Sei sulla pagina 1di 2

CGa - Gold S er

iesGasBoiler
W eil- McLain

Water,
Natural Draft
NAT’L or LP
MBH: 52-245
Avg. Efficiency: 83%

GOL D SERIES- GA S BOIL ER

HIGHEFFICIEN CY

EA S YTO IN S TA LL A N D S ERV ICE

MA DE W ITHW EIL- McLA IN QUA LITY

www.weil- m clain.com
USA
M A D E IN THE

Rati
ng s

Note s:
(1)A dd “SPD” for boiler w ith stan din g pilot;“PID” for boiler
w ith electron ic ign ition system . For SPD m odels, add
“N ” for n atural gas, “L ” for propan e (propan e n ot
av ailable for PID).
(2)Based on stan dard test procedures prescribed byth e
Un ited States Departm en t of En ergy.
(3)N et I= B= R ratin gs are based on n et in stalled radiation
of sufficien t quan tityfor th e requirem en ts of th e
buildin g an d n oth in g n eeds tobe added for n orm al
pipin g an d pick-up. Ratin gs are based on apipin g an d
pick-up allow an ce of1.15. A n addition al allow an ce sh ould
be m ade forun usual pipin g an d pick-up loads.
CGaboilers
le are C.S.A . design certified for in stallation on
com bustible floorin g. Tested for50 psiw orkin g pressure.

Di
m e nsi
ons

Note s: (1)Circulator
flan ge supplied w ith
boiler is sam e size
as recom m en ded
pipe size. For supply
an d return boiler
tappin g size, see
in stallation m an ual.

Note : Boiler circulator is sh ipped loose. Circulator m aybe m oun ted on eith er boiler
supplyor return pipin g. See dim en sion ch art for pipe size of circulator flan ge prov ided.

Standard and A ddi


tionalEqui
p m e nt
Standard Equi p m e nt: 30 PSIA SM E ReliefValve (boiler section s A ddi ti
onalEp ui p m e nt:
FactoryTested tested for 50 PSIw orkin g pressure) Taco0 0 7 Circulator
Tw o-Piece Top Jacket Pan el Com bin ation Pressure-Tem perature Gauge Expan sion Tan k Package (expan sion tan k, fill
In sulated Exten ded Steel Jacket Drain Valve & ch eck valve, autoair ven t an d fittin gs):
Cast Iron Section s w ith Built-in A ir Separator HIG HEFFICIENCY M ODEL - SPD # 10 9-sizes 25 th ru 5;# 110 -sizes 6 th ru 8.
Radiation Plates Con stan t Burn in g, Th erm ally-Superv ised Sh ipped in separate carton .
Vertical Draft Hood Pilot System W -M 5 & 10 Year Hom eow n er Protection Plan
A utom atic Ven t Dam per Th erm ocouple W -M In direct-fired W ater Heaters
Com bin ation Gas Valve for 24 Volt Com bin ation RelayReceptacle an d W -M M axiflo® Pool Heaters
W irin g Harn ess 40 VA Tran sform er W -M Baseboard Un its
Non -L in tin g Pilot Burn er Plug-in Circulator Relay
Stain less Steel Burn ers HIG HEST EFFICIENCY M ODEL - PID
Electrical Jun ction Box In tegrated Boiler Con trol M odule w ith
Rollout Th erm al Fuse Elem en t In term itten t Electron ic Ign ition System
High -L im it Tem perature Con trol & In dicator/ Diagn ostic L igh ts
Circulator (w h en ordered) 40 VA Tran sform er
Spill Sw itch Plug-in Con n ector an d W irin g

In th e in terest ofcon tin ual im provem en ts in product an d perform an ce, W eil-M cL ain reserves th e righ t toch an ge specification s w ith out n otice.