible pumps
KESSEL 100% watertight chambers means that no polluted wastewater can seep out of the storage chamber and more importantly no groundwater can enter the chamber which causes unnecessary pump operation and wear and tear.
54
Catalogue 2.3
10
20
30
40
[Qm3/h]
10
15
20
[Qm3/h]
2,0
3,0
4,0
5,0
6,0
7,0
7[Qm38,0 /h]
[m] 9 8 7 6 5 4 3 2 1 2 4 6
TPF 1000
[m] 10 9 8 7 6 5 4 3 2 1 2 4 6
KTP 1000
10 [Qm3/h]
10
12 [Qm3/h]
400 Volt Komfort control unit for lifting- and pumping stations Aqualift F
Available for single and twin systems User friendly navigation in multi-line display With self-diagnosis system SDS and memory function for the next service Displays the current measured values Simple setting of the parameters relevant for the function Operating hours counter Optional forwarding of alarm and general fault signals via a GSM interface Multilingual display (EN, DE, FR, IT, PL, NL)
Catalogue 2.3
55
Submersible pumps
[m] 16 14 12 10 8 6 4 2
KTP 500
Lifting station Aqualift F for wastewater with or without sewage in Komfort inspection chamber system 1000 (single station/twin station) according to EN 752 for underground installation
Illustration and dimensioned drawing Article description
Illustration shows single station Art. # 866 621B We recommend that the inspection chamber is ventilated to prevent the formation of condensation water. Installation depths (D): D1 1630 - 2130 mm D2 2130 - 2630 mm D3 2630 - 3130 mm D4 3130 - 3630 mm D5 3630 - 4130 mm D6 4130 - 4630 mm D7 4630 - 5130 mm
Installation depths D
Ventilation
EN 12050-1
Pumping capacity 1.1 kW Installation depth D in mm Single station: D 1: 1630 - 2130 D 2: 2130 - 2630 D 1: 1630 - 2130 D 2: 2130 - 2630 D 3: 2630 - 3130 D 4: 3130 - 3630 D 5: 3630 - 4130 Voltage Article # Class A/B Class D 867 611 B 867 621 B 866 611 B 866 621 B 866 631 B 866 641 B 866 651 B 868 611 868 621 868 631 868 641 868 651 B B B B B 867 611 D 867 621 D 866 611 D 866 621 D 866 631 D 866 641 D 866 651 D 868 611 868 621 868 631 868 641 868 651 D D D D D
Pumping capacity 2.2 kW Installation depth D in mm Single station: D 1: 1630 - 2130 D 2: 2130 - 2630 D 3: 2630 - 3130 D 4: 3130 - 3630 D 5: 3630 - 4130 D 6: 4130 - 4630 D 7: 4630 - 5130 Twin station: D 1: 1630 D 2: 2130 D 3: 2630 D 4: 3130 D 5: 3630 D 6: 4130 D 7: 4630 2130 2630 3130 3630 4130 4630 5130 Voltage Article # Class A/B Class D 866 711 866 721 866 731 866 741 866 751 866 761 866 771 868 711 868 721 868 731 868 741 868 751 868 761 868 771 B B B B B B B B B B B B B B 866 711 866 721 866 731 866 741 866 751 866 761 866 771 868 711 868 721 868 731 868 741 868 751 868 761 868 771 D D D D D D D D D D D D D D
mm mm mm mm mm mm mm mm mm mm mm mm
230 230 400 400 400 400 400 400 400 400 400 400
V V V V V V V V V V V V
mm mm mm mm mm mm mm mm mm mm mm mm mm mm
400 400 400 400 400 400 400 400 400 400 400 400 400 400
V V V V V V V V V V V V V V
Submersible pumps
Installation suggestion
400 V 2.2 kW
8 2,5
12
16 5
20
24
28 7,5
32
36 10
40
44 12,5
46
48 15
Type FPF 110 - 230 V FPF 110 - 400 V FPF 220 - 400 V Power (P2) 1.1 kW 1.1 kW 2.2 kW Intake 1.6 kW 1.4 kW 3.2 kW Power (P1) Voltage 230 V AC 400 V DC 400 V DC Frequency 50 Hz 50 Hz 50 Hz Amperage 7.3 A 2.7 A 5.4 A Fuses 16 A surge-proof 3 x 16 A surge-proof 3 x 16 A surge-proof Cable 10 m Length, 10 m Length, 10 m Length, connections 7 x 1.5 mm2 7 x 1.5 mm2 7 x 1.5 mm2 Media 40C 40C 40C temperature Weight (Pump) 23 kg 24 kg 24 kg Protection IP 68 IP 68 IP 68 S3 S3 S3 Operating 60% power on 60% power on 30% power on mode duration duration duration
Pumping height m
KESSEL - Professional advantages Variable upper section: inclinable height adjustable from 100 to 600 mm Simple to assemble with light-weight inspection chamber components and easy connection technique. Quick to mount with a high level of prefabrication (bottom part of inspection chamber with pressure pipe) and easy connection using fixed couplings for inlet and pressure pipe and bores with lip gaskets for ventilation and cable piping. Long-term reliability with an absolute water-tight inspection chamber system which is resistant to sedimentary deposits and aggressive media as well as root infiltration.
