Documenti di Didattica
Documenti di Professioni
Documenti di Cultura
MOLDED CASE CB OF A GIVEN FRAME SIZE WITH ADJUSTABLE TRIP SETTINGS NORMALLY OPEN MOMENTARY PUSHBUTTON NORMALLY CLOSED MOMENTARY PUSHBUTTON NORMALLY OPEN CONTACT NORMALLY CLOSED CONTACT
WALL MOUNTED COMPACT FLOURESCENT OR H.I.D. LUMINAIRE, UPPER CASE LETTER IDENTIFIES FIXTURE TYPE. SURFACE MOUNTED OR SUSPENDED INDUSTRIAL FLUORESCENT FIXTURE NO LENS. UPPER CASE LETTER IDENTIFIES THE FIXTURE TYPE. DARKENED AREA INDICATES EMERGENCY POWERED BY A BATTERY PACK\INVERTER.
PP21-2,4,6
ARROWS ALL CONDUIT SHALL CONTAIN A GREEN INSULATED GROUND WIRE SIZED IN ACCORDANCE WITH 2008 NEC TABLE 250.122, UNLESS OTHERWISE NOTED. CONDUIT RUN UNDERGROUND OR IN CONCRETE SLAB/TOPPING OR IN CRAWL SPACE CONCEALED CONDUIT RUN ABOVE GRADE EXPOSED CONDUIT RUN ABOVE GRADE
in
ee
ring
& Servic
D es
Ae
iv i
Mark Description Date Appr.
Ae
RECESSED OR SURFACE MOUNTED FLUORESCENT TROFFER FIXTURE. UPPER CASE LETTER DESIGNATES THE FIXTURE TYPE. DARKENED AREA INDICATES EMERGENCY FIXTURE POWERED BY A BATTERY PACK\INVERTER.
A Ae
ELECTRIC METER
A Ae
SURFACE MOUNTED FLUORESCENT LIGHT FIXTURE W/ LENS. UPPER CASE LETTER DESIGNATES THE FIXTURE TYPE. DARKENED AREA INDICATES EMERGENCY FIXTURE POWERED BY A BATTERY PACK\INVERTER. WALL(SURFACE) MOUNTED FLUORESCENT LIGHT FIXTURE W/ LENS. UPPER CASE LETTER DESIGNATES THE FIXTURE TYPE. DARKENED AREA INDICATES EMERGENCY FIXTURE POWERED BY A BATTERY PACK\INVERTER. EXIT LIGHT (SINGLE FACE)
3A
SA 15KV
SURGE ARRESTOR - VOLTAGE RATING AND CLASS AS NOTED GROUND CONNECTION - TO STANDARD ROD TYPE ELECTRODE TO NEAREST STRUCTURAL STEEL (#6 MIN. CONDUCTOR IF NOT SHOWN) OR AS NOTED.
75
EXIT LIGHT (DOUBLE FACE)
WP H 30
S S
SS
S TO S S3 S4 SD SF
MANUAL STARTER WITH THERMAL OVERLOADS SINGLE POLE SWITCH THREE WAY SWITCH FOUR WAY SWITCH DIMMER SWITCH THREE SPEED, FOUR POSITION FAN CONTROL SWITCH RATED FOR NO. OF FANS INDICATED. WALL MOUNTED OCCUPANCY SENSOR
48" AFF
FA
M WP
P H
SD
EFX
M 12
MOTOR - EQUIPMENT SCHEDULE IDENTIFICATION AS SHOWN. MOTOR - HORSE POWER IDENTIFIED AS SHOWN
OCCUPANCY SENSOR 2P, 3W GROUNDING TYPE RECEPTACLE - 125V, CONVENTIONAL DUPLEX AND FLOOR CLEANING TYPE OUTLETS, NEMA 5-20A SERIES "GFI" ADJACENT TO SYMBOL DESIGNATES GROUND FAULT INTERRUPTER. "IG" DESIGNATOR INDICATES ISOLATED GROUND RECEPTACLE. LOCATE 18" AFF, UNLESS NOTED OTHERWISE. (2) 2P, 3W GROUNDING TYPE RECEPTACLE - 125V, DOUBLE DUPLEX TYPE OUTLETS, (2) NEMA 5-20A, IN 4-SQUARE BOX FLOOR DUPLEX RECEPTACLE OUTLET 2P, 3W GROUNDING TYPE SIMPLEX CLOCK RECEPTACLE - 125V OUTLETS, NEMA 5-20A SERIES, "GFCI" ADJACENT TO SYMBOL DESIGNATES GROUND FAULT CIRCUIT INTERRUPTOR. 3P, 4W GROUNDING TYPE SPECIAL RECEPTACLE - 125/250V OUTLETS, NEMA 14-30R SERIES. LOCATE AS NOTED. ELECTRICAL PANELBOARD. TELEPHONE TERMINAL BOARD (PLYWOOD BACKBOARD). DATA OUTLET, DUPLEX, 18" AFF, UNLESS NOTED OTHERWISE. TELEPHONE OUTLET, 18" AFF, UNLESS NOTED OTHERWISE. DATA OUTLET, 18" AFF, UNLESS NOTED OTHERWISE. "2" DENOTES DUPLEX JACK. DATA OUTLET, MOUNTED IN RECESSED FLOOR BOX
Ckd by:
JRO
FD/SD
Contract No:
So
Rev.
