OBJECTIVE
This CAD standard establishes the settings for modelling and drawing production using :- Microstation V7 for 3D models used in conjunction with PDS models. - Microstation XM for all other drawing documentation.

LampsOn Alliance is between UGL Resources and Lynas Malaysia SDN.BHD. 600035-WI-EN-2-3-1 Cad Standards Rev: 0 Date: 11/06/2010

Page: 1 of 14

WORK INSTRUCTION CAD Standards


CONTENTS
1.0 2.0 2.1 2.2 2.3 2.4 2.5 2.6 2.7 2.8 2.9 2.10 2.11 2.12 2.13 2.14 2.15 DEFINITIONS ....................................................................................................................... 3 GENERAL............................................................................................................................. 3 Software ............................................................................................................................... 3 Drawing Numbering ............................................................................................................ 3 CAD Filenames & Directory Structure .............................................................................. 3 Seed Files ............................................................................................................................ 3 Drawing Border ................................................................................................................... 4 Drawing Revisions .............................................................................................................. 4 Holds .................................................................................................................................... 4 Primary Search Paths ......................................................................................................... 4 Design File Settings............................................................................................................ 4 Element Settings ................................................................................................................. 5 Standard Symbols............................................................................................................... 5 Level Allocation Tables MicroStation V7 .......................................................................... 6 Level Allocation Table MicroStation Xm ......................................................................... 11 Level Naming Scheme MicroStation Xm......................................................................... 12 Active Level Filter Microstation Xm ................................................................................ 13

LampsOn Alliance is between UGL Resources and Lynas Malaysia SDN.BHD. 600035-WI-EN-2-3-1 CAD Standards Rev: 0 Date:11/06/2010

Page: 2 of 14

WORK INSTRUCTION

1.0

DEFINITIONS
Definition Computer Aided Design. Microstation format graphics files and suffix. Microstation. Intelligent 3 Dimensional Information Structural Design Information model

Abbreviation / Phrase CAD Dgn USTN 3Di SDIM

2.0
2.1

GENERAL
Software
Microstation Microstation J XM V07.01.05.03 shall be used for all 3D modelling. V08.09.04.51 shall be used for all other drawing documentation.

2.2

Drawing Numbering
Refer Project Numbering Specification document 4219298-PM-GS-001.

2.3

CAD Filenames & Directory Structure


Electronic file names shall be identical to the drawing number format followed by the application file extension and all deliverables drawing to be filed in the Project directory on the cad on Perth dc Drive. Example: K:\600035\CAD\Piping\600035-200-PI-DW-10001.dgn

2.4

Seed Files
The Project Seed Files shall be used for the creation of all models and drawings. The seed files contain the default settings described in this document. The following seed files are available. Note: Perth Base (Not the same in Mumbai) uStn Ver mu 7 7 7 7 7 7 8 m

Purpose 1 PDS Piping 2 PDS Equip 3 PDS Raceway 4 Frameworks

Location G:\<proj>\PDS\PDS3D\mdlsdz.dgn G:\<proj>\PDS\PDS3D\eqpsdz.dgn G:\<proj>\PDS\PDS3D\rwysdz.dgn

su mm

su/pu 1000/80 1/80 1000/80 1000/80

mm mm m m m m m mm mm

5 Drawing Manager G:\<proj>\PDS\PDS3D\drwsdz.dgn 6 USTN 3D Models G:\<proj>\PDS\PDS3D\eqpsdz.dgn 7 Other Drawings G:\UGLRCAD\XM\projects\Lynas\ seed\3Dm1000mm80.dgn

mm 1000/7680 mm mm 1000/80 1000/80

LampsOn Alliance is between UGL Resources and Lynas Malaysia SDN.BHD. 600035-WI-EN-2-3-1 Cad Standards Rev: 0 Date: 11/06/2010

Page: 3 of 14

WORK INSTRUCTION CAD Standards


8 2D Schematics G:\UGLRCAD\XM\projects\Lynas\ seed\Lynas2Dmm 8 mm mm 1/1000

The correct seed file for Items 1 to 5 above are selected by the PDS/Frameworks software. Items 6, 7 & 8 require the user to select the correct seed file for the task.

