Sei sulla pagina 1di 6

IES INDOOR REPORT

PHOTOMETRIC FILENAME : 267941.IES


DESCRIPTION INFORMATION (From Photometric File)
IESNA:LM-63-2002
[TEST] 26794
[DATE] 05/14/2007
[LUMCAT] AVS2CF18-SPMW-1/2-EB
[LUMINAIRE] DAY-BRITE 1' ARIOSO SPLIT BASKET SURFACE SCONCE
[MORE](TESTED HORZ) (MODIFIED)
[LAMP] F18BX
[BALLAST] TRIAD CT218UNVSE
[MANUFAC] PHILIPS DAY-BRITE
[TESTLAB] PHILIPS DAY-BRITE PHOTOMETRIC LABORATORY, TUPELO, MS
[MORE] NVLAP LABORATORY CODE 200016-0
[ISSUEDATE] 6/13/2007
[_TEST_LEVEL]
[_TIFF_FILE_NAME]
[_VERSION] fo2ies 3.0d(0-180)
[OTHER] Reflection factor 0.92, Test distance = 26 ft.
CHARACTERISTICS
Lumens Per Lamp
Total Lamp Lumens
Luminaire Lumens
Total Luminaire Efficiency
Luminaire Efficacy Rating (LER)
Total Luminaire Watts
Ballast Factor
CIE Type
Spacing Criterion (0-180)
Spacing Criterion (90-270)
Spacing Criterion (Diagonal)
Basic Luminous Shape
Luminous Length (0-180)
Luminous Width (90-270)
Luminous Height

1200 (2 lamps)
2400
1538
64 %
36
42
0.98
General Diffuse
N.A.
N.A.
N.A.
Rectangular w/Sides
1.00 ft
0.81 ft
0.21 ft

Photometric Toolbox Professional Edition - Copyright 2002-2011 by Lighting Analysts, Inc.


Calculations based on published IES Methods and recommendations, values rounded for display purposes.
Results derived from content of manufacturers photometric file.

Page 1

IES INDOOR REPORT


PHOTOMETRIC FILENAME : 267941.IES
LUMINANCE DATA (cd/sq.m)
Angle In
Degrees

Average
0-Deg

Average
45-Deg

Average
90-Deg

45
55
65
75
85

1394
1992
2836
3827
6154

733
974
1286
1723
2363

939
811
586
314
116

Photometric Toolbox Professional Edition - Copyright 2002-2011 by Lighting Analysts, Inc.


Calculations based on published IES Methods and recommendations, values rounded for display purposes.
Results derived from content of manufacturers photometric file.

Page 2

IES INDOOR REPORT


PHOTOMETRIC FILENAME : 267941.IES
CANDELA TABULATION

0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
95
100
105
110
115
120
125
130
135
140
145
150
155
160
165
170
175
180

0.0
95
76
57
41
43
49
55
64
76
90
99
112
124
131
133
133
135
137
135
132
130
130
129
118
109
95
85
71
62
53
46
40
51
64
76
85
87

22.5
95
75
57
44
43
47
53
61
71
82
91
102
115
120
120
120
121
123
122
120
118
120
117
107
97
90
76
67
57
51
45
40
52
72
77
82
87

45.0
95
83
69
55
43
40
40
44
48
52
55
62
64
70
76
75
72
74
72
71
75
76
70
64
61
54
51
46
43
40
39
49
60
67
74
81
87

67.5
95
90
81
71
62
52
41
32
31
31
28
33
29
28
28
29
28
26
28
29
28
28
26
25
25
25
28
31
40
54
66
78
81
82
87
79
87

90.0
95
99
97
95
91
88
86
77
71
63
55
48
38
29
20
12
6
3
2
3
5
11
21
29
40
45
55
71
82
89
91
93
95
94
96
98
87

112.5
95
107
117
127
137
144
146
151
154
139
127
112
102
97
98
98
90
81
76
78
86
99
102
102
109
114
123
138
152
150
147
137
123
113
105
90
87

135.0
95
115
137
160
176
194
186
183
176
181
189
197
213
219
212
201
189
186
186
189
191
196
205
216
227
229
219
208
198
192
189
192
179
167
141
109
87

157.5
95
113
143
170
191
190
186
197
216
237
260
278
286
278
271
265
261
262
266
267
268
266
268
271
282
289
291
277
259
236
221
210
205
190
148
114
87

Photometric Toolbox Professional Edition - Copyright 2002-2011 by Lighting Analysts, Inc.