Catalogue 2.3
Komfort control unit (optional) with mains power ON / OFF switch and multilingual digital display (EN, DE, FR, IT, PL, NL) showing current operational status, settings and logbook
57
Submersible pumps
Fully automated operation with an electrical control unit with manual, off and automatic mode, optical and audible warning and alarm notification, detailed operation and warning display, integrated pump rotation check, antiblocking function, variable pump on and pump off settings.
Lifting station Aqualift F for wastewater with or without sewage in Komfort inspection chamber system 1000 (single station/twin station) according to EN 752 for underground installation
Pumping station Aqualift F (TPF 1000) with macerating / cutting pumps in inspection chamber system 600 (single station/twin station) according to EN 752 for underground installation
Illustration and dimensioned drawing Article description
Pumping station Aqualift F (TPF 1000) with macerating / cutting pumps in inspection chamber system 600 Single station/twin station
for wastewater with or without sewage For underground installation, installation depth D ....... Inspection chamber system 600 in PE-LLD, resistant to aggressive media, upper section made of polymer, vertically adjustable, cover Class A/B, D in cast iron according to EN 124. Groundwater resistant. Inlet 160, connection for pipe gasket for 110 according to EN 1401 (DIN 19534) and DIN 19537 each for ventilation or conduit pipe. Note: Consider frost free depth of pressure pipe Pressure pipe 40 mm outside diameter for PVC glue connection, with integrated non-return flap. Current: 230 V ~ 50 Hz. Power cable length: 10 m.
1
860
Installation depths D
TPF 1000 with removable, float switch controlled pump, plug in ready (230 V power connection) TPF 1000 with removable, air pressure controlled pump, IP 54 SDS control unit (230 V / 50 Hz) TPF 1000 Duo with twin removable, air pressure controlled pumps, IP 54 SDS control unit (230 V / 50 Hz)
For installations without explosion proof requirements Handles groundwater depths up to 2000 mm EN 12050 (max 2 WC connections)
1
Installation depth D in mm D1 Lifting stations for exterior installation D2 D3 800 - 1250 1300 - 1750 1800 - 2250 Article # Class B 827 710 B 827 720 B 827 730 B Class D 827 710 D 827 720 D 827 730 D Class B 827 711 B 827 721 B 827 731 B
2
Article # Class D 827 711 D 827 721 D 827 731 D Class B 826 711 B 826 721 B 826 731 B
3
Article # Class D 826 711 D 826 721 D 826 731 D
Pumping height m
TPF 1000
4 6 8 Pumping capacity Q (m 3 / h)
KTP 1000
10 [Qm3/h]
Type Submersible pumps Current type Voltage Current Motor rating P1/P2 RPM Motor protection Operating mode
KESSEL - Professional advantages Variable upper section: inclinable height adjustable from 100 to 600 mm Inexpensive complete system For draining wastewater with or without sewage For backwater protection connected to a separator For draining basements, yards or driveways
Alternating current 230 V 4.9 A 1080 W / 620 W 2800 min-1 integrated S3 - 30%
58
Catalogue 2.3
Article description
Pumping station Aqualift F (AP 501) in Komfort inspection chamber system 800 / 1000
for wastewater with or without raw sewage For underground installation, installation depth D 1480 to 1980 mm Consisting of: Inspection chamber system KESSEL 800 / 1000 in PE-HD water-tight, resistant to aggressive media, extension section made of polymer, continuous height and level adjustment, cover Class A/B, D in cast iron according to EN 124. Groundwater resistant. Inlet 160, connection for pipe seal for 110 according to EN 1401 for ventilation pipes and cable piping respectively, pumping volume approx. 150 l Pressure pipe ready mounted with backwater flap, closure valve and float switch for level control with cable length 10 m, pressure pipe connection PE-HD 63 mm and 90 mm. Single or twin submersible pump(s) AP 501 0.75 kW (without explosion protection), with non-chokable impeller to pump wastewater with or without sewage, submersible (IP 68), electrical cable length 10 m.
