Sei sulla pagina 1di 26

www.marsen.co.

kr

OUR MANUFACTURING PRODUCT


CARGO TANK MONITORING SYSTEM (CARGO-2000, RADAR/MAGNETIC FLOAT TYPE) INDEPENDENT TYPE CARGO HIGH/OVERFILL ALARM SYSTEM (HAI-2000, MAGNETIC FLOAT/CAPACITANCE TYPE) TANK LEVEL GAUGING SYSTEM (BAL-2000, PURE PNEUMATIC/ELECTRO PNEUMATIC/ELECTRIC PRESS. TYPE) PRESSURE MONITORING SYSTEM (VIP-2000) VAPOUR EMISSION & CONTROL SYSTEM (VECS-2000) TEMPERATURE MONITORING SYSTEM (TEMP-2000) GAS MONITORING SYSTEM (GAS-200) BILGE ALARM SYSTEM (BOA-2000) WATER INGRESS ALARM SYSTEM (WIA-2000) DE WATERING SYSTEM (WIP-2000) AUTO HEELING WITH INCLINOMETER SYSTEM (HEEL-2000) DEAD MAN ALARM SYSTEM (WATCH-2000) SHIP'S CCTV SYSTEM (CCTV-2000) VALVE OPERATING VIEWER CONTROLLER (V-CON) 15PPM BILGE ALARM SYSTEM (BAM-2000) SALINITY METER (SAL-2000) VISCOMETER (VIS-2000) TEMP. TRANSMITTER & SENSOR (TT-420) GAS SENSOR & TRANSMITTER LEVEL SENSOR (SWITCH & TRANSMITTER) I.S BARRIER & ISOLATOR I.S SENSOR (CAPACITANCE, INDUCTANCE, REED, ULTRASONIC etc) MEASURING SENSOR ROBOT FOR SHIP'S ENVIRONMENTAL CONTROL & MEASURING SYSTEM FOR SHIP'S

SERVICE NETWORK
CHINA (BRANCH)
SHANGHAI VIKING AUTOMATION CONSULTING CO., LTD. RM 1009B #1065 WU ZHONG ROAD, MINHANG DISTRICT, SHANGHAI, CHINA, 201103 TEL : +86-21-5150-3630 FAX : +86-21-5150-3635 E-mail : myongchae@naver.com

SIGNAPORE (BRANCH)
DUNE SHIPPING PTE LTD. BLK624, SENJA ROAD, #04-100, SINGAPORE 670624 NO.4, TUAS LINK 1, SINGAPORE 638591 TEL : +65-6763-9935(3 lines) FAX : +65-6269-2317 E-mail : dune@duneship.com

OIL DISCHARGE MONITORING ULLAGE INTERFACE DETECTOR PRESSURE MONITORING GAS MONITORING LEVEL MONITORING TEMP MONITORING

TURKEY (AGENT)
ARTI DENIZCILIK SNA.TIC.LTD. SEMSETTIN GUNALTAY CAD. NO:37/2 SENESENEVLER-ISTANBUL / TURKIYE TEL : +90-216-464-0059 FAX : +90-216-464-0089 E-mail : arti@artidenizcilik.com

DUBAI (AGENT)
MIDDLE EAST FUJI LLC TEL : +971-4-3474444 FAX : +971-4-3472771 Web : www.mef.ae

TAIWAN (AGENT)
PILOT MARINE TECHNOLOGY & ENGINEERING CO., LTD. NO.217, SHIENG SHENG ROAD, CHUAN CHENG DIST., KAOHSIUNG, TAIWAN, R.O.C ZIP CODE 23660812 TEL : +886-7-8211507 FAX : +886-7-8211571 E-mail : pilotm@ms9.hinet.net

INDONESIA (AGENT)
PT.GLOBAL TRADING LTD. JI.RUKO VILLA GADING INDAH NO. BL A2/2 KELAPA GADING BARAT JAKARTA VTARA 14241 TEL : +21-4509265 / 45845707 FAX : +21-4509274

AGENT
3153, MYEONGJI-DONG, GANGSEO GU, BUSAN CITY, REPUBLIC OF KOREA TEL : +82-51-831-2108 +82-(0)70-7433-2770 FAX : +82-51-831-2109 E-mail : marsen@marsen.co.kr WEB : www.marsen.co.kr

Printed in Oct. 2011

Technical date in this brochure may be changed without prior notice. Do not copy thos catalogue without permission of us

MST-TC-111020-V6.0

World reading company inside measuring and control

CEO MESSAGE
The leading company in the field of level measurement of control technology of marine engineering. Hopping your business to be prosperous continuously, we sincerely appreciate your cooperation and support since its establishment in 2004. Marsen Co,. Ltd. was found in 2004 a manufacturer to make a top leading company in the field of instrumentation for level control and monitoring under the company motto of customer satisfaction quality assurance, maintenance of the quality in the world. since that time, we have been continuously making very possible effort to develop a wide variety of instrumentation such Level,Temp, Pressure and Ex-proof device to meet diversified demands of our customer. As a result of the continuous effort, we Marsen Co., Ltd. has grown into one of the leading companies in the field of level measurement of control technology of marine engineering. We acquired in the quality assurance system certificate conform to Quality system standard ISO9001 and Class Certificate for cargo tank monitoring system, I.S barrier and all kind of Sensor. We will continue striving to contribute to the better world of shipbuilding industry and a leader in the world under our motto of customer satisfaction, quality assurance, maintenance of the quality, and business rationalization among men. Many thanks and wish for your health.

CEO K.S. KIM

www.marsen.co.kr

02

03

www.marsen.co.kr

World reading company inside measuring and control

www.marsen.co.kr

Cargo Tank Monitoring System with Pressure/Temp


General Information
The radar sensor gauge is the best version of radar level gauge for marine tankers which has been made based on the long time field experience & stopless research and development. It is designed solely for measuring the distance, level, volume and reflectivity of liquids, pastes, slurries, and solids. Radar sensor can form part of an overfill protection system as defined in WHG if ordered with the the appropriate options. Radar sensor is a level metter based upon FMCW radar. It is used for measuring Level, Volume, distance to surface, reflectivity of liquids, pastes and slurries. Radar sensor is a newgeneration level meter with a wizard-driven setup, fully-potted electronic subassemblies, an online help functions. Radar sensor gauge safety module located in the cargo control room by means of the pressure and temp.

