25 kV Neutral Section (Phase Break) From Arthur Flury AG (Switzerland)


1. 2. 3. 4. 5. Features Technical Specifications Drawings Electric Tests References

Page 1 of 9 _____________________________________________________________________________________ H.O.: A-25, Sector 50, Noida 201 301 (U.P.) - India Ph. +91 (120) 2501011-14, Fax: +91(120) 4235681, Email: ppsnoida@airtelmail.in Website: www.ppsinternational.in

PPS International
Works: 29, Functional Industrial Estate, Patparganj, Delhi 110 092 India Phone: +91(11) 43092804, Fax: +91(120) 4235681, Email: ppsnoida@airtelmail.in

Features
25 kV Arthur Flury, Switzerland Make High speed Phase Break (Neutral Section)

25 kV High Speed Phase Break for speed up to 200 km / h with 2 x 2 Teflon coated glass fiber rods. Teflon reinforced with 25% glass fiber, revolvable in case of wear, runners / skids made of copper, arcing stainless steel with contact wire clamps for 193 sq. mm contact wire, with 8 turnbuckles for adjustment of height and 8 suspension cables of bronze 10 mm2, all parts are made of non corrosive material.

Advantages of the Flury Phase Break (Neutral Section)


a) Short installation time, easy to install and to regulate b) For speed up to 200 km / h c) Larger air gap (low current-arc-self-extinguishing) d) All parts are made of non corrosive materials e) Revolvable insulator rod in case of wear, which gives a service life of more than 4 million pantograph passages. f) The arcing horn lay out guarantees a quick extinguishing of arcs g) Teflon coated glass fiber rods are more than 20 years in service, excellent long term behavior
Page 2 of 9 _____________________________________________________________________________________ H.O.: A-25, Sector 50, Noida 201 301 (U.P.) - India Ph. +91 (120) 2501011-14, Fax: +91(120) 4235681, Email: ppsnoida@airtelmail.in Website: www.ppsinternational.in

PPS International
Works: 29, Functional Industrial Estate, Patparganj, Delhi 110 092 India Phone: +91(11) 43092804, Fax: +91(120) 4235681, Email: ppsnoida@airtelmail.in

h) The guaranteed breaking load of each glass fiber rod is more than 100 kN i) The sealed end fittings and PTFE guarantee that absolutely on pollution and no ultraviolet radiation will enter to the Epoxy resin glass fiber bar j) Breaking load of Section Insulator 120 kN k) Breaking load of the insulator rod 100 kN / each l) Recommended service load 22.5 kN (1 contact wire) m) Resistant against short circuits

Page 3 of 9 _____________________________________________________________________________________ H.O.: A-25, Sector 50, Noida 201 301 (U.P.) - India Ph. +91 (120) 2501011-14, Fax: +91(120) 4235681, Email: ppsnoida@airtelmail.in Website: www.ppsinternational.in

PPS International
Works: 29, Functional Industrial Estate, Patparganj, Delhi 110 092 India Phone: +91(11) 43092804, Fax: +91(120) 4235681, Email: ppsnoida@airtelmail.in

Technical Specifications Of Neutral Section Insulator


1. Range of working conditions

1.1 Scope of application The Neutral Section insulator shall be applicable as sectioning point for two different phases of electric over head contact system of multiple phases. 50 / 60 Hz, 25 kV AC electrified rail road. It has to accept voltages up to 29 kV phase to earth as well 1.2 Type of overhead contact system: Automatically tensioned or fixed simple or compound catenaries systems. 1.3 System height: 0.8 - 2.0 m 1.4 Specification and cross- section of the contact wire The neutral section insulator shall be used for 85 193 sq. mm copper or copperalloy contact wire. The over all dimensions and the alloy of contact wire shall be stated by the customer. 1.5 Tension range of contact wire: 8 - 22.5 kN: The range of contact wire tensile load shall be stated by the customer. 1.6 Specification and cross section of messenger wire: The S.I. shall fit to different kinds of messenger wire cables. The exact size shall be given by the customer. 1.7 Tension range of catenaries: 10 25 kN. The exact value shall be given by the customer. 1.8 Running speed: 0 200 km / h 1.9 Properties of pantograph It shall work with single arm pantograph with carbon strip used at normal operation. The static pressure of collector shall be 70 120 N. 1.10 Number of pantograph passages: 2 - 4 Million for total live time of the insulator rods.
Page 4 of 9 _____________________________________________________________________________________ H.O.: A-25, Sector 50, Noida 201 301 (U.P.) - India Ph. +91 (120) 2501011-14, Fax: +91(120) 4235681, Email: ppsnoida@airtelmail.in Website: www.ppsinternational.in

