Sei sulla pagina 1di 2

Fan coils

MOP -M o
fo r h o r i z

Cooling capacity: 1.18.3 kW - Heating capacity: 1.511.7 kW

nt a

14

YARDY EV2

SIO N S ERcal installation V T r ti


d
ve

la

HORIZONTAL
installation

Enhanced performance Installation exibility Acoustic comfort 6-speed fan Preinstalled accessories and controls
Floor and ceiling fan coil units with cabinet.
Construction features
Heat exchanger with nned coil with left-hand connections reversible to right. 6-speed centrifugal fan, of which 3 speeds are connected to the terminal board. Covering cabinet structure made of pre-painted sheet metal complete with renewable lter, ABS polymer grilles and condensation drain pan with natural drainage.

VERTICAL

installation

Versions
MVP - Vertical unit with cabinet equipped with lower air inlet and upper outlet for wall mounting or with feet on ground. MVT - Vertical unit with cabinet equipped with front air inlet and upper outlet for oor installation. MOP - Horizontal/vertical unit with cabinet equipped with rear air inlet and front ow for ceiling installation, wall mounting or with feet on ground. MOT - Horizontal/vertical unit with cabinet equipped with lower air inlet and front outlet for ceiling of oor installation.

ACCESSORIES

Panel with room thermostat, summer/winter switch, speedswitch, ON/OFF valve signal and electric heater. Minimum temperature thermostat (for installation on themachine). Electronic panel with automatic summer/winter switch for 2-pipe systems. Electronic panel with automatic summer/winter switch and automatic speed regulation for 2-pipe systems with electric heater or 4-pipe systems. For installation on machine (MVP and MVT versions) Panel with speed switch. Panel with room thermostat, summer/winter switch and speedswitch. Minimum temperature thermostat. Panel with room thermostat, summer/winter switch, speedswitch, ON/OFF valve control and electric heater. Electronic panel with automatic summer/winter switch for 2-pipe systems. Electronic panel with automatic summer/winter switch and automatic speed regulation for 2-pipe systems with electric heater or 4-pipe systems. Interface board for controlling up to 4 fan coils.

Additional water heating coil. Electric heater. Valve and balancing valve. ON/OFF 2-way solenoid valves for 2 and 4 pipe systems. ON/OFF 3-way valves for 2 and 4-pipe systems. Auxiliary condensation drain pan. Manual damper. Motorised damper. Rear panel. Rear closure panel. Rear closure panel with grille and lter. Support feet with pipe cover.

CONTROLS

Wall-mounted remote control receiver with remote control. Electronic panel for wall or on board mounting. Wall-mounted recessed electronic panel.

For installation on machine

STANDARD CONTROLS For wall mounting installation

Master/slave electronic board. Temperature probe for hot row. Module for ON/OFF valves and electric heater management. Serial interfaces for connection to BMS (proprietary protocol, Modbus RTU). Serial converters (RS485/RS232, RS485/USB) in case of centralised unit management. Serial interface (CAN-bus - Controller Area Network) for the iDRHOSS system. Key: Factory-mounted Supplied loose

Panel with speed and summer/winter switch.

Web code: WVYE Web code accessories: WAWB

15

WATER CHILLERS HEAT PUMPS WATER CHILLERS HEAT PUMPS


RECEIVER

MOP for horizontal installation

MOT for horizontal installation

MVP-MOP for vertical installation

MVT-MOT for vertical installation

Data in the following conditions: Air: 27C D.B.; 19C W.B. - Water: 7/12C, data relative to the speed indicated of the 6 available. Air: 20C - Water: 50C; ow rate as in cooling, data relative to the speed indicated of the 6 available. Air: 20C - Water: 70/60C, data relative to the speed indicated of the 6 available. At 1 m from air outlet with directionality factor of 2, data relative to the speed indicated of the 6 available.

MVP-MOP+feet

TERMINAL UNITS

FAN COIL CONVECTORS SYSTEM ACCESSORIES

YARDY EV2 MOP-MOT-MVP-MVT MODEL Total cooling capacity MAX kW (Speed) MED kW (Speed) MIN kW (Speed) Heat capacity (50C) MAX kW (Speed) MED kW (Speed) MIN kW (Speed) Heat capacity (70C) MAX kW (Speed) Heat capacity MAX kW (Speed) additional coil MED kW (Speed) MIN kW (Speed) Air flow speed MAX m/h (Speed) MED m/h (Speed) MIN m/h (Speed) Sound capacity MAX dB(A) (Speed) MED dB(A) (Speed) MIN dB(A) (Speed) Sound pressure MAX dB(A) (Speed) MED dB(A) (Speed) MIN dB(A) (Speed) Maximum consumed power MAX W Power supply V-ph-Hz SIZES AND WEIGHTS L - Width mm H - Height mm Feet height mm P - Depth mm Weight Kg

