Sei sulla pagina 1di 16

Actuator Selection Guide

Technical Bulletin No. 1005


Date: July 2010 / Pg. 1 of 16

A Subsidiary of BRAY INTERNATIONAL, Inc.

ACTUATOR SELECTION GUIDE FOR FLOW-TEK BALL VALVES


Proper actuator selection is needed to ensure consistent operation of the automated valve. Selecting the proper actuator begins with
establishing valve operating torque. Valve operating torque is determined by seating material, operation frequency, media type and
line pressure. This guide provides a means of determining the valve operating torque based on these variables.

The following steps are used to select the proper actuator:

1. After selecting the desired seating material, refer to the charts on the following pages to determine the basic torque requirement for the valve.
2. Using the design or maximum operating line pressure and the valve size chose the Valve Torque Requirement from the
tables. If line pressure is not listed the next highest pressure nearest the actual pressure should be selected.
3. Determine the Application Factor from the chart below. Select the largest factor if the service appliction matches more than
one of the listed factors.
4. Determine the Frequency of Operation Factor from the chart below.
5. Add the Application Factor and the Frequency of Operation Factor to determine the Total Torque Factor.
6. Multiply the torque from the tables per item 2 by the Total Torque Factor per item 5 to determine the Total Valve Torque
Requirement. This will be the torque needed to size the actuator.
7. From the actuator output torque tables select an actuator with an output torque greater than the Valve Torque Requirement.

Pneumatic Actuators

Electric Actuators

Double Acting (Air-to-Air): Determine the air supply pressure available to the actuator and select the Actuator Size that
exceeds the Valve Torque Requirement.
Single Acting (Spring Return for fail safe operation, either Fail-Open or Fail-Close): Determine the air supply available to
the actuator and select the Actuator Size that exceeds the Valve Torque Requirement for the END of stroke for BOTH the
Air Stroke and the Spring Stroke. The actuator selection is optimized when the end of stroke torques are nearly equal.

Select the Actuator Size that exceeds the Valve Torque Requirement.
8. From the EZ Ordering Code Matrix select the mounting kit required to connect the valve and actuator. EZ Ordering Codes
are listed by valve series.
Note: Safety factors are not built into the Valve Torque Requirements.
Examples of how to size an actuator can be found on page 6 of this Technical Bulletin.

APPLICATION FACTORS
Media
Clean Particle-Free, Non-Lubricating (water)
Lubricating Fluid (clean oil)
Fluids with Solid Particles
Chilled Water
Condensed Water
River Water
Low Temperature 0F to -150F
Cryogenic Service from -150F to -425F
Chlorine Service
Lubricant Free or Oxygen Cleaned

Factor
1.0
1.0
1.4
1.3
1.4
1.4
1.3
2.0
1.5
1.5

Media

Factor

Saturated Steam
Superheated Steam
Clean Natural and Other Gasses
Slurries
Dry Powders
Modulating with Positioners
Series 70 Electric On / Off
Cavity Filler Added
Triad Series 3 Piece
Multiport Valves - See Multiport Torque Tables

1.3
1.5
1.3
1.8
1.8
1.3
1.2
1.3
1.15

Factors listed above are to be used as a guide only. Actual conditions may vary causing an increase or decrease in the Application Factor.

FREQUENCY OF OPERATION FACTORS


Frequency

Factor

One or More Cycles Per Day


Less Than One Cycle Per Week
Less Than One Cycle Per Month
Less Than One Cycle Per Six Months

0.0
0.3
0.4
0.5

Total Torque Factor = Application Factor + Frequency of Operation Factor


Total Valve Torque Requirement = Valve Torque Requirement x Total Torque Factor
If a Media Containment Unit is added between the valve and the actuator additional torque must be added to the valve operating torque as follows:

