Documenti di Didattica
Documenti di Professioni
Documenti di Cultura
08/21/2012 1 of 5
RoHS
MODEL
VOF-65-3.3 VOF-65-5 VOF-65-7.5 VOF-65-9 VOF-65-12 VOF-65-15 VOF-65-24 VOF-65-48
Notes:
output voltage
(Vdc)
output current
max (A)
output power
max (W)
efciency
typ (%)
3.3 5 7.5 9 12 15 24 48
26 40 50 60 65 65 65 65
74 78 78 82 84 85 86 88
1. Ripple & noise are measured at 20 MHz BW with 0.1 F ceramic cap and a 10 F electrolytic capacitors on the output and the two earth ground pads are connected to input earth ground.
VOF-65 - XX
Base Number Output Voltage
cui.com
INPUT
parameter voltage frequency input current inrush current input fuse 110 Vac 220 Vac 115 Vac, full load, cold start 220 Vac, full load, cold start built-in, non-user serviceable conditions/description min 85 47 1.4 0.7 25 50 typ max 264 63 units Vac Hz A A A A
OUTPUT
parameter line regulation load regulation temperature coefcient hold-up time adjustability switching frequency 115 Vac at full load adjustable with built-in trim pot 8 -5 60 +5 conditions/description high line to low line at full load full load to 10% load min typ 0.5 1 0.05 max units % % %/C ms % kHz
OUTPUT
parameter over voltage protection over current protection short circuit protection conditions/description clamped by TVS automatically recovers protected, long term short circuit may reduce reliability 105 min typ max 115 units % %Io
ENVIRONMENTAL
parameter operating temperature storage temperature operating humidity storage humidity operating altitude storage altitude non-condensing non-condensing conditions/description see derating curve min 0 -20 20 20 10,000 3,000 30,000 9,000 typ max 60 85 90 95 units C C % % ft m ft m
cui.com
MECHANICAL
parameter dimensions weight cooling method free air convection or forced air (see derating curves below) conditions/description 4 x 2 x 1.44 (102 x 51 x 36.6 mm) 0.17 min typ max units inch kg
DERATING CURVES
1. output power vs. ambient temperature a. 3.3, 5, 7.5 V models
Load factor( % ) Load factor( % )
100 80 60 40 20 0 0 10 20 30 40 50 60
2 1
100
60 40 20 0 0 10 20 30 40 50 60
Ambient temperature( c)
1 2
Ambient temperature(C)
1 2
MATING CONNECTORS
parameter ac input (CN1) dc output (CN2) conditions/description mates with Molex housing 09-50-3031 with Molex 2878 series crimp contact mates with Molex housing 09-50-3041 with Molex 2878 series crimp contact
MOUNTING METHOD
Horizontal
cui.com
MECHANICAL DRAWING
tolerance: 1.0mm unless otherwise specied
102.0 4.02
94.01 3.70
CN1 1 2 3 L no pin N
51.0 2.01
CN1 3 2 1 4 3 CN2 2 1
43.21 1.70
cui.com
REVISION HISTORY
rev. 1.0 1.01 1.02 1.03 1.04 1.05 description initial release mechanical drawing updates dimension added to drawing applied new spec template added MTBF data V-Innity branding removed date 03/13/2009 08/20/2010 05/02/2011 05/13/2011 09/20/2011 08/16/2012
The revision history provided is for informational purposes only and is believed to be accurate.
CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use. CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness.