Sei sulla pagina 1di 29

www.abb.

com/fieldbus PROFIBUS PA / DP
Instruments

© 2007-06 V02 ABB Automation Products GmbH


3KXN630057R5801_Presentation_PROFIBUS_Instruments_PB57.ppt
PROFIBUS
Instruments
Contents

„ Overview

This session „ Flow Instruments (DP)


covers: „ Analyzers (DP)
„ Actuators (DP)
„ Remote I/Os (DP)
„ Positioners (PA)
„ Temperature transmitters (PA)
„ Pressure Transmitters (PA)
„ Multivariable Transmitters (PA)
„ Flow Instruments (PA)
„ Analyzers (PA)

© 2007-06 V02 ABB Automation Products GmbH - 2


PROFIBUS
Instruments
Benefits

Overview
Flow Instruments Benefits of PROFIBUS:
(DP)
Analyzers (DP)
Actuators (DP)
Remote I/Os (DP) Status Information with every measured value available describing
Positioners (PA) the health of the process value.
Temperature
transmitters (PA) Diagnosis information is immediately available when condition has
Pressure been reached.
Transmitters (PA)
Multivariable
FISCO model available for intrinsic safe installations. Allows easy
Transmitters (PA)
Flow Instruments installations in hazardous areas without system certification.
(PA)
Analyzers (PA) High resolution of process value Allows the complete use of the
operating range of transmitters, without loosing the accuracy.

© 2007-06 V02 ABB Automation Products GmbH - 3


PROFIBUS
Instruments
Benefits

Overview
Flow Instruments Benefits of PROFIBUS devices from ABB:
(DP)
Analyzers (DP)
Actuators (DP)
Remote I/Os (DP) Customized Function Blocks with rich functionality and special
Positioners (PA) parameter sets
Temperature
transmitters (PA) Instruments available with intrinsic safety option (FISCO certified)
Pressure
Transmitters (PA) Asset Monitors with generic and advanced diagnosis /
Multivariable
Transmitters (PA)
maintenance information data
Flow Instruments
(PA) Wide product portfolio (Temparature-, Pressure-, Flow
Analyzers (PA) measurement, Analytical devices, Positioners, …)

FDT/DTM with rich multimedia capabilities and optimized usability


available for instruments

© 2007-06 V02 ABB Automation Products GmbH - 4


PROFIBUS
Instruments
ABB Instrumentation

Overview
Flow Instruments ABB Instrumentation manufacturing sites worldwide:
(DP)
Analyzers (DP)
Actuators (DP)
Remote I/Os (DP)
Positioners (PA)
Temperature
transmitters (PA)
Pressure
Transmitters (PA)
Multivariable
Transmitters (PA)
Flow Instruments
(PA)
Analyzers (PA)

© 2007-06 V02 ABB Automation Products GmbH - 5


PROFIBUS
Instruments
PROFIBUS DP Product Portfolio

Overview
Flow Instruments
(DP)
Analyzers (DP)
Device overview
Actuators (DP)
Remote I/Os (DP)
Data Sheet 10/63-0.47
Positioners (PA)
Process application
Temperature Technical data
transmitters (PA) FISCO approval
Pressure Ex certification
Transmitters (PA)
Multivariable
Transmitters (PA) Ápplication
PNO Ident No.
Flow Instruments PA-Profile
(PA) RB, TB, AI, AO Blocks
Analyzers (PA) Communication modules