MCU 1 .....20 lb-ins


MCU 3T ...50 lb-ins

MCU 2 .....30 lb-ins


MCU 4 .....60 lb-ins

MCU 3 .....40 lb-ins


MCU 5 .....70 lb-ins

50
85
120
155
250
360
450
550
1050
2400
4600
12500
18500

1/4
1/2
3/4
1
1 1/4
1 1/2
2
2 1/2
3
4
6
8
10
12

50
85
120
160
250
370
480
610
1300
2850
5000
12800
19000

100

50
87
130
165
265
390
520
665
1550
3300
5400
13200
19500

200

50
87
130
165
270
400
560
720
1800
3700
5800
13500
20000

300

52
87
130
180
275
420
585
770
2100
4150
6200
14700
22000

400

35
65
85
140
210
355
375
500
900
2000
3000
11300
16600

1/4
1/2
3/4
1
1 1/4
1 1/2
2
2 1/2
3
4
6
8
10
12

35
65
90
145
215
370
400
500
1100
2400
3600
12200
17600

100

35
65
90
150
225
380
450
600
1350
2850
4200
13000
18700

200

36
65
95
155
230
390
500
650
1505
3250
4750
13700
19700

300

130
210
280
390
510

VALVE
SIZE

1/2
3/4
1
1 1/5
2

40
68
100
165
250
410
505
700
1950
4000
5850
15400
21400

40
69
105
170
255
425
505
750
2200
4450
6450
16200
22500

150
240
320
440
590

160
260
360
500
660

180
280
400
550
740

200
310
440
610
810

220
330
480
660
890

230
350
520
710
960

TORQUE, LB-IN - FULL PORT - MULTI-COMPONENT METAL SEATS


LINE PRESSURE, PSI
100
200
300
400
500
600

40
65
100
160
240
400
500
680
1750
3625
5325
14800
20600

400

55
90
135
180
290
450
660
875
2600
5000
7100
18100
26000

55
90
135
185
295
465
700
930
2850
5400
7400
19000
28000

58
90
135
185
300
480
730
990
3100
5700
7800
19400
28400

60
92
140
190
310
495
765
1045
3350

60
95
140
195
315
510
800
1100
3600

250
370
560
770
1040

700

40
70
108
172
265
435
590
810
2400
4825
7000
1700
23400

260
380
570
790
1060

740

40
70
110
175
270
445
600
850
2600
5300
7600
17800
24500

42
70
112
180
280
455
610
900
2800

45
70
120
195
305
490
698
1035
3442

1200

60
95
145
200
325
530
872
1206
4122

1200

47
70
125
205
320
510
750
1125
3865

1400

60
95
150
205
340
540
942
1315
4635

1400

47
70
130
215
330
530
802
1216
4289

1600

60
98
150
215
350
550
1013
1424
5147

1600

49
72
140
225
350
550
854
1307
4712

1800

65
100
155
235
365
635
1083
1533
5660

1800

50
75
145
245
360
575
905
1398
5136

2000

65
100
160
255
385
665
1153
1642
6173

2000

51
75
150
265
375
600
957
1488
5559

2200

65
105
165
275
400
690
1224
1751
6685

2200

2. For Triad Series Valves multiply listed torque by 1.15.

Notes: 1. For Standard Port valves use torque for the next smaller size valve.
Example: 1 Standard Port = 3/4 Full Port,

1 Full Port = 1-1/4 Standard Port

42
70
115
185
285
465
650
950
3000

TORQUE, LB-IN - FULL PORT - TEK-FIL,PTFE OR TFM SEATS


LINE PRESSURE, PSI
500
600
700
800
900
1000

55
90
135
180
280
435
625
820
2300
4550
6650
16900
24000

500

TORQUE, LB-IN - FULL PORT - RPTFE SEATS


LINE PRESSURE, PSI
600
700
800
900
1000

2-PC METAL SEATS - FULL PORT VALVES

VALVE
SIZE

TEK-FIL, TFM OR PTFE SEATS - FULL PORT VALVES

VALVE
SIZE

RPTFE SEATS - FULL PORT VALVES

VALVE TORQUE REQUIREMENTS 2 WAY VALVES


A Subsidiary of BRAY INTERNATIONAL, Inc.

