ISOFIRE ROOF 1000

This panel is designed for sloped roof use. Its mineral fibre core guarantees incombustibility, as well as assuring an excellent thermal insulation. ISOFIRE ROOF 1000 was designed to meet the growing requirements in terms of re behaviour, guaranteeing at the same time high mechanical performances.

1000 250 40 thickness 25

NOTES FOR CONSULTATION OF THE DATA CARD

(reference should be made to norm AIPPEG

for anything not mentioned herein)

METAL SURFACES - Sendzimir galvanised steel sheet (UNI-EN 10147). - Galvanised steel sheet, pre-painted by means of a Coil Coating process. - Aluminium alloy sheet, mill nish, stucco embossed or pre-painted (UNI 9003). - Continuous pre-painting process with a 5 m thick primer and a 20 m paint on the items visible side. Available in the following lines: PS-PX-PVDF (On request, ISOPAN can also supply very anticorrosive special products). INSULATING LAYER Insulating layer made of high-density mineral bres (100 kg/m3, m = 0.040 W/mK at 10C). LOAD LIMITS - Deformation: a deection equal to or lower than 1/200 L of the free span is admitted. - Deection: it is assumed that the bending stress is completely absorbed by the steel support sheets.

- Cut: it has been assumed that the cutting stress is absorbed partly by the steel support sheets and partly by the insulation material. The data specied in tables 1 and 2 are to be considered as indicative. The designer will have to verify and adjust such details with regard to every specic application. FIXING INSTRUCTIONS The designer will have to evaluate the conditions of using the product, according to the local climatic situation. It will be necessary to adopt some particular precautions when xing panels with aluminium or copper surfaces. For further information, please refer to the RECOMMENDATIONS FOR ASSEMBLING RIBBED SHEETS AND INSULATED METAL PANELS, issued by the AIPPEG Association. The maximum recommended length for correctly handling mineral bre panels is 6000 mm.

1 - AIPPEG (Associazione Italiana Produttori Pannelli ed Elementi Grecati): Italian Association of Panels and Ribbed Items Manufacturers.

FIXING INSTRUCTIONS
Type of xing: Screw type and shank: ROOF APPLICATION PVC screw-washer (*) self-tapping, 6.0 mm for 3 mm thick supports; self-threading, 6.3 mm for < 3 mm thick supports, with an incorporated drive washer; length: panel nominal thickness + 60 70 mm One for each rib (terminal or overlapping supports); one every two ribs (intermediate supports) WALL APPLICATION PVC screw-washer (*) self-tapping, 6.0 mm for 3 mm thick supports; self-threading, 6.3 mm for < 3 mm thick supports, with an incorporated drive washer; length: panel nominal thickness + 20 30 mm Two for each panel (terminal supports); one for each panel (intermediate supports)

Quantity:

(*) In the event of a considerable structural low, it is advisable to interpose a 50 mm washer. For panels with aluminium or copper supports, please require ISOPANs special instructions.

OVERLOADS - SPANS
SHEET STEEL THICKNESS 0.5 mm EVENLY DISTRIBUTED LOAD
kg/m2 80 100 120 150 200 daN/m2 78 98 117 147 196 330 305 270 220 165 420 390 400 335 255 50 80 PANEL THICKNESS mm 100 MAX. SPAN cm 460 435 415 390 310 500 470 450 420 365 535 500 480 450 420 365 330 290 240 175 465 415 395 325 275 120 150 50 PANEL THICKNESS mm 80 100 MAX. SPAN cm 510 455 405 350 285 550 480 435 365 290 575 505 440 365 305 120 150

SHEET STEEL THICKNESS 0.6 mm EVENLY DISTRIBUTED LOAD


kg/m2 80 100 120 150 200 daN/m2 78 98 117 147 196 350 325 290 235 180 450 420 400 355 275 50 80 PANEL THICKNESS mm 100 MAX. SPAN cm 495 465 445 415 340 535 505 480 450 400 570 540 515 480 460 390 355 315 260 195 500 450 400 350 300 120 150 50 PANEL THICKNESS mm 80 100 MAX. SPAN cm 550 490 440 380 320 590 520 470 400 330 615 550 480 400 350 120 150

WEIGHTS OF PANELS
STEEL THICKNESS
0,5 Isore Roof panel assembly system 0,6

WEIGHT
kg/m2 kg/m2

NOMINAL THICKNESS OF PANEL mm


50 13,5 15,50 80 16,4 18,30 100 18,5 20,20 120 20,4 22,30 150 23,2 25,30

DIMENSIONAL TOLERANCES THERMAL INSULATION


K
W/m2 K kcal/m h C
2

DEVIATIONS mm
Length Effective width Thickness Orthometry and rectangularity Misalignment of internal metal facing 100 0,36 0,32 120 0,3 0,26 150 0,25 0,22 5 5 2 3 3

NOMINAL THICKNESS OF PANEL mm


50 0,72 0,64 80 0,44 0,38

On request, ISOPAN can issue the following re behaviour certications: FIRE REACTION Panels ISOFIRE ROOF 1000 eld-tested in accordance with the Ministerial Decree dated 26th June 1984, have been granted the re reaction category 0-0. FIRE RESISTANCE (circular letter number 91, dated 14th September 1961) Panels ISOFIRE ROOF 1000 eld-tested have obtained the following results: REI level 30 for 50 mm thick panels REI level 60 for 80 mm thick panels REI level 120 for 100 mm thick panels REI level 180 for 150 mm thick panels

DRAFT OF SPECIFICATIONS
Nominal thickness: Effective width: External support: Internal support: Insulation: Fixing: mm mm 1000 ribbed (40 mm high ribs, 250 mm axle spacing), in galvanised steel/aluminium, thickness mm visible side: line , with 5 microns of primer and 20 microns of painting , colour kcal/m2 h C ; type of screw ; quantity , colour microribbed, in galvanised steel/aluminium, thickness mm with 5 microns of primer and 20 microns of painting carried out by high-density mineral bres (100 kg/m3) W/m2, K type of xing device Coeff. of thermal transmission: K = , prepainted visible side: line , prepainted