Product Data Sheet Edition 11, 2006 Version no. 08.

04

Sikaplan 12 G
Product Description
Polyvinylchloride plastified (PVC-P) membrane, reinforced with woven fabric Waterproofing of flat and exposed roofs. Best resistance against weathering High resistance against: ageing - hail - sparkling fire and radiant heat Resistant against common environment-influence High resistance against UV, VI, IR-rays High resistance against mechanically influences High tensile strength and elongation High stable in change of dimensions Excellent flexibility in cold High water vapour permeability Best weldability Not resistant against bitumen Fire behaviour as per DIN 4102/part1, class B2 and SIA 183/2. Resistant against sparking fire and radiant heat as per DIN 4102/part7 Planning and installation of underground structures as per SIA 271 and DIN. Quality management system as per DIN EN ISO 9001. Quality control by external independent laboratories. Official quality certificates and agreements. Thickness 1.20 mm Length 20.00 m Width Packing unit Weights Roll M2 61.20 kg 1.53 kg 47.10 kg 30.60 kg 23.60 kg

Construction

Uses Advantages

Standards

Product Data
Thickness 2.00 m 20 rolls = 800 m2 1.54 m 20 rolls = 616 m2 1.00 m 20 rolls = 400 m2 0.77 m 20 rolls = 308 m2 Top layer: Light grey / bottom layer: dark grey Rolls shall be stored in horizontal position, protected against sunlight, in cool and dry place.

Colour Storage

Technical Data
Characteristics according to DIN 16938 Test as per DIN 16726 Stone Floor Sheet General appearance Straightness (g) and flatness (p) Thickness (d) Requirement as per DIN 16938 Free from blisters, cracks and capillaries g 50mm / p 10mm values Passed g < 15mm / p <2mm

Tensile strength longitudinal and traversal Elongation longitudinal and traversal Seam Strength Tear propagation strength longitudinal and traversal Behaviour under hydrostatic pressure

Deviations:-0.10mm/+0.20mm Deviations -0 mm/+0.08 mm average value of effective thickness lowest single value 1.17mm lowest single value1.00mm 800 N/mm2 > 1100 N/mm2 10% Crack must occur next to seam 180 N Testing pressure 2 bar over 24h watertight > 15 % passed > 250 N passed

SikaplanPP 12 G

1/3

Requirement as per DIN 16938 Puncture resistance Weight of impacting mass 500g failing height 300m tight Dimensional change after 1.00 % storage at +80C Appearance after storage No blisters in heat Behaviour when folding in No cracks at -20C cold Determination of water 30 000 vapour permeability () Root Resistance No root penetrations Membranes after laboratory testing General appearance after Free from blisters and thermal ageing capillaries Behaviour when folding in No cracks at -20C cold after thermal ageing No cracks at -20C Behaviour when folding in cold after artificial weathering Behaviour when folding in No cracks at -20C cold after storage in aqueous solutions

Test as per DIN 16726

values Tight at falling height 500 mm < 0.5% passed No cracks at -35C 20 000 Passed Passed No cracks at -30C No cracks at -30C No cracks at -30C

Technical Data

Characteristics according to Test as per SIA V 280 SIA V 280, edition 1996 Thickness

Uniaxial tension test

Requirements as per SIA V 280 deviation from nominal thickness: - 5 % /+ 10% lowest single value +/-10% min. 10%

Values deviation from nominal thickness: +2% lowest single value 1 % longitudinal 15 % transversal 15 % passed longitudinal 0.30% transversal 0.30% passed 18.000 Passed - 0.60 % (decrease) 10 % class 0 rigid backing 18 m/s flexible backing > 30 m/s change of mass M 0.70 % class 0 passed fire class 4 smoke class 2 passed passed passed tight at falling height of 450mm passed

Low temperature folding no cracks at 20C Heat distortion < 0.50%, Water vapour permeability () Ozone resistance no blisters no requirement

all 3 samples must show scale 0 Heat ageing weight decrease < 2% decrease of uniaxial tension < 30%, ozone resistance: class 0 Hail resistance approached damaging speed 17m/s Artificial weathering change of mass M < 3%, 5000h, class 0 Root resistance no root perforation ingrown root must die off Fire class fire class 4, smoke class 1 Behaviour in warm water low temperature folding: no cracks at 20C, decrease of uniaxial tension < 30%, change of mass 4% Mechanical puncture resistance tight at a height of 300mm falling mass 500g Joint strength rupture must occur outside of weld, slipping or peeling of welded parts not allowed

SikaplanPP 12 G

2/3

Application
Structure of surface Fixing method Installation procedure Important Notes

Particularities

structured Loosely laid and mechanically fastening According to the valid installation instruction of manufacturer. Not resistant against tar, bitumen, oil- and solvent containing mediums Not resistant in direct contact against thermal insulation materials, such as Polystyrene,-and Polyurethane-hardfoam, as well as other plastics than PVC Recycling of old products Auxiliary products: Trocal S or Sikaplan 18 D, unreinforced membranes for detailing works, as well as prefabricated elements for corners and pipe penetrations, and Sika-Trocal PVC-coated metal sheet, type S Membranes in other colours of top layers on inquiry: slate grey approx. RAL 7015 green approx. RAL 6061 brick red approx. RAL 8004 white approx. RAL 9010
The information, and in particular, the recommendations relating to the application and end-use of Sika products, are given in good faith based on Sika's current knowledge and experience of the products when properly stored, handled and applied under normal conditions in accordance with Sikas recommendations. In practice, the differences in materials, substrates and actual site conditions are such that no warranty in respect of merchantability or of fitness for a particular purpose, nor any liability arising out of any legal relationship whatsoever, can be inferred either from this information, or from any written recommendations, or from any other advice offered. The user of the product must test the products suitability for the intended application and purpose. Sika reserves the right to change the properties of its products. The proprietary rights of third parties must be observed. All orders are accepted subject to our current terms of sale and delivery. Users must always refer to the most recent issue of the local Product Data Sheet for the product concerned, copies of which will be supplied on request.

Legal notes