FLSmidth Cross-Bar Cooler

Its the smart way to upgrade your cooler to the new standard. With its modular design, the FLSmidth Cross-Bar Cooler is flexible enough to enable complete or partial upgrades of most existing clinker coolers.

More capacity, less expense


When is an upgrade appropriate? Upgrading to the FLSmidth Cross-Bar Coolers advanced clinker cooling technology is worth considering if you would like to: - - - -
Standard units are preassembled in the workshop to ensure high quality and fast, easy, cost-effective installation.

The upgrade process Since every project is unique, we thoroughly study your existing equipment and operational process to ensure the best solution. Typical steps to the upgrade process encompass the following: - Install new grate/cross-bar units with supporting structure below. - Install a new Air-Blast Controlled (ABC) fixed inlet. - Install the required hydraulic drive system and piping. - Replace or upgrade the existing cooling air fans, as necessary. - Upgrade or install new PLC program and supplementary electrical parts and instrumentation. The upper cooling casing (housing) may or may not be reused, depending on the existing coolers size and condition. The existing kiln firing hood and clinker crusher will also be evaluated. Cost-effective installation Cooler upgrades can typically be accomplished with a one- to two-week extension of your yearly maintenance outage. While the ROI calculation differs for every plant, increased production typically easily justifies the shutdown. Request a customised ROI calculation for details.

Eliminate bottlenecks Increase capacity and/or availability Decrease operating costs No fall through of clinker

Contact your FLSmidth representative for an ROI calculation tailored to your facility. Most plants show a return on investment within less than three years.

Upgrade results at Capitol Aggregates, Texas Before FLSmidth CFG (Controlled Flow Grate) cooler Sloped cooler with 37.5 m2 grate area designed for 1816 t/d Standard cooler loss: 118 kcal/kgcl Tertiary air temperature: <700C (separate take-off) After FLSmidth Cross-Bar Cooler with ABC fixed inlet (8x61) Horizontal cooler with 44.2 m2 grate area (+18%) designed for 2000 t/d Standard cooler loss: 96 kcal/kgcl Tertiary air temperature: >900C (common kiln hood) while maintaining similar secondary air temperature Fan power consumption: high! Fan power consumption: (-20%)

Project Centre Denmark FLSmidth A/S Vigerslev All 77 DK-2500 Valby Copenhagen Tel: +45 3618 1000 Fax: +45 3630 1820 E-mail: info@flsmidth.com

Project Centre USA FLSmidth Inc. 2040 Avenue C Bethlehem, PA 18017-2188 Tel: +1 610-264-6011 Fax: +1 610-264-6170 E-mail: info-us@flsmidth.com

Project Centre India FLSmidth Private Limited FLSmidth House 34, Egatoor, Kelambakkam (Rajiv Gandhi Salai, Chennai) Tamil Nadu 603 103 Tel: +91-44-4748 1000 Fax: +91-44-2747 0301 E-mail: indiainfo@flsmidth.com

www.flsmidth.com

Copyright 2011 FLSmidth A/S. ALL RIGHTS RESERVED. FLSmidth is a (registered) trademark of FLSmidth A/S. This brochure makes no offers, representations or warranties (express or implied), and information and data contained in this brochure are for general reference only and may change at any time.

C 01-11 400-3-ENG V2

Potrebbero piacerti anche