© 2007-06 V02 ABB Automation Products GmbH - 6


PROFIBUS
Instruments
Flowmeter – FCM2000 (Trio-Mass)
Physics: EIA485 (PROFIBUS DP)
Overview Protocol: PROFIBUS DP-V0
Flow Instruments Max. Baud Rate: <= 1.5 MBit/s
(DP) IdentNumber: 0x6666
Analyzers (DP) Function Blocks: -
Actuators (DP) Function Blocks: -
Remote I/Os (DP) Data length (cyclical): read -> 16 Byte, write 16 Bytes
Positioners (PA) Device Configuration: Keypad and Display
Temperature FCM2000
transmitters (PA) IP 67 (IP 68)
Pressure housing
Transmitters (PA)
Multivariable Application: Multivariable Measurement -> Mass Flow, Density, Temperature;
Transmitters (PA) Special applications -> Filling applications, concentration measurement
Flow Instruments Ambient temperature: -25 ... +60 °C
(PA) Versions: II ½ G EEx em [ib] IIC T6 (sensor)
Analyzers (PA)

© 2007-06 V02 ABB Automation Products GmbH - 7


PROFIBUS
Instruments
Flowmeter – FXE4000 (COPA/MAG-XE)
Physics: EIA485 (PROFIBUS DP)
Overview Protocol: PROFIBUS DP-V0
Flow Instruments Max. Baud Rate: <= 1.5 MBit/s
(DP) IdentNumber: 0x6666
Analyzers (DP) Function Blocks: -
Actuators (DP) Function Blocks: -
Remote I/Os (DP) Data length (cyclical): read -> 16 Byte, write 16 Bytes
Positioners (PA) Device Configuration: Keypad and Display
Temperature FXE4000
transmitters (PA) IP 67 (68)
Pressure housing
Transmitters (PA)
Multivariable Application: Electromagnetic Flowmeter. Affortable standard instrument in flanged
Transmitters (PA) and adapter-flanged versions
Flow Instruments Ambient temperature: -25 ... +60 °C
(PA) Versions: non Ex version
Analyzers (PA)

© 2007-06 V02 ABB Automation Products GmbH - 8


PROFIBUS
Instruments
Flowmeter – FXM2000 (COPA/MAG-XM)
Physics: EIA485 (PROFIBUS DP)
Overview Protocol: PROFIBUS DP-V0
Flow Instruments Max. Baud Rate: <= 1.5 MBit/s
(DP) IdentNumber: 0x6666
Analyzers (DP) Function Blocks: -
Actuators (DP) Function Blocks: -
Remote I/Os (DP) Data length (cyclical): read -> 16 Byte, write 16 Bytes
Positioners (PA) Device Configuration: Keypad and Display
Temperature FXM2000
transmitters (PA) IP 67 (68)
Pressure housing
Transmitters (PA)
Multivariable Application: Electromagnetic Flowmeter. Suitable for flow measurement in the chemical
Transmitters (PA) and pharmaceutical industries, the food industry, in water and waste water treatement
Flow Instruments facilities and all other industries
(PA) Ambient temperature: -25 ... +60 °C
Analyzers (PA) Versions: non Ex version

© 2007-06 V02 ABB Automation Products GmbH - 9


PROFIBUS
Instruments
Flowmeter – MMASMF (MagMaster)
Physics: EIA485 (PROFIBUS DP)
Overview Protocol: PROFIBUS DP-V0
Flow Instruments Max. Baud Rate: <= 12 MBit/s
(DP) IdentNumber: 0x07EB
Analyzers (DP) Function Blocks: -
Actuators (DP) Function Blocks: -
Remote I/Os (DP) Data length (cyclical): read -> 10..24 Byte, write -
Positioners (PA) Device Configuration: Keypad and Display
Temperature MMASMF
transmitters (PA) IP 65 (68)
Pressure housing
Transmitters (PA)
Multivariable Application: Electromagnetic Flowmeterfor use with water and waste water. Available in
Transmitters (PA) compact or split architecture
Flow Instruments Ambient temperature: -20 ... +60 °C
(PA) Versions: non Ex version
Analyzers (PA)