Actuator Selection Guide


Technical Bulletin No. 1005
Date: July 2010 / Pg. 2 of 16

50
100
150
225
350
500
750
1250
1800
3000
6000

50
105
155
232
360
550
850
1350
2000
3500
6500

100

51
107
160
240
370
650
1000
1500
2300
4000
7000

200

55
110
165
250
385
700
1100
1650
2600
4500
7400

300

56
112
170
260
395
750
1200
1750
2900
4900
7900

400

82
140
180
220
335
350
800
1350
2100
4600
8260
22440
33210

1/4
1/2
3/4
1
1 1/4
1 1/2
2
2 1/2
3
4
6
8
10
12

85
145
185
225
345
450
950
1500
2400
5000
8980
22980
34110

100

85
145
190
230
360
550
1000
1700
2650
5400
9690
23700
35010

200

90
150
195
240
375
650
1150
1850
2900
5900
10410
24240
35910

300

90
150
200
245
385
700
1250
2000
3200
6300
11130
26390
39500

400

58
118
178
270
420
850
1450
2000
3400
5900
8800

95
160
200
250
400
850
1400
2200
3500
6750
11940
30340
43090

2. For Triad Series Valves multiply listed torque by 1.15.

60
120
180
280
430
950
1500
2200
3750
6400
9250

60
125
185
290
440
1000
1600
2300
3950

60
130
190
295
450
1100
1700
2350
4250

61
135
195
305
465
1200
1800
2500
4500

95
160
210
260
410
900
1500
2300
3800
7200
12750
32500
46680

100
165
212
265
425
1000
1600
2500
4000
7600
13290
34110
50270

100
165
215
270
435
1100
1700
2600
4200
7800
13700
35600
53700

100
170
220
280
450
1200

105
175
225
285
460
1300

TORQUE, LB-IN - FULL PORT - PEEK OR DELRIN SEATS


LINE PRESSURE, PSI
500
600
700
800
900
1000

57
115
172
265
410
780
1300
1850
3200
5450
8400

TORQUE, LB-IN - FULL PORT - UHMWPE OR 50/50 SEATS


LINE PRESSURE, PSI
500
600
700
800
900
1000

110
180
230
290
490
1500

1200

62
140
200
320
485
1300

1200

115
185
235
310
515
1650

1400

65
142
205
340
510
1400

1400

120
190
240
330
540
1850

1600

70
150
225
355
530
1500

1600

130
195
255
340
565
2000

1800

71
155
230
370
555
1700

1800

140
200
260
350
590
2200

2000

75
160
240
380
580
1750

2000

145
210
270
365
615
2400

2200

76
165
250
400
600
1850

2200

Notes: 1. For Standard Port valves use torque for the next smaller size valve.
Example: 1 Standard Port = 3/4 Full Port,

1 Full Port = 1-1/4 Standard Port

VALVE
SIZE

PEEK OR DELRIN SEATS - FULL PORT VALVES

1/4
1/2
3/4
1
1 1/4
1 1/2
2
2 1/2
3
4
6
8
10
12

VALVE
SIZE

UHMWPE OR 50/50 SEATS - FULL PORT VALVES

VALVE TORQUE REQUIREMENTS 2 WAY VALVES

A Subsidiary of BRAY INTERNATIONAL, Inc.

Actuator Selection Guide


Technical Bulletin No. 1005
Date: July 2010 / Pg. 3 of 16

Actuator Selection Guide


Technical Bulletin No. 1005
Date: July 2010 / Pg. 4 of 16

A Subsidiary of BRAY INTERNATIONAL, Inc.

VALVE TORQUE REQUIREMENTS


MULTIPORT VALVES
FULL PORT VALVES - PTFE OR TFM 1600 SEATS
VALVE
SIZE

1/4 & 3/8


1/2
3/4
1
1 1/4
1 1/2
2
2 1/2
3
4
6
8

71
106
133
221
248
372
496
938
1062
2301
3480
5265

MULTIPORT VALVE TORQUE, IN-LB - FULL PORT - PTFE SEATS


LINE PRESSURE, PSI
100
200
300
400
500
600
700

800

1000

75
108
136
231
265
390
545
976
1206
2367
3800
5600

102
122
156
291
364
495
836
1201
2069
2766
5700
7600

106
124
159
301
381
513
885
1239
2213
2832
6000
8000

115
128
166
321

MULTIPORT VALVE TORQUE, IN-LB - STANDARD PORT - PTFE SEATS


LINE PRESSURE, PSI
100
200
300
400
500
600
700

800

1000

106
124
159
301
381
513

115
128
166
321

80
111
140
241
281
407
593
1013
1350
2434
4100
5950

84
113
143
251
298
425
642
1051
1494
2500
4450
6300

89
115
146
261
315
443
691
1089
1638
2567
4700
6600

93
117
149
271
331
460
739
1126
1781
2633
5050
6950

97
120
153
281
348
478
788
1164
1925
2699
5370
7300

STANDARD PORT VALVES - PTFE OR TFM 1600 SEATS


VALVE
SIZE

1/4 & 3/8


3/4
1
1 1/4
1 1/2
2

71
106
133
221
248
372

Notes:




75
108
136
231
265
390

80
111
140
241
281
407

84
113
143
251
298
425

89
115
146
261
315
443

93
117
149
271
331
460

97
120
153
281
348
478

102
122
156
291
364
495

Above torque values are based on PTFE or TFM 1600 seats in clear, non-viscous fluid.
For RPTFE Seats multiply listed torque by 1.15.
For Tek-Fil Seats multiply listed torque by 1.00.
For 50/50 Seats multiply listed torque by 1.50.
For UHMWPE Seats multiply listed torque by 1.62.
When using the torque table for sizing actuators use the Application Factors listed on page 1.

TYPICAL VALVE TORQUE CURVE

Break Torque
Ending Torque
Run Torque

Start

End

Note: Ball valve torque is high at the beginning of each stroke, called Break Torque.
This high initial torque is the result of the ball and seats taking a set after sitting in a
static position for a period of time. As the ball is turned the torque decreases. This is
known as the Run Torque. The torque will again increase at the end of the stroke as
the ball and seats are returned to full contact. This torque is known as Ending Torque
and it will be approximately 80% of the Break Torque. This typical curve occurs in
both directions when operating a ball valve open to closed or closed to open.