Dwn by:
SCW
SCW
FL
MOTOR STARTER, TYPE AND SIZE AS INDICATED IN SCHEDULE. MOTOR STARTER FURNISHED WITH EQUIPMENT COMBINATION STARTER W/EXTERNALLY OPERATED DISCONNECT, FURNISHED WITH EQUIPMENT COMBINATION STARTER W/ EXTERNALLY OPERATED DISCONNECT.
VFD
MH RI RT MM CM
2 2
MODULAR TELEPHONE/DATA JACKS, 18" AFF, UNLESS NOTED OTHERWISE (2-TELEPHONE, 2-DATA). CATV OUTLET, 18" AFF, UNLESS NOTED OTHERWISE. "2" DENOTES DUPLEX JACK.
1
X1
KEYED NOTES EQUIPMENT CONNECTION, REFER TO APPROPRIATE SCHEDULE FOR ADDITIONAL INFORMATION.
CARD READER BALANCED MAGNETIC SWITCH, DOOR PROXIMITY READER STRIKE RELEASE DOOR HARDWARE IP ADDRESSABLE SECURITY CAMERA, CHARACTER DENOTES CAMERA CALLOUT.
1 1 FL XX
FLOOR MTD. TELEPH0NE/DATA JACKS (1-TELEPHONE, 1-DATA). TELEPH0NE AND DATA CABLES (x = NUMBER OF CABLES). ROUTED TO A JUNCTION BOX FOR MODULAR FURNITURE. RECESSED JUNCTION BOX WITH BLANK FACE PLATE FOR MODULAR FURNITURE, 18" AFF
NOTES:
1. 2.
SR
FOR GENERAL NOTES AND NON-ELECTRICAL SYMBOLS, SEE LEGEND. ALSO REFER TO ABBREVIATIONS SHEET. LETTERS SUCH AS ''WP'', ''GFI'' ADJACENT TO ANY SYMBOL INDICATE SPECIAL CONSTRUCTION IS REQUIRED. SEE ABBREVIATIONS FOR DEFINITIONS. SIZES OF WIRE AND CABLE ARE BASED ON COPPER CONDUCTORS. ALUMINUM CONDUCTOR IS NOT ACCEPTABLE. UNLESS OTHERWISE NOTED, ALL DIMENSIONS ARE IN INCHES. ELEVATIONS FOR ELECTRICAL EQUIPMENT ARE SHOWN TO CENTER OF DEVICE OR ENCLOSURE UNLESS NOTED OTHERWISE. RECEPTACLES AND TELE/DATA JACKS SHALL BE LOCATED 18" AFF UNLESS NOTED OTHERWISE. LIGHT SWITCHES SHALL BE LOCATED 48" AFF UNLESS NOTED OTHERWISE. NOT ALL SYMBOLS USED ON THIS PROJECT. RECEPTACLE PLATE AND SWITCH PLATES SHALL BE STAINLESS STEEL.
M HJ ES
MICROPHONE HEADSET JACK ELECTRIC STRIKE MAGNETIC LOCK DOOR CONTROLLER POWER TRANSFER DEVICE LOCK SWITCH UNLOCK SWITCH PUSH BAR DOOR HARDWARE
S L OR
3.
S
L MI V SPSIJ
4.
COL O
SPEAKER WITH ALARM LIGHT MICROPHONE INPUT PLATE, 18" AFF. WALL MOUNTED VOLUME CONTROL, 48" AFF. SPEAKER OUTPUT SPEAKER INPUT JUNCTION BOX, 4" SQUARE UNLESS NOTED OTHERWISE ADA DOOR OPERATOR PUSHBUTTON
G E OR
ML DC PTD LS US PB
5.