© 2007-06 V02 ABB Automation Products GmbH - 10


PROFIBUS
Instruments
Flowmeter – MMASLF (MagMaster LoFlo)
Physics: EIA485 (PROFIBUS DP)
Overview Protocol: PROFIBUS DP-V0
Flow Instruments Max. Baud Rate: <= 12 MBit/s
(DP) IdentNumber: 0x07EB
Analyzers (DP) Function Blocks: -
Actuators (DP) Function Blocks: -
Remote I/Os (DP) Data length (cyclical): read -> 10..24 Byte, write -
Positioners (PA) Device Configuration: Keypad and Display
Temperature MMASMF
transmitters (PA) IP 65 (68)
Pressure housing
Transmitters (PA)
Multivariable Application: Electromagnetic Flowmeter with reduced bore for enhanced performance
Transmitters (PA) at low flow rates
Flow Instruments Ambient temperature: -20 ... +60 °C
(PA) Versions: non Ex version
Analyzers (PA)

© 2007-06 V02 ABB Automation Products GmbH - 11


PROFIBUS
Instruments
Flowmeter – APROBE (AquaProbe)
Physics: EIA485 (PROFIBUS DP)
Overview Protocol: PROFIBUS DP-V0
Flow Instruments Max. Baud Rate: <= 12 MBit/s
(DP) IdentNumber: 0x07EB
Analyzers (DP) Function Blocks: -
Actuators (DP) Function Blocks: -
Remote I/Os (DP) Data length (cyclical): read -> 10..24 Byte, write -
Positioners (PA) Device Configuration: Keypad and Display
Temperature APROBE
transmitters (PA) IP 65 (68)
Pressure housing
Transmitters (PA)
Multivariable Application: Insertion eletromagnetic flowmeter. Alternative to full bore meters for
Transmitters (PA) temporary or permanent use on clean/potable water
Flow Instruments Ambient temperature: -20 ... +60 °C
(PA) Versions: non Ex version
Analyzers (PA)

© 2007-06 V02 ABB Automation Products GmbH - 12


PROFIBUS
Instruments
Flowmeter – FMT500-IG (Sensyflow iG)
Physics: EIA485 (PROFIBUS DP)
Overview Protocol: PROFIBUS DP-V1
Flow Instruments Max. Baud Rate: <= 1.5 MBit/s
(DP) IdentNumber: 0x05CA
Analyzers (DP) Transducer Blocks: Flow
Actuators (DP) Function Blocks: 2 AI (flow, gas temperature), 1 TOT, SET-
Remote I/Os (DP) SET/MOD-TOT (flow totalizer), 1 character input
Positioners (PA) Data length (cyclical): read -> 5..15 Byte, write 0..9 Bytes
Temperature Device Configuration: DTM (FDT 1.2),
FMT500-IG
transmitters (PA) Keypad and Display
IP 67 housing
Pressure
Transmitters (PA)
Multivariable Application: Thermal mass flowmeter for air and gases, determination of mass flow /
Transmitters (PA) standard volume flow and gas temperature
Flow Instruments Ambient temperature: -25 ... +50 °C
(PA) Versions: II 2(1) EEx de [ia] ib II C T4; II 2 D EEx
Analyzers (PA)

© 2007-06 V02 ABB Automation Products GmbH - 13


PROFIBUS
Instruments
Analyzer – AO2000 (Advance Optima)
Physics: EIA485 (PROFIBUS DP)
Overview Protocol: PROFIBUS DP-V1
Flow Instruments Max. Baud Rate: <= 12 MBit/s
(DP) IdentNumber: 0x7503
Analyzers (DP) Function Blocks: -
Actuators (DP) Function Blocks: -
Remote I/Os (DP) Data length (cyclical): read -> 224 Byte, write 224 Bytes
Positioners (PA) Device Configuration: ethernet TCP/IP and HMI Software,
Temperature AO2000 Keypad and Display
transmitters (PA) IP 20 / 54 / 64
Pressure housing
Transmitters (PA)
Multivariable Application: Modular gas analyzers for process analytics and emission monitoring.
Transmitters (PA) Offers a range of different analytical principles.
Flow Instruments Ambient temperature: -20 ... +50 °C
(PA) Versions: II2 G EEx dep [ib] II C T4; II3 G EEx nAC(P) T4
Analyzers (PA)

© 2007-06 V02 ABB Automation Products GmbH - 14


PROFIBUS
Instruments
Analyzers – AX4000 Series
Physics: EIA485 (PROFIBUS DP)
Overview Protocol: PROFIBUS DP-V0
Flow Instruments Max. Baud Rate: <= 12 MBit/s
(DP) IdentNumber: 0x07EB
Analyzers (DP)
Actuators (DP)
Remote I/Os (DP)
Positioners (PA)
AX41x / 43x / 45x AX46x AX48x
Temperature
IP 66 housing IP 66 housing IP 66 housing
transmitters (PA)
Pressure Function Blocks: -
Transmitters (PA) Function Blocks: -
Multivariable Data length (cyclical): read -> 10..24 Byte, write -
Transmitters (PA) Device Configuration: Keypad and Display
Flow Instruments
(PA) Application: Conductivity, pH/Redox for use in water or waste water treatement, Power,
Analyzers (PA) Chemical, pharmaceutical, pulp and paper
Ambient temperature: -20 ... +65 °C
Versions: ATEX Type N FM/CSA C1-D1 (in preparation)

© 2007-06 V02 ABB Automation Products GmbH - 15


PROFIBUS
Instruments
Electrical Actuator
Physics: EIA485 (PROFIBUS DP)
Overview Protocol: PROFIBUS DP-V1
Flow Instruments Max. Baud Rate: <= 1.5 MBit/s
(DP) IdentNumber: 0x9655
Analyzers (DP) Transducer Blocks: Electrical Actuators
Actuators (DP) Function Blocks: 1 AI, Setpoint with status,
Remote I/Os (DP) position with status, digital position
Positioners (PA) Data length (cyclical): read -> 3..10 Byte,
Temperature Contrac Contrac
transmitters (PA) PME, RHD, RHDE LME, RSD, RSDE write 5 Bytes
IP 66 housing IP 66 housing Device Configuration:
Pressure DTM (FDT 1.2)
Transmitters (PA)
Multivariable Application: Intelligent electrical continous Actuators for modulating control.
Transmitters (PA) Ambient temperature: -30 ... +65 °C
Flow Instruments Versions: II 2 GD ck EEx de [ib] ib II B T4 (RHDE..)
(PA) II 2 GD ck EEx de [ib] ib II B T4 (RSDE..)
Analyzers (PA)

© 2007-06 V02 ABB Automation Products GmbH - 16


PROFIBUS
Instruments
I/O System and Remote I/O
Physics: EIA485 (PROFIBUS DP)
Overview Protocol: PROFIBUS DP-V1
Flow Instruments Max. Baud Rate: <= 1.5 MBit/s ; <= 12 MBit/s
(DP) IdentNumber: 0x04D2; 0x08D3 ; 0x0630
Analyzers (DP) Transducer Blocks: -
Actuators (DP) Function Blocks: Analog, Digital
Remote I/Os (DP) Data length (cyclical): read -> together; 0..239,
Positioners (PA) write 0..216 ; 0..112 Bytes
Temperature S900 S800 Device Configuration:
transmitters (PA) IP 20housing IP 20 housing DTM (FDT 1.2)
Pressure
Transmitters (PA)
Multivariable Application: I/O System for zone 1 / 2 or non-Ex applications. Modular design, HART
Transmitters (PA) pass through
Flow Instruments Ambient temperature: -20 ... +60 °C; 0..+55 °C
(PA) Versions: II 2 (1) G EEx [ia] ib IIC T4 and further
Analyzers (PA) [EEx ia] IIC, Class 1 Div. 2

© 2007-06 V02 ABB Automation Products GmbH - 17


PROFIBUS
Instruments
PROFIBUS PA Product Portfolio

Overview
Flow Instruments
(DP)
Analyzers (DP)
Device overview
Actuators (DP)
Remote I/Os (DP)
Data Sheet 10/63-0.46
Positioners (PA)
Process application
Temperature Technical data
transmitters (PA) FISCO approval
Pressure FNICO approval i. p.
Transmitters (PA)
Multivariable Application
Transmitters (PA) PNO Ident No.
PA-Profile
Flow Instruments RB, TB, AI, AO Blocks
(PA) Manufacturer Blocks
Analyzers (PA) e. g. MV
Communication modules
Umin, Inom, Ifde

Complete set of accessories (cable, connectors, …) is also available.