CARGO-2000 (Radar Type)


Technical Data
Measuring range Accuracy(at reference conditions) Repeatability Measured value resolution Operating mode Beam angle Local Display Hazardous locations Ambient temperature(signal converter) Flange temperature Ingress protection(signal converter) Media Physical properties Dielectric constant Product limitations Process temperature Signal converter Flange system/antenna Gaskets Process temperature Powered by Protocols Current output Ex approvals IACS approvals 0~40m / 0~132ft up to 20m / 66ft 2mm / 0.08 0.5% error of measurement 0.1mm / 0.04 FMCW[Frequency Modulated Continuous Wave]24Ghz 5 Graphical LCD with to touch screen Intrinsically safe, zone 0, 1, 2 Temperature classes : T6 T1 Explosion groups : llA llC -40 +200 / -40+160 -40 +200 / -40+390 optional -60 +250 / -75 +480 lP67 Measures all liquids and solids no effect on measurement results 1.5 liquid ammonia, liquid hydrogen, liquid helium unrestricted(but be aware of ambient and flange temperatures) stainless steel 316L stainless steel 316L[1.4404][standard]or 3% Molybden Mo FPM[Viton], Kalrez 6375[others optional] DIN 2501 DN 125 / PN 16[standard] DC 24V HART 4~20mA passive Intrinsically safe according to ATEX DNV, ABS, GL, LR, BV, CCS, KR NK, RINA[pending]

Principle of operation
The radar sensor gauge is Radar Type level transmitter using a frequency modulated continuous wave(FMCW) electromagnetic signal to measure the distance between its antenna and the cargo tank content surface(ullage). Frequency difference between transmitted and received wave is directly proportional ullage. An adapted data processing is able to be calculated. The micro wave signal issued from the antenna is directly processed, then we can obtain the distance between antenna and liquid surface(ullage).

Application
Ship's Radar tank gauging in storage vessels. Level measurement in processing vessels, reactors, blenders, scrubbers and mixers. Hygienic radar systems for distillation and purified water vessels even with water sprays. Interfaces on some special applications/liquids. Monitoring handling of high temperature molten products, inc metals minerals and coke products.

RADAR LEVEL TRANSMITTER

www.marsen.co.kr

04

05

www.marsen.co.kr

World reading company inside measuring and control

www.marsen.co.kr

Cargo Tank Monitoing System with Magnetic Float


General Information
The CARGO-2000 is the best version of magnetic float level gauge for marine tankers which has been made based on the long time field experience & stopless research and developments. It is a magnetic float type tank level gauge featuring an S.O.S (System One Sensor) that tank level, temperature, vapour pressure as well as issuing an alarm when limits are exceeded. This system is widely suitable for measurement and control of cargo liquid levels at crude oil tanker, coaster tanker, product carriers and chemical carriers etc. A key feature of the tank monitoring system is its easy of handling, because the sensors in the detector are flexible, it can be lifted up by hand without the need to enter tanks, even in the case of cargo tanks of all liquid carrier. All system is automatically operation and easy installation.

CARGO-2000 (Magnetic Float Type)


Specification
VALUE Detection unit Measuring range Accuracy Material Ex. Proof Enclosure SPECIFICATION Alarm inside measuring range (0 to 35meter) Level: 0~35 meter users request Temp: PT100 or PT1000 Level: 0~35 meter (or users request) Temp: basic 3 point -30 to 200 (expand available) Level: 10mm (option 5mm) Temp: +/- 1.0 SUS 304/ SUS 316 / PTFE intrinsicallay safety Ex ia C T6 IP 56 & IP 67 & IP 68 wide lcd display 7- segment available Level: 5mm indication (1mm indication option) Total 0 to 35,000mm & alarm condition display Temp: 3 point (more point option) or available 0 -999 range 4~20mA analog signal RS 232 / RS 422 / RS 485 (option) contact output (for outer alarm) -25 to 75 min 0.65 max 1.5 AC 110/220 & 50/60Hz

Features
Compact & cost saving design Reliable Reed Switch 3 Point Temp sensor available Microprocessor based operating program Easy widely spread LCD display Patent product in case of sensor All product & liquid measuring

Application
TANKER CHEMICAL TANKER OFFSHORE CRUDE OIL CHEMICAL SEA WATER FRESH WATER GAS STATION OIL or LIQUID A STORING PLACE FRESH WATER GAS STATION Sensor - Float Level Sensor - Temperature sensor 3 point - Environmental Housing

Indication

Component
Controller - Wide LCD panel - 7-Segment available - Power supply - Signal Converter Barrier Cabinet - Intrinsically Safety Barrier

Out put Ambient temp Specific gravity Power

www.marsen.co.kr

06

07

www.marsen.co.kr

World reading company inside measuring and control

www.marsen.co.kr

Independent Type Cargo Tank High/Overfill Alarm System


General Information
The HAI-2000 is the best version of magnetic float alarm and capacitance type for marine tankers which has been made based on the long time field experience & stopless research and developments. It is a magnetic float type tank high overfill alarm sensor featuring an stable function. This signal is connected to alarm modulator through safety barrier. The 95% of volume is normally for high alarm and 98% of volume is normally overfill alarm. A test lever is provided for manually functional test to check integrity of high level alarm system before cargo loading. In hazardous areas, this equipment should be used in conjunction with an intrinsically safety barrier. Generally our made other system can be add up for low costs.

HAI-2000 (Magnetic Float/Capacitance Type)


Specification
Magnetic Float Type Valve Specification single / dual / add to temp Sensor type SUS 316 Sensor material 5 Kgf/cm2 Max pressure 0~2,500mm users request Measuring range Working temp -20 ~ +150 Accuracy Level: 10mm (option 5mm) IP 68 Enclosure Ex proof Ex ia C T6 spst or users request Contact Temp accuracy +/- 1 0.6 above Specific gravity 95% at volume (high) Nominal range 98% at volume (overfill) Capacitance Type Valve Specification CLS-420 Model JIS 5K 100A (standard) Conn. Size Housing-SCS13 Flange-SUS304 or SUS316 Material Sensor Probe-SUS316L/PTFE 18 to 28 VDC Power Supply 4~20mA current loop with 8mA-no alarm Output 16mA-alarm AMB-25 to 70 Operating Temp. LIQUID-40 to 150 IP56 over Protection Ex ia C T6 Safety

Features
Simultaneous measurement of level alarm and high temperature alarm by one unit. Designed for all kind of liquid. Most advanced electric technology. for high reliability and durability. Patent product in case of sensor. Simple for construction. Certified by major certifying authorities.

Application
TANKER CHEMICAL TANKER LPG TANKER CRUDE OIL TANKER PRODUCT OIL TANKER LNG TANKER This systems are used for the level alarm in cargo tanks of all kinds of oil & chemical carriers.

Component
Controller - LED panel Barrier Cabinet - Intrinsically Safety Barrier. Sensor - Float Level Sensor / Capacitance Level Sensor - Temperature sensor (Option)

www.marsen.co.kr

08

09

www.marsen.co.kr

World reading company inside measuring and control

www.marsen.co.kr

Ballast & Draft Level Gauging System


Air Purge Type Remote Level Gauging System
Principle of operation
The principle of operation is based on the measurement of the hydrostatic pressure by providing a constant low flow of air or neutral gas into a probe which opens at the tank bottom. The flow regulator is discharged through the purge mouth at the tank bottom and ensure a constant at the end of the sounding pipe in the tank irrespective of the supply pressure. Gauge saver is used for protecting the level indicator against over pressure. The blowing valve in sued for isolation from other channel without any influence. The air supply valve in used for sending the full air pressure through the signal line for cleaning purposes. The output pressure of this constant flow regulator (Corresponding to the hydrostatic pressure at the bottom of the sounding pipe) is connected to the level indicator. The indicator and constant flow regulator are built in interconnecting assembly ready for panel mounting.