Actuator Selection Guide


Technical Bulletin No. 1005
Date: July 2010 / Pg. 5 of 16

A Subsidiary of BRAY INTERNATIONAL, Inc.

DOUBLE ACTING PNEUMATIC OPERATED


TORQUE OUTPUT (LB.-INS.)

AUTOMATOR SERIES
DOUBLE ACTING
TORQUE CURVE
End

Start

The Double Acting Actuator


has a constant output
torque throughout travel
from start to end, clockwise or counterclockwise
rotation.

SINGLE ACTING
TORQUE CURVES
Start

Air Supply Pressure (PSIG)

Actuator
Size

40

60

80

100

120

48
63
83
93
119
128
160
210
255

75
145
351
493
1058
1410
2797
5783
14211

113
221
536
753
1615
2152
4270
8826
21691

150
297
721
1013
2171
2894
5742
11870
29171

188
373
906
1272
2728
3636
7214
14914
36650

225
449
1091
1532
3285
4378
8687
17957
44130

End
Counterclockwise (Air Stroke)
Start

End
Clockwise (Spring Stroke)

SPRING RETURN PNEUMATIC OPERATED TORQUE OUTPUT (LB.-INS.)


No.
Air Supply Pressure (PSIG)
Actuator Springs
40
60
80
100
120
Size
Per
Piston Start End Start End Start End Start End Start End
48

63

83

93

119

128

160

210

255

1
2/1
2
3/2
3
2
3
4
5
6
2
3
4
5
6
2
3
4
5
6
2
3
4
5
6
2
3
4
5
6
2
3
4
5
6
2
3
4
5
6
2
3
4
5
6

51
39

32
10

89
77
64
52

70
48
27
5

91
64

65
27

167
140
113
86

141
103
65
27

210
156

167
76

395
341
281
220

352
261
176
97

310
218

232
101

570
478
386
294

492
361
231
94

692
509

469
174

1249
1066
883
700

1026
731
437
142

880

465

1622
1357
1094

1207
733
261

1819
1399

1118
349

3292
2872
2452
2030

2591
1822
1123
353

3833
2859

2508
868

6876
5902
4930
3949

5551
3911
2275
638

9487
7125

6747
3015

16967
14605
12243
9880

14227
10495
6762
3030

126
114
101
89
77
243
216
189
162
135
580
526
466
405
369
830
738
646
554
462
1805
1622
1439
1256
1073
2364
2099
1836
1568
1302
4764
4344
3924
3502
3154
9920
8946
7974
6993
6022
24447
22085
19723
17360
14998

107
85
64
42
21
217
179
141
103
65
537
446
361
282
185
752
621
491
354
229
1582
1287
993
698
404
1949
1475
1003
529
57
4063
3294
2595
1825
1196
8595
6955
5319
3682
2031
21707
17975
14242
10510
6778

164
152
139
127
115
319
292
265
238
211
765
711
651
590
554
1089
997
905
813
721
2362
2179
1996
1813
1630
3106
2841
2578
2310
2044
6236
5816
5396
4974
4626
12964
11990
11018
10037
9066
31926
29564
27202
24839
22477

145
123
102
80
59
293
255
217
179
141
722
631
546
467
370
1011
880
750
613
488
2139
1844
1550
1255
961
2691
2217
1745
1271
799
5535
4766
4067
3297
2668
11639
9999
8363
6726
5075
29186
25454
21721
17989
14257

201
189
176
164
152
395
368
341
314
287
950
896
836
775
739
1349
1257
1165
1073
981
2919
2736
2553
2370
2187
3848
3583
3320
3052
2786
7709
7289
6869
6447
6099
16007
15033
14061
13080
12109
39406
37044
34682
32319
29957

182
160
139
117
96
369
331
293
255
217
907
816
731
652
555
1271
1140
1010
873
748
2696
2401
2107
1812
1518
3433
2959
2487
2013
1541
7008
6239
5540
4770
4141
14682
13042
11406
9769
8118
36666
32934
29201
25469
21737

Spring Stroke
Start

End

43
65
86
108
129
80
118
156
194
232
184
275
360
439
536
261
392
522
659
784
589
884
1178
1473
1767
945
1419
1891
2365
2837
1679
2448
3147
3917
4546
3275
4915
6551
8188
9839
7464
11196
14929
18661
22393

24
36
49
61
73
54
81
108
135
162
141
195
255
316
352
183
275
367
459
551
366
549
732
915
1098
530
795
1058
1326
1592
978
1398
1818
2240
2588
1950
2924
3896
4877
5848
4724
7086
9448
11811
14173

For Spring Return Actuators select the size where End of Air and End of Spring both exceed the Valve Torque Requirement

Actuator Selection Guide


Technical Bulletin No. 1005
Date: July 2010 / Pg. 6 of 16

A Subsidiary of BRAY INTERNATIONAL, Inc.

