Sei sulla pagina 1di 13

TOSHIBA V 726B 1 U-View Limited

<Specified input and output levels, and 2-1. Servo Circuit 1. During playback press the VTR’s channel up Address Data
impedance> and down buttons simultaneously to reset to 24 0A
General Information Video input: Negative sync, standard composite tracking center. 25 03
video signal 1 V(p-p), 75Ω 2. Confirm that phase difference between the 26 15
Video output: Same as the video input 1 V(p-p), fall of the DFF pulse (pin 1 of BW005) and the
Also Covers 75Ω rise of CTL pulse (pin 2 of BW005) is 12 ± 0.5
27 0A

V 727B Audio input: 308 mV(rms), more than 47 kΩ


(phono type), more than 10 kΩ (21 pin type)
ins.
3. Further, observe the envelope (pin 4 of
5. Perform the adjustment described in the item
“2-1-1. Playback Phase (PG) Adjustment”.
Audio output: 308 mV(rms), less than 4.7 kΩ BW005) waveform, and confirm that the ACE 6. Pull out the power cord plug from the AC
(phono type), less than 1.0 kΩ (21 pin type) head position adjustment and linearity outlet once and insert the power cord plug
adjustment have been made, and C-SYNC into the AC outlet again.
Matrix <Alignment sequence> (pin 70 of IT001) is being input during 7. Perform the channel presetting as the IT004
Item See Model Book Recorded the alignments in the sequence as playback. replaced has no channel data.
shown in Fig. 2-1-2. 4. Set the VTR to the STOP mode.
2-2. Audio Circuit
Deck Alignment ............................................................................ Toshiba V 856 6
Mech. Adjustments ...................................................................... Toshiba V 856 6
Deck Exploded View .................................................................... Toshiba V 856 6

Main PC Board

Recommended Safety Parts


Item Part No. Description
(V726B Only)

0001C 70061668 Owners Manual English


0014C 70012604 Power Cord Terminal PC Board
0250 70051776 Front Panel
0350 70051141 Bottom Plate
2-1-1. Playback Phase (PG) Adjustment
0400 70051620 Top Cover
0450 70975305 Label
Fig. 2-1-2
RS045 70041671 Res, Fusible 18 Ω J 0.3W Test point: 5. Press the unit’s channel up/down buttons Main PC Board
RT809 70040122 Res, Carbon 1Ω J 0.3W Alignment tape specifications Pins 1 and 2 of BW005, Pin 19 of BX102 (Video simultaneously for more than 5s.
RW012 70041074 Res, Fusible 27 Ω J 0.3W out) 6. Afterwards, within 2s, press the PLAY button 2-2-1. Bias Level Adjustment
RW021 70041672 Res, Fusible 5.6 Ω J 0.3W [1] ST-C6 Test equipment: Oscilloscope on the remote controller.
RW030 70041116 Res, Fusible 39 Ω J 0.3W 7. The automatic adjustment will be made for Test point: Pins 1 and 2 of BS001
LP002 70011949 Line Filter Test equipment: Millivoltmeter
about 10s, all the displays will blink. If the
LP020 70012427 Power Transformer TF-SMT13
automatic adjustment is not carried out, Adjusting point: PS034
CP001 70042150 Cap, Plastic 100nF M
CP003 70051665 Cap 2.2nF 400V confirm that the alignment tape has a safety
RP018 70041078 Res, Fusible 1.5 Ω J 0.3W tab or not, and redo from the step 3. 1. Set the VTR to record mode.
RP021 70041673 Res, Fusible 2.2k Ω J 0.3W 2. Connect pin 2 to the millivoltmeter and pin 1
RP071 70041073 Res, Fusible 22 Ω J 0.3W 1) When adjustment has been completed: to ground.
RP091 70042136 Res, Fuse 0.47 Ω K The display will blink for 10s, stop blinking 3. Adjust PS034 to obtain 3.6 (300µA) ± 0.1 mV
RP092 70040125 47 Ω J 0.3W and return to the normal display in the STILL (rms).
BP 001 70011176 Inlet
mode, then it shifts to the playback display in
FP001 70010445 Fuse, 1A, 250V
the playback mode. 2-3. Self Diagnosis Function
(V727B Only) 2) When adjustment fails:
It goes into the STOP mode. 2-3-1. Outline
0001C 70061922 Owners Manual English
0014C 70012731 Power Cord 8. Confirm that the play indicator is displayed, When a tape running stops or the VTR enters
0250 70052001 Front Panel and confirm that the rising and falling edge of the power OFF mode, etc. due to some
0350 70051141 Bottom Plate the SW pulse is 6.5 ± 0.5H from the V-sync abnormality, the abnormality is stored in the
0400 70051620 Top Cover EEPROM and displayed on the display tube.
front edge of the video signal.
RS045 70041671 Res, Fusible 18 Ω J 0.3W
RT809 70040122 Res, Carbon 1Ω J 0.3W
RW012 70041074 Res, Fusible 27 Ω J 0.3W 2-1-2. When lT004 is Replaced 2-3-2. Storing abnormal modes
RW021 70040122 Res, Carbon 1Ω J 0.3W
RW030 70041116 Res, Fusible 39 Ω J 0.3W When IT004 is replaced, the data in the VTR is • The abnormality is classed into 5 groups, and
LP002 70011949 Line Filter [2] ST-C7 required to memorize in the new one. So the abnormality number, system control
LP020 70012427 Power Transformer TF-SMT13 perform the following procedures. mode, and the mechanism position at which
CP001 70042150 Cap, Plastic 100nF M the abnormality occurred are stored in the
CP003 70051665 Cap 2.2nF 400V EEPROM.
1. Press the channel up/down buttons on the
RP018 70041078 Res, Fusible 1.5 Ω J 0.3W
VTR simultaneously for more than 5s while • The writing timing is just after the abnormality
RP021 70041673 Res, Fusible 2.2k Ω J 0.3W
the display blinks and the unit is in the power occurred.
off mode.
11. Color pattern generator 2. And then within 2s, press the CANCEL button 2-3-3. Abnormality mode display
Electrical Adjustments 12. Video sweep generator on the remote controller.
3. After displaying the address at the channel • Press the CH UP and CH DOWN buttons on
<Test equipment required> <Color bar signal> display area and the data at the minute the VTR simultaneously for more than 5s.
Adjustment will be performed with the following Color bar signals of 75% recorded on the display area, set the address to 12 using the • And then within 2s, press the STILL button on
test equipment. alignment tapes are shown in Fig. 2-1-1. channel up/down buttons on the remote the remote control.
controller. Next, set the data to d2 using the • The system control mode at which the
1. Color TV (Monitor) FF/REW buttons on the remote controller. abnormality occurred is displayed at the
2. Oscilloscope, 2 CHs, 15 MHz or higher with The data goes up using FF button and down channel display area, “E” is displayed at the
delay system using REW button. hour digit, abnormality generation number is
3. Frequency counter (7 digits or higher) displayed at the minute digit, and the
4. Millivoltmeter mechanism position is displayed in the
5. Digital voltmenter second digit position.
6. Tester(20kΩ/V) • The abnormality mode is displayed regardless
7. Audio generator of the power on off.
8. Audio attenuator
9. Alignment tapes
Part code: ST-C6: 70909409, ST-C7: 4. Set each address and data in the table
70909410 following the description above.
10. Alignment screw driver (jig) Fig. 2-1-1
TOSHIBA V 726B 2 www.u-view.co.uk
(3) Example of display
Electrical Adjustments
Cont’d • In case of 1234 hours.

