Documenti di Didattica
Documenti di Professioni
Documenti di Cultura
for AutoCAD
LISEGA SE
V 9.3.0
V 9.3.0
Contents
System requirements .............................................................................................................................. 1 Available versions of the LISEGA plug-ins ............................................................................................... 1 Installation ............................................................................................................................................... 1 Configuration via XML files...................................................................................................................... 2 LicadPlugInCommonSettings.XML ....................................................................................................... 2 LicadPlugInUserSettings.XML .............................................................................................................. 2 Loading (Starting) the Plug-ins ................................................................................................................ 2 Insertion of LISEGA supports ................................................................................................................... 4 Variant 1: ............................................................................................................................................. 4 Configurations available ................................................................................................................ 10 Variant 2: Import of L3D files ............................................................................................................ 12 Deleting supports .................................................................................................................................. 13 Commands available ............................................................................................................................. 13 LISET .................................................................................................................................................. 13 LIDB.................................................................................................................................................... 15 LIPART ................................................................................................................................................ 15 LICAD, LICAD1, LICAD2, LICAD3, LICAD4, LICAD5 & LICADMOD ....................................................... 15 L3DIMP bzw. -L3DIMP ....................................................................................................................... 15 REG .................................................................................................................................................... 16 UNREG ............................................................................................................................................... 16 Attachment............................................................................................................................................ 17 LICAD Creation of a support ........................................................................................................... 17 LICAD Export of a support as an L3D file ....................................................................................... 21 AutoCAD menu extension, tool box and ribbon for plug-in .............................................................. 23 AutoCAD tool palette for the plug-in ................................................................................................ 26 Add tool palette............................................................................................................................. 26 Use of the plug-in in the network ..................................................................................................... 30 Adaptation of the local intranet zone ........................................................................................... 30 Altering zone allocation................................................................................................................. 31 Index ...................................................................................................................................................... 35
LISEGA SE
19.02.2013
V 9.3.0
System requirements
Windows XP or higher NET Framework 3.5 (2.0), 4.0 since AutoCAD 2013 AutoCAD from Version 2006 for Licad4Acad LICAD Version 9.3 (Instructions on downloading and installation can be found in the attachment)
The 32-bit as well as the 64-bit versions of AutoCAD / AutoCAD Plant 3D are supported. IMPORTANT: The above requirements must be fulfilled, above all with regard to LICAD!
Installation