2.5

Drawing Border
The Project Drawing Border shall be referenced into the drawing. The title block shall be filled out at the start of the drawing using the tags provided within the border cells. The first revision shall be filled in, Rev A PRELIMINARY / UNCHECKED A Preliminary Not For Construction stamp shall be placed in the bottom right hand corner of the border sheet above the title block.

2.6

Drawing Revisions
Refer Project Numbering Specification document 4219298-PM-GS-001. Contractual issue revisions shall be flagged with a Revision Triangle and the area revised clouded. Refer Level Allocation Table for settings. Subsequent issues shall remove the previous Revision Triangle and revision cloud. Refer WI-EN-2-3-5 Drawing Issue & Approvals.

2.7

Holds
Holds shall be placed on contractual issue drawings where information is not ready for release. The default Hold Designator shall be placed adjacent to the area on hold and clouded with a reverse cloud. Refer Level Allocation Table for settings. The Hold Designator shall also be placed below the notes area with a description of the hold. All holds shall be allocated from the Project Hold Register. Refer document 600035-WIEN-3-3-3.

2.8

Primary Search Paths


The Configuration variable Primary Search Paths / Reference Files shall be used to set the required search paths for models and specific reference files. The Save Full Path Toggle should not be turned on when attaching Reference Files into a drawing / model. The exception is when a specific drawing is referenced in that is outside the Project cad file area and in that case the Save Full Path toggle should be turned on.

2.9

Design File Settings


Working Units: Master Units Sub Units Resolution Positional Units m mm 1000 80

LampsOn Alliance is between UGL Resources and Lynas Malaysia SDN.BHD. 600035-WI-EN-2-3-1 CAD Standards Rev: 0 Date:11/06/2010

Page: 4 of 14

WORK INSTRUCTION CAD Standards


Working Area 53687 m square Where possible drawing coordinates shall reflect the plant coordinate system. All models shall be correctly positioned with respect to the plant coordinates.

2.10

Element Settings
a) Text Level Font Style Justification Sizes Refer Level Allocation Table MicroStation font 235 (v7 & XM) Top left for single line and multi line text Title Notes 5mm Colour 0, Weight 3 2.5mm Colour 0, Weight 1 (A3 drawings only) 3.5mm Colour 0, Weight 2

Alternative

All fonts shall be placed with Text height / Text width ratio equal to 1. Title Text shall be underlined when in body of drawing. b) Dimensions Dimensions shall be placed as dimensional elements and with association lock enabled. Dimensions shall only be dropped in extreme circumstances. Level Font Text size Alternative Other Symbology Terminator Extension Lines Orientation
V7

Refer Level Allocation Table MicroStation font 235 (v7 & XM) 3.5mm 2.5mm Colour 0, Weight 2 Colour 0, Weight 1 (A3 drawings only) Colour 5, Weight 1 Filled Arrow, Width = 1.0, Height = 0.3 Offset = 0.5, Extension = 0.5 Above Centre View
XM

Orientation Location Justification Alignment

Aligned Above Centre View

Justification Alignment

2.11

Standard Symbols
Symbols shall be as selected from the pull down menu.

LampsOn Alliance is between UGL Resources and Lynas Malaysia SDN.BHD. 600035-WI-EN-2-3-1 CAD Standards Rev: 0 Date:11/06/2010

Page: 5 of 14

WORK INSTRUCTION CAD Standards


2.12 Level Allocation Tables MicroStation V7
TABLE 1 Level Allocation Table for 3D Civil Structural Mechanical Piping Electrical, Instrumentation models TABLE 1 LEVEL DISCIPLINE MODELLING LEVELS 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 Civil LEVEL DESCRIPTION COMMENTS Colour 11, Style 1, Weight 0 (Minor) Weight 1 (Major) Colour 6, Style 1, Weight - vary Colour 4, Style 1, Weight - vary Colour 3, Style 1, Weight 2 Colour 2, Style 1, Weight - vary Colour 5, Style 1, Weight - vary As Required Spare, use as required Spare Spare Spare Spare Spare Spare Colour 4, Style 0, Weight - 2 Colour 4, Style 0, Weight - 2 Colour 4, Style 0, Weight - 2 Colour 2, Style 0, Weight - 2 Colour 2, Style 0, Weight - 2 Spare Colour, Style, Weight as Required Colour, Style, Weight as Required Colour, Style, Weight as Required Line String - Colour 4, Style 1, Weight 3 Colour 2, Style 0, Weight 3 Colour 2, Style 2, Weight 3 Patterning Colour 254, Style 0, Weight 0