Linking Device LD800P with redundancy capability
completes the portfolio.

© 2007-06 V02 ABB Automation Products GmbH - 18


PROFIBUS
Instruments
Positioner
Physics: MBP (PROFIBUS PA)
Overview PA Profile: V3.0
Flow Instruments Protocol: PROFIBUS DP-V1
(DP) Max. Baud Rate: 31.25 kBit/s
Analyzers (DP) IdentNumber: 0x0639
Actuators (DP) Transducer Blocks: Electro-pneumatic positioner
Remote I/Os (DP) Function Blocks: 1 AO, Setpoint value, Position
Positioners (PA) value, digital position
Temperature Data length (cyclical):
transmitters (PA) TZIDC-110 TZIDC-210
read -> 3..20 Byte, write 5 Bytes
Pressure
Transmitters (PA)
Multivariable Umin, Basic current, Error current: 9.0 V DC, 10.5 mA, 4.5 mA
Transmitters (PA) Application: Intelligent positioner. Precise control of positioning with pneumatic linear
Flow Instruments and rotary actuators. Interference due to shock and vibration.
(PA) Ambient temperature: -40 ... +85 °C
Analyzers (PA) Versions: II 2 G EEx ia IIC T6, II 3 G EEx n A II T6
II 2G EEx d IIC T6, II 2G EEx ia IIC T6

Advanced diagnosis:
Working range adjustment required
Auto adjustment failed
Temperature limit exceeded
Position out of working range

© 2007-06 V02 ABB Automation Products GmbH - 19


PROFIBUS
Instruments
Temperature Transmitter
Physics: MBP (PROFIBUS PA)
Overview Protocol: PROFIBUS DP-V1
Flow Instruments PA Profile: V3.0
(DP) Max. Baud Rate: 31.25 kBit/s
Analyzers (DP) IdentNumber: 0x04c4
Actuators (DP) Transducer Blocks: Temperature
Remote I/Os (DP) Function Blocks: 3 AI, Calculated value,
Positioners (PA) Temperature 1, Temperature 2
Temperature TF212, TF212-EX Data length (cyclical):
transmitters (PA) TF12, TF12-EX
IP 67 housing read -> 5, 10, 15 Byte, write -
Pressure
Transmitters (PA)
Multivariable Umin, Basic current, Error current: 9.0 V DC, 11.8 mA, 3.2 mA
Transmitters (PA) Application: Temperature / Sensor head mounting, field mounting
Flow Instruments Pt50…Pt100…Pt1000, Ni100
(PA) Ambient temperature: -40 ... +85 °C
Analyzers (PA) Versions: II 2 G EEx ia IIC T6, FISCO

Advanced diagnosis:
Sensor 1 out of range (Low, High)
Sensor 1 break
Sensor 2 out of range (Low, High)
Sensor 2 break