BAL-2000 (Pure Pneumatic Type)

Application
<OPEN TANK> Ballast tank remote reading Draft remote reading Heeling and trim remote reading Fuel oil tank remote reading <CLOSED TANK> Cargo oil tank remote reading All liquids even viscous ones (molasses, bitumen, etc.)

Specification
VALUE System type Work temperature Signal pipe Operating air pressure rating Flow rating Range Accuracy SPECIFICATION one line air purge system -30 ~ 70 OD 8mm 4~7 kg/cm2 10 ~ 80 Nl/hour 1 to 40 meter 0.5% os F.S(option) 1.0% os F.S

Features
Liquid level of measuring depth pressure is indicated for direct reading, and then the high precision is achieved. The construction is simple and the handling and maintenance is easy. Since no electricity is used, the explosionproof measures is not necessary. Included stop valve, other pressure is no need for line leakage test.

Components of System

DOUBLE CHECK VALVE www.marsen.co.kr


- MODEL : DCV- Body material : Nabal brass - Connection size : JIS 5K or 10K Flange - Working pressure : Max 10 kg/cm2

FLOW REGULATOR
- MODEL : FRU-200 - Body material : AL - Air supply : 4.5 kg/cm2 - Flow rating : 10~80 NL/H - Blowing pressure : 4.5 kg/cm2

3 WAY COCK

GAUGE SAVER

LEVEL INDICATOR
- MODEL : PLG-200 - Dimension : 144 144 55.5mm - Accuracy : 1.5% of Full Scale - Scale Range : - Working Temperature
Gas : -20~65 Fluid : -20~80

10

- MODEL : MCK-200 - MODEL : GSU-200 - Fluid : Air/Inert Gas - Body material : AL - Operating Pressure : 0 to 1.0 MPa - Differential : Below 0.01 kg/cm2 - Ambient and Fluid Temperature : -5 to 60 (No Freezing) - Effective Area : 19 sqmm - Lubrication : Not Required (Use Turbine Oil Glass 1 ISO VG32, lf Lubricated) - Port Size : 1/4

11

www.marsen.co.kr

World reading company inside measuring and control

www.marsen.co.kr

Ballast & Draft Level Gauging System


Air Purge Type Remote Level Gauging System
Principle of operation
The principle of operation is based on the measurement of the hydrostatic pressure by providing a constant low flow of air or neutral gas into a probe which opens at the tank bottom. The output pneumatic signal of the modulator is fed into P/I converter and is changed to electric signal (4~20mA) in 2 wire by P/I convertor. The electric output signal(4~20mA) can be connected to C.R.T display cargo system, Digital indicator, analogue type indicators, etc. or a combination of these system.

BAL-2000 (Electric/Pneumatic Type)

Features
Liquid level of measuring depth pressure is indicated for direct reading, and then the high precision is achieved. The construction is simple and the handling and maintenance are easy. 4~20mA output signal 2-wires. Blowing valve is select type(change over type). So blowing is very easy. Included stop valve at air purge head, other pressure is no need for line leakage test.

Application
Ballast tank remote reading Draft remote reading Fuel oil tank remote reading All liquids even viscous ones (molasses, bitumen, etc.)

Specification
VALUE System type Work temperature Signal pipe Operating air pressure rating Flow rating Range Power supply Output Accuracy SPECIFICATION one line air purge system -30 ~ 70 OD 8mm 4~7 kg/cm2 10 ~ 80 NI/hour 1 to 40 meter 16 to 32 VDC 4 ~ 20mA 2 wire system 0.5% os F.S (option) 1.0% os F.S

Components of System

P/I CONVERTER
- MODEL : PHDH-200 - Excitation(Calibration Voltage) : DC 24V - Excitation : DC 11~28V - Output : 4~20mA (2wire) - Accuracy(RSS) : 0.5% F.S - Compensated Temerature Range : 0~70 - Operating Temperature Range : -20~80 - Thermal Effect on Zero : 0.03% F.S/ - Thermal Effect on Span : 0.03% F.S/

ANALOGUE INDICATOR www.marsen.co.kr


- MODEL : MAG-200 - Input : 4~20mA - Internal resistence : 10 ohm - Indicating accuracy : High value of 1.0 Full Scale - Dimension : 110 110 - Color : Black

12

www.marsen.co.kr

13

World reading company inside measuring and control

www.marsen.co.kr

Tank Level Gauging System


Principle of operation
The ceramic measuring cell is oil-free, I.e the process pressure acts directly on the rugged ceramic diaphragm of pressure transmitter and causes it to move by a max, 0.025mm. A pressure-dependent change in capacitance is measured by the electrodes in both the ceramic substrate and the diaphragm. The measuring range is determined by the thickness of this ceramic diaphragm.

BAL-2000 (Electric Pressure Type)


Specification
VALUE Principle Output Accuracy Supply voltage Material Measuring cell Explosion protection Operating temperature range SPECIFICATION Converting hydrostatic pressure of a column of liquid into a level-L-proportional signal. 4~20mA 0.2% of F.R 12~30V DC Diagram-AI2O3aluminum oxide ceramic probe housing-SUS 316 Seal-viton oil-free dry sensor Ex ia C T6 -20~100

Features
With is high electrical and mechanical stability, pressure transmitter fulfills all plant construction standards. Ceramic measuring cell-extremely resistant to overload, alternating loads and aggressive media. Support cable with hard-wearing conical seal on the probe tube and climatic protection in the pressure compensation tube. Potted electronics with 4-20mA output signal and integrated overvoltage protection. Certified for hazardous area Ex ia C T6.

Application
Ballast tank remote reading Draft remote reading Fuel oil tank remote reading Wast waters, wells, locks, revers etc.

www.marsen.co.kr

14

15

www.marsen.co.kr

World reading company inside measuring and control

www.marsen.co.kr

Pressure Monitoring System


General Information
The "Cargo Tank Ullage Space Monitoring System including High & Low Pressure Alarm" (VIP-2000) is newly required by IMO SOLAS 74, Chap. -2 Req. 59 become effective on 1. July 1998 for preventing serious deformation of the tank structure from such over/under pressure in case of P/V valve failure. The pressure monitoring system is designed for cargo tank & manifold pressure monitoring for any number of tanks. The ceramic measuring cell is very strong about environmental condition. Also this system can be reduce a calibration fee compared with P/V valve a period calibration because not need a separate that local area can be a calibration. Generally our made other system can be add up for low costs.