Unpack the ZIP file and read the documentation contained in it before installation. This manual and a possibly ReadMe file are located directly in the ZIP file, so that the information is already available before installation. For the actual installation start the installation program from the relevant directory for the 32 or 64 bit version. For the 64 bit version of AutoCAD you must start the 64 bit version. For the 32 bit version of AutoCAD, start the 32 bit version. After starting the installation program follow the instructions there. The following directories are used by the installation program as standard: Windows 7: AutoCAD Plug-ins and manual: Database file: Windows XP: AutoCAD Plug-ins and manual: Database file: C:\Programs\LISEGA\Licad4Acad C:\Documents and settings\All Users\ Application data\Licad4Acad\db C:\Program Files\LISEGA\Licad4Acad C:\ProgramData\LISEGA\Licad4Acad\db
LISEGA SE
19.02.2013
V 9.3.0
LicadPlugInCommonSettings.XML
Directory in Win 7: C:\ProgramData\LISEGA\
<?xml version="1.0" encoding="utf-8"?> <ClsLicad4AcadGlobalXmlConfig xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:xsd="http://www.w3.org/2001/XMLSchema"> <DatabaseName>D:\LICAD V 2010 AutoCAD Plant 3D (LICAD4Plant3D)\Licad4Plant3D\db\SQLlite\Lisega3Dcatalog_db.s3db</DatabaseName> <DatabasePassword /> <DbEngineType>SQLite</DbEngineType> <DBserver /> </ClsLicad4AcadGlobalXmlConfig>
LicadPlugInUserSettings.XML
Directory in Win 7: C:\Users\<Account>\AppData\Roaming\LISEGA\Licad4Plant3D_V18
<?xml version="1.0" encoding="utf-8"?> <ClsLicad4AcadUserXmlConfig xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:xsd="http://www.w3.org/2001/XMLSchema"> <ChangeToModelSpace>false</ChangeToModelSpace> <CurrL3Dpath>C:\Users\nm\AppData\Local\Temp\</CurrL3Dpath> <CurrLang>en-GB</CurrLang> <ExportPath>C:\Users\nm\AppData\Local\Temp\</ExportPath> <HangermarkFontHeight>122</HangermarkFontHeight> <HangermarkVisible>false</HangermarkVisible> <Layer_Hangermark>0</Layer_Hangermark> <Layer_Support>0</Layer_Support> <LoggingEnabled>true</LoggingEnabled> <PartAsBlock>true</PartAsBlock> <Show_Hangermark>false</Show_Hangermark> <SkipOverrideDialog>false</SkipOverrideDialog> <UseGroup>false</UseGroup> <ZoomToSupport>false</ZoomToSupport> </ClsLicad4AcadUserXmlConfig>
LICAD for AutoCAD Available Commands: L4A_.LISET, L4A_.LIDB, L4A_.LIPART, L4A_.L3DIMP, L4A_.L3DIMP, L4A_.LICAD, L4A_.LICAD1, L4A_.LICAD2, L4A_.LICAD3, L4A_.LICAD4, L4A_.LICAD5, L4A_.LICADMOD, L4A_.REG, L4A_.UNREG
V 9.3.0
If the protocol function of the plug-in in the configuration file LicadPlugInUserSettings.XML is activated, the following information dialog also appears on starting.
LISEGA SE
19.02.2013
V 9.3.0
The second possibility is the import of L3D files created with LICAD. The information contained in the L3D file is then transferred to corresponding 3D objects.
Variant 1:
Example of the command LICAD: An empty drawing file is used here to draw attention to the essential points. A support is to be placed between the two 3D crosses displayed here.
Configuration 1 is used. This can be carried out by the command LICAD and subsequent request for the configuration number or by the command LICAD1, which already has the number in the name.
LISEGA SE
19.02.2013
V 9.3.0
During the pipe center point input, the positioning of the clamp in the direction X or Y axis can be decided on. The specification is the X direction. The configuration can be changed as well (Keywords: 1, 2, 3, 4 or 5). Its also possible to define the pipe direction (Horizontal or vertical). The current configuration, clamp orientation and pipe direction cant be selected (see following image):
LISEGA SE
19.02.2013
V 9.3.0
After the entry of Y instead of a point the clamp is correspondingly displayed rotated by 90 (see the two following illustrations).
After confirmation of the entry the clamp rotates in the Y axis direction.
By entering the letter X, and following confirmation, the positioning of the clamps is again carried out in the direction of the X axis. Now the pipe center point is determined here on the intercept of
LISEGA SE
19.02.2013
V 9.3.0
After that the upper attachment point of the support to the intercept of the lines of the upper star is determined.
After confirmation of the structural attachment point the LICAD program is automatically started. There the relevant data available (the configuration selected in LICAD is No. 13, the elevation numbers are entered) are already in the input fields.
LISEGA SE
19.02.2013
V 9.3.0
The missing data needed by LICAD for the design can now be simply supplemented.
On completion of all inputs, only the button at the bottom right with the green arrow now has to be pressed. LICAD then assembles the components required and supplies the information to the plug-in. The plug-in reads this information and generates from it the whole support out of the individual components composed from 3D bodies. The result of this example looks as follows: LISEGA SE 19.02.2013 8
V 9.3.0
LISEGA SE
19.02.2013
LICAD for AutoCAD Configurations available For the commands LICAD, LICAD1, LICAD2, LICAD3, LICAD4, LICAD5 & LICADMODthe following configurations are currently available. Configuration 1: (Simple suspension for horizontal pipes) Configuration 2: (Clamp base / pipe shoe for horizontal pipes)
V 9.3.0
LISEGA SE
19.02.2013
10
LICAD for AutoCAD Configuration 4 (for horizontal pipes): Configuration 4 (for vertical pipes):
V 9.3.0
LISEGA SE
19.02.2013
11
V 9.3.0
1. An open file dialog appears, in which files of the type LISEGA support information (*.L3D) can be selected.
Select a file and press the open button. 2. The plug-in reads the information from the L3D file and creates from it the 3D model of the support.