6.
SSMR SYM TEL TMGB TVSS TYP UG UNO V VA VFD VT W W/ W/O WP XMFR
STANDING SEAM METAL ROOF SYMMETRICAL TELEPHONE TELEPHONE MASTER GROUND BUS TRANSIENT VOLTAGE SURGE SUPPRESSION TYPICAL UNDERGROUND UNLESS NOTED OTHERWISE VOLT VOLT AMPERE VARIABLE FREQUENCY DRIVE REG I DO VOLTAGE TRANSFORMER S RA E V E R T S WEST E WITH 29554 WITHOUT WEATHERPROOF TRANSFORMER SS G
G
T
RA
I ON
N AL E
7. 8.
THE SEAL APPEARING ON THIS DOCUMENT WAS AUTHORIZED BY GEORGE E. VERSTRATE P.E. 29554 ON 11/12/09
IN
EE
X CP
CONTROL POINT FOR FURNITURE DATA/COMM RUNS. "X" DENOTES NUMBER OF CONNECTIONS.
Contr No.
E-001
MIN N NEC N, NEUT N.O. N\C N.C. NSMR OCPD PA PNL PH PVC RECP REF REQD RGS S SEC SPEC SPKR
MINIMUM NORTH NATIONAL ELECTRICAL CODE NEUTRAL NORMALLY OPEN NO CONNECTION NORMALLY CLOSED NON-STRUCTURAL METAL ROOF OVER CURRENT PROTECTIVE DEVICE PUBLIC ADDRESS PANEL PHASE POLYVINYL CHLORIDE RECEPTACLE REFERENCE REQUIRED RIGID GALVANIZED STEEL SOUTH SECONDARY SPECIFICATIONS SPEAKER
CONSULTING ENGINEERS 6243 I.H. 10 W., SUITE 200 SAN ANTONIO, TEXAS 78201-2022 FAX 210-736-9258 PH 210-736-6623
TS
FS
JRO
Designed by:
DD
dB dBA DIM DISC DWG E ELEC EMCS EMT ENCL EPO EQ EQUIP EXIST EXP EXT FACP FE GFGI GFI G, GND, GRD GOVT HPF IMC IG J-BOX KAIC KV KVA KW KWH LFMC
DECIBEL DECIBEL, A-WEIGHTED DIMENSION DISCONNECT DRAWING EAST ELECTRICAL OR ELECTRIC ENERGY MANAGEMENT CONTROL SYSTEM ELECTRICAL METALLIC TUBING ENCLOSURE EMERGENCY POWER OFF EQUAL EQUIPMENT EXISTING EXPOSED EXTERIOR FIRE ALARM CONTROL PANEL FURNISHED WITH EQUIPMENT GOVERNMENT FURNISHED, GOVERNMENT INSTALLED GROUND FAULT INTERRUPTER GROUND GOVERNMENT HIGH POWER FACTOR INTERMEDIATE METAL CONDUIT ISOLATED GROUND JUNCTION BOX KILOAMPS INTERRUPTING CAPACITY (SYM RMS) KILOVOLTS KILOVOLT AMPERES KILOWATT KILOWATT HOURS LIQUIDTIGHT FLEXIBLE METAL CONDUIT
sio n
MOLDED CASE CIRCUIT BREAKER, FIXED TRIP. THREE POLE UNLESS DESIGNATED '1P' OR '2P'
Ae
RECESSED INCANDESCENT OR H.I.D. LUMINAIRE, UPPER CASE LETTER IDENTIFIES FIXTURE TYPE.
Di r
ELECTRICAL ABBREVIATIONS
A, AMP ACCP AF AFF AIC ASYM AT ATS AWG BLDG BP/IS C CATV CB CKT C L COMM CONT Cu AMPERE ALARM CENTER CONTROL PANEL AMPS FRAME ABOVE FINISH FLOOR AMPS INTERRUPTING CAPACITY (SYM RMS) ASYMMETRICAL AMPS TRIP AUTOMATIC TRANSFER SWITCH AMERICAN WIRE GAGE BUILDING BYPASS/ISOLATION CONDUIT COMMUNITY ANTENNA TELEVISION CIRCUIT BREAKER CIRCUIT CENTER LINE COMMUNICATION CONTINUOUS COPPER
ks or
DPW
FORT HOOD
TEXAS
Submitted by:
Reviewed by:
DESIGN FILE:
g En
ED ER T E
P RO
FE