VIP-2000
Specification
VALUE Sensor type Sensor material Max pressure Measuring range Working temp Accuracy Enclosure Ex proof Signal Gas kinds Display SPECIFICATION Ceramic (silicon) type pressure transmitter SUS 316L/PTFE up to over pressure (range X2) -500~500mbar (or users request) -20 ~+150 F.S +/- O.5% (or users request F.S +/- 0.25%) IP 68 in case of housing Ex ia C T6 4~20 mA analog signal oil/chemical LCD or 7-Segment display Including alarm condition

Features
Intrinsically safety detecting is applicable to all of inflammable. Ceramic measuring cell- extremely resistant to overload, alternating loads and aggressive media. Each sensor module pressure display Patent product in case of sensor Certified for hazardous area ex proof Certified by major certifying authorities High accurate reading vacuum and press figure

Application
TANKER CHEMICAL TANKER CRUDE OIL TANKER PRODUCT OIL TANKER If user's installed it's system instead of P/V valve, get in a profit both maintenance and cost of certificate

System Principle
The intrinsically safety type cargo tank vapour pressure monitoring system is intended for cargo tank pressure and vacuum pressure monitoring. The ceramic measuring cell is oil-free, ie, the precess pressure acts directly on the rugged ceramic diaphragm of pressure transmitter & causes it to move by a max pressure. The electrical signals from the pressure transmitters on deck are connected to zener barrier in the in the monitoring cabinet equipped with pressure alarm lamp, buzzer and pressure figure indicator in the cargo control room. If expanded system, have a easy expanded designed.

www.marsen.co.kr

16

17

www.marsen.co.kr

World reading company inside measuring and control

www.marsen.co.kr

Vapour Emission & Control System


General Information
This system is intended for measuring oxygen gas content analyzing the waste VOSs gas contents and manifold lines form Oil/Chemical Tanker. All tanker and chemical tanker should be install from19. May. 2005 according to IMO MSC/Cire 585. All necessary parts are intrinsically safety certified product. The Sampling Cabinet in steel case is installed on deck nearby the vapur manifolds and the controller is mounted in the cargo control room. (C.C.R)

VECS-2000
Specification
System Main power supply - AC 110/220V, 50~60Hz System power - DC 24V Air supply - 4~7 bar Range - 0~200mbar Power supply - DC 24V Output - 4~20mA Range - 0~25% O2 Power supply - DC 24V Function -Accept horn, Accept flash, Test function

Press. Transmitter

Operation principle
The system has fourth sample points and only one sample is directed and monitored individually through selecting valve at the time. The sampling cabinet has a include oxygen sensor, vapour pressure transmitter and nonflow sensor with intrinsically safety certified. Measuring oxygen, vapour pressure and non-flow signal send to controller through I.S barrier. All signal is display within wide LCD as to figure and alarm condition. If alarm is occur, controller sound a buzzer, flickering and external signal.

Features
Intrinsically safety detecting is applicable to all of sensing zone. Material is reliable to secure body. Setting figure adjustable in factory. Program Operating Control (P.O.C) Type is easy install and small size. Selectable vapour oxygen contents measure. Another gas can be measure by sensor tip replace only (option). Another gas, pressure and temperature can be expanded easy. Offshore terminal interface function.

Oxygen sensor

Main Component

www.marsen.co.kr

18

19

www.marsen.co.kr

World reading company inside measuring and control

www.marsen.co.kr

Fixed Gas Monitoring & Alarm System


Principle of operation
The fixed gas monitoring system(BGAS-2000) is and automatically scanning Gas sampling system permanent installed for a number of sampling points. The BGAS-2000 are common for all sampling points, allowing the use of high quality gas detectors with good accuracy. A gas monitoring is taken from each sampling point in turn, according to the sampling sequence, and transported through the sampling pipe to the gas detectors. The sampling time for each points is individually adjustable corresponding to the pipe length of each sampling point. This gives an optimally short cycle time. The fixed gas monitoring system(BGAS-2000) is intended for detection of explosive and toxic gases in cofferdams, pipe tunnels, stools, ballast tanks, slop tanks and other areas adjecent to cargo tanks. A pump room installation is normally a separate system. The BGAS-2000 is designed to meet the requirements of IMO/SOLAS and classfication rules.

BGAS-2000
Components of System

Features
Intrinsically safe sample cabinet Up to 48 sample points Expandable in the field with plug-in solenoids Auto and manual purge cycles Auto shutdown and alarm on point flow failure Multiple remote displays on multi-drop network All sensor locations displayed on screen

Application
Sampling of the ballast tanks and void spaces in done by our sampling cabinet. The unit is powered equally by 110 or 220 VAC. The system is connected to ships computer network for viewing, logging and control of the system from any authorized computer on the network.

System Example

Specification
VALUE Power supply Pump capacity Gas detectors Sampling points Suction pipes Outputs Installation accessories SPECIFICATION 110~220 VAC (50~60Hz), 2A 151/min Up to 4 pieces (HC, O2, H2S etc) Maximum 48 with or without counter pressure OD 8 or 10, ID approx. 6 6 relays with 2 switching 5A contacts each standard or custom defined Flame traps, shut off valves, filters, cones, etc. Printer(RS232), NMEA protocol(RS485), Pre-suction pump 151/min, 1~4 Repeater units, pump redundancy, other special arrangements
www.marsen.co.kr

Option

20

www.marsen.co.kr

21

World reading company inside measuring and control

www.marsen.co.kr

Oil Discharge Monitoring Equipment


General Information
The ODM-2000 has an oil discharge monitoring and control system installed, incorporating an approved oil content meter with a starting interlock and an automatic overboard valve control system. The system is fully intrinsically safe using optical fibers. Automatic cleaning is achieved by a pneumatic actuated wiper, all part in contact with the fluid are corrosion proof for long-life in harsh environment. A self-calibration and washing system eliminates most of the mainenance. The system is a high quality product and the components are designed for obtaining long lifetime in a rough environment.

ODM-2000

Features
The measuring range is 0-1000ppm Easy to operate as it is a minimum of button to press and self explanatory menus Robust, easy to install and easy to maintain A unique self-cleaning feature, making manual cleaning virtually unnecessary. Intrinsically safe type, DP transmitter Short response time(15sec) Insensitive to ships motion and vibration Flowmeter working by differential press.

CONTROLLER OIL CONTENT METER HYD. PACAGE

IMO RES. MEPC. 108[49]


Input information : PPM, Flow Rate, Ship's Speed, GPS(Latitude & Longitude), Date & Time. Starting interlock Discharge Valve Control Output Information(Displayed and printed) : L/N.M, Total Quantity, Date & Time, PPM, GPS(Latitude & Longitude)

Specification
Controller and oil content meter power supply : 220V-60Hz or 110V-50Hz Motor/pump power supply : 440V-60Hz or 380V-50Hz, tree phase Ambient temperature : 0~+55 roll and pitch : 22.5 respecting normal installation specifications Humidity : 95%RH at the most at 55 Vibration : 2-13.2 Hz amplitude+1mm Input and output signals

www.marsen.co.kr

22

23

www.marsen.co.kr

NAME Oil content Method of communication Discharge flowrate Log speed Gps Discharge valve Valve position

VALUE 0 to 1000ppm Max. 1,225m3/h 21knots max.

SIGNAL Display Current Loop 4-20mA Impulses NMEA0183 Dry contact Dry contact

World reading company inside measuring and control

www.marsen.co.kr

Temp Monitoring System


General Information
The TEMP-2000 has been specially developed in conformity with SOLAS 2000 Amendments Chap -2 Reg 4 amended for protecting the cargo pump room in tanker. It consists of temperature sensors, safety I.S barriers and temperature monitoring unit having digital display and alarm status. Cargo pumps, Ballast pumps and stripping pumps, installed in cargo pump rooms and driven by shift passing through pump room bulkheads shall be fitted with temperature sensing devices for bulkhead shaft glands, bearings and pump casings. The continuous and audible and visual alarm shall be automatically effected in the cargo control room or the pump control room. Our system is installed special program in temperature measuring and control only. If you spread or special purpose request, will be convert to fast fitted your request.