LISEGA SE
19.02.2013
12
V 9.3.0
Custom properties can be used to set the LICAD project directory. The name of the property must be LISEGA_LICAD_PRJ_DIR. The value of that property must define a complete directory
path like C:\Users\Public\Documents\LISEGA\LICAD 9.0 - Projects.
Deleting supports
The normal AutoCAD erase command has been expanded, so that while deleting a support LICAD is called in the background to delete the support in its database as well.
Commands available
The group denotations of the commands go as follows L4A_. for the AutoCAD plug-in. This way, ambiguities in the commands are avoided. The commands can be used without group denotations if only one plug-in (Licad4Acad or Licad4Plant3D) is loaded in each case. If both plug-ins have been simultaneously loaded the group denotation must be placed at the front so that the name is distinctly clear (e.g.: L4A_.LISET)
LISET
The settings for the plug-in can hereby be displayed and if necessary altered.
LISEGA SE
19.02.2013
13
V 9.3.0
LISEGA SE
19.02.2013
14
V 9.3.0
LIDB
With this the catalog database file can be selected. This is an SQLite database. The file is normally installed under [CommonAppDataFolder]LISEGA\Licad4Acad or. Licad4Plant3D\db. [CommonAppDataFolder] is a directory prescribed by Windows: Windows 7: Windows XP: C:\ProgramData\ C:\Documents and settings\All Users\Application data\
LIPART
With the aid of this command individual components from the LISEGA catalog can be inserted into the 3D model.
V 9.3.0
REG
With this command you register the plug-in for the so-called OnDemand Loading in AutoCAD. It is no longer necessary to load the plug-in manually first via the netload command; simply put in a command from the plug-in. AutoCAD then automatically loads the plug-in if it has not yet been loaded. This way, the commands are directly available, like normal AutoCAD commands.
UNREG
This command again deletes the registration for OnDemand Loading(see command REG).
LISEGA SE
19.02.2013
16
V 9.3.0
Attachment
LICAD Creation of a support
LISEGA SE
19.02.2013
17
V 9.3.0
Click on the
button.
Select a configuration, either with the navigation buttons or by entering desired configuration number.
LISEGA SE
19.02.2013
18
V 9.3.0
After that, click on one of the Differences or Notation buttons to define the spacing for the support.
Please enter this information in the entry fields shown and select, if required, further options on the right-hand side. Click once again on the button.
LISEGA SE
19.02.2013
19
V 9.3.0
button.
LISEGA SE
19.02.2013
20
V 9.3.0
LISEGA SE
19.02.2013
21
LICAD for AutoCAD And there select the entry Create L3D file.
V 9.3.0
Select, in the left-hand list of the saved supports, the ones you wish to export and then click on the button to place these in the list of the supports to be exported in the middle of the window. button.
Select the output directory in the right-hand area and then click on the The export starts and the following info dialog appears.
LISEGA SE
19.02.2013
22
V 9.3.0
LISEGA SE
19.02.2013
23
LICAD for AutoCAD Click on the Browse button. The dialog Select adaptation files appears.
V 9.3.0
Please change to the directory containing the file LICAD4plant3D.cuix. Select this file and click on the Open button. After that, you must still click on the previous dialog Load.
LISEGA SE
19.02.2013
24
LICAD for AutoCAD The file is loaded and displayed in the list of loaded adaptation files.
V 9.3.0
LISEGA SE
19.02.2013
25
V 9.3.0
Enter the command customize. Via the user screen this can also be achieved. This approach is adopted here:
Access the context menu of the toolbox palettes (click on the right-hand mouse button on a toolbox palette).
Make the menu entry Adapt palettes (click on the left-hand mouse button). After that, this adaptation dialog appears:
LISEGA SE
19.02.2013
26
V 9.3.0
There you once again access the context menu of the palette list (click on the right-hand button in the palette list)
Carry out the command Import (click on the entry with the left-hand mouse button).