SERIES 73
ELECTRIC ACTUATOR TORQUES
Actuator
Size
S73-1
S73-3
S73-6

SERIES 70 PREMIER
ELECTRIC ACTUATOR TORQUES

Torque Output
lb.-ins.
100
300
600

Actuator
Size
S70-003
S70-005
S70-008
S70-012
S70-020
S70-030
S70-050
S70-065

Torque Output
lb.-ins.
300
500
800
1200
2000
3000
5000
6500

ELECTRIC ACTUATOR
TORQUE CURVE
Start

End

Electric Actuators have


a constant output torque
throughout travel from
start to end, clock-wise or
counter-clock-wise rotation.

EXAMPLES OF HOW TO SIZE AN ACTUATOR


Select Flow-Tek Double Acting (Air-to-Air) pneumatic actuator, Single Acting (Spring Return) pneumatic actuator and a
Flow-Tek Electric Actuator for the following application:
Valve: 2 F15, Full Port Line Pressure: 200 psi Line Media: Saturated Steam Seat Material: Tek-Fil
Actuator Air Supply Pressure: 80 psig Frequency of operation: 4 times per day.

Step 1 Determine The Torque Requirement

Refer to the Valve Torque Requirements chart for a Tek-Fil seat. A 2 valve with line pressure of 200 psi has a torque
requirement of 380 lb.-ins. The application is for Saturated Steam so use an Application Factor of 1.3. The frequency
of operation is 4 times per day so use a factor of 0.0. The total torque factor is 1.3 (1.3 + 0.0 = 1.3).
Valve Torque Requirement: 380 x 1.3 = 494 lb.-ins.

Step 2 Select the Correct Actuator Size

Double Acting Pneumatic Actuator, with Air Supply pressure of 80 psig


From the Double Acting Pneumatic Operated Output chart select the size actuator that exceeds 494 lb.-ins. with an
80 psig air supply. The size 83 actuator has a torque output of 721 lb.-ins. The next size smaller actuator (size 63)
only has a torque output of 297.
Correct Actuator: Size 83
Spring Return Pneumatic Actuator, with Air Supply pressure of 80 psig - Same valve as above.
From the Spring Return Pneumatic Operated Output chart select the size actuator that exceeds 494 lb.-ins. with an 80
psig air supply. FOR SPRING RETURN THE ENDING OF THE AIR STROKE AND THE SPRING STROKE MUST EXCEED
THE VALVE TORQUE REQUIREMENT OF 494 LB.-INS. The first actuator to accomplish this is the size 119 with 3 springs
(air end 1287, spring stroke 549). The next size actuator is a 119 with 4 springs (air end 993, spring end 732). The
end stroke of torque on a 119-4 is more balanced and it allows for changes in service conditions.
Correct Actuator: Size 119-4
Electric Actuator
The Application Factors for Series 70 ON/OFF is 1.2. Valve Torque Requirement: 494 x 1.2 = 592.8 lb.-ins.
From the Electric Actuator Torque Output charts select the size actuator that exceeds 592.8 lb.-ins.
Correct Actuator: Size S73-6 (torque output of 600 lb.-ins.)

or
Correct Actuator: Size S70-008 (torque output of 800 lb.-ins.)

Step 3 Select the Mounting Kit to Connect the Valve and Actuator
Refer to the EZ Ordering Code Matrix for 2 F15, Full Port valve.
Pneumatic Double Acting:
Pneumatic Spring Return:
Electric:

2
2
2
2

F15
F15
F15
F15

valve
valve
valve
valve

with
with
with
with

size
size
size
size

083 actuator requires EZ-005S.


119-4 actuator requires EZ-010S.
S73-6 actuator requires EZ-004S.
S70-008 actuator requires EZ-005S.

Actuator Selection Guide


Technical Bulletin No. 1005
Date: July 2010 / Pg. 7 of 16

A Subsidiary of BRAY INTERNATIONAL, Inc.

ISO MOUNTING KIT - EZ CODE MATRIX S DRIVE


TRIAD SERIES VALVES
Type
S.P.

F.P.

1
1
1
2
2

3/8

1
1
1
2
3
4

ACTUATOR SIZE / MODEL

Electric
Pneumatic

S70-003
S70-005
S73-1, S73-3, S73-6
B048
B063

S70-008
S70-012
S70-020
B083
B093

EZ-002S

EZ-003S

EZ-004S

EZ-005S

EZ-050S
(73 Series Only)

EZ-006S

B119

S70-030
S70-050
S70-065
B128

EZ-007S

B160

B210

B255B

EZ-013S
EZ-015S

EZ-074S

B210

B255B

EZ-056S

EZ-012S
Contact Factory

7000/8000 SERIES VALVES


Type
F.P.