© 2007-06 V02 ABB Automation Products GmbH - 20


PROFIBUS
Instruments
Pressure and Level Transmitter – 2600T (264xx)
Physics: MBP (PROFIBUS PA)
Overview Protocol: PROFIBUS DP-V1
Flow Instruments PA Profile: V3.0
(DP) Max. Baud Rate: 31.25 kBit/s
Analyzers (DP) IdentNumber: 0x052b
Actuators (DP) Transducer Blocks: Pressure
Remote I/Os (DP)
Positioners (PA)
2600T 2600T 2600T
Temperature
(264BS, 264Dx) (264xx) (264xx)
transmitters (PA)
Pressure Function Blocks: 2 AI
Transmitters (PA) Data length (cyclical):
Multivariable read -> 5, 10 Byte, write -
Transmitters (PA)
Flow Instruments
(PA) Umin, Basic current, Error current: 9.0 V DC, 10.5 mA, 9.5 mA
Analyzers (PA) Application: Differential Pressure / Flow / Level / Gauge / Absolute Pressure /
Density with direct mount or remote seal(s)
Ambient temperature: -40 ... +85 °C
Versions: EEx ia IIC T4-T6, EEx d IIC T6, FISCO
Advanced diagnosis:
Temperature sensor failed
Critical sensor memory error
Electronics memory error

© 2007-06 V02 ABB Automation Products GmbH - 21


PROFIBUS
Instruments
Pressure and Level Transmitter – 2600T (265xx)
Physics: MBP (PROFIBUS PA)
Overview Protocol: PROFIBUS DP-V1
Flow Instruments PA Profile: V3.0
(DP) Max. Baud Rate: 31.25 kBit/s
Analyzers (DP) IdentNumber: 0x04c2
Actuators (DP) Transducer Blocks: Pressure
Remote I/Os (DP)
Positioners (PA)
2600T 2600T 2600T
Temperature
(265Ax) (265Dx, 265Jx) (265Gx)
transmitters (PA)
Pressure Function Blocks: 1AI, 2 AI
Transmitters (PA) Data length (cyclical):
Multivariable read -> 5, 10 Byte, write -
Transmitters (PA)
Flow Instruments
(PA) Umin, Basic current, Error current: 10.2 V DC, 11.7 mA, 5.6 mA
Analyzers (PA) Application: Differential Pressure / Gauge / Absolute Pressure
Ambient temperature: -40 ... +85 °C
Versions: II 1/2G EEx ia IB T4, FISCO

Advanced diagnosis:
Pressure out of adjusted range
Device is busy
Invalid configuration

© 2007-06 V02 ABB Automation Products GmbH - 22


PROFIBUS
Instruments
Multivariable Transmitter
Physics: MBP (PROFIBUS PA)
Overview Protocol: PROFIBUS DP-V1
Flow Instruments PA Profile: V3.0
(DP) Max. Baud Rate: 31.25 MBit/s
Analyzers (DP) IdentNumber: 0x062d
Actuators (DP) Transducer Blocks: Pressure, Temp., Manufacturer specific
Remote I/Os (DP) Function Blocks: 3 AI, Differential Pressure, Rated Pressure
Positioners (PA) Process Temperature; 1 MV , Mass Flow and/or Volume Flow
Temperature Data length (cyclical):
2600T
transmitters (PA) read -> 5, 10, 15, 20, 25 Byte, write -
(267Cx, 269Cx)
Pressure
Transmitters (PA)
Multivariable Umin, Basic current, Error current: 10.1 V DC, 12.0 mA, 11.0 mA
Transmitters (PA) Application: Multivariable Transmitter / Flow, Differential Pressure, Absolute Pressure
Flow Instruments Process Temperature
(PA) Ambient temperature: -40 ... +85 °C
Analyzers (PA) Versions: II ½ G EEx ia IIB T4

Advanced diagnosis:
Pressure out of adjusted range
Device is busy
Invalid configuration
Pressure out of sensor limits