PPS International
Works: 29, Functional Industrial Estate, Patparganj, Delhi 110 092 India Phone: +91(11) 43092804, Fax: +91(120) 4235681, Email: ppsnoida@airtelmail.in

1.11 Mixed Traffic The products shall be able to work under mixed tractions of electric and diesel locomotives running. In heavy polluted area of diesel locomotive traffic, the insulator rod shall be cleaned with the towel and cleaning solution every year. Trains shall not stop with the exhaust channel directly under the S.I. 1.12 Ambient temperature a) Outdoor equipments - 40 deg. C to + 50 deg C 1.13 Altitude above sea-level: 0 3000 m 1.14 Relative humidity < 90 % per month < 95 % per day

1.15 Thickness of ice-coating < 10 mm 1.16 Wind speed < 35 m / s. 1.17 The S.I. shall be resistant against earthquake shocks to 8 degrees. Others have to be stated by the customer.

Page 5 of 9 _____________________________________________________________________________________ H.O.: A-25, Sector 50, Noida 201 301 (U.P.) - India Ph. +91 (120) 2501011-14, Fax: +91(120) 4235681, Email: ppsnoida@airtelmail.in Website: www.ppsinternational.in

PPS International
Works: 29, Functional Industrial Estate, Patparganj, Delhi 110 092 India Phone: +91(11) 43092804, Fax: +91(120) 4235681, Email: ppsnoida@airtelmail.in

2.
2.1

Specifications and requirements


The neutral section insulator shall consist of the insulator bodies to insert into the contact wire, including all metal parts, relevant connecting parts, hanger cables and the insulator with fittings for the messenger wire cable. By the neutral section shall be direct sliding contact between the insulating body of the section insulator and the pantograph. Usually, the pantograph passes onto the neutral section insulator without current consumption. If the pantograph passes with consuming current, the neutral section insulator has the specified arcextinguishing capacity so as to protect the insulating part of the neutral section insulator from arcing damage. The locomotive may pass the N.S.I. with current consumption up to 100 amps without creating a short circuit. The neutral section insulator is provided with an earthed middle section to avoid any phase to phase short circuit faults. The earth resistance is required to be less than 10 ohm. Material of neutral section insulator The neutral section insulator shall be made with glass fiber rod covered by virgin PTFE to guarantee excellent electrical and mechanical properties. The PTFE cover shall offer a self cleaning ability under rain water and low wear rate. The rods shall be revolvable 5 times in case of wear to guarantee a live time of 2-4 million passes of pantographs. The relevant metal fitting and all kind of accessories and fastening parts shall be made of anticorrosive materials, such as copper alloys (CuNiSi) of stainless steel.

2.2

2.3

2.4

Material of runners The runner shall be made of copper guarantee an optimal conductivity and arcing properties while passing pantographs. Material of arcing horns The arcing horn shall be made of stainless steel. They shall be specially designed to keep the arc away from insulating material and to guide the arc quickly upward for extinguishing without damage of material.

2.5

3.

Service life:
It shall not be less than 20 years. The aging and wear resistance at direct sliding of the insulator shall be taken into account.

Page 6 of 9 _____________________________________________________________________________________ H.O.: A-25, Sector 50, Noida 201 301 (U.P.) - India Ph. +91 (120) 2501011-14, Fax: +91(120) 4235681, Email: ppsnoida@airtelmail.in Website: www.ppsinternational.in

PPS International
Works: 29, Functional Industrial Estate, Patparganj, Delhi 110 092 India Phone: +91(11) 43092804, Fax: +91(120) 4235681, Email: ppsnoida@airtelmail.in

4.
4.1

Performance and technical requirements


In the period of service life, the requirements for electrical and physical performances of the insulator are listed in below table. The relevant test methods and standards are IEC 507:71-1; 71-2: 1109