1
AP 501 with removable, float switch controlled pump, plug in ready (230 V power connection) AP 501 Tronic with removable, float switch controlled pump, 3 floats (OFF, ON, ALARM) with control unit (IP 54), operating voltage 400 V DC at 50 Hz, with potential-free contact AP 501 Duo with twin removable and float switch controlled pump, 4 floats (OFF, ON 1, ON 2, ALARM), with control unit (IP 54, operating voltage 400 V DC at 50 Hz, with potential-free contact
Illustration shows Art. # 1000-HA3-521B Installation 800 1480 - 1980 mm 1980 - 2480 mm 2480 - 2980 mm depths (D) 1000 1630 - 2130 mm 2130 - 2630 mm 2630 - 3130 mm 800 1 Installation depth D1 D2 D3 Article # Class B 800-HA1-501B 800-HA2-501B 800-HA3-501B Class D 800-HA1-501D 800-HA2-501D 800-HA3-501D
D1 D2 D3
For installations without explosion proof requirements Handles groundwater depths up to 500 mm 800 2 Article # Class B 800-HA1-511B 800-HA2-511B 800-HA3-511B Class D 800-HA1-511D 800-HA2-511D 800-HA3-511D Class B 1000-HA1-521B 1000-HA2-521B 1000-HA3-521B 1000
3
Class D 1000-HA1-521D 1000-HA3-521D Lifting stations for exterior installation Submersible pumps 1000-HA2-521D
Article #
Pumping height m
10 8 6 4 2 0 0 2 4 6 8 10 12
AP 501
14
16
18
20
22
Pumping capacity Q (m 3 / h)
Power Intake power Amperage Voltage Cable length Protection 230 V IP 68; without 6A 10 m 1.25 kW Mono with 0.75 kW at 50 Hz explosion protection float switch Type 0.75 kW Mono Tronic / Duo 1.1 kW 2.8 A
400 V at 50 Hz
10 m
KESSEL - Professional advantages Variable upper section: inclinable height adjustable from 100 to 600 mm Simple to assemble with light-weight inspection chamber components and easy connection technique. Long-term reliability with an absolute water-tight inspection chamber system which is resistant to sedimentary deposits and aggressive media as well as root infiltration.
Catalogue 2.3
Fully automated operation with an electrical control unit with manual, off and automatic mode, optical and audible warning and alarm notification, detailed operation and warning display, integrated pump rotation check, antiblocking function, variable pump on and pump off settings.
59
Pumping station Aqualift F (AP 501) in Komfort inspection chamber system 800 / 1000 according to EN 752 for underground installation
Pumping station Aqualift F for wastewater with or without sewage in Komfort inspection chamber system 1000 (single station/twin station) according to EN 752 for underground installation
Illustration and dimensioned drawing Article description
EN 12050-1 Pumping capacity 1.9 kW Installation depth D in mm Single station: D 1: 1630 - 2130 D 2: 2130 - 2630 D 3: 2630 - 3130 D 4: 3130 - 3630 D 5: 3630 - 4130 D 6: 4130 - 4630 D 7: 4630 - 5130 Twin station: D 1: 1630 D 2: 2130 D 3: 2630 D 4: 3130 D 5: 3630 D 6: 4130 D 7: 4630 Pressure pipe * 63/90 63/90 63/90 63/90 63/90 63/90 63/90 Article # Class A/B Class D 865 710 B 865 720 B 865 730 B 865 740 B 865 750 B 865 760 B 865 770 B *) 90 by 864 710 B 864 720 B 864 730 B 864 740 B 864 750 B 864 760 B 864 770 B *) 90 by 865 710 D 865 720 D 865 730 D 865 740 D 865 750 D 865 760 D 865 770 D sawing off 864 710 D 864 720 D 864 730 D 864 740 D 864 750 D 864 760 D 864 770 D sawing off
mm mm mm mm mm mm mm
mm mm mm mm mm mm mm
Submersible pumps
mm mm mm mm mm mm mm
mm mm mm mm mm mm mm
Installation in the Komfort inspection chamber 1000 exterior to buildings Einbau im KESSEL-Komfort-Schachtsystem LW system 1000 auerhalb des Gebudes
Pumping height m
25 20
Pump type Power Intake power Amperage Fuses Voltage Cable length Protection Pump type Power Intake power Amperage Fuses Voltage Cable length Protection
10
15
20
Pumping capacity Q (m 3 / h)
0 0,5 1 1,5 2 2,5 3 3,5 4 4,5 5 5,5 6
Pumping capacity Q (l / s)
TPF 1.9 KE 1.9 kW 2.6 kW 4.5 A 3 x 16 A surge-proof 400 V DC at 50 HZ 10 m Length, 7 x 1.5 mm2 IP 68 Ex-protection
KESSEL - Professional advantages Variable upper section: inclinable height adjustable from 100 to 600 mm Simple to assemble with light-weight inspection chamber components and easy connection technique. Quick to mount with a high level of prefabrication (bottom part of inspection chamber with pressure pipe) and easy connection using fixed couplings for inlet and pressure pipe and bores with lip gaskets for ventilation and cable piping. Long-term reliability with an absolute water-tight inspection chamber system which is resistant to sedimentary deposits and aggressive media as well as root infiltration.