Electric
Pneumatic

3/8

1
1-
1-
2
2
3
4
6
8

ACTUATOR SIZE / MODEL


S70-003
S70-005
S73-1, S73-3, S73-6
B048
B063

S70-008
S70-012
S70-020
B083
B093

EZ-002S

EZ-003S

EZ-008S

EZ-009S

EZ-004S

EZ-005S

EZ-010S

EZ-018S
EZ-011S

EZ-019S

B119

S70-030
S70-050
S70-065
B128
B160

EZ-012S

Note: EZ CODE is not an actuator sizing guide. Size the actuator for the proper torque of the valve.

EZ-013S
EZ-014S

EZ-015S

Actuator Selection Guide


Technical Bulletin No. 1005
Date: July 2010 / Pg. 8 of 16

A Subsidiary of BRAY INTERNATIONAL, Inc.

ISO MOUNTING KIT - EZ CODE MATRIX S DRIVE


F15/30 SERIES VALVES
Type
F.P.

Electric
Pneumatic

ACTUATOR SIZE / MODEL


S70-003
S70-005
S73-1, S73-3, S73-6
B048
B063

S70-008
S70-012
S70-020
B083
B093

EZ-002S

EZ-003S

EZ-008S

EZ-009S

EZ-021S

EZ-060S

EZ-004S

EZ-005S

EZ-010S

EZ-059S

1
1
2
2
3
4
6
8
10
12

B119

S70-030
S70-050
S70-065
B128
B160

B210

B255B

EZ-011S
EZ-012S
EZ-013S
EZ-014S

EZ-015S

EZ-074S

EZ-040S

EZ-030S

B210

B255B

RF15 SERIES VALVES


Type

ACTUATOR SIZE / MODEL


S70-003
S70-005
S73-1, S73-3, S73-6
B048
B063

S70-008
S70-012
S70-020
B083
B093

EZ-002S

EZ-003S

1
2
3
4
6
8
10
12

EZ-003S
EZ-004S

EZ-009S
EZ-005S

F.P.

Electric
Pneumatic

EZ-024S

B119

S70-030
S70-050
S70-065
B128
B160

EZ-025S

Note: EZ CODE is not an actuator sizing guide. Size the actuator for the proper torque of the valve.

EZ-026S
EZ-014S

EZ-015S

EZ-074S

EZ-040S

EZ-030S

Actuator Selection Guide


Technical Bulletin No. 1005
Date: July 2010 / Pg. 9 of 16

A Subsidiary of BRAY INTERNATIONAL, Inc.

ISO MOUNTING KIT - EZ CODE MATRIX S DRIVE


S7000 (S7500/S7700) SERIES VALVES
Type
OD Tube Port

ACTUATOR SIZE / MODEL

Electric
Pneumatic

S70-003, S70-005
S73-1, S73-3, S73-6
B048
B063

S70-008, S70-012
S70-020
B083
B093

EZ-002S

EZ-003S

EZ-008S

EZ-009S

EZ-021S

EZ-004S

EZ-005S

EZ-010S

1
1
2

S70-030, S70-050
S70-065
B119
B128
B160

S70 / S90 SERIES VALVES


Type
S.P.

ACTUATOR SIZE / MODEL


S70-003, S70-005
S73-1, S73-3, S73-6
B048
B063

Electric
Pneumatic

1
1
2

S70-008, S70-012, S70-020


B083

B093

EZ-002S

EZ-003S

EZ-031S
EZ-004S

EZ-032S
EZ-005S

S85 SERIES VALVES


Type
F.P.

Electric
Pneumatic

ACTUATOR SIZE / MODEL


S70-003, S70-005
S73-1, S73-3, S73-6
B048

1
1
1
2
2
3

B063

S70-008, S70-012
S70-020
B083

B093

S70-030, S70-050
S70-065
B119

B128

B160

EZ-002S
EZ-008S

EZ-009S

EZ-004S

EZ-005S

EZ-010S

EZ-006S
EZ-018S

EZ-007S
EZ-019S

MPT130 / MPC 130 SERIES VALVES


Type
MPT Size

MPC Size

Electric
Pneumatic

1
1
1
2

1
1
2

ACTUATOR SIZE / MODEL


S70-003, S70-005
S73-1, S73-3, S73-6
B048
B063
EZ-034S

S70-008, S70-012
S70-020
B083
B093

S70-030, S70-050
S70-065
B119
B128
B160

EZ-035S

EZ-036S

EZ-037S

EZ-048S

EZ-038S

Note: EZ CODE is not an actuator sizing guide. Size the actuator for the proper torque of the valve.

