Documenti di Didattica
Documenti di Professioni
Documenti di Cultura
US $/Barrel
120,00 100,00 80,00 60,00 40,00 20,00 0,00 2000 2001 2002 2003 2004 2005 2006 2007 2008 2009 2010 2011 2012
Modern buildings are better insulated thermally and windows are becoming more dense. In this way, naturally association for thermos arises, in which the coffee is still hot after 12 hours. The only negative side is that we are living in this thermos. People spend between 70% and 90% of their live time indoor. This lack of fresh air leads to decrease in working ability, allergies and diseases. This is also true for our children playing at home.
The thermos - modern building should be ventilated and enough quantity of fresh air should be provided for the people. This is the first part of the task. The second part is called - heat recovery ventilation.
month
year
We reserve the right to introduce alternations both in design and technical data without prior notice, due to continued product development.
Description: Compact heat recovery units are designed for ventilation of: - Small houses and apartments - Offices - Small shops High efficiency heat recovery ventilation up to 85% Working temperature from -200 to +400 Construction: - Construction of anodized aluminium profiles. - Panels with internal insulation - 13 mm. - High efficiency heat exchanger up to 85% - Double inlet centrifugal fans 230V - IP 44 - Filters for fresh and exhausted air - class G4 (EN779) - Round connections for the duct system - Drain tray - Inspection doors from below
Options: - Double panels sandwich type 25. - Filter F7 for fresh air - Automatic bypass (on / off ) - Hangers for ceiling installation - Powder coating of the panels - Pre-heater and additional electric heater Control: - Control of the fan speed (rpm) - Dirty filter signalization - Control of the bypass free cooling - Control of the electric heater - Control of the air quality
80%
External pressure
75% 74%
70%
EVB 04HiE EVB 06HiE
Air flow The efficiency is determined on equal mass flow rates of both air flows and without condensation.
Model
EVB 04 HiE Home VB 06 HiE Office
Dimensions [mm]
L D N
Fans
2 185 W 2 220 W
Max. current
0,81 A 1,01 A
700 700
290 380
1400 1400
200 250
130 160
63 74 70 39
125 67 63 41
250 67 59 37
500 63 53 28
1000 60 49 26
2000 59 34 26
4000 56 31 21
8000 52 26 15
We reserve the right to introduce alternations both in design and technical data without prior notice, due to continued product development.
InSTAllATIOn SchemeS
Home