Contour Surfaces Roads, Parking, Laydown Railway Signs Trees, Natural Features Existing Buildings Existing Utilities / Services Miscellaneous

SDIM Plan, Text SDIM Alpha Grid Text SDIM Number Grid Text SDIM Holes SDIM Plate Structural Beams Columns Bracing Handrail 25mm Webgrate 32mm Webgrate Grating

LampsOn Alliance is between UGL Resources and Lynas Malaysia SDN.BHD. 600035-WI-EN-2-3-1 CAD Standards Rev: 0 Date:11/06/2010

Page: 6 of 14

WORK INSTRUCTION CAD Standards


26 6mm Plate 25mm Webgrate 32mm Webgrate Grating Cladding Wall ...Roof Fire Proofing Stairs Ladder Equipment Tanks Pumps, Compressors Conveyors Hoppers, Chutes Mobile Equip, Envelopes Standard Man HVAC Platform Layout Grid Lines, Bubbles Process Piping Utilities Piping Small Bore Piping Colour 3, Style 0, Weight 1 Colour 3, Style 2, Weight 3 Colour 3, Style 4, Weight 3 Patterning Colour 254, Style 0, Weight 2 Line String - Colour 11, Style 1, Weight 3 Line String - Colour 13, Style 1, Weight 3 Colour 24, Style 1, Weight 1 Colour 3, Style 0, Weight 3 Line string Colour 4, Style 0, Weight 3 Colour, Style, Weight as Required Colour, Style, Weight as Required Colour, Style, Weight as Required Colour, Style, Weight as Required Colour, Style, Weight as Required Colour, Style, Weight as Required Colour, Style, Weight as Required Colour, Style, Weight as Required Temporary Shapes for use by Structural Common for ALL Disciplines Colour, Style, Weight as Required Colour, Style, Weight as Required Colour, Style, Weight as Required Spare, use as required Spare Spare Spare Spare Spare Temporary Shapes for use by Structural Line String - Colour 3, Style 1, Weight 3 Line String - Colour 2, Style 1, Weight 3 Line String - Colour 4, Style 1, Weight 3 Spare, use as required Spare Spare Spare Spare Spare Lights,

27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51

Mechanical

Piping

Electrical, Instrument

52 53 54 55 56 57 58 59 60 SYSTEM LEVELS

Pipe Supports Electrical Cable Tray Layout Instrument Cable Tray Layout Distribution Boards

Electrical, Instrument Cells

LampsOn Alliance is between UGL Resources and Lynas Malaysia SDN.BHD. 600035-WI-EN-2-3-1 CAD Standards Rev: 0 Date:11/06/2010

Page: 7 of 14

WORK INSTRUCTION CAD Standards


61 62 63 Notes, comments relative to model that are not to be displayed Spare Spare Level normally turned off

LampsOn Alliance is between UGL Resources and Lynas Malaysia SDN.BHD. 600035-WI-EN-2-3-1 CAD Standards Rev: 0 Date:11/06/2010

Page: 8 of 14

WORK INSTRUCTION CAD Standards


TABLE 2

LEV EL

DISCIPLINE

LEVEL DESCRIPTION 300 Dia 400 Dia 300 Dia 400 Dia 300 Dia 400 Dia

Line style 3 4 3 4 3 4 0 0 0 0 0 0 0 0 0 0 0 0 2 0 0 As required 0

Line weight 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2

Line colour 114 114 115 115

Piles broken 8 CONCRETE Pile Out of position Piles 9 10 11 12 13 14 15 16 17 18 19 20 25 26 30 31 Pre cast drain

Pre cast open U drain Precast covered culvert Brick / Block work Brick drains concrete base