EZ-039S

Actuator Selection Guide


Technical Bulletin No. 1005
Date: July 2010 / Pg. 10 of 16

A Subsidiary of BRAY INTERNATIONAL, Inc.

ISO MOUNTING KIT - EZ CODE MATRIX S DRIVE


MPT230 / MPC 230 SERIES VALVES
Type
MPT 230
Size

MPC
230
Size

1
1
1
2
2
3
4

1
1
2
2
3
4

Electric
Pneumatic

ACTUATOR SIZE / MODEL


S70-003
S70-005
S73-1, S73-3, S73-6
B048
B063
EZ-034S

S70-008
S70-012
S70-020
B083
B093

EZ-036S

EZ-037S

S70-030
S70-050
S70-065
B119 B128 B160

EZ-041S
EZ-038S
EZ-042S

EZ-048S

B210

B255B

EZ-039S
EZ-043S

EZ-044S

EZ-045S
EZ-046S

MPF150/300 SERIES VALVES


Type
F.P.

Electric
Pneumatic

1
1
2
2
3
4
6
8

ACTUATOR SIZE / MODEL


S70-003
S70-005
S73-1, S73-3, S73-6
B048
B063
EZ-034S

S70-008
S70-012
S70-020
B083
B093

EZ-036S

EZ-037S

EZ-048S

EZ-038S
EZ-042S
EZ-044S

B119

S70-030
S70-050
S70-065
B128
B160

B210

B255B

EZ-039S
EZ-043S
EZ-045S

*8 Available in MPF 150 only.


Note: EZ CODE is not an actuator sizing guide. Size the actuator for the proper torque of the valve.

EZ-046S
EZ-047S

EZ-073S

EZ-075S

Actuator Selection Guide


Technical Bulletin No. 1005
Date: July 2010 / Pg. 11 of 16

A Subsidiary of BRAY INTERNATIONAL, Inc.

ISO MOUNTING KIT - EZ GEAR CODE MATRIX S DRIVE


TRIAD SERIES VALVES
GEAR SIZE / MODEL
S.P.

1
1
1
2
2
-

F.P.

3/8

1
1
1
2
3
4

FTG22

FTG30

FTG50

FTG80

EZ-003S
EZ-005S
EZ-006S

EZ-007S

EZ-020S

EZ-012S
EZ-014S

EZ-015S

7000/8000 SERIES VALVES


GEAR SIZE / MODEL
F.P.
, 3/8,

1
1-
1-
2
2
3
4
6
8

FTG22

FTG30

FTG50

EZ-003S
EZ-009S
EZ-005S
EZ-006S
EZ-020S

EZ-012S
EZ-014S

Note: EZ CODE is not an gear sizing guide. Size the gear for the proper torque of the valve.

EZ-015S

FTG80

Actuator Selection Guide


Technical Bulletin No. 1005
Date: July 2010 / Pg. 12 of 16

A Subsidiary of BRAY INTERNATIONAL, Inc.

ISO MOUNTING KIT - EZ GEAR CODE MATRIX S DRIVE


F15/30 SERIES VALVES
GEAR SIZE / MODEL
F.P.

1
1
1
2
2
3
4
6
8
10
12

FTG22

FTG30

FTG50

FTG80

EZ-003S
EZ-009S
EZ-005S

EZ-010S

EZ-011S

EZ-012S

EZ-013S

EZ-014S

EZ-015S
EZ-030S

RF15 SERIES VALVES


GEAR SIZE / MODEL
S.P.

1
1-
2
3
4
6
8
10
12

FTG22

FTG30

FTG50

EZ-014S

EZ-015S

FTG80

EZ-003S
EZ-009S
EZ-003S
EZ-026S

Note: EZ CODE is not an gear sizing guide. Size the gear for the proper torque of the valve.

EZ-030S

Actuator Selection Guide


Technical Bulletin No. 1005
Date: July 2010 / Pg. 13 of 16

A Subsidiary of BRAY INTERNATIONAL, Inc.

ISO MOUNTING KIT - EZ GEAR CODE MATRIX S DRIVE


S7000 (S7500/S7700) SERIES VALVES
GEAR SIZE / MODEL
OD Tube Port

1
1
2

FTG22

FTG30

FTG50

FTG80

EZ-003S
EZ-009S
EZ-005S

S70 / S90 SERIES VALVES


GEAR SIZE / MODEL
S.P.

1
1-
2
2
3

FTG22
EZ-003S
EZ-009S

FTG30

FTG50

FTG80

EZ-005S
EZ-006S

S85 SERIES VALVES


GEAR SIZE / MODEL
F.P.