Catalogue 2.3
Komfort control unit (optional) with mains power ON / OFF switch and multilingual digital display (EN, DE, FR, IT, PL, NL) showing current operational status, settings and logbook.
61
Submersible pumps
Fully automated operation with an electrical control unit with manual, off and automatic mode, optical and audible warning and alarm notification, detailed operation and warning display, integrated pump rotation check, antiblocking function, variable pump on and pump off settings.
TPF 1.3 KE 1.3 kW 1.75 kW 3.56 A 3 x 16 A surge-proof 400 V DC at 50 HZ 10 m Length, 7 x 1.5 mm2 IP 68 Ex-protection
Pumping station Aqualift F for wastewater with or without sewage in Komfort inspection chamber system 1000 (single station/twin station) according to EN 752 for underground installation
Pumping station Aqualift S for wastewater without sewage / rainwater in inspection chamber system 600 (single station/twin station) according to EN 752 for underground installation
Illustration and dimensioned drawing Article description
860
Installation depths D
KTP 500 / 1000 float switch controlled removable pump for conductive or non-conductive fluids. Start up power: 0.5 /1.0 kW. KTP 500 / 1000 Tronic with removable air pressure controlled pump for conductive or non-conductive fluids, with SDS control unit. Start up power: 0.5 /1.0 kW.
KTP 500 / 1000 Duo with removable twin pump and SDS control unit sensors operate in conductive and non-conductive fluids. Start up power: 2 x 0.5 /1.0 kW. Handles groundwater depths up to 2000 mm
3
EN 12050 - 2
KTP 500 Installation depth D in mm D1 D2 D3 800 - 1250 1300 - 1750 1800 - 2250 KTP 1000 Installation depth D in mm D1 D2 D3 800 - 1250 1300 - 1750 1800 - 2250
1
Article # Class A/B Class D 825 810 B 825 820 B 825 830 B 825 810 D 825 820 D 825 830 D
2
Article # Class A/B Class D 825 811 B 825 821 B 825 831 B 825 811 D 825 821 D 825 831 D
3
Article # Class A/B Class D 824 811 B 824 821 B 824 831 B 824 811 D 824 821 D 824 831 D
1
Article # Class A/B Class D 827 810 B 827 820 B 827 830 B 827 810 D 827 820 D 827 830 D
2
Article # Class A/B Class D 827 811 B 827 821 B 827 831 B 827 811 D 827 821 D 827 831 D
3
Article # Class A/B Class D 826 811 B 826 821 B 826 831 B 826 811 D 826 821 D 826 831 D
KTP 1000 230 V 4.9 A 1180 W / 720 W 2800 min-1 integrated S3 - 30%
Submersible pumps
Pumping height m
Alternating current Alternating current 230 V 2.2 A 480 W / 310 W 2800 min-1 integrated S1
10
12 [Qm3/h]
Pumping capacity Q (m 3 / h)
62
Catalogue 2.3
Article description
610
Installation depth D
2055
1320
Illustration shows single station Art. # 865 821 B Installation depths (D): D1 1630 - 2130 mm D2 2130 - 2630 mm D3 2630 - 3130 mm D4 3130 - 3630 mm D5 3630 - 4130 mm D6 4130 - 4630 mm D7 4630 - 5130 mm KTP 500 Installation depth D in mm D1 D2 D3 D4 D5 D6 D7 1630 - 2130 2130 - 2630 2630 - 3130 3130 - 3630 3630 - 4130 4130 - 4630 4630 - 5130 KTP 1000 Installation depth D in mm D1 D2 D3 D4 D5 D6 D7 1630 - 2130 2130 - 2630 2630 - 3130 3130 - 3630 3630 - 4130 4130 - 4630 4630 - 5130
1 pump with float switch Article # Class A/B Class D 867 810 B 867 820 B 867 830 B 867 840 B 867 850 B 867 860 B 867 870 B 867 810 D 867 820 D 867 830 D 867 840 D 867 850 D 867 860 D 867 870 D
1 pump with SDS-Control Unit Article # Class A/B Class D 867 811 B 867 821 B 867 831 B 867 841 B 867 851 B 867 861 B 867 871 B 867 811 D 867 821 D 867 831 D 867 841 D 867 851 D 867 861 D 867 871 D
2 pumps with SDS-Control Unit Article # Class A/B Class D Submersible pumps
63
866 811 B 866 821 B 866 831 B 866 841 B 866 851 B 866 861 B 866 871 B
866 811 D 866 821 D 866 831 D 866 841 D 866 851 D 866 861 D 866 871 D
Catalogue 2.3
500
420
Pumping station Aqualift S for wastewater without sewage / rainwater in Komfort inspection chamber system 1000 (single station/twin station) according to EN 752 for underground installation
Difficulty finding the product you are looking for ? KESSEL offers a fully staffed Individual Solutions Department with experience in designing and manufacturing drainage products exactly meeting your specifications. For additional information please take a look at the Individual Solutions section of this catalogue on page 201 or contact us directly to discuss your requirement. Contact information is found on page 3.