Brick drain

40

Grids

Grid bubble, line and text

55

MISCELLANEOUS

Brick/ Block work

LampsOn Alliance is between UGL Resources and Lynas Malaysia SDN.BHD. 600035-WI-EN-2-3-1 CAD Standards Rev: 0 Date:11/06/2010

Page: 9 of 14

Refer Table 3 Concrete Colour Designation

Blinding Footings, Pile caps <=5m3 Footings, pile caps >5m3 and <=50m3 Footings, pile caps >50m3 Ground beams Ground Slabs, Ramps Plinths, Pedestals, Columns Kerbs <=450 high Walls >450 high Liquid retaining Slabs Liquid retaining Walls Suspended Beams Suspended Slabs

WORK INSTRUCTION CAD Standards


TABLE 3 Concrete Colour designation MicroStation V7 DEFINITION Assumed Preliminary Engineered Construction Hold Existing Broken pile Out of position pile co=35 co=37 co=38 co=36 co=39 co=254 co=114 co=115 Layout by designer. No Engineering input. Preliminary size from Engineering. Designed size from Engineering. Model issued for Construction. Element on Hold. Existing Element on Hold. Broken pile. Surveyed position dose not correspond with design drawing.

LampsOn Alliance is between UGL Resources and Lynas Malaysia SDN.BHD. 600035-WI-EN-2-3-1 CAD Standards Rev: 0 Date:11/06/2010

Page: 10 of 14

WORK INSTRUCTION CAD Standards


2.13
TABLE 4 Level Allocation Table for all Engineering Drawing Deliverables Ver 8 Microstation

Level Allocation Table MicroStation Xm

LampsOn Alliance is between UGL Resources and Lynas Malaysia SDN.BHD. 600035-WI-EN-2-3-1 CAD Standards Rev: 0 Date:11/06/2010

Page: 11 of 14

WORK INSTRUCTION CAD Standards


2.14 Level Naming Scheme MicroStation Xm
The level naming scheme for MicroStation XM has been devised to allow for the creation of simple Level Filters to display only the level names of interest to a particular discipline. 1.2 Users cannot modify the existing standard level names or the existing level filters. Users may create new level names; however the names of the levels must adhere to the level naming scheme where the first three characters are one of the following: An_ Ci_ Co_ El_ Me_ Pi_ Pr_ St_ Annotation Civil Concrete Electrical Mechanical Piping Process (P&ID, PFD) Structural

Users may create additional level filters if required on a per drawing basis so that they can restrict the displayed level names. Note that level filters only filter the display of the levels for selection in the level pull down box and in the level manager. Level Filters do not affect the display of any graphics. Use the Level Display dialog for that. Standard level names for MicroStation XM are as shown in fig.1 below. These levels will be available in any CAD file that is opened and should be used where appropriate. The naming scheme is also a guideline so that where more levels are required for any purpose; they should be named using the same consistent naming scheme. This allows any new levels to be included in the existing level filters as the filters are defined as the first three characters of the level name, followed by wild card for the rest of the level name e.g. levels that start with the characters Me_ will be included in the Mechanical level filter. 1.3 The following discipline based level filters exist. Each filter includes the discipline specific levels plus the standard annotation levels (named An_...). FIG 1

LampsOn Alliance is between UGL Resources and Lynas Malaysia SDN.BHD. 600035-WI-EN-2-3-1 CAD Standards Rev: 0 Date:11/06/2010

Page: 12 of 14

WORK INSTRUCTION CAD Standards


2.15
1.4

Active Level Filter MicroSstation Xm


To change the active level filter, select Filter: on the levels pull down box.

With Filter: set to none, all levels displayed.

On the Recall Filter dialog, select the name of the required filter.

LampsOn Alliance is between UGL Resources and Lynas Malaysia SDN.BHD. 600035-WI-EN-2-3-1 CAD Standards Rev: 0 Date:11/06/2010

Page: 13 of 14

WORK INSTRUCTION CAD Standards


Now the list of levels on the level selection pull down is restricted to just the concrete levels plus the standard annotation levels.

With Filter: set to CONCRETE, only Co_ and An_ levels are displayed.