• In case of 4 hours.
Scart AV Switching Diagram

• When the Counter Reset button is pressed in Electrical Adjustments


the display period, the abnormality display
data is initialized and “-” is displayed. (V-727B Only)
The data displayed are as follows: 1. ADJUSTMENT PROCEDURES

Abnormality generation number 1-1. Servo Circuit

1-1-1. When IT004 is Replaced


When IT004 is replaced, the data in the VTR is
required to memorize in the new one. So
perform the following procedures.

1. Press the channel up/down buttons on the


Abnormal system control modes VTR simultaneously for more than 5s while
the display blinks and the unit is in the power
off mode.
2. And then within 2s, press the CANCEL button
on the remote controller.
3. After displaying the address at the channel
display area and the data at the minute
display area, set the address to 12 using the
channel up/down buttons on the remote
controller. Next, set the data to d2 using the
FF/REW buttons on the remote controller. The
data goes up using FF button and down using
REW button.

Fig. 1-1
Abnormal mechanism positions
4. Set each address and data in the table
following the description above.

Table 1-1

Address Data
24 0A
25 03
26 15
27 0A
28 5A
Positions 0, 2, 4 exist as mechanism positions. 0C 7F
For example, 8 shows a position between 7 and
9 (between playback position and review 5. Perform the adjustment described in the item
position). “Playback Phase (PG) Adjustment”.
6. Pull out the power cord plug from the AC
2-3-4. Cylinder rotation time display outlet once and insert the power cord plug
(1) Outline into the AC outlet again.
All the time for which the cylinder is ON is 7. Perform the channel presetting as the IT004
counted, memorized on EEPROM, and indi- replaced has no channel data.
cated on the display tube.

(2) Display method


• Press the “CH UP” and “CH DOWN” button on
the main unit for more 5 sec. at the same
time.
• Next, within 2 sec. press the “STOP” button
on the remote control.
• The cumulative operation time of the cylinder
will be displayed for 30 sec. The time unit is
an hour.
TOSHIBA V 726B 3 U-View Limited
Wiring Diagram Wiring Diagram (V 727B)
TOSHIBA V 726B 4 www.u-view.co.uk

IF Tuner (V726B) Diagram


TOSHIBA V 726B 5 U-View Limited

IF Tuner (V 727B) Diagram


TOSHIBA V 726B 6 www.u-view.co.uk

Keyboard Front Panel (V 726B) Diagram


TOSHIBA V 726B 7 U-View Limited

Keyboard Front Panel (V 727B) Diagram


TOSHIBA V 726B 8 www.u-view.co.uk

Power Supply Diagram


TOSHIBA V 726B 9 U-View Limited

Audio Diagram
TOSHIBA V 726B 10 www.u-view.co.uk

Servo Logic (V 726B) Diagram


TOSHIBA V 726B 11 U-View Limited

Servo Logic (V 727B) Diagram


TOSHIBA V 726B 12 www.u-view.co.uk

Video (V 726B) Diagram


TOSHIBA V 726B 13 U-View Limited

Video (V-727B) Diagram

Potrebbero piacerti anche