© 2007-06 V02 ABB Automation Products GmbH - 23


PROFIBUS
Instruments
Electromagnetic Flowmeter – FXE4000
Physics: MBP (PROFIBUS PA)
Overview Protocol: PROFIBUS DP-V1
Flow Instruments PA Profile: V3.0
(DP) Max. Baud Rate: 31.25 MBit/s
Analyzers (DP) IdentNumber: 0x0691
Actuators (DP) Transducer Blocks: Flow
Remote I/Os (DP) Function Blocks: 1 AI, Volume Flow;
Positioners (PA) 2 TOT , Flow Counter backwards, forward, differential
Temperature Data length (cyclical):
FXE4000
transmitters (PA) read -> 5, 10, 15 Byte, write 0..4 Bytes
IP 67 housing
Pressure
Transmitters (PA)
Multivariable Umin, Basic current, Error current: 9.0 V DC, 13.0 mA, 4.0 mA
Transmitters (PA) Application: Electromagnetic Flowmeter, Affortable standard instrument in flanged and
Flow Instruments adapter-flanged version.
(PA) Ambient temperature: -25 ... +60 °C
Analyzers (PA) Versions: II 2 G EEx emd[ia/ib] IIC T3..T6

Advanced diagnosis:
Electronic failure
Database error
Temperature measurement failure
Test Mode – active

© 2007-06 V02 ABB Automation Products GmbH - 24


PROFIBUS
Instruments
Electromagnetic Flowmeter – Fx4000
Physics: MBP (PROFIBUS PA)
Overview Protocol: PROFIBUS DP-V1
Flow Instruments PA Profile: V3.0
(DP) Max. Baud Rate: 31.25 kBit/s
Analyzers (DP) IdentNumber: 0x05DC
Actuators (DP) Transducer Blocks: Flow
Remote I/Os (DP) Function Blocks: 2 AI, Flow, Temperature;
Positioners (PA) 1 TOT , Flow Counter
Temperature Data length (cyclical):
FV4000, FS4000
transmitters (PA) read -> 5, 10, 15 Byte, write 0..2 Bytes
IP 67 housing
Pressure
Transmitters (PA)
Multivariable Umin, Basic current, Error current: 9.0 V DC, 10.0 mA, 3.0 mA
Transmitters (PA) Application: Vortex- and Swirl-Flowmeter. For vapor, gas and liquids.
Flow Instruments Ambient temperature: -55 ... +70 °C
(PA) Versions: II 2 G EEx ia IIC T4
Analyzers (PA)

Advanced diagnosis:
Electronic failure
Database error
Temperature measurement failure
Test Mode – active

© 2007-06 V02 ABB Automation Products GmbH - 25


PROFIBUS
Instruments
ph/ORP/pION ; conductivity analyzer - TB82PH, TB82EC
Physics: MBP (PROFIBUS PA)
Overview Protocol: PROFIBUS DP-V1
Flow Instruments PA Profile: V3.0
(DP) Max. Baud Rate: 31.25 kBit/s
Analyzers (DP) IdentNumber: 0x5101, 0x5102, 0x5103, 0x5104
Actuators (DP) Transducer Blocks: Analyzer
Remote I/Os (DP) Function Blocks: 2 AI
Positioners (PA) Data length (cyclical):
Temperature TB82PH TB82EC/TC/TE read -> 5, 10 Byte, write -
transmitters (PA) IP 65 housing IP 65 housing
Pressure
Transmitters (PA)
Multivariable Umin, Basic current, Error current: 9.0 V DC, 15.0 mA, 10.0 mA
Transmitters (PA) Application: Process Analytics solution Conductivity, pH / ORP / pION
Flow Instruments Ambient temperature: -20 ... +60 °C
(PA) Versions: EEx ia IIC T4, Class I Division 1 up to Class II Division 2 Class III, FNICO
Analyzers (PA)

Advanced diagnosis:
Electronics failure
PV out of limits
Dirty sensor alarm
Temperature out of limits

© 2007-06 V02 ABB Automation Products GmbH - 26


PROFIBUS
Instruments
Details

Find all PROFIBUS certified


products on
http://www.profibus.com

© 2007-06 V02 ABB Automation Products GmbH - 27


PROFIBUS
Instruments
Conclusion

ABB makes the difference…

1010
0101

Freedom Power Reliability

© 2007-06 V02 ABB Automation Products GmbH - 28


PROFIBUS
Instruments

© 2007-06 V02 ABB Automation Products GmbH - 29

Potrebbero piacerti anche