LISEGA SE
19.02.2013
27
V 9.3.0
Switch there to the directory with the adaptation files and select the file LICAD for Plant 3D.xtp.
LISEGA SE
19.02.2013
28
V 9.3.0
LISEGA SE
19.02.2013
29
V 9.3.0
-url \\Server1\AutoCAD-AddOns\Licad4Acad\* These (* = all) files are to be given permission. FullTrust The security clearance to be granted (FullTrust is the highest level)
The program CasPol.exe is located in the bin directory of the respective .NET framework. There are up to four variants of the .NET framework. For the 32 bit versions the directories are named: .NET framework 2.0 (up to 3.5): c:\Windows\Microsoft.NET\Framework\v2.0.50727\ LISEGA SE 19.02.2013 30
V 9.3.0
For the 64 bit versions the directories are: .NET-Framework 2.0 (bis 3.5): .NET-Framework 4.0: NOTE: AutoCAD 2006 to 2012 uses the .NET framework 2.0 From 2013 AutoCAD uses the .NET framework 4.0 Depending on the version used and whether the 32 or 64 bit variant of AutoCAD is used, the respective CasPol version must be used, as these settings ALWAYS apply ONLY for the respective .NET framework! NOTE: If the netload command, as already mentioned above, still ends without a message, the computer on which the plug-in is to be used is, in all probability, not in the local intranet zone. In this case follow the instructions in the next section Alter zone allocation . Altering zone allocation The .NET framework has different security settings for the various network zones. Windows itself always allocates a zone to a computer. This happens automatically in the standard setting. Unfortunately, under certain circumstances in this automatic allocation it can come to incorrect allocations, so that a computer in the company network is not allocated to the local intranet zone, but to the internet zone (which of course has far fewer rights). In the previous section it was described how the security settings can be adapted for the local intranet zones. If your own computer is, however, not in the local intranet zone due to incorrect allocation, but in the internet zone, the alterations made have no effect, since they are restricted to the local intranet zone. It is still necessary to adapt the Windows internet options in the system control . Start the Windows system control and open the internet options. The following dialog window is displayed: c:\Windows\Microsoft.NET\Framework64\v2.0.50727\ c:\Windows\Microsoft.NET\Framework64\v4.0.30319\
LISEGA SE
19.02.2013
31
V 9.3.0
LISEGA SE
19.02.2013
32
LICAD for AutoCAD After that click on the symbol for the local intranet zone and then on the Sites button.
V 9.3.0
Deactivate the setting Define intranet automatically and activate the other three options: Include all local sites (Intranet) not listed in other zones Include all sites bypassing the proxy server Include all network paths (UNCs)
LISEGA SE
19.02.2013
33
V 9.3.0
Simply click on the OK button to accept the settings. You return to the previous window:
Here too, click on the OK button. The system control can now be closed.
LISEGA SE
19.02.2013
34
Index
_cuiload 23 _customize 26 local intranet zone 31 2006 1, 31 2007 1 2008 1 2009 1 2010 1, 2 2011 1, 2 2012 1, 2, 31 2013 1, 31 32Bit 30 64Bit 31 AutoCAD 1, 2, 13, 15, 16, 23, 26, 30, 31 CasPol.exe 30 configuration 7, 10, 11, 15, 18 Configuration 2, 4 individual components 15 internet zone 31 L3D file 21 L3D files 4 L3DIMP 3, 15 -L3DIMP Siehe L3DIMP L4A_ 13 LICAD i, 1, 2, 3, 4, 7, 8, 10, 15, 17, 21, 25, 28 LICADMOD 15 LicadPlugInCommonSettings.XML 2 LicadPlugInUserSettings.XML 2, 3 LIDB 3, 15 LIPART 3, 15 LISEGA 1, 2, 4, 12, 15 LISET 3, 13 local intranet zone 30 menu extension 23 NETLOAD 2 network 30 REG 3, 16 ribbon 23 system control 31, 34 system control 31 System requirements 1 tool box 23 tool palette 26 UNREG 3, 16 zone 31
LISEGA SE
19.02.2013
35