Calculations based on published IES Methods and recommendations, values rounded for display purposes.
Results derived from content of manufacturers photometric file.

180.0
95
110
154
182
198
200
199
213
236
255
277
298
299
291
284
277
275
277
281
282
282
279
281
283
292
298
300
291
261
247
220
214
204
201
180
107
87

Page 3

IES INDOOR REPORT


PHOTOMETRIC FILENAME : 267941.IES
ZONAL LUMEN SUMMARY
Zone

Lumens

%Lamp

%Fixt

0-30
0-40
0-60
0-90
90-120
90-130
90-150
90-180
0-180

89.46
159.32
367.82
762.17
390.42
507.11
681.17
776.22
1538.38

3.70
6.60
15.30
31.80
16.30
21.10
28.40
32.30
64.10

5.80
10.40
23.90
49.50
25.40
33.00
44.30
50.50
100.00

Total Luminaire Efficiency = 64.10%


ZONAL LUMEN SUMMARY
Zone

Lumens

0-10
10-20
20-30
30-40
40-50
50-60
60-70
70-80
80-90
90-100
100-110
110-120
120-130
130-140
140-150
150-160
160-170
170-180

9.37
29.64
50.45
69.86
92.79
115.72
130.14
132.73
131.47
131.78
131.96
126.68
116.69
98.45
75.61
53.61
32.11
9.34

Photometric Toolbox Professional Edition - Copyright 2002-2011 by Lighting Analysts, Inc.


Calculations based on published IES Methods and recommendations, values rounded for display purposes.
Results derived from content of manufacturers photometric file.

Page 4

IES INDOOR REPORT


PHOTOMETRIC FILENAME : 267941.IES
COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHOD
Effective Floor Cavity Reflectance 0.20
RC
RW

80
70 50 30 10

70
70 50 30 10

50
50 30 10

30
50 30 10

10
50 30 10

0
0

0
1
2
3
4
5
6
7
8
9
10

69
60
53
48
44
40
36
34
31
29
27

63
55
49
44
40
36
33
30
28
26
24

53
43
36
31
27
24
21
19
17
16
14

44
35
29
25
21
19
17
15
14
13
12

36
27
22
19
16
15
13
12
11
10
9

32
21
16
12
9
8
6
6
5
4
4

69
56
47
41
35
31
28
25
22
20
19

69
52
42
35
29
25
22
19
17
15
14

69
49
38
30
25
21
18
15
13
12
10

63
51
43
37
32
29
25
23
21
19
17

63
48
39
32
27
23
20
18
16
14
13

63
45
35
28
23
19
16
14
12
11
10

53
40
32
27
23
19
17
15
13
12
11

53
38
29
23
19
16
14
12
10
9
8

44
33
26
22
18
16
14
12
11
10
9

44
31
24
19
16
13
11
10
8
7
7

36
26
20
17
14
12
10
9
8
7
7

Photometric Toolbox Professional Edition - Copyright 2002-2011 by Lighting Analysts, Inc.


Calculations based on published IES Methods and recommendations, values rounded for display purposes.
Results derived from content of manufacturers photometric file.

36
25
19
15
12
10
8
7
6
6
5

Page 5

IES INDOOR REPORT


PHOTOMETRIC FILENAME : 267941.IES
POLAR GRAPH

300

225

150

75
2

Maximum Candela = 300 Located At Horizontal Angle = 180, Vertical Angle = 130
# 1 - Vertical Plane Through Horizontal Angles (180 - 0) (Through Max. Cd.)
# 2 - Horizontal Cone Through Vertical Angle (130) (Through Max. Cd.)

Photometric Toolbox Professional Edition - Copyright 2002-2011 by Lighting Analysts, Inc.


Calculations based on published IES Methods and recommendations, values rounded for display purposes.
Results derived from content of manufacturers photometric file.

Page 6

Potrebbero piacerti anche