64
Catalogue 2.3
Catalogue 2.3
Submersible pumps
65
Submersible pumps
281
EN 12050 - 1
KTP 500: Model without float switch 11/4 inch Model with float switch 11/4 inch KTP 500 TITAN Model without float switch 11/4 inch Model with float switch 11/4 inch 28 850 28 750 28 810 28 710
LGA
Type-tested
and monitored
with teed guaran quality tested
EN 12050 - 1
Pumping height m
KTP 1000 Alternating current 230 V 4.9 A 1080 W / 620 W 2800 min-1 integrated S3 - 30%
Voltage Current Motor rating P1/P2 RPM Motor protection Operating mode
10
12 [Qm3/h]
Pumping capacity Q (m 3 / h)
Submersible pumps
66
Catalogue 2.3
Model without float switch with/without float switch 1 inch With backwater flap, pivotable connection. Intake power: 340 W. Model Voltage: 230 V ~ 50 Hz. with float switch max. pumping height: 6 m. 1 inch max. pumping capacity: 8 m3/h. Max. submersible depth: 10 m. max. particle size: 10 mm. Pressure connection: 1 inch side / vertical Cable length: 10 m. Removable intake basket - reduction in the water level to 8 mm possible.
28 740
28 840
LGA
Type-tested
and monitored
with teed guaran quality tested
EN 12050 - 1
Lifting stations for interior installation
67
Pumping height m
4 3 2 1 1 2 3 4 5 6 [Qm3/h]
Current Voltage Current Motor rating type P1 / P2 Alternating 230 V 1.9 A 340 W / current 220 W
RPM
Pumping capacity Q (m 3 / h)
Catalogue 2.3
Submersible pumps
Article description
Article # 20 400
With audible alarm Mains supply 230 V ~ 50 Hz. Including potential-free contact.
170
196
Control units can be combined with the KESSEL submersible pumps KTP 300 and KTP 500 (page 66 and 67)
65
20 410
Function:
Alarm Pre-alarm Pump ON Pump OFF
With audible alarm Mains supply 230 V ~ 50 Hz. Including potential-free contact. with sensor switches: For conductive liquids (household wastewater, not rainwater) Cable length 5 m, cannot be extended. Control units can be combined with the KESSEL submersible pumps KTP 300 and KTP 500 (page 66 and 67)
196
170
65
20 450
Function:
With audible alarm Mains supply 230 V ~ 50 Hz. Including potential-free contact. With 3 float switches: For conductive and nonconductive liquids (e.g. rainwater) Cable length 10 m, can be extended to 30 m. Control units can be combined with the KESSEL submersible pumps KTP 300 and KTP 500 (page 66 and 67)
Alarm
Accessories
Audible alarm
Electronic audible alarm (continuous tone) with power cable. Minimum current consumption 5 - 25 mA, audible tone 4.7 KHz - 90 dB, large voltage range 6 - 24 V DC; Dimension 31 x 15 mm; approx 7 g. Cable length 20 m (special lengths available on request). Matches control units: Aqualift S Tronic, Pumpfix F, FKA backwater valves, warning device, filling level monitoring, Niwotronic, Duo control unit. 20 162
196
170
Potential-free contact
Change-over contact 42 V / 0.5 A; Additional circuit board with a potential-free contact, e.g. for connecting the control unit to the central I&C equipment of the building. Matches control units: Aqualift S Tronic, Pumpfix F, FKA backwater valves, warning device, filling level monitoring, Niwotronic.
80 072
68
Catalogue 2.3