TEMP-2000
Specification
VALUE Sensor type Sensor material Max measuring temp Measuring range Working temp Accuracy Enclosure Ex proof Signal Fault Installation SPECIFICATION RTD/ TC/ SEMICONDUCTOR SUS 316/VITON UP TO 600 NOMINAL 0~200 -30~ +80 +/- 1.0 (or USERS REQUEST F.S +/-0.5 ) IP 56 IN CASE OF HOUSING Ex ia C T6 RTD/TC/or 4~20mA ANALOG SIGNAL LINE BREAK/SHORT MEASURING BEARING1, BEARING2, INTERMEDIATE BEARING CASING, BULKHEAD SHAFT GLAND FITTING MOUNTING

Features
Easy installation Micro processor type controller Long life sensor Digital display High, Low and another setting available Widely strong interface function Most advanced electric technology for high reliability and durability

Application
The pumps temperature monitoring & alarm panel gives an audible, visible alarm with digital display. The individual external sound and visual alarm device may be prepare in accordance with user's request special option. Another system like as P/R bilge alarm, gas alarm may be prepared with our system if user's request.

www.marsen.co.kr

24

25

www.marsen.co.kr

World reading company inside measuring and control

www.marsen.co.kr

Gas Monitoring Unit


General Information
The GAS-2000 is developed by newly measuring the gas density and toxic, flammable gas exist in pump room. Because pump room is hazardous area, should be install as Ex-proof gas sensor. It consists of complete electro-chemical sensor, intrinsically safe barrier and controller. All product is reliable and strongly operation. Its system installation have a receive a regulation. 2000 SOLAS Amendment, Chap -2 Reg 4 amended for continuous monitoring the connection of hydrocarbon gases in the pump room. The system gives alarm at a gas concentration of about 10% L.E.L as a pre-alarm function and 30% L.E.L as primary alarm which can be set again. Oxygen alarm occurs, if the level of oxygen in pump room are below alarm set point approx. 19 volume metric percent oxygen and then audible & visual alarm activate. Generally our made other system can be add up for low costs.

GAS-200 (Diffusion/Suction Type)


Specification
VALUE Sensor type Sensor material Max pressure Measuring range Working temp Accuracy Enclosure Ex proof Signal Fault Gas kinds Installation SPECIFICATION ELECTRO CHEMICAL GAS SENSOR MARINE ALUMINIUM / SUS 316L/PTFE IP TO OVER ENVIRONMENTAL PRESSURE 0~ 30 % (IN CASE OF OXYGEN) -10 ~ +60 F.S +/- 0.5% (or USERS REQUEST F.S +/- 0.25%) IP 56 IN CASE OF HOUSING Ex ia C T4 4~20mA ANALOG SIGNAL LINE BREAK / SHORT MEASURING OXYGEN / FLAMMABLE/TOXIC WALL MOUNTING

Features
Intrinsically safety detecting is applicable to all of inflammable Easy maintenance unique modular design gives ease of maintenance and sensor cell replacement Long life sensor installation. Patent product in case of sensor Certified for hazardous area ex proof Certified by major certifying authorities High accurate reading another wide gas measuring

Application
Tanker Chemical tanker LPG tanker Crude oil tanker Product oil tanker LNG tanker User's request may be receive to maker another gas kinds measuring, our system will be check all kinds gas density.

System principle
This sensor is a sealed marine aluminium housing environmental flammable gas detector and protected head with a sintered filter which house a poison resistance pair. If gas or oxygen meet a sensor, electro chemical sensor is occurred a electro signal to transmitter and then gas density is convert to current signal. This current signal is send to controller through I.S Barrier. If gas density is over to setting range, sound and visual alarm is occurred and stop a buzzer after manual stop. But, alarm is not reset as manual mode, only auto.

www.marsen.co.kr

26

27

www.marsen.co.kr

World reading company inside measuring and control

www.marsen.co.kr

Valve Remote Control System


General Information
The VRC-2000 is designed for position indication and electro-hydraulic remote control of hydraulically actuated valves. The principle of the VRC-2000 is that pressurized oil, generated by the power pack, is used to open or close the valve by means of the solenoid controlled actuator. Our wide array of valve remote control systems includes hydraulic, pneumatic, electric and electro-hydraulic options.

VRC-2000
Pneumatic/Hydraulic Actuator
SPECIFICATION Class Drawing -25 ~ +70 -20 ~+70 IP56, IP65, IP68 4.6V to 30V DC Unswitched < 0.5A switched > 2.0A AC 110/220V Source : Pneumatic or Hydraulic Acting : Single or Double Connection : G 1/2" MAX press : 10BAR (Pneumatic) 350 BAR(HYD) MIN PRESS : 4BAR (Pneumatic) 80 BAR(HYD) Connection valve : Butterfly or Ball Indication : option -Use : Ballast Tank Easy to install & Simple operating. Fast delivery time & low price. At least maintenance & Long life.

Specification
VALUE Certified to Ambient temperature Liquid temperature Protection class Normal voltage Normal current Measuring voltage

Electric actuator
Source : AC220/110V 50/60Hz Valve : Butterfly of Ball Enclosure : IP 68 Size : 40~100A Manual : Available Indication : Visual indication Use : Dry space

www.marsen.co.kr

28

29

www.marsen.co.kr

World reading company inside measuring and control

www.marsen.co.kr

Water Ingress Alarm System


General Information
This system comprises of alarm monitoring cabinet, Intrinsically safety Barrier and types capacitance liquid detectors installed in each cargo holds and compartment. Our model provide our customer with suitable method for new ships and existing ships.

WIA-2000
Specification
VALUE Sensor type Sensor material Max pressure Working temp Accuracy Enclosure Ex proof Signal Fault Level kinds Installation SPECIFICATION Pressure / Capacitance / Electrode / Float SUS 304 / SUS 316 MAX 5 KG/cm2 -10 ~ +60 +/- 5 mm IP 68 in case of sensor Ex ia C T6 4-20mA Analog Signal Line break / Short measuring / Earth Liquid / Coal / Sea water / Chemical / Solid etc Wall mounting / Penetration mounting

Rules & Regulation


SOLAS X /12 & X /13 IMO RES MSC 145(77) IACS SC180

Technical specification
Main Power : AC 110/220V Emcy Power : DC 24V Max. detecting points : 80 points Ambient Temp' : -25 ~ 70 Sensor Housing Material : SUS 316 Accuracy : +/- 5mm available Sensor enclosure: IP68 Sensor Ex. Grade : Ex ia B T4 Indicating system: LED Pressure : 5 bar Time delay : abt 10 second (by microprocessor control) I.S barrier Grade : [Ex ia] C Overriding point : Max. 48 points Alarm sound : Dual type alarm sound. Interface & Simulation : RS 485 (422) & Simulation test available

Features
Intrinsically safety detection can be applicable to all of inflammable area, if required. No fault and any mechanical moving device for sensor. No moving part and reliable sensing system. A lot of any number of detecting points. Complete dust-proof and waterproof (IP68 - 5bar according to IEC 60529) Available for the overriding device for which the alarm can be de-activated. No electrical and mechanical corrosion. Easy maintenance and installation. Operating by microprocessor. Passed the EMI, EMC testing completely.

www.marsen.co.kr

30

31

www.marsen.co.kr

World reading company inside measuring and control

www.marsen.co.kr

De Watering System
General Information
This system (WIP-2000) is adapted in SOLAS Reg XZI/13 for Bulk Carrier, is designed and developed in compliance with IACS SC 180 rule requirements. This system is for discharging of water from ballast tank or forward dry spaces to overboard remotely. This system is available several method like as Electro, Pneumatic, Hydraulic operating.

