Moisture in the Overwrap

Inside the overwrap all bags exhibit some moisture either due to the nature of the polymer (i.e PVC) and/or due to fresh condensation from the sterilization process.

DRUGS THAT ADSORB TO PVC

1, 2

DRUGS THAT EXACERBATE LEACHING OF DEHP


Paclitaxel Teniposide Dosetaxel Chlordiazepoxide HCl Cyclosporine Lipid Emulsions
Chemical and Physical Compatibility of Selected Drugs in EXCEL Container System 2 Glass and Accumed IV Delivery Systems Drug Additive and Chemical Physical Compatibility Guide
1

EXCEL IV CONTAINERS
Information guide

Nitroglycerin Urokinase Diazepam Calcitriol Lorazepam Miconazole Carmustine Aldesleukin Chlordiazepoxide HCl Insulin Isosorbide Dinitrate Sufentanil Citrate Thiopental Sodium Warfarin Sodium

EXCEL (Large Volume Parenteral) IV CONTAINERS


250mL 500mL 1000mL
EXCEL helps solve four issues: 1. Minimize patient exposure, particularly male infants, to the potentially harmful PVC plasticizer, DEHP. 2. Avoid hanging breakable glass over patients because EXCEL is compatible with many drugs known to be incompatible with PVC. 3. Reduce potential for needlesticks and inadvertent contamination while making medication additions. 4. Minimize environmental impact from disposal of IV bags.

Up to 1 inch (3cc) of solution is acceptable


www.bbraunusa.com Clinical/Tech Support 1-800-854-6851
Rx only. 2005 B. Braun Medical Inc. Bethlehem PA. All rights reserved. EXL700 Y07-530-537 1/06 JH 500

B. Informed.

DEHP-free, latex-free for patient safety

Removing the Overwrap

Medication Administration
The rubber stopper of the EXCEL container is latex-free and can be removed for double spiking.

Spiking the Bag


The safer DEHP-free material may require additional force to spike the bag.

Additional Information
Option a) Hold rigid saddle. Insert the spike into the IV bag by using a back and forth twisting motion.

B. Braun Pressure Cuff


Do not exceed 300mm Hg pressure. Suspend the pressure administration cuff by strap, not by the hanger tab of the EXCEL IV container.

Step 1. Remove the overwrap by starting a tear at any of the depressions on the notched edge. Step 2. Tear the overwrap by running your index nger through the seam of the overwrap.

The medication port can be safely punctured ve times with up to an 18 G needle. Remove set port cover by lifting ring with the thumb and forenger and rolling down. Option b) Hold the set port.Insert the spike into the IV bag by using a back and forth twisting motion.

Linear polymer makes the overwrap easy to open

Pneumatic Tube Transport


Reduce the potential for the container lm getting pinched by placing the container in the carrier on its side and performing a visual check.