Table 1 Electrical requirements 1 2 3 4 Power frequency withstand voltage dry Power frequency withstand voltage wet Lightning impulse withstand voltage dry Power frequency pollution withstands voltage acc. To IEC 507 (224kg/m3) Leakage distance Insulation resistance Leakage current Arc withstand property Water absorption Thermal conductivity 4.2 Table-2 Mechanical requirements Insulator rod Destructive tensile load >100 kN Starting sliding load between fittings and contact wire Bending strength Max twist Max deflection Vibration performance Wear ability Neutral Section Insulator >120 kN No sliding until fully breaking load of contact wire 350 Nm 90 deg on 1500 mm 6 mm Resistant against Resistant against vibrations vibrations >2 million passages Runners>0.5 mi. in lab. passages Insulator rod >600 kv >395 kv >950 kv 60 kv Neutral insulator >500kv >300kv >800kv 60kv section

5 6 7 8 9 10

2500 mm >1.2 GOhm <120 micro A 0 0.23 w/mK

2500 mm >1.2 GOhm <120 micro A 5.4kAfor 0.125 sec 0

The requirements of mechanical properties of components and the complete assembled section insulator are shown in table below.

1 2

3 4 5 6 7

Page 7 of 9 _____________________________________________________________________________________ H.O.: A-25, Sector 50, Noida 201 301 (U.P.) - India Ph. +91 (120) 2501011-14, Fax: +91(120) 4235681, Email: ppsnoida@airtelmail.in Website: www.ppsinternational.in

PPS International
Works: 29, Functional Industrial Estate, Patparganj, Delhi 110 092 India Phone: +91(11) 43092804, Fax: +91(120) 4235681, Email: ppsnoida@airtelmail.in

5.
5.1

Tests
The typical type tests for P.T.F.E. glass fiber insulators shall be made according to the relevant test standards IEC 507:71-1; 71-2; 383; 1109 Sampling tests: Before each delivery, 1% of the units have to be checked by the quality control. The following has to be checked:

5.2

a) b) c)

Measuring inspection against quality recommendations ISO 9000. Material control against DIN recommendations. Tensile load test up to 30 kN. After this inspection, the customer shall receive the test certificate and the units shall be properly packed ready for dispatch.

6.

Technical Service and Training

The manufacturer shall offer the instruction manuals for assembly and drawings in the quotation. The manufacturer shall send on customer request an engineer to work on site for training of the customers staff on chargeable basis. The manufacturer shall state the name, specifications and quantity of the relevant spare parts, materials and special tools and instruments to be supplied with the section insulators during delivery.

7.

Technical Documents

Drawings The manufacturer shall furnish the assembly drawings (including main dimensions and total weight) and drawings of all components and fastenings etc. of the section insulator and shall make a description of the name, quantity, size, material and unit weight of all components, and anti-corrosive measures of steel components.

Page 8 of 9 _____________________________________________________________________________________ H.O.: A-25, Sector 50, Noida 201 301 (U.P.) - India Ph. +91 (120) 2501011-14, Fax: +91(120) 4235681, Email: ppsnoida@airtelmail.in Website: www.ppsinternational.in

PPS International
Works: 29, Functional Industrial Estate, Patparganj, Delhi 110 092 India Phone: +91(11) 43092804, Fax: +91(120) 4235681, Email: ppsnoida@airtelmail.in

Installation, maintenance and other technical documents Each box with 1 Neutral Section Insulator shall contain installation instruction as well as one assembly drawing. Mark and packing The marking and packing shall be against the customers instructions. Packing in proper seaworthy cardboard boxes. 1 neutral section insulator shall be packed in one box.

8.

Guarantee period
The guarantee period shall be given with the quotation.

ARTHUR FLURY AG, SWITZERLAND

Adrian Flury Managing Director

Rolf Staubli Chief Engineer

The above document is the abstract of Arthur Flury AG, Switzerlands document, hence PPS International is not responsible for any error.

Page 9 of 9 _____________________________________________________________________________________ H.O.: A-25, Sector 50, Noida 201 301 (U.P.) - India Ph. +91 (120) 2501011-14, Fax: +91(120) 4235681, Email: ppsnoida@airtelmail.in Website: www.ppsinternational.in