WIP-2000

Controller
Source : AC 110V/220V & 50/60Hz Material : SS400 Function : 1) Alarm function 2) Valve operating function (open/close) 3) Power fail (option) 4) Power on/off 5) Horn/Outdoor lamp (option) 6) Digital or Mimic type

Pneumatic/Hydraulic Actuator
Source : Pneumatic or Hydraulic Acting : Single or Double Connection : BSPT 1/4" MAX press : 10BAR (Pneumatic) 350 BAR(HYD) MIN PRESS : 4BAR (Pneumatic) 80 BAR(HYD) Connection valve : Butterfly or Ball Indication : option -Use : Ballast Tank Easy to install & Simple operating. Fast delivery time & low price. At least maintenance & Long life.

Hydraulic Power Pack


Source : AC 220V/60HZ MAX. Prexx : 120 BAR Port : 2 Port Enclosure : IP 68 EM'CY operating : YES (BY HAND PUMP) Weight : 35KG Option : Lock indication. Pneumatic operating

Electric actuator
Source : AC110/220V 50/60Hz Valve : Butterfly of Ball Enclosure : IP 68 Size : 40~800A Manual : Available Indication : Visual indication Use : Dry space

Specification
VALUE Certified to Ambient temperature Liquid temperature Protection class Normal voltage
www.marsen.co.kr

Major Function
SPECIFICATION Class Drawing -25 ~ +70 -20 ~+70 IP56, IP65, IP68 4.6V to 30V DC Unswitched < 0.5A switched > 2.0A AC 110/220V F.P.T TANK Discharge Bosun store discharge Valve open/close indicating Direct/Reverse operation Another panel available

Normal current Measuring voltage

32

33

www.marsen.co.kr

World reading company inside measuring and control

www.marsen.co.kr

Auto Heeling with Inclinometer System


General Information
This system (TIN-2000) has a function monitoring and measuring for inclino and tilt by digital automatic program. Also this system have a function like as digital display, alarm warning, output signal, interface etc. This system is use for construction, ship's building, ship, offshore, crane etc. TIN-2000 may be match several machinery and system like as heeling control system in case of container ship, level gauging system in case of ship's F.O & D.O tanks etc. All control is automatic control by program but in case of emergency control and measuring, may be convert to manual mode. This system is prepare wide range like as 5, 30, 60, 90, 180 and user's request. And all direction is use for from left to right and front to rear or side to side, Its system is measuring to 16 channel basically.

TIN-2000
Auto Heeling with Inclinometer System (TIN-2000-P)

Specification
Auto heeling with inclinometer system (TIN-2000-P)
VALUE Sensor type Direction Measuring degree Display degree Working temp Accuracy Enclosure Max channel Output signal Output alarm Source Alarm setting SPECIFICATION Analog or Digital type All direction (basic 2 direction) 1 , 2 , 3 , 5 , 10 and user's request. 1 , 2 , 3 , 5 , 10 and user's request. -20 ~ +60 F.S 1% (or User's request F.S 0.5%) IP44(controller), IP56 (horn & lamp) 16 channel 4~20mA Analog signal 2 Channel contact (widely available) AC 110V/220V, 50~60Hz or DC 24V User's request (basic alarm 2 point)

Anti Heeling with Inclinometer System (TIN-2000-A)

Specification
Anti heeling with inclinometer system (TIN-2000-A)
<HEEL INDICATOR UNIT> SPECIFICATION VALUE TIN-2000-AH Model AC 100~240V, 1 50/60 Hz Main power 1.5% F.S Accuracy 1.0 sec. Response time Operating temperature 0~45 25~90% RH(NO CONDENSATION) Operating humidity Measuring degree 1 , 2 , 3 and user's request. IP44 Ingress Protection <LAMP INDICATOR UNIT> SPECIFICATION VALUE TIN-2000-AL Model Use voltage DC 24V Max. current 0.480A Casing material SUS 304 Operating temperature -25 ~50 Ingress Protection IP56

www.marsen.co.kr

34

35

www.marsen.co.kr

World reading company inside measuring and control

www.marsen.co.kr

Bridge Navigation Watch Alarm System (B-WATCH-2000)


General Information
Dead Man Alarm System is designed to monitor bridge activity and alert the master or other qualified navigators if the bridge becomes unattended. The system first alerts the officer of the watch through local alarm indication at the bridge unit and, if he is not responding, then alerts the master or other qualified officer. Our Dead Man Alarm System conforms to the requirements of IMO resolution MCS. 128(75) Performance standards for a Bridge Navigational Watch Alarm System (BNWAS) and the bridge class notations for "oneman bridge operation".

Dead Man Alarm System (E-WATCH-2000)


General Information
Dead Man Alarm System should be equipped inside the engine room. The infrared rays sensor catches the on-duty crews position and controller makes alarm for preventing them from nap/sleeping. This aims on its work for prevending crews from the nap/sleeping for safe sailing. This device is for neither catching the sleeping crew, nor making alarm to wake them up.

Specification
VALUE Size (high wide depth) Painting color Material Weight Power supply voltage Number of input Sensor Start(Touch Screen) Alarm Buzzer Extensin Buzzer Contact point signal (for the alarm Panel) Cover Body SPECIFICATION 400 320 180(mm) 7.5 BG 7/2 SS400 SS400 8kg Main AC 110/220V 50/60Hz, Emcy DC 24V 1~6points 1point 1point 1~16point 1point

Operation Principle
System on/off (password protected) Adjust system timers(password protected) Audible and visual alarm indications Keys for sound off and acknowledge of alarms Selection of back-up navigator in duty Call back-up navigator

Requirement
Operating temperature : -15 to +70 Maximum humidity : 96% no condensation Supply voltage : 18 - 32 VDC. 5% ripple Power consumption : 26W (typical) Printer (option)

Type Approval by Ships Class


Number of output

CONTROLLER

www.marsen.co.kr

SENSOR

ALARM BOX

36

37

www.marsen.co.kr

World reading company inside measuring and control

www.marsen.co.kr

Ship's CCTV System (CCTV-2000)


Specification
Source : AC 220V/110V 50/60Hz Camera is color type basic. Camera indoor/outdoor type. Camera rotator/static type. Basic camera 4/8/16 installation. If you can install Deck marine. Should be check IP enclosure. Cable should be sore mold cable.

O2 Analyzer (IGO-200)
General Information
In our supply an O2 analyzer with continous reading and alarm will be included. There will be two alarms, low and high O2 content. The high alarm protects the tanks atmosphere against high O2 contents and the low alarm protects the unit stop the henerator, so the operator can adjust the equipment to correct the O2 content. When the O2 content is too high the inert gas purged to the atmosphere.