15 1.07 (II) 0.91 (IV) 0.65 (VI) 1.48 (II) 1.25 (IV) 0.84 (VI) 2.54 (II) 1.41 (II) 1.19 (IV) 0.98 (VI) 209 (II) 163 (IV) 100 (VI) 43 (II) 35 (IV) 26 (VI) 35 (II) 27 (IV) 18 (VI) 32 (II) 230-1-50 15 700 570 100 220 16

20 1.80 (II) 1.39 (IV) 1.14 (VI) 2.31 (II) 1.74 (IV) 1.46 (VI) 3.93 (II) 2.16 (II) 1.72 (IV) 1.47 (VI) 288 (II) 207 (IV) 154 (VI) 44 (II) 35 (IV) 30 (VI) 36 (II) 27 (IV) 22 (VI) 30 (II) 230-1-50 20 800 570 100 220 20

22 2.02 (I) 1.56 (III) 1.20 (V) 2.65 (I) 2.33 (III) 1.64 (V) 4.50 (I) 2.07 (I) 1.74 (III) 1.44 (V) 339 (I) 238 (III) 177 (V) 48 (I) 40 (III) 34 (V) 40 (I) 32 (III) 26 (V) 38 (I) 230-1-50 22 800 570 100 220 20

25 2.54 (I) 2.05 (III) 1.64 (V) 3.47 (I) 2.71 (III) 2.18 (V) 5.94 (I) 3.01 (I) 2.55 (III) 2.06 (V) 484 (I) 338 (III) 252 (V) 48 (I) 38 (III) 30 (V) 40 (I) 30 (III) 22 (V) 45 (I) 230-1-50 25 1.000 570 100 220 20

30 2.85 (II) 2.49 (IV) 1.80 (VI) 3.85 (II) 3.14 (IV) 2.37 (VI) 6.60 (II) 2.99 (II) 2.55 (IV) 2.15 (VI) 483 (II) 383 (IV) 281 (VI) 47 (II) 40 (IV) 34 (VI) 39 (II) 32 (IV) 26 (VI) 54 (II) 230-1-50 30 1.000 570 100 220 21

40 3.42 (II) 2.66 (IV) 2.09 (VI) 4.45 (II) 3.50 (IV) 2.93 (VI) 7.58 (II) 3.40 (II) 3.24 (IV) 3.02 (VI) 587 (II) 419 (IV) 364 (VI) 48 (II) 40 (IV) 35 (VI) 40 (II) 32 (IV) 27 (VI) 58 (II) 230-1-50 40 1.200 570 100 220 27

45 4.33 (I) 3.35 (III) 2.52 (VI) 5.51 (I) 4.11 (III) 3.08 (VI) 9.30 (I) 3.91 (I) 3.40 (III) 2.54 (VI) 680 (I) 473 (III) 338 (VI) 52 (I) 43 (III) 35 (VI) 44 (I) 35 (III) 27 (VI) 70 (I) 230-1-50 45 1.200 570 100 220 28

55 5.49 (I) 4.48 (III) 3.39 (V) 7.17 (I) 5.74 (III) 4.22 (V) 12.21 (I) 6.08 (I) 5.13 (III) 4.02 (V) 1,077 (I) 802 (III) 537 (V) 58 (I) 52 (III) 41 (V) 50 (I) 44 (III) 33 (V) 115 (I) 230-1-50 55 1.500 570 100 220 35

60 80 6.69 (I) 8.32 (I) 5.54 (III) 6.90(IV) 4.31(VI) 6.36(VI) 8.78 (I) 11.67 (I) 7.25 (III) 9.99(IV) 5.52(VI) 9.04(VI) 14.95 (I) 20.11 (I) 6.29 (I) 7.46 (I) 5.77 (III) 6.80(IV) 4.68(VI) 6.17(VI) 1,234 (I) 1,480 (I) 947 (III) 1,171(IV) 672(VI) 994(VI) 62 (I) 66 (I) 56 (III) 61(IV) 48(VI) 57(VI) 54 (I) 58 (I) 48 (III) 53(IV) 40(VI) 49(VI) 161 (I) 184 (I) 230-1-50 230-1-50 60 80 1.500 1.500 570 570 100 100 220 220 35 37

CONDENSING UNITS

EXP Polyvalent systems

INDUSTRIAL & PROCESS COOLING

WATER-cooled CONDENSERLESS UNITS

WATER CHILLERS HEAT PUMPS

AIR-cooled CENTRIFUGAL fans

AIR-cooled AXIAL fans

Potrebbero piacerti anche