1
1-
1-
2
2
3

FTG22

FTG30

FTG50

FTG80

EZ-003S
EZ-009S
EZ-005S
EZ-006S
EZ-018S

EZ-019S

MPT130 / MPC 130 SERIES VALVES


GEAR SIZE / MODEL
MPT
Size
-

1
1
1
2

MPC
Size

1
1
2

FTG22

FTG30

EZ-035S
EZ-037S
EZ-038S

EZ-039S

Note: EZ CODE is not an gear sizing guide. Size the gear for the proper torque of the valve.

FTG50

FTG80

Actuator Selection Guide


Technical Bulletin No. 1005
Date: July 2010 / Pg. 14 of 16

A Subsidiary of BRAY INTERNATIONAL, Inc.

ISO MOUNTING KIT - EZ GEAR CODE MATRIX S DRIVE


MPT230 / MPC230 SERIES VALVES
GEAR SIZE / MODEL
MPT230
Size
-

1
1
1
2
2
3
4

MPC230
Size

1
1
2
2
3
4

FTG22

FTG30

FTG50

FTG80

EZ-035S
EZ-037S
EZ-038S
EZ-042S

EZ-043S

EZ-044S

EZ-045S

EZ-046S

MPF150/300 SERIES VALVES


GEAR SIZE / MODEL
F.P.

FTG22

EZ-035S

FTG30

FTG50

EZ-037S

1-

EZ-038S

EZ-042S

EZ-043S

EZ-044S

EZ-045S

2
3

EZ-046S

4
6
8
Note: EZ CODE is not an gear sizing guide. Size the gear for the proper torque of the valve.

EZ-051S

FTG80

Actuator Selection Guide


Technical Bulletin No. 1005
Date: July 2010 / Pg. 15 of 16

A Subsidiary of BRAY INTERNATIONAL, Inc.

FLUSH MOUNTING KITS

Flow-Teks Flush Mounting Kits are available on valves sizes 1/4 to 2-1/2 and they provide a very attractive method of
connecting Flow-Tek valves and actuators. At 1.30 in height, these kits offer a low profile connection between the actuator and valve and reduce the overall space requirements of the assembly. The kits come complete with an investment cast
(CF8M) Flush Mount Housing, 304 Stainless Steel coupler and Stainless Steel hardware. In addition to the reduced space
requirements, these kits offer some additional advantages over standard mounting kits. They will protect the packing area of
the valve during caustic washdowns and the design offers full access to the mounting bolts for fast and easy actuator mounting. These kits can be mounted in any direction and feature a weep hole to eliminate the possibility of an internal buildup
of media. The kits also allow the user to field mount different size actuators to a single valve. All couplers are machined to
close tolerances. Flow-Tek is offering these low profile kits in addition to our standard mounting kits.

FLUSH MOUNTING KIT SELECTION CHART


Triad
SP

3/4
1

Valve Series and Size


7000/8000
F15/F30
S85*
FP

1/4
3/8
1/2
3/4

1/4
3/8
1/2
3/4

1/2
3/4

S7000

1/2
3/4
1

Pneumatic
Actuator

Electric
Actuator

FM Kit
Number

B048
B063

S73-1
S73-2
S73-3

FM-001

B083
B093
B048
B063

1
1 1/4

1 1/2

B083
B093
B119
B128
B063

1 1/4
1 1/2

1
1 1/4

1 1/2
2

1 1/2
2

B083
B093

FM-002
S73-1
S73-2
S73-3
S70-003
S70-005
S70-008
S70-012

2
2 1/2

1 1/2
2

2 1/2

B083
B093
B119
B128

*S85 is not available in 1/4 and 3/8 sizes.

FM-003

FM-004
FM-005

S73-6
S70-003
S70-005
S70-008
S70-012
S70-020

B119
B128
B063

In (mm)

FM-006
FM-007
FM-008

S73-6
S70-003
S70-005
S70-008
S70-012
S70-020

FM-009
FM-010
FM-011

1.30
(33)

A Subsidiary of BRAY INTERNATIONAL, Inc.

Actuator Selection Guide


Technical Bulletin No. 1005
Date: July 2010 / Pg. 16 of 16

CONVERSIONS

All statements, technical information, and


recommendations in this
bulletin are for general
use only. Consult FlowTek representatives or
factory for the specific
requirements and material selection for your
intended application.
The right to change or
modify product design
or product without prior
notice is reserved.

FLOW-TEK, Inc.
8323 N. Eldridge
Pkwy # 100 Houston,
Texas 77041
Tel: 832.912.2300
Fax: 832.912.2301
www.flow-tek.com
2010 Flow-Tek, Inc.