Component
L.C.D MONITOR(16:9) - Source : AC 200~240V 50/60Hz - Size : 19inch DIGITAL VIDEO RECORDER(DVR) - Source : AC 200~240V 50/60Hz - Dimension : 380 308 65(W D H) - Operating System : Embedded Linux - Compression : MPEG-4 - Multiplexer Functionality : Triplex(Record, Playback, and Network at same time) CAMERA - Pick up Device : 1/3" Color Sony Super Had CCDII - Color System : PAL(811H 508V) NTSC(768H 494V) - Horizontal Resolution : 380tv Lines - Minimum Illumination : 0 Lux(20M Range) : LED ON : 0.1 Lux(F/1.2) : LED OFF - S/N Ratio : -45db 10% - Source : DC 12V

Specification
VALUE Size (high wide depth) Painting color Material Weight Power supply voltage External output signal Alarm point Signal O2 sensor Point Range SPECIFICATION Size (high wide depth) 7.5 BG 7/2 SS400 5kg AC 100~240V 50/60Hz 4~20mA(DC) Low & High alarm 4~20mA(DC) 1 or 2 points 0~5, 0~10, 0~25%

www.marsen.co.kr

38

39

www.marsen.co.kr

World reading company inside measuring and control

www.marsen.co.kr

Bilge Alarm System (BOA-2000)


General Information
The BOA-2000 is developed to get an sound & visible alarm for high level of pump room bilge well or engine room bilge well. This system consists of bilge alarm controller, intrinsically safety barrier and level switch. When the liquid level reaches a set point, a level switch or transmitter on the bilge well is acting and the alarm signal is given to the controller through intrinsically safety barrier. The audible and visual alarm on the alarm controller should be operated. The level switches shall be modelling into three types float type, capacitance type and displacement type. All sensor is reliable and strong function. This system can be spread up to 500 units sensor sensing. Generally our made other system can be add up for low costs.

Oil Mist Detector (OMD-200)


General Information
Oil mist detection system adopting newest microprocessor and intrared technology was designed for detecting oil mist existence which may possibly happen in the air of both crank chamber of marine engine and such as environments, engine oil pump, purifier room and other machine rooms etc. of the vessel.

Features
Fast response to notify of exceeding allowable limit. Alarm in a potentially dangerous situation. Easy to installation and maintenance Not affected by oil condensation in the air and electrical interference.

Specification
VALUE Sonnection Set point Accuracy Max. Pressure Over pressure Min. Sp gr Contact Signal (4~20ma) Enclosure Ex-proof Material Source FLOAT TYPE JIS 5K 50A STND 120~5000 mm 5mm 5 Bar 7 Bar 0.85 Available Available IP 56 (option IP65) Ex ia C T6 ALDC/SUS316 MAX 250V 0.5A DISPLACEMENT TYPE JIS 5K 100A STND 220~5000 mm 8mm 5 Bar 7 Bar 0.85 Available Available IP 56 (option IP65) Ex ia C T6 ALDC/SUS316 MAX 250V 15A CAPACITANCE TYPE PF 3/4" STND 200 ~ 20,000mm 5mm 5 Bar 7 Bar 0.5 Available Available IP 56 (option IP65) Ex ia C T6 SUS304/SUS316 4~20mA

Specification
VALUE Measurable range Accuracy Alarm contact Power source Protection degree SPECIFICATION 0-2.2mg/L 0.5% Free Contact DC 24V IP54

www.marsen.co.kr

40

41

www.marsen.co.kr

World reading company inside measuring and control

www.marsen.co.kr

Valve Operating Viewer Controller


General Information
This device can be use a control at automatic control valve like as pneumatic and electric. This device using purpose is control and degree like as open/close. Pneumatic and Electric automatic control valve controller Upper/Down or Rotary control. Source : AC 110V/220V or DC 24V User setting convert to easy by digital. Output Valve open/close indication. Contact, 4-20mA (Option), RS-232 (Option) Temp, Press, Humidity, Flow, Level Vibration, Iclinometer Some valve control available. Aux. Function 3-Way valve control available. P/P Reducer & Control Dimension : About 300 200 180mm E/P Converter Weight : About 2.0 kg

V-CON

Specification
Air, Water, Oil Control Fluids Temp, Press, Level, Flow, Gas, Inclino ETC Control Target Ambient Temp' 0~60 AC 110/220V 50/60Hz or DC 24V Working Voltage Air Press 4-7 kg/cm2 (Max. 10 kg/cm2) Components Controller, Sensor, Actuator Aux. Function Alarm, Valve Open/Close Percent Output Contact, 4-20mA(Option), RS-232(Option) Option/Accessory Shelter, Digital Valve Positioner (VOV_420) ETC Integration System, Actuator, Alar

Input
Temp Transmitter (4-20mA) Temp Sensor (RTD, PT-100) Pressure Transmitter (4-20mA) Diff. Press Transmitter (4-20mA) Level Transmitter (4-20mA) Level Resis Transmitter (Potentio meter) Flow Transmitter (4-20mA) Vibration Transmitter (4-20mA) Ultrasonic Transmitter (4-20mA) Gas Transmitter (4-20mA) Magnetic Transmitter (4-20mA) Opto Transmitter (4-20mA)

Control Valve

www.marsen.co.kr

42

43

www.marsen.co.kr

World reading company inside measuring and control

www.marsen.co.kr

Ullage Interface Detector (UTL-200)


General Information
Tankers shall be provided with an effective oil/water interface detectors approved by the administration. And U.T.I shall be provided for a rapid and accurate determination of the oil/water interface in slop tanks and shall be available for use in other tanks where the separation of oil and water is effected and from which it is intended to discharge effluent direct to the sea.

UTL-200
Marsen Portable Gauging System
NO MODEL SPECIFICATION Accuracy of Sensor Probe 2 mm Tape Graduation Metric Tape Resolution 1mm Tape Length 10M, 15M, 20M, 30M, 35M Measurement Temperature Range -10 to 90 Ex ia C T4 Ex Grade Tape Graduation Metric 1mm Tape Resolution 10M, 15M, 20M, 30M Tape Length Hose Size O.D 8mm I.D 6mm 15M Hose Length 2"(50A) 1"(25A)

UTL-200 (OIL-WATER INTERFACE DETECTOR)

Features
High accuracy & Responsibility Protect operator Prevent environmental pollution Easy construction Easy operation & Maintenance 2 UTL-SPL-L (LIQUID SAMPLER) UTL-SPL-G (GAS SAMPLER) DECK VALVE

3 4

Operation Principle
Detecting a change in impedance using ultra sonic technology. Measuring the different voltage according to conductivity of water. Temperature measurement is obtained by the output voltage of the built-in semiconductor element.

UTL

SAMPLER

Specification
Accuracy of ullage, interface detection Indication of level divided by ullage and interface Tape length Tape graduation Tape resolution Tape accuracy Diameter of probe Minimum detectable level Ambient temperature range Temperature sensor measurement range Temperature measurement resolution Accuracy over calibration range Temperature reading mode LCD display Top Coupling(Connection) Battery Intrinsically safe type +/- 2mm Visible and Audible 15M / 30M / 40M Metric 1mm +/-3.2mm 23mm 10mm -20 to 70 -20 to 110 0.1 +/-0.2 (0 to 70 ) (Celsius) 2 Line 16 character PF 2-1/4 TAP 9Volt (Model : MN1604) Ex ia B T4

www.marsen.co.kr

44

45

www.marsen.co.kr

World reading company inside measuring and control

www.marsen.co.kr

Portable Gas Detector & Sensor


Portable Gas Detector & Sensor

Salinity Meter (SAL-2000)


General Information
This salinity ppm alarm indicator developed for confirm to salinity density at fresh water generator or boiler feed water, etc. This device is very easy operate because made by digital programming technology. Also this device is simple a component and has a low maintenance. All components are made for endure marine environmental condition. For insurance to user's trust, all product should be publish to certificate.

Features
High accuracy Easy using method Easy installation Several accessory Digital and Analog output available Pump stop / start function available Low price Easy spread function with another system rapidly delivery time

Application
Boiler Cascadetonk Fresh Water Generator

Suction type

Consists Of System
1. Monitor LCD display key pad buzzer lamp 2. Sensor cell 3. Solenoid valve 4. Serial interface (option)

Fixed Gas Sensors

www.marsen.co.kr

Service

46

47

www.marsen.co.kr

World reading company inside measuring and control

www.marsen.co.kr

MGO-HFO Changeover System


General Information
This product is Low Sulphur Fuel Oil switching equipment that prevent marine air pollution caused by ships and meet air pollution regulations, international maritime ship costs take up most of the fuel to ensure the reduction. Currently most of the ship to sail the oceans is used the primary fuel as the HFO (Heavy Fuel Oil), but it is being regulated to used the low sulfur oil fuel MGO (Marine Gas Oil) in certain areas due to sulfur dioxide (SOx) emissions regulations, these regulations will be strengthened in addition.

Ex Solenoid Valve (Model : HAS12)


General Information
Ex Certification Kr Certification for Explosion Proof Equipment Patent application

Specification
Contents Rated Current Rated Voltage Safety Parameter Wmax Absorption Force Duty Rating Working Pressure Ex Grade SPECIFICATION 0.12A DC 12V Ui=13V Ii=2A Li=0mh Ci=0nF 4~5Watt MIN 0.5N, MAX 1.5N Continuous(100%) 160 bar, Max. 250bar(busting) -20~+50

Features
1cSt ~ 10cSt measurable Viscosity Sensor and Measurement Algorithm Fuel oil pollution prevention, and automated monitoring structures obtained Low Sulphur Oil cooling system 1 minute 2 temperature variations controlled Oil Changeover Unit to prevent thermal shock Integrated Control Panel and the sequence of H.M.I Type
IMO/EU/USA/CANADA Rule SOx Discharge Restricted Area.

Ex Power Supply (Model : HAP12)


Specification
Contents Supply Voltage Input Signal Output Voltage Storage Temperature Ex. Certification SPECIFICATION AC220V DC24V DC12V Ta +60 -20 [Ex ia] C Ui(4,6)=AC230V, Ui(1,2,3)=DC24V Po = 1W Intrinsic Uo = DC14V Associated Io = 290mA Devices parameter Lo = 0.35mH Co = 450nF

Current Signal Converter (Model : DAC420)


Specification
Contents Location of Unit Housing Material Connection Print Circuit Board Supply Voltage Input Signal Output Voltage Storage Temperature
LSFO Auto Changeover Control System Model

www.marsen.co.kr

48

49

www.marsen.co.kr

SPECIFICATION Safety Area Polycarbonate (Light Gray) Blade Pin Terminals FR-4 DC24V DC 4-20mA Contact Point Ta +60 -20

World reading company inside measuring and control

www.marsen.co.kr
Differential Pressure Transmitter (Model:DPT-420)
General Information
DPT-420 is use for the purposed of measurement for flow rate of liquid, gas, steam flow rate. It is output of the analog signal of DC 4-20ma measured Pressure corresponding. VALUE Supply Power Output Signal Accuracy Stability Temperature Ex Grade Max Static Pressure Pressure Range SPECIFICATION 10~48VDC 4-20mA, HART 0.050% 0.25% -30 ~ +85 Ex ia C T5 40 Bar 0~0.2, 0~0.4, 0~1, 0~4, 0~10 BarD

Temperature Calibrator
Features
The dry block principle excludes the use of oil or other liquids. A dry block with various diameters ensure thermal contact to sensor being tested. Simply place the sensor to be calibrated in the calibrator. Set the temperature. When stabilisation occurs, read the true temperature from the calibrator and recalibrate the sensor or system accordingly. VALUE Temperature range Resolution (display) Accuracy Stability Heating time to max Cooling time to min Thermostat test Well depth Well diameter Power supply Power consumpsion Operating temperature Dimension Weight SPECIFICATION 30 to 650 0.1 1.5 0.5 40 min 65 min Yes 155 mm 26 mm 230 VAC, 50Hz 1600 Watt 110VAC, 60Hz 0 to 40 115 280 220 Abt. 5.5 kgs

Averaging Pitot Tube (Model:APT-200)


General Information
Flow rate of fluid transport in marine is required the product of accuracy and reliability for a typical measurement requirements. Pipe to measure the flow rate in the APT-200 by inserting a pressure differential voltage and the static pressure generated by the average and the average differential pressure generated by the instrument to recognize the device so that the signal is output. VALUE Measuring fluid Material Size Temperature Working Pressure Accuracy repeatability SPECIFICATION Liquid, Gas, Steam Etc. STS316, 304 Option : STS 316L 100A ~ 800A 300 Option : -196 20 Bar 1.0% FS 0.1% FS

Pressure Calibrator
Pressure Pump
VALUE Pressure media Pressure range Process connection Reference Test device SPECIFICATION Air -1(-950mbar)... 40bar G 3/8 A female, with quick connection G 1/4 A female, with hose (1.0m) & cup nut 220 105 63 mm app. 500g seals, service & case

Electro-Hydraulic Power Pack (Model:EHPP-200)


VALUE SPECIFICATION V1 : AC220V 60Hz, V2 : DC24V Main Power Supply RS232, RS422 Communication Mode MIN. 1/100 Valve Position Resolution Delay Time Adjustment 1~10 SEC. (1 STEP 1SEC 0~10 STEP) 0~20% (1 STEP 1% 0~20STEP) Dead Band Adjustment S2, Max 30 Minutes Duty Cycle (On-Off Duty) S4 50% Ex d C T4 Type of Protection Degree of protection of IP56 enclosure -20 ~ +60 Ambient Temperature Fluid temperature -10 ~ +60

Housing Weight Including accessories

Digital Reference Test Gauge


VALUE Pressure connection Display Housing Power supply Accuracy Measuring range SPECIFICATION G1/4" male tread Multifunction LCD, 30x30mm
www.marsen.co.kr

www.marsen.co.kr

D=70, L=100, H=30mm weight app. 130g protectin class IP68 3 V-battery +/-0.5% FS +/-1 digit -1......(30)40 bar / 0.01

50

51